-
1
-
-
84860401746
-
-
National Heart, Lung, and Blood Institute, RFP/BAA NHLBIHV-04-01
-
National Heart, Lung, and Blood Institute. Paediatric circulatory support, 2002, RFP/BAA NHLBIHV-04-01.
-
(2002)
Paediatric Circulatory Support
-
-
-
2
-
-
84860414108
-
-
Departments of labor, health and human services, and education, and related agencies appropriation bill
-
US Senate Report 108-081. Departments of labor, health and human services, and education, and related agencies appropriation bill, 2004, pp 1122004.
-
(2004)
US Senate Report 108-081
, pp. 1122004
-
-
-
3
-
-
0016617573
-
Design of a hydraulic analog of the circulatory system for evaluating artificial hearts
-
Donovan, F. M., Jr. Design of a hydraulic analog of the circulatory system for evaluating artificial hearts. Biomater. Med. Devices Artif. Organs, 1975, 3(4), 439-449.
-
(1975)
Biomater. Med. Devices Artif. Organs
, vol.3
, Issue.4
, pp. 439-449
-
-
Donovan Jr., F.M.1
-
4
-
-
0019799237
-
Design and evaluation of the Pennsylvania State University mock circulatory system
-
Rosenberg, G., Winfred, M. P., Landis, D. L., and Pierce, W. S. Design and evaluation of the Pennsylvania State University mock circulatory system. ASAIO journal J., 1981, 4 (April/June), 41-49. (Pubitemid 12137812)
-
(1981)
ASAIO Journal
, vol.4
, Issue.2
, pp. 41-49
-
-
Rosenberg, G.1
Phillips, W.M.2
Landis, D.L.3
Pierce, W.S.4
-
5
-
-
0026557117
-
Compact mock loop of the systemic and pulmonary circulation for blood pump testing
-
Knierbein, B., Reul, H., Eilers, R., Lange, M., Kaufmann, R., and Rau, G. Compact mock loop of the systemic and pulmonary circulation for blood pump testing. Int. J. Artif. Organs, 1992, 15(1), 40-48.
-
(1992)
Int. J. Artif. Organs
, vol.15
, Issue.1
, pp. 40-48
-
-
Knierbein, B.1
Reul, H.2
Eilers, R.3
Lange, M.4
Kaufmann, R.5
Rau, G.6
-
6
-
-
0348230939
-
Characterization of an Adult Mock Circulation for Testing Cardiac Support Devices
-
DOI 10.1097/01.MAT.0000104818.70726.E6
-
Pantalos, G. M., Koenig, S. C., Gillars, K. J., Giridharan, G. A., and Ewert, D. L. Characterization of an adult mock circulation for testing cardiac support devices. ASAIO J., 2004, 50(1), 37-46. (Pubitemid 38063999)
-
(2004)
ASAIO Journal
, vol.50
, Issue.1
, pp. 37-46
-
-
Pantalos, G.M.1
Koenig, S.C.2
Gillars, K.J.3
Giridharan, G.A.4
Ewert, D.L.5
-
7
-
-
0034798216
-
Hydrodynamic characterisation of ventricular assist devices
-
Vandenberghe, S., Segers, P., Meyns, B., and Verdonck, P. Hydrodynamic characterisation of ventricular assist devices. Int. J. Artif. Organs, 2001, 24(7), 470-477. (Pubitemid 32904095)
-
(2001)
International Journal of Artificial Organs
, vol.24
, Issue.7
, pp. 470-477
-
-
Vandenberghe, S.1
Segers, P.2
Meyns, B.3
Verdonck, P.4
-
8
-
-
0029866610
-
In vitro testing of a left ventricular assist device Study of the effect of its control strategy on energetic relationships inside the left ventricle
-
Ferrari, G., Gorczynska, K., de Lazzari, C., Grodzicki, K., Mimmo, R., Ambrosi, D., and Tosti, G. In vitro testing of a left ventricular assist device. Study of the effect of its control strategy on energetic relationships inside the left ventricle. Technol. Health Care, 1996, 3(4), 231-239. (Pubitemid 26084942)
-
(1996)
Technology and Health Care
, vol.3
, Issue.4
, pp. 231-239
-
-
Ferrari, G.1
Gorczynska, K.2
De Lazzari, C.3
Grodzicki, K.4
Mimmo, R.5
Ambrosi, D.6
Tosti, G.7
-
9
-
-
0034744380
-
Elastance-based control of a mock circulatory system
-
DOI 10.1114/1.1355275
-
Baloa, L. A., Boston, J. R., and Antaki, J. F. Elastance-based control of a mock circulatory system. Ann. Biomed. Engng, 2001, 29(3), 244-251. (Pubitemid 32380953)
-
(2001)
Annals of Biomedical Engineering
, vol.29
, Issue.3
, pp. 244-251
-
-
Baloa, L.A.1
Boston, J.R.2
Antaki, J.F.3
-
10
-
-
23844507103
-
Development of a hybrid (numerical-hydraulic) circulatory model: Prototype testing and its response to IABP assistance
-
