메뉴 건너뛰기




Volumn 11, Issue 10, 2011, Pages 2576-2582

A new potentiometric sensor for the determination of desipramine based on N-(1-naphthyl)ethylenediamine dihydrochloride-tetraphenyl borate

Author keywords

Desipramine sensor; ion selective electrode; protein interaction

Indexed keywords

ALKALINE EARTH; BOVINE SERUM ALBUMINS; BUFFER SOLUTIONS; CONCENTRATION RANGES; DESIPRAMINE SENSOR; DRUG BINDING; ETHYLENE DIAMINE; HILL EQUATION; INDICATOR ELECTRODES; ION PAIRS; NERNSTIAN RESPONSE; PLASMA SAMPLES; POLY (VINYL CHLORIDE) MEMBRANE; PROTEIN INTERACTION; SODIUM TETRAPHENYLBORATE; WIDE PH RANGE;

EID: 80052072526     PISSN: 1530437X     EISSN: None     Source Type: Journal    
DOI: 10.1109/JSEN.2011.2146247     Document Type: Article
Times cited : (9)

References (124)
  • 2
    • 12344301274 scopus 로고    scopus 로고
    • 2,2′-Bipyridine as a new and sensitive spectrophotometric reagent for the determination of nanoamounts of certain dibenzazepine class of tricyclic antidepressant drugs
    • DOI 10.1016/j.farmac.2004.04.011, PII S0014827X04002113
    • A. Syeda, H. R. K. Mahesh, and A. A. Syed, "2, 2'-Bipyridine as a new and sensitive spectrophotometric reagent for the determination of nanoamounts of certain dibenzazepine class of tricyclic antidepressant drugs", Farmaco, vol. 60, pp. 47-51, 2005. (Pubitemid 40126289)
    • (2005) Farmaco , vol.60 , Issue.1 , pp. 47-51
    • Syeda, A.1    Mahesh, H.R.K.2    Syed, A.A.3
  • 3
    • 0036073826 scopus 로고    scopus 로고
    • Spectrophotometric determination of some antidepressant drugs
    • DOI 10.1081/AL-120005970
    • W. Misiuk and H. Puzanowska-Tarasiewicz, "Spectrophotometric determination of some antidepressant drugs", Anal. Lett., vol. 35, pp. 1163-1170, 2002. (Pubitemid 34804039)
    • (2002) Analytical Letters , vol.35 , Issue.7 , pp. 1163-1170
    • Misiuk, W.1    Puzanowska-Tarasiewicz, H.2
  • 4
    • 0034682296 scopus 로고    scopus 로고
    • Highly selective and sensitive determination of tricyclic antidepressants in human plasma using high-performance liquid chromatography with post-column tris(2,2'-bipyridyl) ruthenium(III) chemiluminescence detection
    • DOI 10.1016/S0003-2670(00)00788-1, PII S0003267000007881
    • H. Yoshida, K. Hidaka, J. Ishida, K. Yoshikuni, H. Nohta, and M. Yamaguchi, "Highly selective and sensitive determination of tricyclic antidepressants in human plasma using high-performance liquid chromatography with post-column tris (2, 2'-bipyridyl) ruthenium (III) chemiluminescence detection", Anal. Chim. Acta, vol. 413, pp. 137-145, 2000. (Pubitemid 30224724)
    • (2000) Analytica Chimica Acta , vol.413 , Issue.1-2 , pp. 137-145
    • Yoshida, H.1    Hidaka, K.2    Ishida, J.3    Yoshikuni, K.4    Nohta, H.5    Yamaguchi, M.6
  • 5
    • 0030955635 scopus 로고    scopus 로고
    • Simultaneous determination of imipramine, desipramine and their 2- and 10-hydroxylated metabolites in human plasma and urine
    • DOI 10.1016/S0378-4347(97)00053-4, PII S0378434797000534
    • A. G. Chen, Y. K. Wing, H. Chiu, S. Lee, C. N. Chen, and K. Chan, "Simultaneous determination of imipramine, desipramine and their 2-and 10-hydroxylated metabolites in human plasma and urine by highperformance liquid chromatography", J. Chromatogr. B: Biomed. Sci. Appl., vol. 693, pp. 153-158, 1997. (Pubitemid 27229627)
    • (1997) Journal of Chromatography B: Biomedical Applications , vol.693 , Issue.1 , pp. 153-158
    • Chen, A.G.1    Wing, Y.K.2    Chiu, H.3    Lee, S.4    Chen, C.N.5    Chan, K.6
  • 6
    • 4944243744 scopus 로고    scopus 로고
    • Method for simultaneous determination of eight cyclic antidepressants by cyclodextrin-modified capillary zone electrophoresis: Applications in pharmaceuticals
    • H. S. Kou, C. C. Chen, Y. H. Huang, W. K. Ko, and H. L. Wu, "Method for simultaneous determination of eight cyclic antidepressants by cyclodextrin-modified capillary zone electrophoresis: Applications in pharmaceuticals", Anal. Chim. Acta, vol. 525, pp. 23-30, 2004.
    • (2004) Anal. Chim. Acta , vol.525 , pp. 23-30
    • Kou, H.S.1    Chen, C.C.2    Huang, Y.H.3    Ko, W.K.4    Wu, H.L.5
  • 7
    • 0022719038 scopus 로고
    • Voltammetric measurement of tricyclic antidepressants following interfacial accumulation at carbon electrodes
    • J. Wang, M. Bonakdar, and C. Morgan, "Voltammetric measurement of tricyclic antidepressants following interfacial accumulation at carbon electrodes", Anal. Chem., vol. 58, pp. 1024-1028, 1986. (Pubitemid 16119332)
    • (1986) Analytical Chemistry , vol.58 , Issue.6 , pp. 1024-1028
    • Wang, J.1    Bonakdar, M.2    Morgan, C.3
  • 8
    • 84963253719 scopus 로고
    • Electrochemical determination of tricyclic antidepressants
    • E. S. Smotkin, G. B. Martin, and G. A. Rechnitz, "Electrochemical determination of tricyclic antidepressants", Anal. Lett., vol. 24, pp. 798-808, 1991.
    • (1991) Anal. Lett. , vol.24 , pp. 798-808
    • Smotkin, E.S.1    Martin, G.B.2    Rechnitz, G.A.3
  • 9
    • 77956145532 scopus 로고    scopus 로고
    • Combined hollow fiber-based liquid-liquid-liquid microextraction and in-situ differential pulse voltammetry to improve selectivity, sensitivity, and interference elimination in electrochemical analysis
    • M. Saraji, B. Farajmand, A. A. Ensafi, A. R. Allafchian, and Z. Mirahmdi-Zare, "Combined hollow fiber-based liquid-liquid-liquid microextraction and in-situ differential pulse voltammetry to improve selectivity, sensitivity, and interference elimination in electrochemical analysis", Talanta, vol. 82, pp. 1588-1593, 2010.
    • (2010) Talanta , vol.82 , pp. 1588-1593
    • Saraji, M.1    Farajmand, B.2    Ensafi, A.A.3    Allafchian, A.R.4    Mirahmdi-Zare, Z.5
  • 10
    • 0031811595 scopus 로고    scopus 로고
    • Quantitative determination of tricyclic antidepressants and their metabolites in plasma by solid-phase extraction (Bond-Elut TCA) and separation by capillary gas chromatography with nitrogen-phosphorous detection
    • DOI 10.1097/00007691-199806000-00017
    • D. Torre, R. Ortuno, J. Pascual, J. A. González, and S. B. Jordi, "Quantitative determination of tricyclic antidepressants and their metabolites in plasma by solid-phase extraction (bond-elut tca) and separation by capillary gas chromatography with nitrogen-phosphorous detection", J. Therap. Drug Monitoring, vol. 20, pp. 340-346, 1998. (Pubitemid 28248857)
    • (1998) Therapeutic Drug Monitoring , vol.20 , Issue.3 , pp. 340-346
    • De La Torre, R.1    Ortuno, J.2    Pascual, J.A.3    Gonzalez, S.4    Ballesta, J.5
  • 11
    • 33748329479 scopus 로고    scopus 로고
    • Ion-selective electrode for the determination of some multidrug resistance reversers
    • DOI 10.1016/j.snb.2005.12.021, PII S0925400505009846
    • J. A. Ortuno, J. Hernandez, and C. Sanchez-Pedreno, "Ion-selective electrode for the determination of some multidrug resistance reversers", Sens. Actuators B, vol. 119, pp. 282-287, 2006. (Pubitemid 44332067)
    • (2006) Sensors and Actuators, B: Chemical , vol.119 , Issue.1 , pp. 282-287
    • Ortuno, J.A.1    Hernandez, J.2    Sanchez-Pedreno, C.3
  • 12
    • 70549109054 scopus 로고    scopus 로고
    • Drug selective poly (vinyl chloride)-based sensor of desipramine hydrochloride
    • V. K. Gupta, M. K. Pal, and A. K. Singh, "Drug selective poly (vinyl chloride)-based sensor of desipramine hydrochloride", Electrochimica Acta, vol. 55, pp. 1061-1066, 2010.
    • (2010) Electrochimica Acta , vol.55 , pp. 1061-1066
    • Gupta, V.K.1    Pal, M.K.2    Singh, A.K.3
  • 13
    • 44749086292 scopus 로고    scopus 로고
    • Novel and selective potentiometric membrane sensor for amiloride determination in pharmaceutical compounds and urine
    • A. A. Ensafi and A. R. Allafchian, "Novel and selective potentiometric membrane sensor for amiloride determination in pharmaceutical compounds and urine", J. Pharm. Biomed. Anal., vol. 47, pp. 802-806, 2008.
