메뉴 건너뛰기




Volumn 4, Issue 3, 2011, Pages 217-225

Analysis of thermal comfort in a residential room with insect proof screen: A case study by numerical simulation methods

Author keywords

CFD; Insect proof screen; PMV; Thermal comfort

Indexed keywords


EID: 80051961195     PISSN: 19963599     EISSN: 19968744     Source Type: Journal    
DOI: 10.1007/s12273-011-0032-9     Document Type: Article
Times cited : (9)

References (18)
  • 2
    • 0036075859 scopus 로고    scopus 로고
    • Numerical simulation of the air flow and temperature distribution in a tunnel green house equipped with insect-proof screen in the openings
    • Bartsanas T, Bourlard T, Kittas C (2002). Numerical simulation of the air flow and temperature distribution in a tunnel green house equipped with insect-proof screen in the openings. Computer and Electronics in Agriculture, 34: 207-221.
    • (2002) Computer and Electronics In Agriculture , vol.34 , pp. 207-221
    • Bartsanas, T.1    Bourlard, T.2    Kittas, C.3
  • 3
    • 0027607941 scopus 로고
    • Prediction of pressure drop for incompressible flow through screens
    • Brundrett E (1993). Prediction of pressure drop for incompressible flow through screens. Journal of Fluids Engineering, 115: 239-242.
    • (1993) Journal of Fluids Engineering , vol.115 , pp. 239-242
    • Brundrett, E.1
  • 4
    • 33144455535 scopus 로고    scopus 로고
    • Optimisation of green house insect screening with computational fluid dynamics
    • Fatnassi H, Boulard T, Poncet C, Chave M (2006). Optimisation of green house insect screening with computational fluid dynamics. Biosystems Engineering, 93: 301-12.
    • (2006) Biosystems Engineering , vol.93 , pp. 301-312
    • Fatnassi, H.1    Boulard, T.2    Poncet, C.3    Chave, M.4
  • 5
    • 0033875842 scopus 로고    scopus 로고
    • Effective depth of fresh air distribution in rooms with single-sided natural ventilation
    • Gan G (2000). Effective depth of fresh air distribution in rooms with single-sided natural ventilation. Energy and Buildings, 31: 65-73.
    • (2000) Energy and Buildings , vol.31 , pp. 65-73
    • Gan, G.1
  • 6
    • 0026897785 scopus 로고
    • Computational fluid dynamic for building air flow prediction-Current status and capabilities
    • Jones P, Whittle GE (1992). Computational fluid dynamic for building air flow prediction-Current status and capabilities. Building and Environment, 27: 321-338.
    • (1992) Building and Environment , vol.27 , pp. 321-338
    • Jones, P.1    Whittle, G.E.2
  • 10
    • 21444446039 scopus 로고    scopus 로고
    • Prediction and analysis model of temperature and its application to a natural ventilation multi-span plastic greenhouse equipped with insect-proof screen
    • Liu SZ, He Y, Zhang YB, Miao XW (2005). Prediction and analysis model of temperature and its application to a natural ventilation multi-span plastic greenhouse equipped with insect-proof screen. Journal of Zhejiang University Science B, 6: 523-529.
    • (2005) Journal of Zhejiang University Science B , vol.6 , pp. 523-529
    • Liu, S.Z.1    He, Y.2    Zhang, Y.B.3    Miao, X.W.4
  • 13
    • 19344367675 scopus 로고    scopus 로고
    • Wind caused air transport through green house screens: A physical modeling approach
    • Miguel AF (1999). Wind caused air transport through green house screens: A physical modeling approach. International AgroPhysics, 13: 191-195.
    • (1999) International AgroPhysics , vol.13 , pp. 191-195
    • Miguel, A.F.1
  • 16
    • 0036568496 scopus 로고    scopus 로고
    • Computation of the airflow in a pilot scale clean room using κ-ε turbulence models
    • Rouaud O, Havet M (2002). Computation of the airflow in a pilot scale clean room using κ-ε turbulence models. International Journal of Refrigeration, 25: 351-361.
    • (2002) International Journal of Refrigeration , vol.25 , pp. 351-361
    • Rouaud, O.1    Havet, M.2
  • 17
    • 80051968375 scopus 로고    scopus 로고
    • Analysis of thermal comfort in an office room by varying the dimensions of the windows on adjacent walls using CFD: A case study based on numerical simulation
    • Ravikumar P, Prakash D (2009). Analysis of thermal comfort in an office room by varying the dimensions of the windows on adjacent walls using CFD: A case study based on numerical simulation. Building Simulation, 2: 187-196.
    • (2009) Building Simulation , vol.2 , pp. 187-196
    • Ravikumar, P.1    Prakash, D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.