Dose-specific effects of transcutaneous electrical nerve stimulation (TENS) on experimental pain: A systematic review

Author keywords

amplitude; analgesia; electrical stimulation; experimentally induced pain; frequency; stimulation site

Indexed keywords

CAPSAICIN; PLACEBO;

EID: 80051786266     PISSN: 07498047     EISSN: 15365409     Source Type: Journal    
DOI: 10.1097/AJP.0b013e31821962b4     Document Type: Review
Times cited : (65)

References (123)
  • 1
    • 0003188083 scopus 로고    scopus 로고
    • Guide to physical therapist practice
    • American Physical Therapy Association, 2nd ed
    • American Physical Therapy Association. Guide to physical therapist practice, 2nd ed. Phys Ther. 2001;81:9-744.
    • (2001) Phys Ther , vol.81 , pp. 9-744
  • 2
    • 0037396731 scopus 로고    scopus 로고
    • Transcutaneous electrical nerve stimulation: Basic science mechanisms and clinical effectiveness
    • DOI 10.1054/jpai.2003.434
    • Sluka KA, Walsh D. Transcutaneous electrical nerve stimulation: basic science mechanisms and clinical effectiveness. J Pain. 2003;4:109-121. (Pubitemid 36523430)
    • (2003) Journal of Pain , vol.4 , Issue.3 , pp. 109-121
    • Sluka, K.A.1    Walsh, D.2
  • 3
  • 4
    • 80051794215 scopus 로고    scopus 로고
    • Reduction in inflammation-induced sensitization of dorsal horn neurons by transcutaneous electrical nerve stimulation (TENS)
    • Ma YT, Sluka KA. Reduction in inflammation-induced sensitization of dorsal horn neurons by transcutaneous electrical nerve stimulation (TENS). Clin J Pain. 2001;7:122-129.
    • (2001) Clin J Pain , vol.7 , pp. 122-129
    • Ma, Y.T.1    Sluka, K.A.2
  • 5
    • 0013851199 scopus 로고
    • Pain mechanisms: A new theory
    • Melzack R, Wall PD. Pain mechanisms: a new theory. Science. 1965;150:971-978.
    • (1965) Science , vol.150 , pp. 971-978
    • Melzack, R.1    Wall, P.D.2
  • 6
    • 0342979863 scopus 로고    scopus 로고
    • Induction of homosynaptic long-term depression at spinal synapses of sensory Aδ-fibers requires activation of metabotropic glutamate receptors
    • DOI 10.1016/S0306-4522(00)00080-4, PII S0306452200000804
    • Chen J, Sandkuhler J. Induction of homosynaptic long-term depression at spinal synapses of sensory A delta-fibers requires activation of metabotropic glutamate receptors. Neuroscience. 2000;98:141-148. (Pubitemid 30349152)
    • (2000) Neuroscience , vol.98 , Issue.1 , pp. 141-148
    • Chen, J.1    Sandkuhler, J.2
  • 7
    • 0002463094 scopus 로고    scopus 로고
    • Acupuncture-like transcutaneous electrical nerve stimulation (AL-TENS) in the management of pain
    • Johnson MI. Acupuncture-like transcutaneous electrical nerve stimulation (AL-TENS) in the management of pain. Phys Ther Rev. 1998;3:73-93.
    • (1998) Phys Ther Rev , vol.3 , pp. 73-93
    • Johnson, M.I.1
  • 8
    • 0000113946 scopus 로고
    • Transcutaneous and implanted electric stimulation of peripheral nerves
    • Bonica JJ, ed, 2nd ed. Philadelphia: Lea and Febiger
    • Sjolund B, Eriksson M, Loeser J. Transcutaneous and implanted electric stimulation of peripheral nerves. In: Bonica JJ, ed. The Management of Pain. Vol 2, 2nd ed. Philadelphia: Lea and Febiger; 1990:1852-1861.
    • (1990) The Management of Pain , vol.2 , pp. 1852-1861
    • Sjolund, B.1    Eriksson, M.2    Loeser, J.3
  • 9
    • 0344406124 scopus 로고    scopus 로고
    • Transcutaneous electrical nerve stimulation (TENS) can reduce postoperative analgesic consumption. A meta-analysis with assessment of optimal treatment parameters for postoperative pain
    • DOI 10.1016/S1090-3801(02)00098-8, PII S1090380102000988
    • Bjordal JM, Johnson MI, Ljunggreen AE. Transcutaneous electrical nerve stimulation (TENS) can reduce postoperative analgesic consumption. A meta-analysis with assessment of optimal treatment parameters for postoperative pain. Eur J Pain. 2003;7:181-188. (Pubitemid 36330536)
    • (2003) European Journal of Pain , vol.7 , Issue.2 , pp. 181-188
    • Bjordal, J.M.1    Johnson, M.I.2    Ljunggreen, A.E.3
  • 10
    • 34547092421 scopus 로고    scopus 로고
    • Short-term efficacy of physical interventions in osteoarthritic knee pain. A systematic review and meta-analysis of randomized placebo-controlled trials
    • Bjordal JM, Johnson MI, Lopes-Martins R, et al. Short-term efficacy of physical interventions in osteoarthritic knee pain. A systematic review and meta-analysis of randomized placebo-controlled trials. BMC Musculoskelet Disord. 2007;8:51.
    • (2007) BMC Musculoskelet Disord , vol.8 , pp. 51
    • Bjordal, J.M.1    Johnson, M.I.2    Lopes-Martins, R.3
  • 11
    • 77954184962 scopus 로고    scopus 로고
    • Does transcutaneous electrical nerve stimulation (TENS) produce "dose-responses"? A review of chronic pain systematic reviews
    • Claydon LS, Chesterton LS. Does transcutaneous electrical nerve stimulation (TENS) produce "dose-responses"? A review of chronic pain systematic reviews. Phys Ther Rev. 2008;13:450-463.