    • (2008) J. Pharm. Biomed. Anal. , vol.47 , pp. 802-806
    • Ensafi, A.A.1    Allafchian, A.R.2
  • 14
    • 85022266459 scopus 로고
    • Plastic electrodes specific for organic ions
    • T. Higuchi, C. R. Illian, and J. L. Tossounian, "Plastic electrodes specific for organic ions", Anal. Chem., vol. 42, pp. 1674-1676, 1970.
    • (1970) Anal. Chem. , vol.42 , pp. 1674-1676
    • Higuchi, T.1    Illian, C.R.2    Tossounian, J.L.3
  • 15
    • 0034105466 scopus 로고    scopus 로고
    • Relationship between the hydrophobicity of cations and the cationic response of a plasticized poly (vinyl chloride) membrane electrode with no added ionexchanger
    • T. Masadome, T. Imato, S. I. Wakida, K. Higashi, and Y. Asano, "Relationship between the hydrophobicity of cations and the cationic response of a plasticized poly (vinyl chloride) membrane electrode with no added ionexchanger", Anal. Sci., vol. 16, pp. 383-389, 2000.
    • (2000) Anal. Sci. , vol.16 , pp. 383-389
    • Masadome, T.1    Imato, T.2    Wakida, S.I.3    Higashi, K.4    Asano, Y.5
  • 16
    • 60849087359 scopus 로고    scopus 로고
    • Rapid determination of pentazocine in human plasma and urine by a potentiometric method
    • A. R. Allafchian, A. A. Ensafi, and M. Saraji, "Rapid determination of pentazocine in human plasma and urine by a potentiometric method", Anal. Lett., vol. 42, pp. 571-583, 2009.
    • (2009) Anal. Lett. , vol.42 , pp. 571-583
    • Allafchian, A.R.1    Ensafi, A.A.2    Saraji, M.3
  • 17
    • 0022347746 scopus 로고
    • Construction of ion-selective electrodes for chlorpromazine, amitriptyline, propantheline and meperidine: Analytical study and application to pharmaceutical analysis
    • DOI 10.1039/an9851001091
    • A. Mitsana-Papazoglou, T. K. Christopoulos, E. P. Diamandis, and T. P. Hadjiioannou, "Construction of ion-selective electrodes for chlorpromazine, amitriptyline, propantheline and meperidine: Analytical study and application to pharmaceutical analysis", Analyst, vol. 110, pp. 1091-1094, 1985. (Pubitemid 16243109)
    • (1985) Analyst , vol.110 , Issue.9 , pp. 1091-1094
    • Mitsana-Papazoglou, A.1    Christopoulos, T.K.2    Diamandis, E.P.3    Hadjiioannou, T.P.4
  • 18
    • 0010480659 scopus 로고
    • New ampicillin selective plastic membrane and coated metal electrodes based on ampicillinium phosphotungstate ion pair
    • M. S. Rizk, Y. M. Issa, A. F. Shoukry, and M. M. Abdel-Aal, "New ampicillin selective plastic membrane and coated metal electrodes based on ampicillinium phosphotungstate ion pair", Anal. Lett., vol. 27, pp. 1055-1065, 1994.
    • (1994) Anal. Lett. , vol.27 , pp. 1055-1065
    • Rizk, M.S.1    Issa, Y.M.2    Shoukry, A.F.3    Abdel-Aal, M.M.4
  • 19
    • 0000028044 scopus 로고    scopus 로고
    • Diphenhydramine-selective plastic membrane sensor and its pharmaceutical applications
    • A. Erdem, M. Ozsoz, L. Kirilmaz, E. Kilinc, and T. Dalbasti, "Diphenhydramine-selective plastic membrane sensor and its pharmaceutical applications", Electroanalysis, vol. 9, pp. 932-935, 2005.
    • (2005) Electroanalysis , vol.9 , pp. 932-935
    • Erdem, A.1    Ozsoz, M.2    Kirilmaz, L.3    Kilinc, E.4    Dalbasti, T.5
  • 20
    • 0024428589 scopus 로고
    • The use of ion-selective electrodes in the determination of drug substances
    • DOI 10.1016/0731-7085(89)80001-9
    • K. Vytras, "The use of ion-selective electrodes in the determination of drug substances", J. Pharm. Biomed. Anal., vol. 7, pp. 789-812, 1989. (Pubitemid 19249573)
    • (1989) Journal of Pharmaceutical and Biomedical Analysis , vol.7 , Issue.7 , pp. 789-812
    • Vytras, K.1
  • 21
    • 0021850821 scopus 로고
    • Potentiometric titrations based on ion-pair formation
    • K. Vytras, "Potentiometric titrations based on ion-pair formation", Ion-Sel. Electrode Rev., vol. 7, pp. 77-164, 1985. (Pubitemid 15527320)
    • (1985) Ion-selective electrode reviews , vol.7 , Issue.1 , pp. 77-164
    • Vytras, K.1
  • 22
    • 0032369382 scopus 로고    scopus 로고
    • Validation criteria for developing ionselective membrane electrodes for analysis ofpharmaceuticals
    • R. Stefan and H. Y. Aboul-Enein, "Validation criteria for developing ionselective membrane electrodes for analysis ofpharmaceuticals", Accred. Qual. Assur., vol. 3, pp. 194-196, 1998.
    • (1998) Accred. Qual. Assur. , vol.3 , pp. 194-196
    • Stefan, R.1    Aboul-Enein, H.Y.2
  • 23
    • 46549096850 scopus 로고
    • Lipophilic salts as membrane additives and their influence on the properties of macro-and micro-electrodes based on neutral carriers
    • D. Ammann, E. Pretsch, W. Simon, E. Lindner, A. Bezegh, and E. Pungor, "Lipophilic salts as membrane additives and their influence on the properties of macro-and micro-electrodes based on neutral carriers", Anal. Chim. Acta, vol. 171, pp. 119-129, 1985.
    • (1985) Anal. Chim. Acta , vol.171 , pp. 119-129
    • Ammann, D.1    Pretsch, E.2    Simon, W.3    Lindner, E.4    Bezegh, A.5    Pungor, E.6
  • 24
    • 0019008094 scopus 로고
    • Life time of neutral carrier based ion selective liquid-membrane electrodes
    • U. Oesch and W. Simon, "Life time of neutral carrier based ion selective liquid-membrane electrodes", Anal. Chem., vol. 52, pp. 962-700, 1980.
    • (1980) Anal. Chem. , vol.52 , pp. 962-700
    • Oesch, U.1    Simon, W.2
  • 25
    • 0031592861 scopus 로고    scopus 로고
    • Partitioning of local anesthetic dibucaine into bilayer membranes of dimyristoylphosphatidylcholine
    • DOI 10.1016/S0927-7765(97)00043-X, PII S092777659700043X
    • S. Kaneshina, H. Satake, T. Yamamoto, Y. Kume, and H. Matsukia, "Partitioning of local anesthetic dibucaine into bilayer membranes of dimyristoylphosphatidylcholine", Colloids and Surfaces B: Biointerfaces, vol. 10, pp. 51-57, 1997. (Pubitemid 28075450)
    • (1997) Colloids and Surfaces B: Biointerfaces , vol.10 , Issue.1 , pp. 51-57
    • Kaneshina, S.1    Satake, H.2    Yamamoto, T.3    Kume, Y.4    Matsuki, H.5
  • 26
    • 0002670068 scopus 로고
    • Serum albumin structure and characterization of its ligand binding sites
    • P. C. Jost and O. H. Griffith, Eds. New York: John Wiley
    • J. R. Brown and P. Shockley, Serum Albumin Structure and Characterization of its Ligand Binding Sites in "Lipid-Protein Interactions", P. C. Jost and O. H. Griffith, Eds. New York: John Wiley, 1982, pp. 25-68.
    • (1982) Lipid-protein Interactions , pp. 25-68
    • Brown, J.R.1    Shockley, P.2
  • 27
    • 0037201660 scopus 로고    scopus 로고
    • Drug-selective electrode for ketamine determination in pharmaceutical preparations and electrochemical study of drug with BSA
    • DOI 10.1016/S0731-7085(02)00350-3, PII S0731708502003503
    • N. Alizadeh and R. Mehdipour, "Drug-selective electrode for ketamine determination in pharmaceutical preparations and electrochemical study of drug with BSA", J. Pharm. Biomed. Anal., vol. 30, pp. 725-731, 2002. (Pubitemid 35279698)
    • (2002) Journal of Pharmaceutical and Biomedical Analysis , vol.30 , Issue.3 , pp. 725-731
    • Alizadeh, N.1    Mehdipour, R.2
  • 28
    • 0002647656 scopus 로고    scopus 로고
    • Electrochemical Study of the Micellization of Hexadecylpyridinium Bromide in the Presence of Some Crown Ethers
    • M. Shamsipur, N. Alizadeh, H. Gharibi, and M. F. Mousavi, "Electrochemical study of the micellization of hexadecylpyridium bromide in the presence of some crown ethers", J. Chin. Chem. Soc., vol. 44, pp. 9-15, 1997. (Pubitemid 127441996)
    • (1997) Journal of the Chinese Chemical Society , vol.44 , Issue.1 , pp. 9-15
    • Shamsipur, M.1    Alizadeh, N.2    Gharibi, H.3    Mousavi, M.F.4
  • 29
    • 0023746489 scopus 로고
    • Decrease in stability of human albumin with increase in protein concentration
    • P. D. Ross and A. Shrake, "Decrease in stability of human albumin with increase in protein concentration", J. Biol. Chem., vol. 263, pp. 11196-11202, 1988.
