메뉴 건너뛰기




Volumn 68, Issue 3, 2011, Pages 120-125

Serum globulins contribute to the discrepancies observed between the bromocresol green and bromocresol purple assays of serum albumin concentration

Author keywords

Bromcresol green; Bromcresol purple; Serum albumin; Serum globulins

Indexed keywords

ALBUMIN; ALPHA 1 GLOBULIN; ALPHA 2 GLOBULIN; BETA GLOBULIN; BROMCRESOL PURPLE; BROMOCRESOL GREEN; GLOBULIN; IMMUNOGLOBULIN; UNCLASSIFIED DRUG;

EID: 80052215734     PISSN: 09674845     EISSN: None     Source Type: Journal    
DOI: 10.1080/09674845.2011.11730338     Document Type: Article
Times cited : (15)

References (24)
  • 2
    • 0031728983 scopus 로고    scopus 로고
    • Influence of methodology on the detection and diagnosis of congenital analbuminemia
    • Lyon AW, Meinert P, Bruce GA, Laxdal VA, Salkie ML. Influence of methodology on the detection and diagnosis of congenital analbuminemia. Clin Chem 1998; 44: 2365-7. (Pubitemid 28511763)
    • (1998) Clinical Chemistry , vol.44 , Issue.11 , pp. 2365-2367
    • Lyon, A.W.1    Meinert, P.2    Bruce, G.A.3    Laxdal, V.A.4    Salkie, M.L.5
  • 5
    • 0036264602 scopus 로고    scopus 로고
    • Sample matrix is critical in the evaluation of a dry-slide bromocresol green method for human albumin
    • DOI 10.1258/0004563021902026
    • Payn MM, Lawrence D, Willis R, Lamb EJ. Sample matrix is critical in the evaluation of a dry-slide bromocresol green method for human albumin. Ann Clin Biochem 2002; 39: 311-3. (Pubitemid 34494222)
    • (2002) Annals of Clinical Biochemistry , vol.39 , Issue.3 , pp. 311-313
    • Payn, M.M.1    Lawrence, D.2    Willis, R.3    Lamb, E.J.4
  • 6
    • 80052233848 scopus 로고    scopus 로고
    • Design of method comparison study and bias estimation for albumin assays
    • Guo J, Xie J, Zhao H. Design of method comparison study and bias estimation for albumin assays. Chinese J Lab Med 2000; 23: 22-4.
    • (2000) Chinese J Lab Med , vol.23 , pp. 22-24
    • Guo, J.1    Xie, J.2    Zhao, H.3
  • 7
    • 0023232834 scopus 로고
    • Underestimation of serum albumin by the bromcresol purple method and a major endogenous ligand in uremia
    • DOI 10.1016/0009-8981(87)90089-1
    • Mabuchi H, Nakahashi H. Underestimation of serum albumin by the bromocresol purple method and a major endogenous ligand in uremia. Clin Chim Acta 1987; 167: 89-96. (Pubitemid 17147612)
    • (1987) Clinica Chimica Acta , vol.167 , Issue.1 , pp. 89-96
    • Mabuchi, H.1    Nakahashi, H.2
  • 8
    • 0034851114 scopus 로고    scopus 로고
    • Conversion between bromcresol green- and bromcresol purple-measured albumin in renal disease
    • Clase CM, St Pierre MW, Churchill DN. Conversion between bromocresol green- and bromocresol purple-measured albumin in renal disease. Nephrol Dial Transplant 2001; 16: 1925-9. (Pubitemid 32821429)
    • (2001) Nephrology Dialysis Transplantation , vol.16 , Issue.9 , pp. 1925-1929
    • Clase, C.M.1    St., P.M.W.2    Churchill, D.N.3
  • 9
    • 0023359666 scopus 로고
    • Bromocresol purple dye-binding methods underestimate albumin that is carrying covalently bound bilirubin
    • Bush V, Reed RG. Bromocresol purple dye-binding methods underestimate albumin that is carrying covalently bound bilirubin. Clin Chem 1987; 33: 821-3.
    • (1987) Clin Chem , vol.33 , pp. 821-823
    • Bush, V.1    Reed, R.G.2
  • 10
    • 0028211133 scopus 로고
    • Bromcresol purple dye-binding and immunoturbidimetry for albumin measurement in plasma or serum of patients with renal failure [2]