    • (2008) Phys Ther Rev , vol.13 , pp. 450-463
    • Claydon, L.S.1    Chesterton, L.S.2
  • 12
    • 44949154382 scopus 로고    scopus 로고
    • Does the pulse frequency of transcutaneous electrical nerve stimulation (TENS) influence hypoalgesia?. A systematic review of studies using experimental pain and healthy human participants
    • DOI 10.1016/j.physio.2006.12.011, PII S0031940607000338
    • Chen CC, Tabasam G, Johnson MI. Does the pulse frequency of transcutaneous electrical nerve stimulation (TENS) influence hypoalgesia? A systematic review of studies using experimental pain and healthy human participants. Physiotherapy. 2008;94:11-20. (Pubitemid 351819306)
    • (2008) Physiotherapy , vol.94 , Issue.1 , pp. 11-20
    • Chen, C.-C.1    Tabasam, G.2    Johnson, M.I.3
  • 13
    • 39649086187 scopus 로고    scopus 로고
    • Hand searching versus electronic searching to identify reports of randomized trials
    • Hopewell S, Clarke MJ, Lefebvre C, et al. Hand searching versus electronic searching to identify reports of randomized trials. Cochrane Database Syst Rev. 2007;2:MR000001.
    • (2007) Cochrane Database Syst Rev , vol.2
    • Hopewell, S.1    Clarke, M.J.2    Lefebvre, C.3
  • 15
    • 11944272254 scopus 로고
    • A power primer
    • Cohen J. A power primer. Psychol Bull. 1992;112:155-159.
    • (1992) Psychol Bull , vol.112 , pp. 155-159
    • Cohen, J.1
  • 16
    • 0037022272 scopus 로고    scopus 로고
    • The landscape and lexicon of blinding in randomized trials
    • Schulz K, Chalmers I, Altman DG. The landscape and lexicon of blinding in randomized trials. Ann Intern Med. 2002;136:254-259. (Pubitemid 34118130)
    • (2002) Annals of Internal Medicine , vol.136 , Issue.3 , pp. 254-259
    • Schulz, K.F.1    Chalmers, I.2    Altman, D.G.3
  • 17
    • 0032585188 scopus 로고    scopus 로고
    • The unpredictability paradox: Review of empirical comparisons of randomised and non-randomised clinical trials
    • Kunz R, Oxman AD. The unpredictability paradox: review of empirical comparisons of randomized and non-randomized clinical trials. BMJ. 1998;317:1185-1190. (Pubitemid 28488507)
    • (1998) British Medical Journal , vol.317 , Issue.7167 , pp. 1185-1190
    • Kunz, R.1    Oxman, A.D.2
  • 18
    • 77957184661 scopus 로고
    • Quality scores are useless and potentially misleading
    • Greenland S. Quality scores are useless and potentially misleading. Am J Epidemiol. 1994;140:300-301.
    • (1994) Am J Epidemiol , vol.140 , pp. 300-301
    • Greenland, S.1
  • 20
    • 0032558314 scopus 로고    scopus 로고
    • Does quality of reports of randomised trials affect estimates of intervention efficacy reported in meta-analyses?
    • DOI 10.1016/S0140-6736(98)01085-X
    • Moher D, Pham B, Jones A, et al. Does the quality of reports of randomized trials affect estimates of intervention efficacy reported in meta-analyses? Lancet. 1998;352:609-613. (Pubitemid 28380142)
    • (1998) Lancet , vol.352 , Issue.9128 , pp. 609-613
    • Moher, D.1    Pham, B.2    Jones, A.3    Cook, D.J.4    Jadad, A.R.5    Moher, M.6    Tugwell, P.7    Klassen, T.P.8
  • 21
    • 0013145469 scopus 로고    scopus 로고
    • Transcutaneous electrical nerve stimulation (TENS)
    • Kitchen S, ed, 11th ed. Edinburgh: Churchill-Livingstone
    • Johnson MI. Transcutaneous Electrical Nerve Stimulation (TENS). In: Kitchen S, ed. Electrotherapy: Evidence Based Practice. 11th ed. Edinburgh: Churchill-Livingstone; 2001:259-286.
    • (2001) Electrotherapy: Evidence Based Practice , pp. 259-286
    • Johnson, M.I.1
  • 23
    • 0028861454 scopus 로고
    • Best evidence synthesis: An intelligent alternative to meta-analysis
    • Slavin RE. Best evidence synthesis: an intelligent alternative to meta-analysis. J Clin Epidemiol. 1995;48:9-18.
    • (1995) J Clin Epidemiol , vol.48 , pp. 9-18
    • Slavin, R.E.1
  • 25
    • 0024638447 scopus 로고
    • Effect sizes for interpreting changes in health status
    • Kazis L, Anderson J, Meenan R. Effect sizes for interpreting changes in health status. Med Care. 1989;27:s179-s189.