    • (1988) J. Biol. Chem. , vol.263 , pp. 11196-11202
    • Ross, P.D.1    Shrake, A.2
  • 30
    • 0001285423 scopus 로고    scopus 로고
    • Binding of n-alkyl sulphates to lysozyme in aqueous solution
    • M. N. Jones and P. Manley, "Binding of n-alkyl sulphates to lysozyme in aqueous solution", J. Chem. Soc., vol. 75, pp. 1736-1744, 1997.
    • (1997) J. Chem. Soc. , vol.75 , pp. 1736-1744
    • Jones, M.N.1    Manley, P.2
  • 31
    • 80052055498 scopus 로고    scopus 로고
    • Online. Available:, Oct. 2
    • [Online]. Available: http://en. wikipedia.org/wiki/Hill-equation Oct. 2, 2010.
    • (2010)
  • 33
    • 12344301274 scopus 로고    scopus 로고
    • 2,2′-Bipyridine as a new and sensitive spectrophotometric reagent for the determination of nanoamounts of certain dibenzazepine class of tricyclic antidepressant drugs
    • DOI 10.1016/j.farmac.2004.04.011, PII S0014827X04002113
    • A. Syeda, H. R. K. Mahesh, and A. A. Syed, "2, 2'-Bipyridine as a new and sensitive spectrophotometric reagent for the determination of nanoamounts of certain dibenzazepine class of tricyclic antidepressant drugs", Farmaco, vol. 60, pp. 47-51, 2005. (Pubitemid 40126289)
    • (2005) Farmaco , vol.60 , Issue.1 , pp. 47-51
    • Syeda, A.1    Mahesh, H.R.K.2    Syed, A.A.3
  • 34
    • 0036073826 scopus 로고    scopus 로고
    • Spectrophotometric determination of some antidepressant drugs
    • DOI 10.1081/AL-120005970
    • W. Misiuk and H. Puzanowska-Tarasiewicz, "Spectrophotometric determination of some antidepressant drugs", Anal. Lett., vol. 35, pp. 1163-1170, 2002. (Pubitemid 34804039)
    • (2002) Analytical Letters , vol.35 , Issue.7 , pp. 1163-1170
    • Misiuk, W.1    Puzanowska-Tarasiewicz, H.2
  • 35
    • 0034682296 scopus 로고    scopus 로고
    • Highly selective and sensitive determination of tricyclic antidepressants in human plasma using high-performance liquid chromatography with post-column tris(2,2'-bipyridyl) ruthenium(III) chemiluminescence detection
    • DOI 10.1016/S0003-2670(00)00788-1, PII S0003267000007881
    • H. Yoshida, K. Hidaka, J. Ishida, K. Yoshikuni, H. Nohta, and M. Yamaguchi, "Highly selective and sensitive determination of tricyclic antidepressants in human plasma using high-performance liquid chromatography with post-column tris (2, 2'-bipyridyl) ruthenium (III) chemiluminescence detection", Anal. Chim. Acta, vol. 413, pp. 137-145, 2000. (Pubitemid 30224724)
    • (2000) Analytica Chimica Acta , vol.413 , Issue.1-2 , pp. 137-145
    • Yoshida, H.1    Hidaka, K.2    Ishida, J.3    Yoshikuni, K.4    Nohta, H.5    Yamaguchi, M.6
  • 36
    • 0030955635 scopus 로고    scopus 로고
    • Simultaneous determination of imipramine, desipramine and their 2- and 10-hydroxylated metabolites in human plasma and urine
    • DOI 10.1016/S0378-4347(97)00053-4, PII S0378434797000534
    • A. G. Chen, Y. K. Wing, H. Chiu, S. Lee, C. N. Chen, and K. Chan, "Simultaneous determination of imipramine, desipramine and their 2-and 10-hydroxylated metabolites in human plasma and urine by highperformance liquid chromatography", J. Chromatogr. B: Biomed. Sci. Appl., vol. 693, pp. 153-158, 1997. (Pubitemid 27229627)
    • (1997) Journal of Chromatography B: Biomedical Applications , vol.693 , Issue.1 , pp. 153-158
    • Chen, A.G.1    Wing, Y.K.2    Chiu, H.3    Lee, S.4    Chen, C.N.5    Chan, K.6
  • 37
    • 4944243744 scopus 로고    scopus 로고
    • Method for simultaneous determination of eight cyclic antidepressants by cyclodextrin-modified capillary zone electrophoresis: Applications in pharmaceuticals
    • H. S. Kou, C. C. Chen, Y. H. Huang, W. K. Ko, and H. L. Wu, "Method for simultaneous determination of eight cyclic antidepressants by cyclodextrin-modified capillary zone electrophoresis: Applications in pharmaceuticals", Anal. Chim. Acta, vol. 525, pp. 23-30, 2004.
    • (2004) Anal. Chim. Acta , vol.525 , pp. 23-30
    • Kou, H.S.1    Chen, C.C.2    Huang, Y.H.3    Ko, W.K.4    Wu, H.L.5
  • 38
    • 0022719038 scopus 로고
    • Voltammetric measurement of tricyclic antidepressants following interfacial accumulation at carbon electrodes
    • J. Wang, M. Bonakdar, and C. Morgan, "Voltammetric measurement of tricyclic antidepressants following interfacial accumulation at carbon electrodes", Anal. Chem., vol. 58, pp. 1024-1028, 1986. (Pubitemid 16119332)
    • (1986) Analytical Chemistry , vol.58 , Issue.6 , pp. 1024-1028
    • Wang, J.1    Bonakdar, M.2    Morgan, C.3
  • 39
    • 84963253719 scopus 로고
    • Electrochemical determination of tricyclic antidepressants
    • E. S. Smotkin, G. B. Martin, and G. A. Rechnitz, "Electrochemical determination of tricyclic antidepressants", Anal. Lett., vol. 24, pp. 798-808, 1991.
    • (1991) Anal. Lett. , vol.24 , pp. 798-808
    • Smotkin, E.S.1    Martin, G.B.2    Rechnitz, G.A.3
  • 40
    • 77956145532 scopus 로고    scopus 로고
    • Combined hollow fiber-based liquid-liquid-liquid microextraction and in-situ differential pulse voltammetry to improve selectivity, sensitivity, and interference elimination in electrochemical analysis
    • M. Saraji, B. Farajmand, A. A. Ensafi, A. R. Allafchian, and Z. Mirahmdi-Zare, "Combined hollow fiber-based liquid-liquid-liquid microextraction and in-situ differential pulse voltammetry to improve selectivity, sensitivity, and interference elimination in electrochemical analysis", Talanta, vol. 82, pp. 1588-1593, 2010.
    • (2010) Talanta , vol.82 , pp. 1588-1593
    • Saraji, M.1    Farajmand, B.2    Ensafi, A.A.3    Allafchian, A.R.4    Mirahmdi-Zare, Z.5
  • 41
    • 0031811595 scopus 로고    scopus 로고
    • Quantitative determination of tricyclic antidepressants and their metabolites in plasma by solid-phase extraction (Bond-Elut TCA) and separation by capillary gas chromatography with nitrogen-phosphorous detection
    • DOI 10.1097/00007691-199806000-00017
    • D. Torre, R. Ortuno, J. Pascual, J. A. González, and S. B. Jordi, "Quantitative determination of tricyclic antidepressants and their metabolites in plasma by solid-phase extraction (bond-elut tca) and separation by capillary gas chromatography with nitrogen-phosphorous detection", J. Therap. Drug Monitoring, vol. 20, pp. 340-346, 1998. (Pubitemid 28248857)
    • (1998) Therapeutic Drug Monitoring , vol.20 , Issue.3 , pp. 340-346
    • De La Torre, R.1    Ortuno, J.2    Pascual, J.A.3    Gonzalez, S.4    Ballesta, J.5
  • 42
    • 33748329479 scopus 로고    scopus 로고
    • Ion-selective electrode for the determination of some multidrug resistance reversers
    • DOI 10.1016/j.snb.2005.12.021, PII S0925400505009846
    • J. A. Ortuno, J. Hernandez, and C. Sanchez-Pedreno, "Ion-selective electrode for the determination of some multidrug resistance reversers", Sens. Actuators B, vol. 119, pp. 282-287, 2006. (Pubitemid 44332067)
    • (2006) Sensors and Actuators, B: Chemical , vol.119 , Issue.1 , pp. 282-287
    • Ortuno, J.A.1    Hernandez, J.2    Sanchez-Pedreno, C.3
  • 43
    • 70549109054 scopus 로고    scopus 로고
    • Drug selective poly (vinyl chloride)-based sensor of desipramine hydrochloride
    • V. K. Gupta, M. K. Pal, and A. K. Singh, "Drug selective poly (vinyl chloride)-based sensor of desipramine hydrochloride", Electrochimica Acta, vol. 55, pp. 1061-1066, 2010.
    • (2010) Electrochimica Acta , vol.55 , pp. 1061-1066
    • Gupta, V.K.1    Pal, M.K.2    Singh, A.K.3
  • 44
    • 44749086292 scopus 로고    scopus 로고
    • Novel and selective potentiometric membrane sensor for amiloride determination in pharmaceutical compounds and urine
    • A. A. Ensafi and A. R. Allafchian, "Novel and selective potentiometric membrane sensor for amiloride determination in pharmaceutical compounds and urine", J. Pharm. Biomed. Anal., vol. 47, pp. 802-806, 2008.