    • Beyer C, Boekhout M, van Iperen H. Bromocresol purple dye-binding and immunoturbidimetry for albumin measurement in plasma or serum of patients with renal failure. Clin Chem 1994; 40: 844-5. (Pubitemid 24142868)
    • (1994) Clinical Chemistry , vol.40 , Issue.5 , pp. 844-845
    • Beyer, C.1    Boekhout, M.2    Van Iperen, H.3
  • 11
    • 1642276935 scopus 로고    scopus 로고
    • Problems in serum albumin measurement and clinical significance of albumin microheterogeneity in cirrhotics
    • DOI 10.1016/j.nut.2003.12.006, PII S0899900703003046
    • Watanabe A, Matsuzaki S, Moriwaki H, Suzuki K, Nishiguchi S. Problems in serum albumin measurement and clinical significance of albumin microheterogeneity in cirrhotics. Nutrition 2004; 20: 351-7. (Pubitemid 38388508)
    • (2004) Nutrition , vol.20 , Issue.4 , pp. 351-357
    • Watanabe, A.1    Matsuzaki, S.2    Moriwaki, H.3    Suzuki, K.4    Nishiguchi, S.5
  • 12
    • 0017160415 scopus 로고
    • Improved specificity of serum albumin determination and estimation of 'acute phase reactants' by use of the bromocresol green reaction
    • Gustafsson JE. Improved specificity of serum albumin determination and estimation of 'acute phase reactants' by use of the bromocresol green reaction. Clin Chem 1976; 22: 616-22.
    • (1976) Clin Chem , vol.22 , pp. 616-622
    • Gustafsson, J.E.1
  • 13
    • 0016203356 scopus 로고
    • A study of the interaction of bromocresol green with isolated serum globulin fractions
    • Webster D. A study of the interaction of bromocresol green with isolated serum globulin fractions. Clin Chim Acta 1974; 53: 109-15.
    • (1974) Clin Chim Acta , vol.53 , pp. 109-115
    • Webster, D.1
  • 15
    • 43049172035 scopus 로고    scopus 로고
    • Protein precipitation using ammonium sulfate
    • May; Appendix 3: Appendix 3F
    • Wingfield P. Protein precipitation using ammonium sulfate. Curr Protoc Protein Sci 2001 May; Appendix 3: Appendix 3F.
    • (2001) Curr Protoc Protein Sci
    • Wingfield, P.1
  • 16
    • 0035217602 scopus 로고    scopus 로고
    • Guidance for selecting the measurement conditions in the dye-binding method for determining serum protein: Theoretical analysis based on the chemical equilibrium of protein error
    • DOI 10.2116/analsci.17.1263
    • Suzuki Y. Guidance for selecting the measurement conditions in the dye-binding method for determining serum protein: theoretical analysis based on the chemical equilibrium of protein error. Anal Sci 2001; 17: 1263-8. (Pubitemid 33150734)
    • (2001) Analytical Sciences , vol.17 , Issue.11 , pp. 1263-1268
    • Suzuki, Y.1
  • 17
    • 0017797010 scopus 로고
    • New automated dye binding method for serum albumin determination with bromcresol purple
    • Pinnell AE, Northam BE. New automated dye-binding method for serum albumin determination with bromocresol purple. Clin Chem 1978; 24: 80-6. (Pubitemid 8262864)
    • (1978) Clinical Chemistry , vol.24 , Issue.1 , pp. 80-86
    • Pinnell, A.E.1    Northam, B.E.2
  • 18
    • 0141841749 scopus 로고    scopus 로고
    • Discrepancies in serum albumin measurements vary by dialysis modality
    • DOI 10.1081/JDI-120024294
    • Parikh C, Yalavarthy R, Gurevich A, Robinson A, Teitelbaum I. Discrepancies in serum albumin measurements vary by dialysis modality. Ren Fail 2003; 25: 787-96. (Pubitemid 37187673)
    • (2003) Renal Failure , vol.25 , Issue.5 , pp. 787-796
    • Parikh, C.1    Yalavarthy, R.2    Gurevich, A.3    Robinson, A.4    Teitelbaum, I.5
  • 19