    • (1989) Med Care , vol.27
    • Kazis, L.1    Anderson, J.2    Meenan, R.3
  • 26
    • 0029811220 scopus 로고    scopus 로고
    • Manipulation of transcutaneous electrical nerve stimulation variables has no effect on two models of experimental pain in humans
    • DOI 10.1097/00002508-199612000-00009
    • Foster NE, Baxter F, Walsh DM, et al. Manipulation of transcutaneous electrical nerve stimulation variables has no effect on two models of experimental pain in humans. Clin J Pain. 1996;12:301-310. (Pubitemid 26415056)
    • (1996) Clinical Journal of Pain , vol.12 , Issue.4 , pp. 301-310
    • Foster, N.E.1    Baxter, F.2    Walsh, D.M.3    Baxter, G.D.4    Allen, J.M.5
  • 27
    • 0037344153 scopus 로고    scopus 로고
    • An investigation into the analgesic effects of interferential currents and transcutaneous electrical nerve stimulation on experimentally induced ischemic pain in otherwise pain-free volunteers
    • Johnson MI, Tabasam G. An investigation into the analgesic effects of interferential and transcutaneous electrical nerve stimulation on experimentally induced ischemic pain in otherwise pain-free volunteers. Phys Ther. 2003;83:208-223. (Pubitemid 36348981)
    • (2003) Physical Therapy , vol.83 , Issue.3 , pp. 208-223
    • Johnson, M.I.1    Tabasam, G.2
  • 28
    • 80051800748 scopus 로고    scopus 로고
    • Chapter 12: Investigating the effect of low frequency TENS on pain intensity and pain unpleasantness of the ischemic pain tourniquet test using healthy female volunteers
    • Kirk K, PhD Thesis. Edinburgh: Queen Margaret University College
    • Kirk K. Chapter 12: Investigating the effect of low frequency TENS on pain intensity and pain unpleasantness of the ischemic pain tourniquet test using healthy female volunteers. In: Kirk K. The Influence of Stimulus Control on the Effects of Transcutaneous Electrical Nerves Stimulation (TENS) on Experimental Ischemic Pain (PhD Thesis). Edinburgh: Queen Margaret University College; 1998:183-199.
    • (1998) The Influence of Stimulus Control on the Effects of Transcutaneous Electrical Nerves Stimulation (TENS) on Experimental Ischemic Pain , pp. 183-199
    • Kirk, K.1
  • 29
    • 80051800748 scopus 로고    scopus 로고
    • Chapter 11: Investigating the effect of high frequency TENS on pain intensity and pain unpleasantness of the ischemic pain tourniquet test using healthy female volunteers
    • Kirk K, PhD Thesis. Edinburgh: Queen Margaret University College
    • Kirk K. Chapter 11: Investigating the effect of high frequency TENS on pain intensity and pain unpleasantness of the ischemic pain tourniquet test using healthy female volunteers. In: Kirk K. The Influence of Stimulus Control on the Effects of Transcutaneous Electrical Nerves Stimulation (TENS) on Experimental Ischemic Pain (PhD Thesis). Edinburgh: Queen Margaret University College; 1998:166-182.
    • (1998) The Influence of Stimulus Control on the Effects of Transcutaneous Electrical Nerves Stimulation (TENS) on Experimental Ischemic Pain , pp. 166-182
    • Kirk, K.1
  • 30
    • 80051800748 scopus 로고    scopus 로고
    • Chapter 13: Investigating the effect of high and low frequency TENS on pain intensity and pain unpleasantness of the ischemic pain tourniquet test using healthy female volunteers
    • Kirk K, PhD Thesis. Edinburgh: Queen Margaret University College
    • Kirk K. Chapter 13: Investigating the effect of high and low frequency TENS on pain intensity and pain unpleasantness of the ischemic pain tourniquet test using healthy female volunteers. In: Kirk K. The Influence of Stimulus Control on the Effects of Transcutaneous Electrical Nerves Stimulation (TENS) on Experimental Ischemic Pain (PhD Thesis). Edinburgh: Queen Margaret University College; 1998:200-213.
    • (1998) The Influence of Stimulus Control on the Effects of Transcutaneous Electrical Nerves Stimulation (TENS) on Experimental Ischemic Pain , pp. 200-213
    • Kirk, K.1
  • 31
    • 0021131698 scopus 로고
    • Modification of induced ischaemic pain by transcutaneous electrical nerve stimulation
    • DOI 10.1016/0304-3959(84)90809-1
    • Roche PA, Gijsbers K, Belch JJ, et al. Modification of induced ischemic pain by transcutaneous electrical nerve stimulation. Pain. 1984;20:45-52. (Pubitemid 14033863)
    • (1984) Pain , vol.20 , Issue.1 , pp. 45-52
    • Roche, P.A.1    Gijsbers, K.2    Belch, J.J.F.3    Forbes, C.D.4
  • 32
    • 0019481436 scopus 로고
    • Failure of transcutaneous electrical stimulation to alleviate experimental tourniquet pain
    • Rosenblatt RM, Hetherington A. Failure of transcutaneous electrical stimulation to alleviate experimental tourniquet pain. Anesth Analg. 1981;60:720-722. (Pubitemid 11020212)
    • (1981) Anesthesia and Analgesia , vol.60 , Issue.10 , pp. 720-722
    • Rosenblatt, R.M.1    Hetherington, A.2
  • 33
    • 0028965253 scopus 로고
    • A double-blind investigation of the hypoalgesic effects of transcutaneous electrical nerve stimulation upon experimentally-induced ischemic pain
    • Walsh DM, Liggett C, Baxter D, et al. A double-blind investigation of the hypoalgesic effects of transcutaneous electrical nerve stimulation upon experimentally-induced ischemic pain. Pain. 1995;61:39-45.
    • (1995) Pain , vol.61 , pp. 39-45
    • Walsh, D.M.1    Liggett, C.2    Baxter, D.3
  • 34
    • 0035203015 scopus 로고    scopus 로고
    • The effect of three electrotherapeutic modalities upon peripheral nerve conduction and mechanical pain threshold
    • DOI 10.1046/j.1365-2281.2001.00374.x
    • Alves-Guerreiro J, Noble JG, Lowe AS, et al. The effect of three electrotherapeutic modalities upon peripheral nerve conduction and mechanical pain threshold. Clin Physiol. 2001;21:704-711. (Pubitemid 33114708)
    • (2001) Clinical Physiology , vol.21 , Issue.6 , pp. 704-711
    • Alves-Guerreiro, J.1    Noble, J.G.2    Lowe, A.S.3    Walsh, D.M.4
  • 35
    • 66349120818 scopus 로고    scopus 로고
    • Influence of choice of electrical stimulation site on peripheral neurophysiological and hypoalgesic effects
    • Cheing GL, Chan WW. Influence of choice of electrical stimulation site on peripheral neurophysiological and hypoalgesic effects. J Rehabil Med. 2009;41:412-417.