    • (2008) J. Pharm. Biomed. Anal. , vol.47 , pp. 802-806
    • Ensafi, A.A.1    Allafchian, A.R.2
  • 45
    • 85022266459 scopus 로고
    • Plastic electrodes specific for organic ions
    • T. Higuchi, C. R. Illian, and J. L. Tossounian, "Plastic electrodes specific for organic ions", Anal. Chem., vol. 42, pp. 1674-1676, 1970.
    • (1970) Anal. Chem. , vol.42 , pp. 1674-1676
    • Higuchi, T.1    Illian, C.R.2    Tossounian, J.L.3
  • 46
    • 0034105466 scopus 로고    scopus 로고
    • Relationship between the hydrophobicity of cations and the cationic response of a plasticized poly (vinyl chloride) membrane electrode with no added ionexchanger
    • T. Masadome, T. Imato, S. I. Wakida, K. Higashi, and Y. Asano, "Relationship between the hydrophobicity of cations and the cationic response of a plasticized poly (vinyl chloride) membrane electrode with no added ionexchanger", Anal. Sci., vol. 16, pp. 383-389, 2000.
    • (2000) Anal. Sci. , vol.16 , pp. 383-389
    • Masadome, T.1    Imato, T.2    Wakida, S.I.3    Higashi, K.4    Asano, Y.5
  • 47
    • 60849087359 scopus 로고    scopus 로고
    • Rapid determination of pentazocine in human plasma and urine by a potentiometric method
    • A. R. Allafchian, A. A. Ensafi, and M. Saraji, "Rapid determination of pentazocine in human plasma and urine by a potentiometric method", Anal. Lett., vol. 42, pp. 571-583, 2009.
    • (2009) Anal. Lett. , vol.42 , pp. 571-583
    • Allafchian, A.R.1    Ensafi, A.A.2    Saraji, M.3
  • 48
    • 0022347746 scopus 로고
    • Construction of ion-selective electrodes for chlorpromazine, amitriptyline, propantheline and meperidine: Analytical study and application to pharmaceutical analysis
    • DOI 10.1039/an9851001091
    • A. Mitsana-Papazoglou, T. K. Christopoulos, E. P. Diamandis, and T. P. Hadjiioannou, "Construction of ion-selective electrodes for chlorpromazine, amitriptyline, propantheline and meperidine: Analytical study and application to pharmaceutical analysis", Analyst, vol. 110, pp. 1091-1094, 1985. (Pubitemid 16243109)
    • (1985) Analyst , vol.110 , Issue.9 , pp. 1091-1094
    • Mitsana-Papazoglou, A.1    Christopoulos, T.K.2    Diamandis, E.P.3    Hadjiioannou, T.P.4
  • 49
    • 0010480659 scopus 로고
    • New ampicillin selective plastic membrane and coated metal electrodes based on ampicillinium phosphotungstate ion pair
    • M. S. Rizk, Y. M. Issa, A. F. Shoukry, and M. M. Abdel-Aal, "New ampicillin selective plastic membrane and coated metal electrodes based on ampicillinium phosphotungstate ion pair", Anal. Lett., vol. 27, pp. 1055-1065, 1994.
    • (1994) Anal. Lett. , vol.27 , pp. 1055-1065
    • Rizk, M.S.1    Issa, Y.M.2    Shoukry, A.F.3    Abdel-Aal, M.M.4
  • 50
    • 0000028044 scopus 로고    scopus 로고
    • Diphenhydramine-selective plastic membrane sensor and its pharmaceutical applications
    • A. Erdem, M. Ozsoz, L. Kirilmaz, E. Kilinc, and T. Dalbasti, "Diphenhydramine-selective plastic membrane sensor and its pharmaceutical applications", Electroanalysis, vol. 9, pp. 932-935, 2005.
    • (2005) Electroanalysis , vol.9 , pp. 932-935
    • Erdem, A.1    Ozsoz, M.2    Kirilmaz, L.3    Kilinc, E.4    Dalbasti, T.5
  • 51
    • 0024428589 scopus 로고
    • The use of ion-selective electrodes in the determination of drug substances
    • DOI 10.1016/0731-7085(89)80001-9
    • K. Vytras, "The use of ion-selective electrodes in the determination of drug substances", J. Pharm. Biomed. Anal., vol. 7, pp. 789-812, 1989. (Pubitemid 19249573)
    • (1989) Journal of Pharmaceutical and Biomedical Analysis , vol.7 , Issue.7 , pp. 789-812
    • Vytras, K.1
  • 52
    • 0021850821 scopus 로고
    • Potentiometric titrations based on ion-pair formation
    • K. Vytras, "Potentiometric titrations based on ion-pair formation", Ion-Sel. Electrode Rev., vol. 7, pp. 77-164, 1985. (Pubitemid 15527320)
    • (1985) Ion-selective electrode reviews , vol.7 , Issue.1 , pp. 77-164
    • Vytras, K.1
  • 53
    • 0032369382 scopus 로고    scopus 로고
    • Validation criteria for developing ionselective membrane electrodes for analysis ofpharmaceuticals
    • R. Stefan and H. Y. Aboul-Enein, "Validation criteria for developing ionselective membrane electrodes for analysis ofpharmaceuticals", Accred. Qual. Assur., vol. 3, pp. 194-196, 1998.
    • (1998) Accred. Qual. Assur. , vol.3 , pp. 194-196
    • Stefan, R.1    Aboul-Enein, H.Y.2
  • 54
    • 46549096850 scopus 로고
    • Lipophilic salts as membrane additives and their influence on the properties of macro-and micro-electrodes based on neutral carriers
    • D. Ammann, E. Pretsch, W. Simon, E. Lindner, A. Bezegh, and E. Pungor, "Lipophilic salts as membrane additives and their influence on the properties of macro-and micro-electrodes based on neutral carriers", Anal. Chim. Acta, vol. 171, pp. 119-129, 1985.
    • (1985) Anal. Chim. Acta , vol.171 , pp. 119-129
    • Ammann, D.1    Pretsch, E.2    Simon, W.3    Lindner, E.4    Bezegh, A.5    Pungor, E.6
  • 55
    • 0019008094 scopus 로고
    • Life time of neutral carrier based ion selective liquid-membrane electrodes
    • U. Oesch and W. Simon, "Life time of neutral carrier based ion selective liquid-membrane electrodes", Anal. Chem., vol. 52, pp. 962-700, 1980.
    • (1980) Anal. Chem. , vol.52 , pp. 962-700
    • Oesch, U.1    Simon, W.2
  • 56
    • 0031592861 scopus 로고    scopus 로고
    • Partitioning of local anesthetic dibucaine into bilayer membranes of dimyristoylphosphatidylcholine
    • DOI 10.1016/S0927-7765(97)00043-X, PII S092777659700043X
    • S. Kaneshina, H. Satake, T. Yamamoto, Y. Kume, and H. Matsukia, "Partitioning of local anesthetic dibucaine into bilayer membranes of dimyristoylphosphatidylcholine", Colloids and Surfaces B: Biointerfaces, vol. 10, pp. 51-57, 1997. (Pubitemid 28075450)
    • (1997) Colloids and Surfaces B: Biointerfaces , vol.10 , Issue.1 , pp. 51-57
    • Kaneshina, S.1    Satake, H.2    Yamamoto, T.3    Kume, Y.4    Matsuki, H.5
  • 57
    • 0002670068 scopus 로고
    • Serum albumin structure and characterization of its ligand binding sites
    • P. C. Jost and O. H. Griffith, Eds. New York: John Wiley
    • J. R. Brown and P. Shockley, Serum Albumin Structure and Characterization of its Ligand Binding Sites in "Lipid-Protein Interactions", P. C. Jost and O. H. Griffith, Eds. New York: John Wiley, 1982, pp. 25-68.
    • (1982) Lipid-protein Interactions , pp. 25-68
    • Brown, J.R.1    Shockley, P.2
  • 58
    • 0037201660 scopus 로고    scopus 로고
    • Drug-selective electrode for ketamine determination in pharmaceutical preparations and electrochemical study of drug with BSA
    • DOI 10.1016/S0731-7085(02)00350-3, PII S0731708502003503
    • N. Alizadeh and R. Mehdipour, "Drug-selective electrode for ketamine determination in pharmaceutical preparations and electrochemical study of drug with BSA", J. Pharm. Biomed. Anal., vol. 30, pp. 725-731, 2002. (Pubitemid 35279698)
    • (2002) Journal of Pharmaceutical and Biomedical Analysis , vol.30 , Issue.3 , pp. 725-731
    • Alizadeh, N.1    Mehdipour, R.2
  • 59
    • 0002647656 scopus 로고    scopus 로고
    • Electrochemical Study of the Micellization of Hexadecylpyridinium Bromide in the Presence of Some Crown Ethers
    • M. Shamsipur, N. Alizadeh, H. Gharibi, and M. F. Mousavi, "Electrochemical study of the micellization of hexadecylpyridium bromide in the presence of some crown ethers", J. Chin. Chem. Soc., vol. 44, pp. 9-15, 1997. (Pubitemid 127441996)
    • (1997) Journal of the Chinese Chemical Society , vol.44 , Issue.1 , pp. 9-15
    • Shamsipur, M.1    Alizadeh, N.2    Gharibi, H.3    Mousavi, M.F.4
  • 60
    • 0023746489 scopus 로고
    • Decrease in stability of human albumin with increase in protein concentration
    • P. D. Ross and A. Shrake, "Decrease in stability of human albumin with increase in protein concentration", J. Biol. Chem., vol. 263, pp. 11196-11202, 1988.
    • (1988) J. Biol. Chem. , vol.263 , pp. 11196-11202
    • Ross, P.D.1    Shrake, A.2
  • 61
    • 0001285423 scopus 로고    scopus 로고
    • Binding of n-alkyl sulphates to lysozyme in aqueous solution
    • M. N. Jones and P. Manley, "Binding of n-alkyl sulphates to lysozyme in aqueous solution", J. Chem. Soc., vol. 75, pp. 1736-1744, 1997.
