메뉴 건너뛰기




Volumn 10, Issue , 2011, Pages

The baseline pressure of intracranial pressure (ICP) sensors can be altered by electrostatic discharges

Author keywords

[No Author keywords available]

Indexed keywords

BRAIN INJURY; CLINICAL SETTINGS; COMPUTERIZED SYSTEMS; DISCHARGE MAGNITUDE; EXPERIMENTAL SETUP; INTRACRANIAL PRESSURE; LONG TERM MONITORING; NACL SOLUTION; PATIENT MANAGEMENT; PEAK PULSE; PHYSIOLOGICAL ORIGIN; PRESSURE CHANGE; PRESSURE READING; PRESSURE SIGNAL; ZERO POINT;

EID: 80052038256     PISSN: 1475925X     EISSN: 1475925X     Source Type: Journal    
DOI: 10.1186/1475-925X-10-75     Document Type: Article
Times cited : (23)

References (42)
  • 1
    • 0025942181 scopus 로고
    • Impact of ICP instability and hypotension on outcome in patients with severe head trauma
    • Marmarou A, Anderson RL, Ward JD, et al. Impact of ICP instability and hypotension on outcome in patients with severe head trauma. J Neurosurg 1991, 75:S59-S66.
    • (1991) J Neurosurg , vol.75
    • Marmarou, A.1    Anderson, R.L.2    Ward, J.D.3
  • 2
    • 0034626090 scopus 로고    scopus 로고
    • Traumatic brain injury
    • Ghajar J. Traumatic brain injury. The Lancet 2000, 356:923-929.
    • (2000) The Lancet , vol.356 , pp. 923-929
    • Ghajar, J.1
  • 3
    • 2442656667 scopus 로고    scopus 로고
    • Monitoring and interpretation of intracranial pressure
    • 10.1136/jnnp.2003.033126, 1739058, 15145991
    • Czosnyka M, Pickard JD. Monitoring and interpretation of intracranial pressure. J Neurol Neurosurg Psychiatry 2004, 75:813-821. 10.1136/jnnp.2003.033126, 1739058, 15145991.
    • (2004) J Neurol Neurosurg Psychiatry , vol.75 , pp. 813-821
    • Czosnyka, M.1    Pickard, J.D.2
  • 4
    • 77952094582 scopus 로고    scopus 로고
    • Intracranial pressure monitoring for traumatic brain injury in the modern era
    • 10.1007/s00381-009-1034-0, 21879411
    • Padayachy LC, Figaji AA, Bullock MR. Intracranial pressure monitoring for traumatic brain injury in the modern era. Child's Nerv Syst 2010, 26:441-452. 10.1007/s00381-009-1034-0, 21879411.
    • (2010) Child's Nerv Syst , vol.26 , pp. 441-452
    • Padayachy, L.C.1    Figaji, A.A.2    Bullock, M.R.3
  • 6
    • 0012053959 scopus 로고
    • Continuous recording and control of ventricular fluid pressure in neurosurgical practice
    • Lundberg N. Continuous recording and control of ventricular fluid pressure in neurosurgical practice. Acta Psychiatr Neurol Scand 1960, 36:1-193.
    • (1960) Acta Psychiatr Neurol Scand , vol.36 , pp. 1-193
    • Lundberg, N.1
  • 7
    • 0022804883 scopus 로고
    • Intracranial pressure: A review of clinical problems, measurement techniques and monitoring methods
    • Allen R. Intracranial pressure: A review of clinical problems, measurement techniques and monitoring methods. J Med Engin Tech 1986, 10:299-320.
    • (1986) J Med Engin Tech , vol.10 , pp. 299-320
    • Allen, R.1
  • 8
    • 0038353651 scopus 로고    scopus 로고
    • Advances in ICP monitoring techniques
    • 10.1179/016164103101201661, 12870259
    • Zhong J, Dujovny M, Park HK, et al. Advances in ICP monitoring techniques. Neurol Res 2003, 25:339-350. 10.1179/016164103101201661, 12870259.
    • (2003) Neurol Res , vol.25 , pp. 339-350
    • Zhong, J.1    Dujovny, M.2    Park, H.K.3
  • 9
    • 0026451192 scopus 로고
    • Monitoring of brain tissue pressure with a fiberoptic device
    • 10.1227/00006123-199211000-00014, 1436417
    • Gambardella G, d'Avella D, Tomasello F. Monitoring of brain tissue pressure with a fiberoptic device. Neurosurgery 1992, 31:918-922. 10.1227/00006123-199211000-00014, 1436417.