    • (2009) J Rehabil Med , vol.41 , pp. 412-417
    • Cheing, G.L.1    Chan, W.W.2
  • 36
    • 70349459738 scopus 로고    scopus 로고
    • An investigation into the effects of frequency-modulated transcutaneous electrical nerve stimulation (TENS) on experimentally-induced pressure pain in healthy human participants
    • Chen CC, Johnson MI. An investigation into the effects of frequency-modulated transcutaneous electrical nerve stimulation (TENS) on experimentally-induced pressure pain in healthy human participants. J Pain. 2009;10:1029-1037.
    • (2009) J Pain , vol.10 , pp. 1029-1037
    • Chen, C.C.1    Johnson, M.I.2
  • 37
    • 0142165211 scopus 로고    scopus 로고
    • Effects of TENS frequency, intensity and stimulation site parameter manipulation on pressure pain thresholds in healthy human subjects
    • DOI 10.1016/S0304-3959(03)00292-6
    • Chesterton LS, Foster NE, Wright CC, et al. Effects of TENS frequency, intensity and stimulation site parameter manipulation on pressure pain thresholds in healthy human subjects. Pain. 2003;106:73-80. (Pubitemid 37329616)
    • (2003) Pain , vol.106 , Issue.1-2 , pp. 73-80
    • Chesterton, L.S.1    Foster, N.E.2    Wright, C.C.3    Baxter, G.D.4    Barlas, P.5
  • 38
    • 0036711511 scopus 로고    scopus 로고
    • Sensory stimulation (TENS): Effects of parameter manipulation on mechanical pain thresholds in healthy human subjects
    • DOI 10.1016/S0304-3959(02)00118-5, PII S0304395902001185
    • Chesterton LS, Barlas P, Foster NE, et al. Sensory stimulation (TENS): effects of parameter manipulation on mechanical pain thresholds in healthy human subjects. Pain. 2002;99:253-262. (Pubitemid 35247548)
    • (2002) Pain , vol.99 , Issue.1-2 , pp. 253-262
    • Chesterton, L.S.1    Barlas, P.2    Foster, N.E.3    Lundeberg, T.4    Wright, C.C.5    Baxter, G.D.6
  • 39
    • 44649157012 scopus 로고    scopus 로고
    • Effects of simultaneous dual-site TENS stimulation on experimental pain
    • Claydon LS, Chesterton LS, Sim J, et al. Effects of simultaneous dual-site TENS stimulation on experimental pain. Eur J Pain. 2008;12:696-704.
    • (2008) Eur J Pain , vol.12 , pp. 696-704
    • Claydon, L.S.1    Chesterton, L.S.2    Sim, J.3
  • 41
    • 67049092881 scopus 로고    scopus 로고
    • An investigation of the hypoalgesic effects of TENS delivered by glove electrode
    • Cowan S, McKenna J, McCrum-Gardner E, et al. An investigation of the hypoalgesic effects of TENS delivered by glove electrode. J Pain. 2009;10:694-701.
    • (2009) J Pain , vol.10 , pp. 694-701
    • Cowan, S.1    McKenna, J.2    McCrum-Gardner, E.3
  • 42
    • 73449123447 scopus 로고    scopus 로고
    • Effects of intensity of transcutaneous electrical nerve stimulation (TENS) on pressure pain threshold and blood pressure in healthy humans
    • Lazarou L, Kitsios A, Lazarou I, et al. Effects of intensity of transcutaneous electrical nerve stimulation (TENS) on pressure pain threshold and blood pressure in healthy humans. Clin J Pain. 2009;25:773-780.
    • (2009) Clin J Pain , vol.25 , pp. 773-780
    • Lazarou, L.1    Kitsios, A.2    Lazarou, I.3
  • 43
    • 0032862523 scopus 로고    scopus 로고
    • Comparative analgesic effects of H-wave therapy and transcutaneous electrical nerve stimulation on pain threshold in humans
    • DOI 10.1016/S0003-9993(99)90051-5
    • McDowell BC, McCormack K, Walsh DM, et al. Comparative analgesic effects of H-wave therapy and transcutaneous electrical nerve stimulation on pain threshold in humans. Arch Phys Med Rehabil. 1999;80:1001-1004. (Pubitemid 29439310)
    • (1999) Archives of Physical Medicine and Rehabilitation , vol.80 , Issue.9 , pp. 1001-1004
    • McDowell, B.C.1    McCormack, K.2    Walsh, D.M.3    Baxter, D.G.4    Allen, J.M.5
  • 44
    • 70149109791 scopus 로고    scopus 로고
    • Transcutaneous electrical nerve stimulation and transcutaneous spinal electroanalgesia: A preliminary efficacy and mechanisms based investigation
    • Palmer S, Cramp F, Propert K, et al. Transcutaneous electrical nerve stimulation and transcutaneous spinal electroanalgesia: a preliminary efficacy and mechanisms based investigation. Physiotherapy. 2009;95:185-191.
    • (2009) Physiotherapy , vol.95 , pp. 185-191
    • Palmer, S.1    Cramp, F.2    Propert, K.3
  • 45
    • 0026732954 scopus 로고
    • The effect of pain quality on the efficacy of conventional TENS
    • Simmonds M, Wessel J, Scudds R. The effect of pain quality on the efficacy of conventional TENS. Physiother Can. 1992;44:35-40.