    • (1997) J. Chem. Soc. , vol.75 , pp. 1736-1744
    • Jones, M.N.1    Manley, P.2
  • 62
    • 80052043728 scopus 로고    scopus 로고
    • Online. Available:, Oct. 2
    • [Online]. Available: http://en. wikipedia.org/wiki/Hill-equation Oct. 2, 2010.
    • (2010)
  • 64
    • 12344301274 scopus 로고    scopus 로고
    • 2,2′-Bipyridine as a new and sensitive spectrophotometric reagent for the determination of nanoamounts of certain dibenzazepine class of tricyclic antidepressant drugs
    • DOI 10.1016/j.farmac.2004.04.011, PII S0014827X04002113
    • A. Syeda, H. R. K. Mahesh, and A. A. Syed, "2, 2'-Bipyridine as a new and sensitive spectrophotometric reagent for the determination of nanoamounts of certain dibenzazepine class of tricyclic antidepressant drugs", Farmaco, vol. 60, pp. 47-51, 2005. (Pubitemid 40126289)
    • (2005) Farmaco , vol.60 , Issue.1 , pp. 47-51
    • Syeda, A.1    Mahesh, H.R.K.2    Syed, A.A.3
  • 65
    • 0036073826 scopus 로고    scopus 로고
    • Spectrophotometric determination of some antidepressant drugs
    • DOI 10.1081/AL-120005970
    • W. Misiuk and H. Puzanowska-Tarasiewicz, "Spectrophotometric determination of some antidepressant drugs", Anal. Lett., vol. 35, pp. 1163-1170, 2002. (Pubitemid 34804039)
    • (2002) Analytical Letters , vol.35 , Issue.7 , pp. 1163-1170
    • Misiuk, W.1    Puzanowska-Tarasiewicz, H.2
  • 66
    • 0034682296 scopus 로고    scopus 로고
    • Highly selective and sensitive determination of tricyclic antidepressants in human plasma using high-performance liquid chromatography with post-column tris(2,2'-bipyridyl) ruthenium(III) chemiluminescence detection
    • DOI 10.1016/S0003-2670(00)00788-1, PII S0003267000007881
    • H. Yoshida, K. Hidaka, J. Ishida, K. Yoshikuni, H. Nohta, and M. Yamaguchi, "Highly selective and sensitive determination of tricyclic antidepressants in human plasma using high-performance liquid chromatography with post-column tris (2, 2'-bipyridyl) ruthenium (III) chemiluminescence detection", Anal. Chim. Acta, vol. 413, pp. 137-145, 2000. (Pubitemid 30224724)
    • (2000) Analytica Chimica Acta , vol.413 , Issue.1-2 , pp. 137-145
    • Yoshida, H.1    Hidaka, K.2    Ishida, J.3    Yoshikuni, K.4    Nohta, H.5    Yamaguchi, M.6
  • 67
    • 0030955635 scopus 로고    scopus 로고
    • Simultaneous determination of imipramine, desipramine and their 2- and 10-hydroxylated metabolites in human plasma and urine
    • DOI 10.1016/S0378-4347(97)00053-4, PII S0378434797000534
    • A. G. Chen, Y. K. Wing, H. Chiu, S. Lee, C. N. Chen, and K. Chan, "Simultaneous determination of imipramine, desipramine and their 2-and 10-hydroxylated metabolites in human plasma and urine by highperformance liquid chromatography", J. Chromatogr. B: Biomed. Sci. Appl., vol. 693, pp. 153-158, 1997. (Pubitemid 27229627)
    • (1997) Journal of Chromatography B: Biomedical Applications , vol.693 , Issue.1 , pp. 153-158
    • Chen, A.G.1    Wing, Y.K.2    Chiu, H.3    Lee, S.4    Chen, C.N.5    Chan, K.6
  • 68
    • 4944243744 scopus 로고    scopus 로고
    • Method for simultaneous determination of eight cyclic antidepressants by cyclodextrin-modified capillary zone electrophoresis: Applications in pharmaceuticals
    • H. S. Kou, C. C. Chen, Y. H. Huang, W. K. Ko, and H. L. Wu, "Method for simultaneous determination of eight cyclic antidepressants by cyclodextrin-modified capillary zone electrophoresis: Applications in pharmaceuticals", Anal. Chim. Acta, vol. 525, pp. 23-30, 2004.
    • (2004) Anal. Chim. Acta , vol.525 , pp. 23-30
    • Kou, H.S.1    Chen, C.C.2    Huang, Y.H.3    Ko, W.K.4    Wu, H.L.5
  • 69
    • 0022719038 scopus 로고
    • Voltammetric measurement of tricyclic antidepressants following interfacial accumulation at carbon electrodes
    • J. Wang, M. Bonakdar, and C. Morgan, "Voltammetric measurement of tricyclic antidepressants following interfacial accumulation at carbon electrodes", Anal. Chem., vol. 58, pp. 1024-1028, 1986. (Pubitemid 16119332)
    • (1986) Analytical Chemistry , vol.58 , Issue.6 , pp. 1024-1028
    • Wang, J.1    Bonakdar, M.2    Morgan, C.3
  • 70
    • 84963253719 scopus 로고
    • Electrochemical determination of tricyclic antidepressants
    • E. S. Smotkin, G. B. Martin, and G. A. Rechnitz, "Electrochemical determination of tricyclic antidepressants", Anal. Lett., vol. 24, pp. 798-808, 1991.
    • (1991) Anal. Lett. , vol.24 , pp. 798-808
    • Smotkin, E.S.1    Martin, G.B.2    Rechnitz, G.A.3
  • 71
    • 77956145532 scopus 로고    scopus 로고
    • Combined hollow fiber-based liquid-liquid-liquid microextraction and in-situ differential pulse voltammetry to improve selectivity, sensitivity, and interference elimination in electrochemical analysis
    • M. Saraji, B. Farajmand, A. A. Ensafi, A. R. Allafchian, and Z. Mirahmdi-Zare, "Combined hollow fiber-based liquid-liquid-liquid microextraction and in-situ differential pulse voltammetry to improve selectivity, sensitivity, and interference elimination in electrochemical analysis", Talanta, vol. 82, pp. 1588-1593, 2010.
    • (2010) Talanta , vol.82 , pp. 1588-1593
    • Saraji, M.1    Farajmand, B.2    Ensafi, A.A.3    Allafchian, A.R.4    Mirahmdi-Zare, Z.5
  • 72
    • 0031811595 scopus 로고    scopus 로고
    • Quantitative determination of tricyclic antidepressants and their metabolites in plasma by solid-phase extraction (Bond-Elut TCA) and separation by capillary gas chromatography with nitrogen-phosphorous detection
    • DOI 10.1097/00007691-199806000-00017
    • D. Torre, R. Ortuno, J. Pascual, J. A. González, and S. B. Jordi, "Quantitative determination of tricyclic antidepressants and their metabolites in plasma by solid-phase extraction (bond-elut tca) and separation by capillary gas chromatography with nitrogen-phosphorous detection", J. Therap. Drug Monitoring, vol. 20, pp. 340-346, 1998. (Pubitemid 28248857)
    • (1998) Therapeutic Drug Monitoring , vol.20 , Issue.3 , pp. 340-346
    • De La Torre, R.1    Ortuno, J.2    Pascual, J.A.3    Gonzalez, S.4    Ballesta, J.5
  • 73
    • 33748329479 scopus 로고    scopus 로고
    • Ion-selective electrode for the determination of some multidrug resistance reversers
    • DOI 10.1016/j.snb.2005.12.021, PII S0925400505009846
    • J. A. Ortuno, J. Hernandez, and C. Sanchez-Pedreno, "Ion-selective electrode for the determination of some multidrug resistance reversers", Sens. Actuators B, vol. 119, pp. 282-287, 2006. (Pubitemid 44332067)
    • (2006) Sensors and Actuators, B: Chemical , vol.119 , Issue.1 , pp. 282-287
    • Ortuno, J.A.1    Hernandez, J.2    Sanchez-Pedreno, C.3
  • 74
    • 70549109054 scopus 로고    scopus 로고
    • Drug selective poly (vinyl chloride)-based sensor of desipramine hydrochloride
    • V. K. Gupta, M. K. Pal, and A. K. Singh, "Drug selective poly (vinyl chloride)-based sensor of desipramine hydrochloride", Electrochimica Acta, vol. 55, pp. 1061-1066, 2010.
    • (2010) Electrochimica Acta , vol.55 , pp. 1061-1066
    • Gupta, V.K.1    Pal, M.K.2    Singh, A.K.3
  • 75
    • 44749086292 scopus 로고    scopus 로고
    • Novel and selective potentiometric membrane sensor for amiloride determination in pharmaceutical compounds and urine
    • A. A. Ensafi and A. R. Allafchian, "Novel and selective potentiometric membrane sensor for amiloride determination in pharmaceutical compounds and urine", J. Pharm. Biomed. Anal., vol. 47, pp. 802-806, 2008.
    • (2008) J. Pharm. Biomed. Anal. , vol.47 , pp. 802-806
    • Ensafi, A.A.1    Allafchian, A.R.2
  • 76
    • 85022266459 scopus 로고
    • Plastic electrodes specific for organic ions
    • T. Higuchi, C. R. Illian, and J. L. Tossounian, "Plastic electrodes specific for organic ions", Anal. Chem., vol. 42, pp. 1674-1676, 1970.
