메뉴 건너뛰기




Volumn 56, Issue 18, 2011, Pages 5877-5888

Characterization of a high-purity germanium detector for small-animal SPECT

Author keywords

[No Author keywords available]

Indexed keywords

DEPTH OF INTERACTIONS; ENERGY RESOLUTIONS; GAMMA CAMERAS; HIGH-PURITY GERMANIUM; HIGH-PURITY GERMANIUM DETECTOR; INTRINSIC EFFICIENCY; POINT SOURCES; SMALL-ANIMAL; SPATIAL RESOLUTION; STRIP DETECTORS;

EID: 80052072992     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/56/18/007     Document Type: Article
Times cited : (23)

References (29)
  • 1
    • 0034273330 scopus 로고    scopus 로고
    • Three-dimensional position sensing and field shaping in orthogonal-strip germanium gamma-ray detectors
    • Amman M and Luke P N 2000 Three-dimensional position sensing and field shaping in orthogonal-strip germanium gamma-ray detectors Nucl. Instrum. Methods Phys. Res. A 452 155-66
    • (2000) Nucl. Instrum. Methods Phys. Res. , vol.452 , Issue.1-2 , pp. 155-166
    • Amman, M.1    Luke, P.N.2
  • 3
    • 67649211044 scopus 로고    scopus 로고
    • Overview of the nuclear Compton telescope
    • Bellm E C et al 2009 Overview of the nuclear Compton telescope IEEE Trans. Nucl. Sci. 56 1250-6
    • (2009) IEEE Trans. Nucl. Sci. , vol.56 , Issue.3 , pp. 1250-1256
    • Bellm, E.C.1
  • 5
    • 23844463889 scopus 로고    scopus 로고
    • Signal interpolation in germanium detectors for improved 3-D position resolution
    • N24-2, 2004 IEEE Nuclear Science Symposium Conference Record
    • Burks M, Jordan E, Hull E, Mihailescu L and Vetter K 2004 Signal interpolation in germanium detectors for improved 3D position resolution IEEE Nuclear Science Symp. Conf. Record, 2004 vol 2 pp 1114-8 (Pubitemid 41155709)
    • (2004) IEEE Nuclear Science Symposium Conference Record , vol.2 , pp. 1114-1118
    • Burks, M.1    Jordan, E.2    Hull, E.3    Mihailescu, L.4    Vetter, K.5
  • 6
    • 67349173963 scopus 로고    scopus 로고
    • Toward quantitative small animal pinhole SPECT: Assessment of quantitation accuracy prior to image compensations
    • Chen C L, Wang Y, Lee J J and Tsui B M 2009 Toward quantitative small animal pinhole SPECT: assessment of quantitation accuracy prior to image compensations Mol. Imaging Biol. 11 195-203
    • (2009) Mol. Imaging Biol. , vol.11 , Issue.3 , pp. 195-203
    • Chen, C.L.1    Wang, Y.2    Lee, J.J.3    Tsui, B.M.4
  • 9
    • 63149148800 scopus 로고    scopus 로고
    • Performance tests of large area position-sensitive planar germanium detectors with conventional and amorphous contacts
    • Gros S, Hammond N J, Lister C J, Chowdhury P, Fischer S M and Freeman S J 2009 Performance tests of large area position-sensitive planar germanium detectors with conventional and amorphous contacts Nucl. Instrum. Methods Phys. Res. A 602 467-76
    • (2009) Nucl. Instrum. Methods Phys. Res. , vol.602 , Issue.2 , pp. 467-476
    • Gros, S.1    Hammond, N.J.2    Lister, C.J.3    Chowdhury, P.4    Fischer, S.M.5    Freeman, S.J.6
  • 10
    • 0016922949 scopus 로고
    • Amorphous germanium as an electron or hole blocking contact on high-purity germanium detectors
    • Hansen W L and Haller E E 1977 Amorphous germanium as an electron or hole blocking contact on high-purity germanium detectors IEEE Trans. Nucl. Sci. 24 61-3
    • (1977) IEEE Trans. Nucl. Sci. , vol.24 , Issue.1 , pp. 61-63
    • Hansen, W.L.1    Haller, E.E.2
  • 12
    • 39049168972 scopus 로고    scopus 로고
    • Incomplete charge collection in an HPGe double-sided strip detector