    • (1992) Physiother Can , vol.44 , pp. 35-40
    • Simmonds, M.1    Wessel, J.2    Scudds, R.3
  • 46
    • 0031706062 scopus 로고    scopus 로고
    • Transcutaneous electrical nerve stimulation: Effect on peripheral nerve conduction, mechanical pain threshold, and tactile threshold in humans
    • DOI 10.1016/S0003-9993(98)90170-8
    • Walsh DM, Lowe AS, McCormack K, et al. Transcutaneous electrical nerve stimulation: effect on peripheral nerve conduction, mechanical pain threshold, and tactile threshold in humans. Arch Phys Med Rehabil. 1998;79:1051-1058. (Pubitemid 28419311)
    • (1998) Archives of Physical Medicine and Rehabilitation , vol.79 , Issue.9 , pp. 1051-1058
    • Walsh, D.M.1    Lowe, A.S.2    McCormack, K.3    Willer, J.-C.4    Baxter, G.D.5    Allen, J.M.6
  • 47
    • 0029056586 scopus 로고
    • Transcutaneous electrical nerve stimulation. Relevance of stimulation parameters to neurophysiological and hypoalgesic effects
    • Walsh DM, Foster NE, Baxter GD, et al. Transcutaneous electrical nerve stimulation. Relevance of stimulation parameters to neurophysiological and hypoalgesic effects. Am J Phys Med Rehabil. 1995;74:199-206.
    • (1995) Am J Phys Med Rehabil , vol.74 , pp. 199-206
    • Walsh, D.M.1    Foster, N.E.2    Baxter, G.D.3
  • 48
    • 0026469525 scopus 로고
    • Use of transcutaneous electrical nerve stimulation for fingertip analgesic: A pilot study
    • Webster DP, Pellegrini L, Duffy K. Use of transcutaneous electrical nerve stimulation for fingertip analgesic: a pilot study. Ann Emerg Med. 1992;21:1472-1475.
    • (1992) Ann Emerg Med , vol.21 , pp. 1472-1475
    • Webster, D.P.1    Pellegrini, L.2    Duffy, K.3
  • 49
    • 34748853625 scopus 로고    scopus 로고
    • Alternating Frequencies of Transcutaneous Electric Nerve Stimulation: Does it Produce Greater Analgesic Effects on Mechanical and Thermal Pain Thresholds?
    • DOI 10.1016/j.apmr.2007.07.017, PII S0003999307012919
    • Tong KC, Lo SK, Cheing GL. Alternating frequencies of transcutaneous electric nerve stimulation: does it produce greater analgesic effects on mechanical and thermal pain thresholds? Arch Phys Med Rehabil. 2007;88:1344-1349. (Pubitemid 47483668)
    • (2007) Archives of Physical Medicine and Rehabilitation , vol.88 , Issue.10 , pp. 1344-1349
    • Tong, K.C.1    Lo, S.K.2    Cheing, G.L.3
  • 50
    • 0037272805 scopus 로고    scopus 로고
    • Analgesic effects of transcutaneous electrical nerve stimulation and interferential currents on heat pain in healthy subjects
    • DOI 10.1080/16501970306101
    • Cheing G L Y, Hui-Chan C W Y. Analgesic effects of transcutaneous electrical nerve stimulation and interferential currents on heat pain in healthy subjects. J Rehabil Med. 2003;35:15-19. (Pubitemid 36204067)
    • (2003) Journal of Rehabilitation Medicine , vol.35 , Issue.1 , pp. 15-19
    • Cheing, G.L.Y.1    Hui-Chan, C.W.Y.2
  • 51
    • 0346728914 scopus 로고    scopus 로고
    • Effects of electric stimulation on C and a delta fiber-mediated thermal perception thresholds
    • DOI 10.1016/S0003-9993(03)00432-5
    • Palmer ST, Martin DJ, Steedman WM, et al. Effects of electrical stimulation on C and A delta fiber-mediated thermal perception thresholds. Arch Phys Med Rehabil. 2004;85:119-128. (Pubitemid 38049602)
    • (2004) Archives of Physical Medicine and Rehabilitation , vol.85 , Issue.1 , pp. 119-128
    • Palmer, S.T.1    Martin, D.J.2    Steedman, W.M.3    Ravey, J.4
  • 52
    • 0142058297 scopus 로고    scopus 로고
    • Psychophysical responses to experimentally induced heat and cold pain before, during, and after transcutaneous electrical nerve stimulation
    • DOI 10.1046/j.1525-1403.2003.03030.x
    • Tulgar M, Tulgar O, Herken H. Psychophysical response to experimentally induced heat and cold pain before, during and after transcutaneous electrical nerve stimulation. Neuromodulation. 2003;6:229-236. (Pubitemid 37266706)
    • (2003) Neuromodulation , vol.6 , Issue.4 , pp. 229-236
    • Tulgar, M.1    Tulgar, O.2    Herken, H.3
  • 53
    • 0742306368 scopus 로고    scopus 로고
    • Effects of acupoints TENS on heat pain threshold in normal subjects
    • Wang N, Hui-Chan C. Effect of acupoint TENS on heat pain threshold in normal subjects. Chin Med J. 2003;116:1864-1868. (Pubitemid 38159887)
    • (2003) Chinese Medical Journal , vol.116 , Issue.12 , pp. 1864-1868
    • Wang, N.1    Hui-Chan, C.2
  • 54
    • 0021165568 scopus 로고
    • Effects of acupuncture and transcutaneous electrical nerve stimulation on cold-induced pain in normal subjects
    • DOI 10.1016/0022-3999(84)90052-7
    • Ashton H, Ebenezer I, Golding JF, et al. Effects of acupuncture and transcutaneous electrical nerve stimulation on cold-induced pain in normal subjects. J Psychosom Res. 1984;28:301-308. (Pubitemid 14045929)
    • (1984) Journal of Psychosomatic Research , vol.28 , Issue.4 , pp. 301-308
    • Ashton, H.1    Ebenezer, I.2    Golding, J.F.3    Thompson, J.W.4
  • 55
    • 0033395939 scopus 로고    scopus 로고
    • A double blind placebo controlled investigation into the analgesic effects of inferential currents (IFC) and transcutaneous electrical nerve stimulation (TENS) on cold-induced pain in healthy subjects
    • Johnson MI, Tabasam G. A double blind placebo controlled investigation into the analgesic effects of inferential currents (IFC) and transcutaneous electrical nerve stimulation (TENS) on cold-induced pain in healthy subjects. Physiother Theory Pract. 1999;15:217-233. (Pubitemid 30019161)
    • (1999) Physiotherapy Theory and Practice , vol.15 , Issue.4 , pp. 217-233
    • Johnson, M.I.1    Tabasam, G.2
  • 56
    • 0024433134 scopus 로고
    • Analgesic effects of different frequencies of transcutaneous electrical nerve stimulation on cold-induced pain in normal subjects
    • DOI 10.1016/0304-3959(89)90010-9
    • Johnson MI, Ashton CH, Bousfield DR, et al. Analgesic effects of different frequencies of transcutaneous electrical nerve stimulation on cold-induced pain in normal subjects. Pain. 1989;39:231-236. (Pubitemid 19281465)
    • (1989) Pain , vol.39 , Issue.2 , pp. 231-236
    • Johnson, M.I.1    Ashton, C.H.2    Bousfield, D.R.3    Thompson, J.W.4
  • 57
    • 0025981342 scopus 로고
    • Analgesic effects of different pulse patterns of transcutaneous electrical nerve stimulation on cold-induced pain in normal subjects
    • Johnson MI, Ashton CH, Bousfield DR, et al. Analgesic effects of different pulse patterns of transcutaneous electrical nerve stimulation on cold-induced pain in normal subjects. J Psychosom Res. 1991;35:313-321.