    • (1992) Neurosurgery , vol.31 , pp. 918-922
    • Gambardella, G.1    d'Avella, D.2    Tomasello, F.3
  • 10
    • 0028998150 scopus 로고
    • The evaluation of the wave-form analysis capability of a new strain-gauge intracranial pressure microsensor
    • 10.1227/00006123-199506000-00012, 7643994
    • Piper IR, Miller JD. The evaluation of the wave-form analysis capability of a new strain-gauge intracranial pressure microsensor. Neurosurgery 1995, 36:1142-1145. 10.1227/00006123-199506000-00012, 7643994.
    • (1995) Neurosurgery , vol.36 , pp. 1142-1145
    • Piper, I.R.1    Miller, J.D.2
  • 11
    • 0034432982 scopus 로고    scopus 로고
    • Experimental evaluation of the Spiegelberg intracranial pressure and intracranial compliance monitor
    • 10.3171/jns.2000.93.6.1072, 11117854
    • Yau YH, Piper I, Clutton RE Whittle IR. Experimental evaluation of the Spiegelberg intracranial pressure and intracranial compliance monitor. J Neurosurg 2000, 93:1072-1077. 10.3171/jns.2000.93.6.1072, 11117854.
    • (2000) J Neurosurg , vol.93 , pp. 1072-1077
    • Yau, Y.H.1    Piper, I.2    Clutton RE Whittle, I.R.3
  • 12
    • 0346665735 scopus 로고    scopus 로고
    • Clinical evaluation of a new intracranial pressure monitoring device
    • Stendel R, Heidenreich J, Schilling A, et al. Clinical evaluation of a new intracranial pressure monitoring device. Acta Neurochir 2003, 145:185-193.
    • (2003) Acta Neurochir , vol.145 , pp. 185-193
    • Stendel, R.1    Heidenreich, J.2    Schilling, A.3
  • 13
    • 49049121311 scopus 로고    scopus 로고
    • Laboratory testing of the Pressio intracranial pressure monitor
    • 10.1227/01.neu.0000325878.67752.eb, 18580814
    • Allin D, Czosnyka M, Czosnyka Z. Laboratory testing of the Pressio intracranial pressure monitor. Neurosurgery 2008, 62:1158-1161. 10.1227/01.neu.0000325878.67752.eb, 18580814.
    • (2008) Neurosurgery , vol.62 , pp. 1158-1161
    • Allin, D.1    Czosnyka, M.2    Czosnyka, Z.3
  • 14
    • 0030045391 scopus 로고    scopus 로고
    • Laboratory testing of three intracranial pressure microtransducers: Technical report
    • 10.1097/00006123-199601000-00053, 8747977
    • Czosnyka M, Czosnyka Z, Pickard JD. Laboratory testing of three intracranial pressure microtransducers: Technical report. Neurosurgery 1996, 38:219-224. 10.1097/00006123-199601000-00053, 8747977.
    • (1996) Neurosurgery , vol.38 , pp. 219-224
    • Czosnyka, M.1    Czosnyka, Z.2    Pickard, J.D.3
  • 15
    • 0032877840 scopus 로고    scopus 로고
    • ICP measurement control: Laboratory test of 7 types of intracranial pressure transducers
    • Morgalla MH, Mettenleiter H, Bitzer M, et al. ICP measurement control: Laboratory test of 7 types of intracranial pressure transducers. J Medical Engineer Techn 1999, 23:144-151.
    • (1999) J Medical Engineer Techn , vol.23 , pp. 144-151
    • Morgalla, M.H.1    Mettenleiter, H.2    Bitzer, M.3
  • 16
    • 0034864106 scopus 로고    scopus 로고
    • Methods of experimental and clinical assessment of the relative measurement accuracy of an intracranial pressure transducer. Technical note
    • 10.3171/jns.2001.95.3.0529, 11565881
    • Morgalla MH, Krasznai L, Dietz K, et al. Methods of experimental and clinical assessment of the relative measurement accuracy of an intracranial pressure transducer. Technical note. J Neurosurg 2001, 95:529-532. 10.3171/jns.2001.95.3.0529, 11565881.