    • (1970) Anal. Chem. , vol.42 , pp. 1674-1676
    • Higuchi, T.1    Illian, C.R.2    Tossounian, J.L.3
  • 77
    • 0034105466 scopus 로고    scopus 로고
    • Relationship between the hydrophobicity of cations and the cationic response of a plasticized poly (vinyl chloride) membrane electrode with no added ionexchanger
    • T. Masadome, T. Imato, S. I. Wakida, K. Higashi, and Y. Asano, "Relationship between the hydrophobicity of cations and the cationic response of a plasticized poly (vinyl chloride) membrane electrode with no added ionexchanger", Anal. Sci., vol. 16, pp. 383-389, 2000.
    • (2000) Anal. Sci. , vol.16 , pp. 383-389
    • Masadome, T.1    Imato, T.2    Wakida, S.I.3    Higashi, K.4    Asano, Y.5
  • 78
    • 60849087359 scopus 로고    scopus 로고
    • Rapid determination of pentazocine in human plasma and urine by a potentiometric method
    • A. R. Allafchian, A. A. Ensafi, and M. Saraji, "Rapid determination of pentazocine in human plasma and urine by a potentiometric method", Anal. Lett., vol. 42, pp. 571-583, 2009.
    • (2009) Anal. Lett. , vol.42 , pp. 571-583
    • Allafchian, A.R.1    Ensafi, A.A.2    Saraji, M.3
  • 79
    • 0022347746 scopus 로고
    • Construction of ion-selective electrodes for chlorpromazine, amitriptyline, propantheline and meperidine: Analytical study and application to pharmaceutical analysis
    • DOI 10.1039/an9851001091
    • A. Mitsana-Papazoglou, T. K. Christopoulos, E. P. Diamandis, and T. P. Hadjiioannou, "Construction of ion-selective electrodes for chlorpromazine, amitriptyline, propantheline and meperidine: Analytical study and application to pharmaceutical analysis", Analyst, vol. 110, pp. 1091-1094, 1985. (Pubitemid 16243109)
    • (1985) Analyst , vol.110 , Issue.9 , pp. 1091-1094
    • Mitsana-Papazoglou, A.1    Christopoulos, T.K.2    Diamandis, E.P.3    Hadjiioannou, T.P.4
  • 80
    • 0010480659 scopus 로고
    • New ampicillin selective plastic membrane and coated metal electrodes based on ampicillinium phosphotungstate ion pair
    • M. S. Rizk, Y. M. Issa, A. F. Shoukry, and M. M. Abdel-Aal, "New ampicillin selective plastic membrane and coated metal electrodes based on ampicillinium phosphotungstate ion pair", Anal. Lett., vol. 27, pp. 1055-1065, 1994.
    • (1994) Anal. Lett. , vol.27 , pp. 1055-1065
    • Rizk, M.S.1    Issa, Y.M.2    Shoukry, A.F.3    Abdel-Aal, M.M.4
  • 81
    • 0000028044 scopus 로고    scopus 로고
    • Diphenhydramine-selective plastic membrane sensor and its pharmaceutical applications
    • A. Erdem, M. Ozsoz, L. Kirilmaz, E. Kilinc, and T. Dalbasti, "Diphenhydramine-selective plastic membrane sensor and its pharmaceutical applications", Electroanalysis, vol. 9, pp. 932-935, 2005.
    • (2005) Electroanalysis , vol.9 , pp. 932-935
    • Erdem, A.1    Ozsoz, M.2    Kirilmaz, L.3    Kilinc, E.4    Dalbasti, T.5
  • 82
    • 0024428589 scopus 로고
    • The use of ion-selective electrodes in the determination of drug substances
    • DOI 10.1016/0731-7085(89)80001-9
    • K. Vytras, "The use of ion-selective electrodes in the determination of drug substances", J. Pharm. Biomed. Anal., vol. 7, pp. 789-812, 1989. (Pubitemid 19249573)
    • (1989) Journal of Pharmaceutical and Biomedical Analysis , vol.7 , Issue.7 , pp. 789-812
    • Vytras, K.1
  • 83
    • 0021850821 scopus 로고
    • Potentiometric titrations based on ion-pair formation
    • K. Vytras, "Potentiometric titrations based on ion-pair formation", Ion-Sel. Electrode Rev., vol. 7, pp. 77-164, 1985. (Pubitemid 15527320)
    • (1985) Ion-selective electrode reviews , vol.7 , Issue.1 , pp. 77-164
    • Vytras, K.1
  • 84
    • 0032369382 scopus 로고    scopus 로고
    • Validation criteria for developing ionselective membrane electrodes for analysis ofpharmaceuticals
    • R. Stefan and H. Y. Aboul-Enein, "Validation criteria for developing ionselective membrane electrodes for analysis ofpharmaceuticals", Accred. Qual. Assur., vol. 3, pp. 194-196, 1998.
    • (1998) Accred. Qual. Assur. , vol.3 , pp. 194-196
    • Stefan, R.1    Aboul-Enein, H.Y.2
  • 85
    • 46549096850 scopus 로고
    • Lipophilic salts as membrane additives and their influence on the properties of macro-and micro-electrodes based on neutral carriers
    • D. Ammann, E. Pretsch, W. Simon, E. Lindner, A. Bezegh, and E. Pungor, "Lipophilic salts as membrane additives and their influence on the properties of macro-and micro-electrodes based on neutral carriers", Anal. Chim. Acta, vol. 171, pp. 119-129, 1985.
    • (1985) Anal. Chim. Acta , vol.171 , pp. 119-129
    • Ammann, D.1    Pretsch, E.2    Simon, W.3    Lindner, E.4    Bezegh, A.5    Pungor, E.6
  • 86
    • 0019008094 scopus 로고
    • Life time of neutral carrier based ion selective liquid-membrane electrodes
    • U. Oesch and W. Simon, "Life time of neutral carrier based ion selective liquid-membrane electrodes", Anal. Chem., vol. 52, pp. 962-700, 1980.
    • (1980) Anal. Chem. , vol.52 , pp. 962-700
    • Oesch, U.1    Simon, W.2
  • 87
    • 0031592861 scopus 로고    scopus 로고
    • Partitioning of local anesthetic dibucaine into bilayer membranes of dimyristoylphosphatidylcholine
    • DOI 10.1016/S0927-7765(97)00043-X, PII S092777659700043X
    • S. Kaneshina, H. Satake, T. Yamamoto, Y. Kume, and H. Matsukia, "Partitioning of local anesthetic dibucaine into bilayer membranes of dimyristoylphosphatidylcholine", Colloids and Surfaces B: Biointerfaces, vol. 10, pp. 51-57, 1997. (Pubitemid 28075450)
    • (1997) Colloids and Surfaces B: Biointerfaces , vol.10 , Issue.1 , pp. 51-57
    • Kaneshina, S.1    Satake, H.2    Yamamoto, T.3    Kume, Y.4    Matsuki, H.5
  • 88
    • 0002670068 scopus 로고
    • Serum albumin structure and characterization of its ligand binding sites
    • P. C. Jost and O. H. Griffith, Eds. New York: John Wiley
    • J. R. Brown and P. Shockley, Serum Albumin Structure and Characterization of its Ligand Binding Sites in "Lipid-Protein Interactions", P. C. Jost and O. H. Griffith, Eds. New York: John Wiley, 1982, pp. 25-68.
    • (1982) Lipid-protein Interactions , pp. 25-68
    • Brown, J.R.1    Shockley, P.2
  • 89
    • 0037201660 scopus 로고    scopus 로고
    • Drug-selective electrode for ketamine determination in pharmaceutical preparations and electrochemical study of drug with BSA
    • DOI 10.1016/S0731-7085(02)00350-3, PII S0731708502003503
    • N. Alizadeh and R. Mehdipour, "Drug-selective electrode for ketamine determination in pharmaceutical preparations and electrochemical study of drug with BSA", J. Pharm. Biomed. Anal., vol. 30, pp. 725-731, 2002. (Pubitemid 35279698)
    • (2002) Journal of Pharmaceutical and Biomedical Analysis , vol.30 , Issue.3 , pp. 725-731
    • Alizadeh, N.1    Mehdipour, R.2
  • 90
    • 0002647656 scopus 로고    scopus 로고
    • Electrochemical Study of the Micellization of Hexadecylpyridinium Bromide in the Presence of Some Crown Ethers
    • M. Shamsipur, N. Alizadeh, H. Gharibi, and M. F. Mousavi, "Electrochemical study of the micellization of hexadecylpyridium bromide in the presence of some crown ethers", J. Chin. Chem. Soc., vol. 44, pp. 9-15, 1997. (Pubitemid 127441996)
    • (1997) Journal of the Chinese Chemical Society , vol.44 , Issue.1 , pp. 9-15
    • Shamsipur, M.1    Alizadeh, N.2    Gharibi, H.3    Mousavi, M.F.4
  • 91
    • 0023746489 scopus 로고
    • Decrease in stability of human albumin with increase in protein concentration
    • P. D. Ross and A. Shrake, "Decrease in stability of human albumin with increase in protein concentration", J. Biol. Chem., vol. 263, pp. 11196-11202, 1988.
    • (1988) J. Biol. Chem. , vol.263 , pp. 11196-11202
    • Ross, P.D.1    Shrake, A.2
  • 92
    • 0001285423 scopus 로고    scopus 로고
    • Binding of n-alkyl sulphates to lysozyme in aqueous solution
    • M. N. Jones and P. Manley, "Binding of n-alkyl sulphates to lysozyme in aqueous solution", J. Chem. Soc., vol. 75, pp. 1736-1744, 1997.