    • (1991) J Psychosom Res , vol.35 , pp. 313-321
    • Johnson, M.I.1    Ashton, C.H.2    Bousfield, D.R.3
  • 58
    • 0027102132 scopus 로고
    • Analgesic effects of acupuncture-like transcutaneous electrical nerve stimulation (TENS) on cold-induced pain (cold-pressor pain) in normal subjects
    • Johnson MI, Ashton CH, Thompson JW. Analgesic effects of acupuncture-like transcutaneous electrical nerve stimulation (TENS) on cold induced pain (cold pressor pain) in normal subjects. Eur J Pain. 1992;13:101-108. (Pubitemid 23016410)
    • (1992) European Journal of Pain , vol.13 , Issue.4 , pp. 101-108
    • Johnson, M.I.1    Ashton, C.H.2    Thompson, J.W.3
  • 59
    • 0034112914 scopus 로고    scopus 로고
    • A controlled study on the effects of transcutaneous electrical nerve stimulation and interferential therapy upon the RIII nociceptive and H- reflexes in humans
    • DOI 10.1053/apmr.2000.0810324
    • Cramp FL, Noble G, Lowe AS, et al. A controlled study of the effects of transcutaneous electrical nerve stimulation and interferential therapy upon the RIII nociceptive and H-reflexes in humans. Arch Phys Med Rehabil. 2000;81:324-333. (Pubitemid 30149282)
    • (2000) Archives of Physical Medicine and Rehabilitation , vol.81 , Issue.3 , pp. 324-333
    • Cramp, F.L.1    Noble, G.2    Lowe, A.S.3    Walsh, D.M.4    Willer, J.C.5
  • 60
    • 0034023107 scopus 로고    scopus 로고
    • Study of the effects of various transcutaneous electrical nerve stimulation (TENS) parameters upon the RIII nociceptive and H-reflexes in humans
    • DOI 10.1046/j.1365-2281.2000.00246.x
    • Walsh DM, Noble G, Baxter GD, et al. Study of the effects of various transcutaneous electrical nerve stimulation (TENS) parameters upon the RIII nociceptive and H-reflexes in humans. Clin Physiol. 2000;20:191-199. (Pubitemid 30311832)
    • (2000) Clinical Physiology , vol.20 , Issue.3 , pp. 191-199
    • Walsh, D.M.1    Noble, G.2    Baxter, G.D.3    Allen, J.M.4
  • 61
    • 0024307604 scopus 로고
    • Comparison of effects of transcutaneous electrical nerve stimulation of auricular, somatic, and the combination of auricular and somatic acupuncture points on experimental pain threshold
    • Lein DH, Clelland JA, Knowles CJ, et al. Comparison of the effects of transcutaneous electrical nerve stimulation of auricular, somatic and the combination of auricular and stigmatic acupuncture points on experimental pain threshold. Phys Ther. 1989;69:671-678. (Pubitemid 19195154)
    • (1989) Physical Therapy , vol.69 , Issue.8 , pp. 671-678
    • Lein Jr., D.H.1    Clelland, J.A.2    Knowles, C.J.3    Jackson, J.R.4
  • 62
    • 3543151391 scopus 로고    scopus 로고
    • The effects of transcutaneous electrical nerve stimulation on experimental pain and sympathetic nervous system response
    • DOI 10.1111/j.1526-4637.2004.04027.x
    • Reeves JL, Graff-Radford SB, Shipman D. The effects of transcutaneous electrical nerve stimulation on experimental pain and sympathetic nervous system response. Pain Med. 2004;5:150-161. (Pubitemid 39029247)
    • (2004) Pain Medicine , vol.5 , Issue.2 , pp. 150-161
    • Reeves II, J.L.1    Radford-Graff, S.B.2    Shipman, D.3
  • 63
    • 0026630321 scopus 로고
    • Alterations in electrical pain thresholds by use of acupuncture-like transcutaneous electrical nerve stimulation in pain-free subjects
    • Rieb L, Pomeranz B. Alterations in electrical pain thresholds by use of acupuncture-like transcutaneous electrical nerve stimulation in pain-free subjects. Phys Ther. 1992;72:658-667.
