메뉴 건너뛰기




Volumn 75, Issue 2, 2011, Pages 294-304

Monitoring crack development in fiber concrete beam by using electrical resistivity imaging

Author keywords

Cracks in concrete; Electric imaging; Fiber concrete; Resistivity correction; Resistivity inversion

Indexed keywords

ARTIFICIAL CRACKS; BEAM SIZE; CONCRETE COMPRESSIVE STRENGTH; CONCRETE RESISTIVITY; CONCRETE SPECIMENS; CRACK DEVELOPMENT; CURING TIME; DAMAGED CONCRETES; DEVELOPMENT TRENDS; ELECTRIC IMAGING; ELECTRICAL IMAGING; ELECTRICAL RESISTIVITY IMAGING; FIBER CONCRETE; IMAGING SURVEYS; IN-FIBER; LOADING TESTS; RESISTIVITY MEASUREMENT;

EID: 80052320924     PISSN: 09269851     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jappgeo.2011.06.009     Document Type: Article
Times cited : (38)

References (15)
  • 3
    • 0017525952 scopus 로고
    • A modified pseudosection for resistivity and induced-polarization
    • Edwards L.S. A modified pseudosection for resistivity and induced-polarization. Geophysics 1977, 42:1020-1036.
    • (1977) Geophysics , vol.42 , pp. 1020-1036
    • Edwards, L.S.1
  • 4
    • 0037338382 scopus 로고    scopus 로고
    • Electric imaging and laboratory resistivity testing for geotechnical investigation of Pusan clay deposits
    • Giao P.H., Chung S.G., Kim D.Y., Tanaka H. Electric imaging and laboratory resistivity testing for geotechnical investigation of Pusan clay deposits. Journal of Applied Geophysics 2003, 52:157-175.
    • (2003) Journal of Applied Geophysics , vol.52 , pp. 157-175
    • Giao, P.H.1    Chung, S.G.2    Kim, D.Y.3    Tanaka, H.4
  • 5
    • 0033200788 scopus 로고    scopus 로고
    • Measurement of concrete resistivity for assessment of corrosion severity of steel using Wenner technique
    • Growers K.R., Millard S.G. Measurement of concrete resistivity for assessment of corrosion severity of steel using Wenner technique. ACI Materials Journal 1999, 95(5):536-541.
    • (1999) ACI Materials Journal , vol.95 , Issue.5 , pp. 536-541
    • Growers, K.R.1    Millard, S.G.2
  • 6
    • 0030197227 scopus 로고    scopus 로고
    • The resistivity of pore water solution - a decisive parameter of rebar corrosion and repair methods
    • Hunkeler F. The resistivity of pore water solution - a decisive parameter of rebar corrosion and repair methods. Construction and Building Materials 1996, 10:381-389.
    • (1996) Construction and Building Materials , vol.10 , pp. 381-389
    • Hunkeler, F.1
  • 10
    • 0029668032 scopus 로고    scopus 로고
    • Rapid least-squares inversion of apparent resistivity pseudosections using a quasi-Newton method
    • Loke M.H., Barker R.D. Rapid least-squares inversion of apparent resistivity pseudosections using a quasi-Newton method. Geophysical Prospecting 1996, 44:131-152.
    • (1996) Geophysical Prospecting , vol.44 , pp. 131-152
    • Loke, M.H.1    Barker, R.D.2
  • 11
    • 0030399411 scopus 로고    scopus 로고
    • Practical evaluation of resistivity of concrete in test cylinders using a Wenner array probe
    • Morris W., Moreno E.I., Sagues A.A. Practical evaluation of resistivity of concrete in test cylinders using a Wenner array probe. Cement and Concrete Research 1996, 26:1779-1787.
    • (1996) Cement and Concrete Research , vol.26 , pp. 1779-1787
    • Morris, W.1    Moreno, E.I.2    Sagues, A.A.3
  • 14
    • 0035283448 scopus 로고    scopus 로고
    • Test methods for on-site measurement of resistivity of concrete - a RILEM TC-154 technical recommendation
    • Polder R.B. Test methods for on-site measurement of resistivity of concrete - a RILEM TC-154 technical recommendation. Construction and Building Materials 2001, 15:125-131.
    • (2001) Construction and Building Materials , vol.15 , pp. 125-131
    • Polder, R.B.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.