    • (2001) J Neurosurg , vol.95 , pp. 529-532
    • Morgalla, M.H.1    Krasznai, L.2    Dietz, K.3
  • 17
    • 0036160033 scopus 로고    scopus 로고
    • The problem of long-term ICP drift assessment: Improvement by use of the ICP drift index
    • Morgalla MH, Dietz K, Deininger M, et al. The problem of long-term ICP drift assessment: Improvement by use of the ICP drift index. Acta Neurochir 2002, 144:57-61.
    • (2002) Acta Neurochir , vol.144 , pp. 57-61
    • Morgalla, M.H.1    Dietz, K.2    Deininger, M.3
  • 18
    • 0034773630 scopus 로고    scopus 로고
    • The Camino intracranial pressure sensor: Is it optimal technology? An internal audit with a review of current intracranial pressure monitoring technologies
    • Piper I, Barnes A, Smith D, et al. The Camino intracranial pressure sensor: Is it optimal technology? An internal audit with a review of current intracranial pressure monitoring technologies. Neurosurgery 2001, 49:1158-1165.
    • (2001) Neurosurgery , vol.49 , pp. 1158-1165
    • Piper, I.1    Barnes, A.2    Smith, D.3
  • 19
    • 8744295791 scopus 로고    scopus 로고
    • Bench test assessment of the new Raumedic Neurovent-P ICP sensor: a technical report by the Brain-IT group
    • Citerio G, Piper I, Cormio M, et al. Bench test assessment of the new Raumedic Neurovent-P ICP sensor: a technical report by the Brain-IT group. Acta Neurochir (Wien) 2004, 146:1221-1226.
    • (2004) Acta Neurochir (Wien) , vol.146 , pp. 1221-1226
    • Citerio, G.1    Piper, I.2    Cormio, M.3
  • 20
    • 0028811017 scopus 로고
    • Results and complications of intracranial pressure monitroing in 303 children
    • 10.1159/000120938, 8555097
    • Pople IK, Muhlbauer MS, Sanford RA, et al. Results and complications of intracranial pressure monitroing in 303 children. Pediatr Neurosurg 1995, 23:64-67. 10.1159/000120938, 8555097.
    • (1995) Pediatr Neurosurg , vol.23 , pp. 64-67
    • Pople, I.K.1    Muhlbauer, M.S.2    Sanford, R.A.3
  • 21
    • 0029851897 scopus 로고    scopus 로고
    • A clinical study of parenchymal and subdural miniature strain-gauge transducers for monitoring intracranial pressure
    • Gray WP, Palmer JD, Gill J, et al. A clinical study of parenchymal and subdural miniature strain-gauge transducers for monitoring intracranial pressure. Neurosurgery 1996, 39:927-932.
    • (1996) Neurosurgery , vol.39 , pp. 927-932
    • Gray, W.P.1    Palmer, J.D.2    Gill, J.3
  • 22
    • 0032253457 scopus 로고    scopus 로고
    • Clinical evaluation of the Codman microsensor inracranial pressure monitoring system
    • Fernandes HM, Bingham K, Chambers IR, Mendelow AD. Clinical evaluation of the Codman microsensor inracranial pressure monitoring system. Acta Neurochir 1998, 71(Suppl):44-46.
    • (1998) Acta Neurochir , vol.71 , Issue.SUPPL. , pp. 44-46
    • Fernandes, H.M.1    Bingham, K.2    Chambers, I.R.3    Mendelow, A.D.4
  • 23
    • 0032254165 scopus 로고    scopus 로고
    • Cerebral monitoring devices: Analysis of complications
    • Guyot LL, Dowling C, Diaz FG, et al. Cerebral monitoring devices: Analysis of complications. Acta Neurochir 1998, 71(Suppl):47-49.
    • (1998) Acta Neurochir , vol.71 , Issue.SUPPL. , pp. 47-49
    • Guyot, L.L.1    Dowling, C.2    Diaz, F.G.3
  • 24
    • 0032254166 scopus 로고    scopus 로고
    • Complications and safety associated with ICP monitoring: A study of 542 patients
    • Rossi S, Buzzi F, Paparella A, et al. Complications and safety associated with ICP monitoring: A study of 542 patients. Acta Neurochir 1998, 71(Suppl):91-93.
    • (1998) Acta Neurochir , vol.71 , Issue.SUPPL. , pp. 91-93
    • Rossi, S.1    Buzzi, F.2    Paparella, A.3
  • 25
    • 0031804799 scopus 로고    scopus 로고
    • A clinical evaluation of the Codman Microsensor for intracranial pressure monitoring
    • Signorini DF, Shad A, Piper IR, et al. A clinical evaluation of the Codman Microsensor for intracranial pressure monitoring. Br J Neurosurg 1998, 1:223-227.