    • (1992) Phys Ther , vol.72 , pp. 658-667
    • Rieb, L.1    Pomeranz, B.2
  • 66
    • 0030273755 scopus 로고    scopus 로고
    • Lack of effect of transcutaneous electrical nerve stimulation upon experimentally induced delayed onset muscle soreness in humans
    • DOI 10.1016/0304-3959(96)03124-7, PII S0304395996031247
    • Craig JA, Cunningham MB, Walsh DM, et al. Lack of effect of transcutaneous electrical nerve stimulation upon experimentally induced delayed onset muscle soreness. Pain. 1996;67:285-289. (Pubitemid 26375344)
    • (1996) Pain , vol.67 , Issue.2-3 , pp. 285-289
    • Craig, J.A.1    Cunningham, M.B.2    Walsh, D.M.3    Baxter, G.D.4    Allen, J.M.5
  • 67
    • 39549107421 scopus 로고    scopus 로고
    • Is mechanical pain threshold after transcutaneous electrical nerve stimulation (TENS) increased locally and unilaterally? A randomized placebo-controlled trial in healthy subjects
    • Aarskog R, Johnson MI, Demmink JH, et al. Is mechanical pain threshold after transcutaneous electrical nerve stimulation (TENS) increased locally and unilaterally? A randomized placebo-controlled trial in healthy subjects. Physiother Res Int. 2007;12:251-263.
    • (2007) Physiother Res Int , vol.12 , pp. 251-263
    • Aarskog, R.1    Johnson, M.I.2    Demmink, J.H.3
  • 68
    • 39049165301 scopus 로고    scopus 로고
    • An investigation into the effect of electrode placement of transcutaneous electrical nerve stimulation (TENS) on experimentally induced ischemic pain in healthy human participants
    • DOI 10.1097/AJP.0b013e31814b86a9, PII 0000250820071100000001
    • Brown L, Tabasam G, Bjordal JM, et al. An investigation into the effect of electrode placement of transcutaneous electrical nerve stimulation (TENS) on experimentally induced ischemic pain in healthy human participants. Clin J Pain. 2007;23:735-743. (Pubitemid 351339407)
    • (2007) Clinical Journal of Pain , vol.23 , Issue.9 , pp. 735-743
    • Brown, L.1    Tabasam, G.2    Bjordal, J.M.3    Johnson, M.I.4
  • 69
    • 0015621808 scopus 로고
    • Local analgesia from percutaneous electrical stimulation. A peripheral mechanism
    • Campbell JN, Taub A. Local analgesia from percutaneous electrical stimulation. A peripheral mechanism. Arch Neurol. 1973;28:347-350.
    • (1973) Arch Neurol , vol.28 , pp. 347-350
    • Campbell, J.N.1    Taub, A.2
  • 76
    • 80051782904 scopus 로고    scopus 로고
    • The effects of unilateral transcutaneous electrical nerve stimulation of the median nerve on bilateral somatosensory thresholds
    • Dean J, Bowsher D, Johnson MI. The effects of unilateral transcutaneous electrical nerve stimulation of the median nerve on bilateral somatosensory thresholds. Clin Physiol Funct Imaging. 2006;6:31-48.
    • (2006) Clin Physiol Funct Imaging , vol.6 , pp. 31-48
    • Dean, J.1    Bowsher, D.2    Johnson, M.I.3
  • 77
    • 0001228686 scopus 로고
    • High and low frequency TENS in the treatment of induced musculoskeletal pain: A comparison study
    • Denegar CR, Huff C. High and low frequency TENS in the treatment of induced musculoskeletal pain: a comparison study. Athl Train. 1988;23:235-237.
    • (1988) Athl Train , vol.23 , pp. 235-237
    • Denegar, C.R.1    Huff, C.2
  • 78
    • 0024420552 scopus 로고
    • Influence of transcutaneous electrical nerve stimulation on pain, range of motion, and serum cortisol concentration in females experiencing delayed onset muscle soreness
    • Denegar C, Perrin DH, Rogol AD, et al. Influence of transcutaneous electrical nerve stimulation on pain, range of motion, and serum cortisol concentration in females experiencing delayed onset muscle soreness. J Orthop Sports Phys Ther. 1989;11:100-103. (Pubitemid 19228439)
    • (1989) Journal of Orthopaedic and Sports Physical Therapy , vol.11 , Issue.3 , pp. 100-103
    • Denegar, C.R.1    Perrin, D.H.2    Rogol, A.D.3    Rutt, R.4
  • 80
    • 0023887549 scopus 로고
    • Increase in muscular pain threshold following low frequency-high intensity peripheral conditioning stimulation in humans
    • Duranti R, Pantaleo T, Bellini F. Increase in muscular pain threshold following low frequency-high intensity peripheral conditioning stimulation in humans. Brain Res. 1988;452:66-72.
    • (1988) Brain Res , vol.452 , pp. 66-72
    • Duranti, R.1    Pantaleo, T.2    Bellini, F.3
  • 81
    • 0019444518 scopus 로고
    • The effects of non-painful transcutaneous electrical nerve stimulation on cutaneous pain threshold and muscular reflexes in normal men and in subjects with chronic pain
    • DOI 10.1016/0304-3959(81)90138-X
    • Francini F, Maresca M, Procacci P, et al. The effects of nonpainful transcutaneous electrical nerve stimulation on cutaneous pain threshold and muscular reflexes in normal men and in subjects with chronic pain. Pain. 1981;11:49-63. (Pubitemid 11047021)
    • (1981) Pain , vol.11 , Issue.1 , pp. 49-63
    • Francini, F.1    Maresca, M.2    Procacci, P.3    Zoppi, M.4
  • 82
    • 0028803945 scopus 로고
    • Analgesic effects induced by TENS and electroacupuncture with different types of stimulating electrodes on deep tissues in human subjects
    • Ishimaru K, Kawakita K, Sakita M. Analgesic effects induced by TENS and electroacupuncture with different types of stimulating electrodes on deep tissues in human subjects. Pain. 1995;63:181-187.