    • (1997) J. Chem. Soc. , vol.75 , pp. 1736-1744
    • Jones, M.N.1    Manley, P.2
  • 93
    • 80052050553 scopus 로고    scopus 로고
    • Online. Available:, Oct. 2
    • [Online]. Available: http://en. wikipedia.org/wiki/Hill-equation Oct. 2, 2010.
    • (2010)
  • 95
    • 12344301274 scopus 로고    scopus 로고
    • 2,2′-Bipyridine as a new and sensitive spectrophotometric reagent for the determination of nanoamounts of certain dibenzazepine class of tricyclic antidepressant drugs
    • DOI 10.1016/j.farmac.2004.04.011, PII S0014827X04002113
    • A. Syeda, H. R. K. Mahesh, and A. A. Syed, "2, 2'-Bipyridine as a new and sensitive spectrophotometric reagent for the determination of nanoamounts of certain dibenzazepine class of tricyclic antidepressant drugs", Farmaco, vol. 60, pp. 47-51, 2005. (Pubitemid 40126289)
    • (2005) Farmaco , vol.60 , Issue.1 , pp. 47-51
    • Syeda, A.1    Mahesh, H.R.K.2    Syed, A.A.3
  • 96
    • 0036073826 scopus 로고    scopus 로고
    • Spectrophotometric determination of some antidepressant drugs
    • DOI 10.1081/AL-120005970
    • W. Misiuk and H. Puzanowska-Tarasiewicz, "Spectrophotometric determination of some antidepressant drugs", Anal. Lett., vol. 35, pp. 1163-1170, 2002. (Pubitemid 34804039)
    • (2002) Analytical Letters , vol.35 , Issue.7 , pp. 1163-1170
    • Misiuk, W.1    Puzanowska-Tarasiewicz, H.2
  • 97
    • 0034682296 scopus 로고    scopus 로고
    • Highly selective and sensitive determination of tricyclic antidepressants in human plasma using high-performance liquid chromatography with post-column tris(2,2'-bipyridyl) ruthenium(III) chemiluminescence detection
    • DOI 10.1016/S0003-2670(00)00788-1, PII S0003267000007881
    • H. Yoshida, K. Hidaka, J. Ishida, K. Yoshikuni, H. Nohta, and M. Yamaguchi, "Highly selective and sensitive determination of tricyclic antidepressants in human plasma using high-performance liquid chromatography with post-column tris (2, 2'-bipyridyl) ruthenium (III) chemiluminescence detection", Anal. Chim. Acta, vol. 413, pp. 137-145, 2000. (Pubitemid 30224724)
    • (2000) Analytica Chimica Acta , vol.413 , Issue.1-2 , pp. 137-145
    • Yoshida, H.1    Hidaka, K.2    Ishida, J.3    Yoshikuni, K.4    Nohta, H.5    Yamaguchi, M.6
  • 98
    • 0030955635 scopus 로고    scopus 로고
    • Simultaneous determination of imipramine, desipramine and their 2- and 10-hydroxylated metabolites in human plasma and urine
    • DOI 10.1016/S0378-4347(97)00053-4, PII S0378434797000534
    • A. G. Chen, Y. K. Wing, H. Chiu, S. Lee, C. N. Chen, and K. Chan, "Simultaneous determination of imipramine, desipramine and their 2-and 10-hydroxylated metabolites in human plasma and urine by highperformance liquid chromatography", J. Chromatogr. B: Biomed. Sci. Appl., vol. 693, pp. 153-158, 1997. (Pubitemid 27229627)
    • (1997) Journal of Chromatography B: Biomedical Applications , vol.693 , Issue.1 , pp. 153-158
    • Chen, A.G.1    Wing, Y.K.2    Chiu, H.3    Lee, S.4    Chen, C.N.5    Chan, K.6
  • 99
    • 4944243744 scopus 로고    scopus 로고
    • Method for simultaneous determination of eight cyclic antidepressants by cyclodextrin-modified capillary zone electrophoresis: Applications in pharmaceuticals
    • H. S. Kou, C. C. Chen, Y. H. Huang, W. K. Ko, and H. L. Wu, "Method for simultaneous determination of eight cyclic antidepressants by cyclodextrin-modified capillary zone electrophoresis: Applications in pharmaceuticals", Anal. Chim. Acta, vol. 525, pp. 23-30, 2004.
    • (2004) Anal. Chim. Acta , vol.525 , pp. 23-30
    • Kou, H.S.1    Chen, C.C.2    Huang, Y.H.3    Ko, W.K.4    Wu, H.L.5
  • 100
    • 0022719038 scopus 로고
    • Voltammetric measurement of tricyclic antidepressants following interfacial accumulation at carbon electrodes
    • J. Wang, M. Bonakdar, and C. Morgan, "Voltammetric measurement of tricyclic antidepressants following interfacial accumulation at carbon electrodes", Anal. Chem., vol. 58, pp. 1024-1028, 1986. (Pubitemid 16119332)
    • (1986) Analytical Chemistry , vol.58 , Issue.6 , pp. 1024-1028
    • Wang, J.1    Bonakdar, M.2    Morgan, C.3
  • 101
    • 84963253719 scopus 로고
    • Electrochemical determination of tricyclic antidepressants
    • E. S. Smotkin, G. B. Martin, and G. A. Rechnitz, "Electrochemical determination of tricyclic antidepressants", Anal. Lett., vol. 24, pp. 798-808, 1991.
    • (1991) Anal. Lett. , vol.24 , pp. 798-808
    • Smotkin, E.S.1    Martin, G.B.2    Rechnitz, G.A.3
  • 102
    • 77956145532 scopus 로고    scopus 로고
    • Combined hollow fiber-based liquid-liquid-liquid microextraction and in-situ differential pulse voltammetry to improve selectivity, sensitivity, and interference elimination in electrochemical analysis
    • M. Saraji, B. Farajmand, A. A. Ensafi, A. R. Allafchian, and Z. Mirahmdi-Zare, "Combined hollow fiber-based liquid-liquid-liquid microextraction and in-situ differential pulse voltammetry to improve selectivity, sensitivity, and interference elimination in electrochemical analysis", Talanta, vol. 82, pp. 1588-1593, 2010.
    • (2010) Talanta , vol.82 , pp. 1588-1593
    • Saraji, M.1    Farajmand, B.2    Ensafi, A.A.3    Allafchian, A.R.4    Mirahmdi-Zare, Z.5
  • 103
    • 0031811595 scopus 로고    scopus 로고
    • Quantitative determination of tricyclic antidepressants and their metabolites in plasma by solid-phase extraction (Bond-Elut TCA) and separation by capillary gas chromatography with nitrogen-phosphorous detection
    • DOI 10.1097/00007691-199806000-00017
    • D. Torre, R. Ortuno, J. Pascual, J. A. González, and S. B. Jordi, "Quantitative determination of tricyclic antidepressants and their metabolites in plasma by solid-phase extraction (bond-elut tca) and separation by capillary gas chromatography with nitrogen-phosphorous detection", J. Therap. Drug Monitoring, vol. 20, pp. 340-346, 1998. (Pubitemid 28248857)
    • (1998) Therapeutic Drug Monitoring , vol.20 , Issue.3 , pp. 340-346
    • De La Torre, R.1    Ortuno, J.2    Pascual, J.A.3    Gonzalez, S.4    Ballesta, J.5
  • 104
    • 33748329479 scopus 로고    scopus 로고
    • Ion-selective electrode for the determination of some multidrug resistance reversers
    • DOI 10.1016/j.snb.2005.12.021, PII S0925400505009846
    • J. A. Ortuno, J. Hernandez, and C. Sanchez-Pedreno, "Ion-selective electrode for the determination of some multidrug resistance reversers", Sens. Actuators B, vol. 119, pp. 282-287, 2006. (Pubitemid 44332067)
    • (2006) Sensors and Actuators, B: Chemical , vol.119 , Issue.1 , pp. 282-287
    • Ortuno, J.A.1    Hernandez, J.2    Sanchez-Pedreno, C.3
  • 105
    • 70549109054 scopus 로고    scopus 로고
    • Drug selective poly (vinyl chloride)-based sensor of desipramine hydrochloride
    • V. K. Gupta, M. K. Pal, and A. K. Singh, "Drug selective poly (vinyl chloride)-based sensor of desipramine hydrochloride", Electrochimica Acta, vol. 55, pp. 1061-1066, 2010.
    • (2010) Electrochimica Acta , vol.55 , pp. 1061-1066
    • Gupta, V.K.1    Pal, M.K.2    Singh, A.K.3
  • 106
    • 44749086292 scopus 로고    scopus 로고
    • Novel and selective potentiometric membrane sensor for amiloride determination in pharmaceutical compounds and urine
    • A. A. Ensafi and A. R. Allafchian, "Novel and selective potentiometric membrane sensor for amiloride determination in pharmaceutical compounds and urine", J. Pharm. Biomed. Anal., vol. 47, pp. 802-806, 2008.
    • (2008) J. Pharm. Biomed. Anal. , vol.47 , pp. 802-806
    • Ensafi, A.A.1    Allafchian, A.R.2
  • 107
    • 85022266459 scopus 로고
    • Plastic electrodes specific for organic ions
    • T. Higuchi, C. R. Illian, and J. L. Tossounian, "Plastic electrodes specific for organic ions", Anal. Chem., vol. 42, pp. 1674-1676, 1970.