    • Hayward J and Wehe D 2008a Incomplete charge collection in an HPGe double-sided strip detector Nucl. Instrum. Methods Phys. Res. A 586 215-23
    • (2008) Nucl. Instrum. Methods Phys. Res. , vol.586 , pp. 215-223
    • Hayward, J.1    Wehe, D.2
  • 13
    • 85008045221 scopus 로고    scopus 로고
    • Charge loss correction in a high-purity germanium double-sided strip detector
    • Hayward J P and Wehe D K 2008b Charge loss correction in a high-purity germanium double-sided strip detector IEEE Trans. Nucl. Sci. 55 2789-97
    • (2008) IEEE Trans. Nucl. Sci. , vol.55 , Issue.5 , pp. 2789-2797
    • Hayward, J.P.1    Wehe, D.K.2
  • 14
    • 67649236383 scopus 로고    scopus 로고
    • Inter-strip interpolation measurements in a high-purity germanium double-sided strip detector
    • Hayward J P and Wehe D K 2009 Inter-strip interpolation measurements in a high-purity germanium double-sided strip detector IEEE Trans. Nucl. Sci. 56 800-7
    • (2009) IEEE Trans. Nucl. Sci. , vol.56 , Issue.3 , pp. 800-807
    • Hayward, J.P.1    Wehe, D.K.2
  • 15
    • 79960358852 scopus 로고    scopus 로고
    • Review and current status of SPECT scatter correction
    • Hutton B F, Buvat I and Beekman F J 2011 Review and current status of SPECT scatter correction Phys. Med. Biol. 56 R85
    • (2011) Phys. Med. Biol. , vol.56 , Issue.14 , pp. 85
    • Hutton, B.F.1    Buvat, I.2    Beekman, F.J.3
  • 16
    • 42449085442 scopus 로고    scopus 로고
    • Assessment of the sources of error affecting the quantitative accuracy of SPECT imaging in small animals
    • DOI 10.1088/0031-9155/53/9/002, PII S0031915508618163
    • Hwang A B, Franc B L, Gullberg G T and Hasegawa B H 2008 Assessment of the sources of error affecting the quantitative accuracy of SPECT imaging in small animals Phys. Med. Biol. 53 2233-52 (Pubitemid 351570908)
    • (2008) Physics in Medicine and Biology , vol.53 , Issue.9 , pp. 2233-2252
    • Hwang, A.B.1    Franc, B.L.2    Gullberg, G.T.3    Hasegawa, B.H.4
  • 23
    • 70350200886 scopus 로고    scopus 로고
    • Development of an ultra-high resolution SPECT system with a CdTe semiconductor detector
    • Ogawa K, Ohmura N, Iida H, Nakamura K, Nakahara T and Kubo A 2009 Development of an ultra-high resolution SPECT system with a CdTe semiconductor detector Ann. Nucl. Med. 23 763-70
    • (2009) Ann. Nucl. Med. , vol.23 , Issue.8 , pp. 763-770
    • Ogawa, K.1    Ohmura, N.2    Iida, H.3    Nakamura, K.4    Nakahara, T.5    Kubo, A.6
  • 25
    • 0018942754 scopus 로고
    • An ultrapure germanium detector array for quantitating three-dimensional distribution of a radionuclide: A study of phantoms
    • Rusinek H, Reich T, Youdin M, Clagnaz M and Kolwicz R 1980 An ultrapure germanium detector array for quantitating three-dimensional distribution of a radionuclide: a study of phantoms J. Nucl. Med. 21 777-82 (Pubitemid 10037046)
    • (1980) Journal of Nuclear Medicine , vol.21 , Issue.8 , pp. 777-782
    • Rusinek, H.1    Reich, T.2    Youdin, M.3
  • 26
    • 67349083609 scopus 로고    scopus 로고
    • Improved quantification in single-pinhole and multiple-pinhole SPECT using micro-CT information
    • Vanhove C, Defrise M, Bossuyt A and Lahoutte T 2009 Improved quantification in single-pinhole and multiple-pinhole SPECT using micro-CT information Eur. J. Nucl. Med. Mol. Imaging 36 1049-63
    • (2009) Eur. J. Nucl. Med. Mol. Imaging , vol.36 , Issue.7 , pp. 1049-1063
    • Vanhove, C.1    Defrise, M.2    Bossuyt, A.3    Lahoutte, T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.