    • (1998) Br J Neurosurg , vol.1 , pp. 223-227
    • Signorini, D.F.1    Shad, A.2    Piper, I.R.3
  • 26
    • 0037941449 scopus 로고    scopus 로고
    • Clinical evaluation of intraparenchymal Spiegelberg pressure sensor
    • 10.1227/01.NEU.0000065136.70455.6F, 12762891
    • Lang J-M, Beck J, Zimmermann M. Clinical evaluation of intraparenchymal Spiegelberg pressure sensor. Neurosurgery 2003, 52:1455-1459. 10.1227/01.NEU.0000065136.70455.6F, 12762891.
    • (2003) Neurosurgery , vol.52 , pp. 1455-1459
    • Lang, J.-M.1    Beck, J.2    Zimmermann, M.3
  • 27
    • 16844384736 scopus 로고    scopus 로고
    • Clinical experience with the intraparenchymal intracranial pressure monitoring Codman Microsensor system
    • 10.1227/01.NEU.0000156609.95596.24, 15792507
    • Koskinen L-O, Olivecrona M. Clinical experience with the intraparenchymal intracranial pressure monitoring Codman Microsensor system. Neurosurgery 2005, 56:693-698. 10.1227/01.NEU.0000156609.95596.24, 15792507.
    • (2005) Neurosurgery , vol.56 , pp. 693-698
    • Koskinen, L.-O.1    Olivecrona, M.2
  • 28
    • 33645099553 scopus 로고    scopus 로고
    • The Camino intracranial pressure device in clinical practice. Assessment in a 1000 cases
    • Gelabert-Gonzàlez M, Ginesta-Galan V, Sernamito-Garcia R, et al. The Camino intracranial pressure device in clinical practice. Assessment in a 1000 cases. Acta Neurochir 2006, 148:435-441.
    • (2006) Acta Neurochir , vol.148 , pp. 435-441
    • Gelabert-Gonzàlez, M.1    Ginesta-Galan, V.2    Sernamito-Garcia, R.3
  • 29
    • 43249131291 scopus 로고    scopus 로고
    • Intracranial pressure monitoring with the Neurodur-P epidural sensor: A prospective study in patients with adult hydrocephalus or idiopathic intracranial hypertension
    • 10.3171/JNS/2008/108/5/0934, 18447710
    • Poca M, Martinez-Ricarte F, Sahuquillo J, et al. Intracranial pressure monitoring with the Neurodur-P epidural sensor: A prospective study in patients with adult hydrocephalus or idiopathic intracranial hypertension. J Neurosurg 2008, 108:934-942. 10.3171/JNS/2008/108/5/0934, 18447710.
    • (2008) J Neurosurg , vol.108 , pp. 934-942
    • Poca, M.1    Martinez-Ricarte, F.2    Sahuquillo, J.3
  • 30
    • 78650157682 scopus 로고    scopus 로고
    • Simultaneous measurements of intracranial pressure parameters in the epidural space and in brain parenchyma in patients with hydrocephalus
    • 10.3171/2010.7.JNS10483, 20799859
    • Eide PK, Sorteberg W. Simultaneous measurements of intracranial pressure parameters in the epidural space and in brain parenchyma in patients with hydrocephalus. J Neurosurg 2010, 113:1317-1325. 10.3171/2010.7.JNS10483, 20799859.
    • (2010) J Neurosurg , vol.113 , pp. 1317-1325
    • Eide, P.K.1    Sorteberg, W.2
  • 31
    • 33646349719 scopus 로고    scopus 로고
    • Comparison of simultaneous continuous intracranial pressure (ICP) signals from a Codman and a Camino ICP sensor
    • Eide PK. Comparison of simultaneous continuous intracranial pressure (ICP) signals from a Codman and a Camino ICP sensor. Med Eng Physics 2006, 28:542-549.
    • (2006) Med Eng Physics , vol.28 , pp. 542-549
    • Eide, P.K.1
  • 32
    • 38149130387 scopus 로고    scopus 로고
    • Comparison of simultaneous continuous intracranial pressure (ICP) signals from ICP sensors placed within the brain parenchyma and the epidural space
    • Eide PK. Comparison of simultaneous continuous intracranial pressure (ICP) signals from ICP sensors placed within the brain parenchyma and the epidural space. Med Eng Physics 2008, 30:34-40.