    • (1970) Anal. Chem. , vol.42 , pp. 1674-1676
    • Higuchi, T.1    Illian, C.R.2    Tossounian, J.L.3
  • 108
    • 0034105466 scopus 로고    scopus 로고
    • Relationship between the hydrophobicity of cations and the cationic response of a plasticized poly (vinyl chloride) membrane electrode with no added ionexchanger
    • T. Masadome, T. Imato, S. I. Wakida, K. Higashi, and Y. Asano, "Relationship between the hydrophobicity of cations and the cationic response of a plasticized poly (vinyl chloride) membrane electrode with no added ionexchanger", Anal. Sci., vol. 16, pp. 383-389, 2000.
    • (2000) Anal. Sci. , vol.16 , pp. 383-389
    • Masadome, T.1    Imato, T.2    Wakida, S.I.3    Higashi, K.4    Asano, Y.5
  • 109
    • 60849087359 scopus 로고    scopus 로고
    • Rapid determination of pentazocine in human plasma and urine by a potentiometric method
    • A. R. Allafchian, A. A. Ensafi, and M. Saraji, "Rapid determination of pentazocine in human plasma and urine by a potentiometric method", Anal. Lett., vol. 42, pp. 571-583, 2009.
    • (2009) Anal. Lett. , vol.42 , pp. 571-583
    • Allafchian, A.R.1    Ensafi, A.A.2    Saraji, M.3
  • 110
    • 0022347746 scopus 로고
    • Construction of ion-selective electrodes for chlorpromazine, amitriptyline, propantheline and meperidine: Analytical study and application to pharmaceutical analysis
    • DOI 10.1039/an9851001091
    • A. Mitsana-Papazoglou, T. K. Christopoulos, E. P. Diamandis, and T. P. Hadjiioannou, "Construction of ion-selective electrodes for chlorpromazine, amitriptyline, propantheline and meperidine: Analytical study and application to pharmaceutical analysis", Analyst, vol. 110, pp. 1091-1094, 1985. (Pubitemid 16243109)
    • (1985) Analyst , vol.110 , Issue.9 , pp. 1091-1094
    • Mitsana-Papazoglou, A.1    Christopoulos, T.K.2    Diamandis, E.P.3    Hadjiioannou, T.P.4
  • 111
    • 0010480659 scopus 로고
    • New ampicillin selective plastic membrane and coated metal electrodes based on ampicillinium phosphotungstate ion pair
    • M. S. Rizk, Y. M. Issa, A. F. Shoukry, and M. M. Abdel-Aal, "New ampicillin selective plastic membrane and coated metal electrodes based on ampicillinium phosphotungstate ion pair", Anal. Lett., vol. 27, pp. 1055-1065, 1994.
    • (1994) Anal. Lett. , vol.27 , pp. 1055-1065
    • Rizk, M.S.1    Issa, Y.M.2    Shoukry, A.F.3    Abdel-Aal, M.M.4
  • 112
    • 0000028044 scopus 로고    scopus 로고
    • Diphenhydramine-selective plastic membrane sensor and its pharmaceutical applications
    • A. Erdem, M. Ozsoz, L. Kirilmaz, E. Kilinc, and T. Dalbasti, "Diphenhydramine-selective plastic membrane sensor and its pharmaceutical applications", Electroanalysis, vol. 9, pp. 932-935, 2005.
    • (2005) Electroanalysis , vol.9 , pp. 932-935
    • Erdem, A.1    Ozsoz, M.2    Kirilmaz, L.3    Kilinc, E.4    Dalbasti, T.5
  • 113
    • 0024428589 scopus 로고
    • The use of ion-selective electrodes in the determination of drug substances
    • DOI 10.1016/0731-7085(89)80001-9
    • K. Vytras, "The use of ion-selective electrodes in the determination of drug substances", J. Pharm. Biomed. Anal., vol. 7, pp. 789-812, 1989. (Pubitemid 19249573)
    • (1989) Journal of Pharmaceutical and Biomedical Analysis , vol.7 , Issue.7 , pp. 789-812
    • Vytras, K.1
  • 114
    • 0021850821 scopus 로고
    • Potentiometric titrations based on ion-pair formation
    • K. Vytras, "Potentiometric titrations based on ion-pair formation", Ion-Sel. Electrode Rev., vol. 7, pp. 77-164, 1985. (Pubitemid 15527320)
    • (1985) Ion-selective electrode reviews , vol.7 , Issue.1 , pp. 77-164
    • Vytras, K.1
  • 115
    • 0032369382 scopus 로고    scopus 로고
    • Validation criteria for developing ionselective membrane electrodes for analysis ofpharmaceuticals
    • R. Stefan and H. Y. Aboul-Enein, "Validation criteria for developing ionselective membrane electrodes for analysis ofpharmaceuticals", Accred. Qual. Assur., vol. 3, pp. 194-196, 1998.
    • (1998) Accred. Qual. Assur. , vol.3 , pp. 194-196
    • Stefan, R.1    Aboul-Enein, H.Y.2
  • 116
    • 46549096850 scopus 로고
    • Lipophilic salts as membrane additives and their influence on the properties of macro-and micro-electrodes based on neutral carriers
    • D. Ammann, E. Pretsch, W. Simon, E. Lindner, A. Bezegh, and E. Pungor, "Lipophilic salts as membrane additives and their influence on the properties of macro-and micro-electrodes based on neutral carriers", Anal. Chim. Acta, vol. 171, pp. 119-129, 1985.
    • (1985) Anal. Chim. Acta , vol.171 , pp. 119-129
    • Ammann, D.1    Pretsch, E.2    Simon, W.3    Lindner, E.4    Bezegh, A.5    Pungor, E.6
  • 117
    • 0019008094 scopus 로고
    • Life time of neutral carrier based ion selective liquid-membrane electrodes
    • U. Oesch and W. Simon, "Life time of neutral carrier based ion selective liquid-membrane electrodes", Anal. Chem., vol. 52, pp. 962-700, 1980.
    • (1980) Anal. Chem. , vol.52 , pp. 962-700
    • Oesch, U.1    Simon, W.2
  • 118
    • 0031592861 scopus 로고    scopus 로고
    • Partitioning of local anesthetic dibucaine into bilayer membranes of dimyristoylphosphatidylcholine
    • DOI 10.1016/S0927-7765(97)00043-X, PII S092777659700043X
    • S. Kaneshina, H. Satake, T. Yamamoto, Y. Kume, and H. Matsukia, "Partitioning of local anesthetic dibucaine into bilayer membranes of dimyristoylphosphatidylcholine", Colloids and Surfaces B: Biointerfaces, vol. 10, pp. 51-57, 1997. (Pubitemid 28075450)
    • (1997) Colloids and Surfaces B: Biointerfaces , vol.10 , Issue.1 , pp. 51-57
    • Kaneshina, S.1    Satake, H.2    Yamamoto, T.3    Kume, Y.4    Matsuki, H.5
  • 119
    • 0002670068 scopus 로고
    • Serum albumin structure and characterization of its ligand binding sites
    • P. C. Jost and O. H. Griffith, Eds. New York: John Wiley
    • J. R. Brown and P. Shockley, Serum Albumin Structure and Characterization of its Ligand Binding Sites in "Lipid-Protein Interactions", P. C. Jost and O. H. Griffith, Eds. New York: John Wiley, 1982, pp. 25-68.
    • (1982) Lipid-protein Interactions , pp. 25-68
    • Brown, J.R.1    Shockley, P.2
  • 120
    • 0037201660 scopus 로고    scopus 로고
    • Drug-selective electrode for ketamine determination in pharmaceutical preparations and electrochemical study of drug with BSA
    • DOI 10.1016/S0731-7085(02)00350-3, PII S0731708502003503
    • N. Alizadeh and R. Mehdipour, "Drug-selective electrode for ketamine determination in pharmaceutical preparations and electrochemical study of drug with BSA", J. Pharm. Biomed. Anal., vol. 30, pp. 725-731, 2002. (Pubitemid 35279698)
    • (2002) Journal of Pharmaceutical and Biomedical Analysis , vol.30 , Issue.3 , pp. 725-731
    • Alizadeh, N.1    Mehdipour, R.2
  • 121
    • 0002647656 scopus 로고    scopus 로고
    • Electrochemical study of the micellization of hexadecylpyridium bromide in the presence of some crown ethers
    • M. Shamsipur, N. Alizadeh, H. Gharibi, and M. F. Mousavi, "Electrochemical study of the micellization of hexadecylpyridium bromide in the presence of some crown ethers", J. Chin. Chem. Soc., vol. 44, pp. 9-15, 1997. (Pubitemid 127441996)
    • (1997) Journal of the Chinese Chemical Society , vol.44 , Issue.1 , pp. 9-15
    • Shamsipur, M.1    Alizadeh, N.2    Gharibi, H.3    Mousavi, M.F.4
  • 122
    • 0023746489 scopus 로고
    • Decrease in stability of human albumin with increase in protein concentration
    • P. D. Ross and A. Shrake, "Decrease in stability of human albumin with increase in protein concentration", J. Biol. Chem., vol. 263, pp. 11196-11202, 1988.
    • (1988) J. Biol. Chem. , vol.263 , pp. 11196-11202
    • Ross, P.D.1    Shrake, A.2
  • 123
    • 0001285423 scopus 로고    scopus 로고
    • Binding of n-alkyl sulphates to lysozyme in aqueous solution
    • M. N. Jones and P. Manley, "Binding of n-alkyl sulphates to lysozyme in aqueous solution", J. Chem. Soc., vol. 75, pp. 1736-1744, 1997.
    • (1997) J. Chem. Soc. , vol.75 , pp. 1736-1744
    • Jones, M.N.1    Manley, P.2
  • 124
    • 80052065835 scopus 로고    scopus 로고
    • Online. Available:, Oct. 2
    • [Online]. Available: http://en. wikipedia.org/wiki/Hill-equation Oct. 2, 2010.
    • (2010)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.