    • 39849099555 scopus 로고    scopus 로고
    • Lithium heparinised blood-collection tubes give falsely low albumin results with an automated bromcresol green method in haemodialysis patients
    • DOI 10.1515/CCLM.2008.079
    • Meng QH, Krahn J. Lithium heparinised blood-collection tubes give falsely low albumin results with an automated bromocresol green method in haemodialysis patients. Clin Chem Lab Med 2008; 46: 396-400. (Pubitemid 351317778)
    • (2008) Clinical Chemistry and Laboratory Medicine , vol.46 , Issue.3 , pp. 396-400
    • Meng, Q.H.1    Krahn, J.2
  • 20
    • 0021853937 scopus 로고
    • Albumin analysis in serum of haemodialysis patients: Discrepancies between bromocresol purple, bromocresol green and electroimmunoassay
    • Wells FE, Addison GM, Postlethwaite RJ. Albumin analysis in serum of haemodialysis patients: discrepancies between bromocresol purple, bromocresol green and electroimmunoassay. Ann Clin Biochem 1985; 22 (Pt 3): 304-9. (Pubitemid 15002256)
    • (1985) Annals of Clinical Biochemistry , vol.22 , Issue.3 , pp. 304-309
    • Wells, F.E.1    Addison, G.M.2    Postlethwaite, R.J.3
  • 21
    • 34249867199 scopus 로고    scopus 로고
    • Comparison of bromcresol green and agarose protein electrophoresis for quantitation of serum albumin in multiple myeloma
    • DOI 10.1373/clinchem.2007.088252
    • Snozek CL, Saenger AK, Greipp PR et al. Comparison of bromocresol green and agarose protein electrophoresis for quantitation of serum albumin in multiple myeloma. Clin Chem 2007; 53: 1099-103. (Pubitemid 46867526)
    • (2007) Clinical Chemistry , vol.53 , Issue.6 , pp. 1099-1103
    • Snozek, C.L.H.1    Saenger, A.K.2    Greipp, P.R.3    Bryant, S.C.4    Kyle, R.A.5    Rajkumar, S.V.6    Katzmann, J.A.7
  • 22
    • 70449720917 scopus 로고    scopus 로고
    • Comparison of urinary albumin quantification by immunoturbidimetry, competitive immunoassay and protein-cleavage liquid chromatography-tandem mass spectrometry
    • Seegmiller JC, Sviridov D, Larson TS, Borland TM, Hortin GL, Lieske JC. Comparison of urinary albumin quantification by immunoturbidimetry, competitive immunoassay and protein-cleavage liquid chromatography-tandem mass spectrometry. Clin Chem 2009; 55: 1991-4.
    • (2009) Clin Chem , vol.55 , pp. 1991-1994
    • Seegmiller, J.C.1    Sviridov, D.2    Larson, T.S.3    Borland, T.M.4    Hortin, G.L.5    Lieske, J.C.6
  • 23
    • 44949089738 scopus 로고    scopus 로고
    • Determining the identity and purity of recombinant proteins by UV absorption spectroscopy
    • Chapter 7: Unit 7.2
    • Mach H, Middaugh CR, Denslow N. Determining the identity and purity of recombinant proteins by UV absorption spectroscopy. Curr Protoc Protein Sci 2001; Chapter 7: Unit 7.2.
    • (2001) Curr Protoc Protein Sci
    • Mach, H.1    Middaugh, C.R.2    Denslow, N.3
  • 24
    • 0141884385 scopus 로고    scopus 로고
    • Measurement of serum albumin by capillary zone electrophoresis, bromocresol green, bromocresol purple, and immunoassay methods
    • DOI 10.1136/jcp.56.10.780
    • Duly EB, Grimason S, Grimason P, Barnes G , Trinick TR. Measurement of serum albumin by capillary zone electrophoresis, bromocresol green, bromocresol purple and immunoassay methods. J Clin Pathol 2003; 56: 780-1. (Pubitemid 37243941)
    • (2003) Journal of Clinical Pathology , vol.56 , Issue.10 , pp. 780-781
    • Duly, E.B.1    Grimason, S.2    Grimason, P.3    Barnes, G.4    Trinick, T.R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.