    • (2008) Med Eng Physics , vol.30 , pp. 34-40
    • Eide, P.K.1
  • 33
    • 77749264552 scopus 로고    scopus 로고
    • A dynamic nonlinear relationship between the static and pulsatile components of intracranial pressure in patients with subarachnoid hemorrhage
    • 10.3171/2009.7.JNS081593, 19731984
    • Eide PK, Rapoport BI, Gormley WB, et al. A dynamic nonlinear relationship between the static and pulsatile components of intracranial pressure in patients with subarachnoid hemorrhage. J Neurosurg 2010, 112:616-625. 10.3171/2009.7.JNS081593, 19731984.
    • (2010) J Neurosurg , vol.112 , pp. 616-625
    • Eide, P.K.1    Rapoport, B.I.2    Gormley, W.B.3
  • 34
    • 0014060913 scopus 로고
    • Hazards of electrical apparatus
    • 10.1097/00000542-196703000-00023, 5338059
    • Bruner JM. Hazards of electrical apparatus. Anesthesiology 1967, 28:396-425. 10.1097/00000542-196703000-00023, 5338059.
    • (1967) Anesthesiology , vol.28 , pp. 396-425
    • Bruner, J.M.1
  • 35
    • 0015345051 scopus 로고
    • Electrical incidents in a largehospital: a 42 month register
    • Bruner JM, Aronow S, Cavicchi RV. Electrical incidents in a largehospital: a 42 month register. J Assoc Adv Med Instrum 1972, 6:222-230.
    • (1972) J Assoc Adv Med Instrum , vol.6 , pp. 222-230
    • Bruner, J.M.1    Aronow, S.2    Cavicchi, R.V.3
  • 36
    • 0015402083 scopus 로고
    • Characteristics of electrical hazards
    • Leonard PF. Characteristics of electrical hazards. Anesth Analg 1972, 51:797-809.
    • (1972) Anesth Analg , vol.51 , pp. 797-809
    • Leonard, P.F.1
  • 37
    • 0016069783 scopus 로고
    • Eletrical safety in the hospital - 1974
    • Weibell FJ. Eletrical safety in the hospital - 1974. Ann Biomed Engineer 1974, 2:126-148.
    • (1974) Ann Biomed Engineer , vol.2 , pp. 126-148
    • Weibell, F.J.1
  • 38
    • 33847404853 scopus 로고    scopus 로고
    • Safety While Swimming in a Sea of Energy
    • 10.4065/82.3.276, 17352361
    • Abenstein JP. Safety While Swimming in a Sea of Energy. Mayo Clinic Proceedings 2007, 82:276-278. 10.4065/82.3.276, 17352361.
    • (2007) Mayo Clinic Proceedings , vol.82 , pp. 276-278
    • Abenstein, J.P.1
  • 39
    • 0030383564 scopus 로고    scopus 로고
    • The effect of static charge generated on hospital bedding
    • Holdstock P, Wilson N. The effect of static charge generated on hospital bedding. EOS/ESD Symposium 1996, 356-364.
    • (1996) EOS/ESD Symposium , pp. 356-364
    • Holdstock, P.1    Wilson, N.2
  • 40
    • 18244398664 scopus 로고    scopus 로고
    • Standardisation of electrostatic test methods and electrostatic discharge prevention measures for the world market
    • Smallwood J. Standardisation of electrostatic test methods and electrostatic discharge prevention measures for the world market. J Electrostatics 2005, 63:501-508.
    • (2005) J Electrostatics , vol.63 , pp. 501-508
    • Smallwood, J.1
  • 41
    • 0034041023 scopus 로고    scopus 로고
    • Measurements of incendivity of electrostatic discharges from textiles used in personal protective clothing
    • Kathirgamanathan P, Toohey MJ, Haase J, et al. Measurements of incendivity of electrostatic discharges from textiles used in personal protective clothing. J Electrostatics 2000, 49:51-70.
    • (2000) J Electrostatics , vol.49 , pp. 51-70
    • Kathirgamanathan, P.1    Toohey, M.J.2    Haase, J.3
  • 42
    • 33646374393 scopus 로고    scopus 로고
    • A new method for processing of continuous intracranial pressure signals
    • Eide PK. A new method for processing of continuous intracranial pressure signals. Med Eng Physics 2006, 28:579-587.
    • (2006) Med Eng Physics , vol.28 , pp. 579-587
    • Eide, P.K.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.