Ferrari, G., Kozarski, M., de Lazzari, C., Gorczynska, K., Tosti, G., and Darowski, M. Development of a hybrid (numerical-hydraulic) circulatory model: prototype testing and its response to IABP assistance. Int. J. Artif. Organs, 2005, 28(7), 750-759. (Pubitemid 41167276)
-
(2005)
International Journal of Artificial Organs
, vol.28
, Issue.7
, pp. 750-759
-
-
Ferrari, G.1
Kozarski, M.2
De Lazzari, C.3
Gorczynska, K.4
Tosti, G.5
Darowski, M.6
-
11
-
-
0026955440
-
Computer-controlled in vitro model of the human left heart
-
DOI 10.1007/BF02446800
-
Verdonck, P., Kleven, A., Verhoeven, R., Angelsen, B., and Vandenbogaerde, J. Computercontrolled in vitro model of the human left heart. Med. Biol. Engng Comput., 1992, 30(6), 656-659. (Pubitemid 23009093)
-
(1992)
Medical and Biological Engineering and Computing
, vol.30
, Issue.6
, pp. 656-659
-
-
Verdonck, P.1
Kleven, A.2
Verhoeven, R.3
Angelsen, B.4
Vandenbogaerde, J.5
-
12
-
-
33746831159
-
Hemodynamic guidelines for design and control of a turbodynamic pediatric ventricular assist device
-
DOI 10.1097/01.mat.0000227730.00085.36, PII 0000248020060700000019
-
Uber, B. E., Webber, S. A., Morell, V. O., and Antaki, J. F. Hemodynamic guidelines for design and control of a turbodynamic paediatric ventricular assist device. ASAIO J., 2006, 52(4), 471-478. (Pubitemid 44174637)
-
(2006)
ASAIO Journal
, vol.52
, Issue.4
, pp. 471-478
-
-
Uber, B.E.1
Webber, S.A.2
Morell, V.O.3
Antaki, J.F.4
-
13
-
-
62849083921
-
Corrected and improved model for educational simulation of neonatal cardiovascular pathophysiology
-
Zijlmans, M., Sa-Couto, C. D., van Meurs, W. L., Goodwin, J. A., and Andriessen, P. Corrected and improved model for educational simulation of neonatal cardiovascular pathophysiology. Simul. Healthc., 2009, 4(1), 49-53.
-
(2009)
Simul. Healthc.
, vol.4
, Issue.1
, pp. 49-53
-
-
Zijlmans, M.1
Sa-Couto, C.D.2
Van Meurs, W.L.3
Goodwin, J.A.4
Andriessen, P.5
-
14
-
-
0001740359
-
Die Grundform des arterielen Pulses erste Abhandlung: Mathematische Analyse
-
Frank, O. Die Grundform des arterielen Pulses erste Abhandlung: mathematische Analyse. Z. Biol., 1899, 37, 483-526.
-
(1899)
Z. Biol.
, vol.37
, pp. 483-526
-
-
Frank, O.1
-
15
-
-
70349342724
-
The Importance of dQ/dt on the flow field in a turbodynamic pump with pulsatile flow
-
Shu, F., Vandenberghe, S., and Antaki, J. The Importance of dQ/dt on the flow field in a turbodynamic pump With pulsatile flow. Artif. Organs, 2009, 33(9), 757-762.
-
(2009)
Artif. Organs
, vol.33
, Issue.9
, pp. 757-762
-
-
Shu, F.1
Vandenberghe, S.2
Antaki, J.3
-
16
-
-
70450272579
-
Pulsatile in vitro simulation of the paediatric univentricular circulation for evaluation of cardiopulmonary assist scenarios
-
Dur, O., Lara, M., Arnold, D., Vandenberghe, S., Keller, B.B., DeGroff, C., and Pekkan, K. Pulsatile in vitro simulation of the paediatric univentricular circulation for evaluation of cardiopulmonary assist scenarios. Artif Organs, 2009, 33(11), 967-976.
-
(2009)
Artif Organs
, vol.33
, Issue.11
, pp. 967-976
-
-
Dur, O.1
Lara, M.2
Arnold, D.3
Vandenberghe, S.4
Keller, B.B.5
Degroff, C.6
Pekkan, K.7
-
17
-
-
84860393550
-
Biocompatibility assessment of the first generation PediaFlow paediatric ventricular assist device
-
Published online: Jul. 9
-
Johnson, C., Vandenberghe, S., Daly, A., Woolley, J., Snyder, S., Verkaik, J., Ye, S., Borovetz, H., Antaki, J., Wearden, P., Kameneva, M., and Wagner, W. Biocompatibility Assessment of the First Generation PediaFlow Paediatric Ventricular Assist Device. Artif Organs,. Published online: Jul. 9, 2010.
-
(2010)
Artif Organs
-
-
Johnson, C.1
Vandenberghe, S.2
Daly, A.3
Woolley, J.4
Snyder, S.5
Verkaik, J.6
Ye, S.7
Borovetz, H.8
Antaki, J.9
Wearden, P.10
Kameneva, M.11
Wagner, W.12
-
18
-
-
0015147582
-
An artificial arterial system for pumping hearts
-
Westerhof, N., Elzinga, G., and Sipkema, P. An artificial arterial system for pumping hearts. J. Appl. Physiol., 1971, 31(5), 776-781.
-
(1971)
J. Appl. Physiol.
, vol.31
, Issue.5
, pp. 776-781
-
-
Westerhof, N.1
Elzinga, G.2
Sipkema, P.3
|