    • (1995) Pain , vol.63 , pp. 181-187
    • Ishimaru, K.1    Kawakita, K.2    Sakita, M.3
  • 83
    • 0022618039 scopus 로고
    • Effect of different forms of transcutaneous electrical nerve stimulation on experimental pain
    • Jette DU. Effect of different forms of transcutaneous electrical nerve stimulation on experimental pain. Phys Ther. 1986;66:187-190. (Pubitemid 16152713)
    • (1986) Physical Therapy , vol.66 , Issue.2 , pp. 187-190
    • Jette, D.U.1
  • 84
    • 13144274889 scopus 로고
    • Effects of TENS on the stimulated and nonstimulated sides-changes of pain threshold and skin temperature
    • Kudo S. Effects of TENS on the stimulated and nonstimulated sides-changes of pain threshold and skin temperature. J Phys Ther Sci. 1994;6:109-113.
    • (1994) J Phys Ther Sci , vol.6 , pp. 109-113
    • Kudo, S.1
  • 85
    • 12744259355 scopus 로고    scopus 로고
    • Gender differences in electrical pain threshold responses to transcutaneous electrical nerve stimulation (TENS)
    • Lund I, Lundeberg T, Kowalski J, et al. Gender differences in electrical pain threshold responses to transcutaneous electrical nerve stimulation (TENS). Neurosci Lett. 2005;375:75-80.
    • (2005) Neurosci Lett , vol.375 , pp. 75-80
    • Lund, I.1    Lundeberg, T.2    Kowalski, J.3
  • 87
    • 0032871144 scopus 로고    scopus 로고
    • Alteration of interferential current and transcutaneous electrical nerve stimulation frequency: Effects on nerve excitation
    • DOI 10.1016/S0003-9993(99)90062-X
    • Palmer ST, Martin DJ, Steedman WM, et al. Alteration of interferential current and transcutaneous electrical nerve stimulation frequency: effects on nerve excitation. Arch Phys Med Rehabil. 1999;80:1065-1071. (Pubitemid 29439321)
    • (1999) Archives of Physical Medicine and Rehabilitation , vol.80 , Issue.9 , pp. 1065-1071
    • Palmer, S.T.1    Martin, D.J.2    Steedman, W.M.3    Ravey, J.4
  • 88
    • 0019300927 scopus 로고
    • Experimental pain and transcutaneous electrical nerve stimulation at high frequency
    • Pertrovaara A. Experimental pain and transcutaneous electrical nerve stimulation at high frequency. Appl Neurophysiol. 1980;43:290-297.
    • (1980) Appl Neurophysiol , vol.43 , pp. 290-297
    • Pertrovaara, A.1
  • 89
    • 0019943671 scopus 로고
    • Dental analgesia produced by non-painful, low-frequency stimulation is not influenced by stress or reversed by naloxone
    • DOI 10.1016/0304-3959(82)90006-9
    • Pertovaara A, Kemppainen P, Johansson G, et al. Dental analgesia produced by non-painful low-frequency stimulation is not influenced by stress or reversed by naloxone. Pain. 1982;13:379-384. (Pubitemid 12053168)
    • (1982) Pain , vol.13 , Issue.4 , pp. 379-384
    • Pertovaara, A.1    Kemppainen, P.2    Johansson, G.3    Karonen, S.L.4
  • 90
    • 0030070938 scopus 로고    scopus 로고
    • A comparison of the effects of noxious and innocuous counterstimuli on experimentally induced itch and pain
    • DOI 10.1016/0304-3959(95)00080-1
    • Ward L, Wright E, McMahon SB. A comparison of the effects of noxious and innocuous counterstimuli on experimentally induced itch and pain. Pain. 1996;64:129-138. (Pubitemid 26062250)
    • (1996) Pain , vol.64 , Issue.1 , pp. 129-138
    • Ward, L.1    Wright, E.2    McMahon, S.B.3
  • 91
    • 0019418470 scopus 로고
    • Changes of cutaneous sensory thresholds induced by non-painful transcutaneous electrical nerve stimulation in normal subjects and in subjects with chronic pain
    • Zoppi M, Francini F, Maresca M, et al. Changes of cutaneous sensory thresholds induced by non-painful transcutaneous electrical nerve stimulation in normal subjects and in subjects with chronic pain. J Neurol Neurosurg Psychiatry. 1981;44:708-717. (Pubitemid 11028118)
    • (1981) Journal of Neurology Neurosurgery and Psychiatry , vol.44 , Issue.8 , pp. 708-717
    • Zoppi, M.1    Francini, F.2    Maresca, M.3    Procacci, P.4
  • 92
    • 34447552695 scopus 로고    scopus 로고
    • Increase of the heat pain threshold during and after high-frequency transcutaneous peripheral nerve stimulation in a group of normal subjects
    • Buonocore M, Camuzzini N. Increase of the heat pain threshold during and after high-frequency transcutaneous peripheral nerve stimulation in a group of normal subjects. Eura Medicophys. 2007;43:155-160.
    • (2007) Eura Medicophys , vol.43 , pp. 155-160
    • Buonocore, M.1    Camuzzini, N.2
  • 94
    • 33745427070 scopus 로고    scopus 로고
    • Peripheral nerve stimulation inhibits nociceptive processing: An electrophysiological study in healthy volunteers
    • DOI 10.1111/j.1525-1403.2005.00029.x
    • Ellrich J, Lamp S. Peripheral nerve stimulation inhibits nociceptive processing: an electrophysiological study in healthy volunteers. Neuromodulation. 2005;8:225-232. (Pubitemid 43942731)
    • (2005) Neuromodulation , vol.8 , Issue.4 , pp. 225-232
    • Ellrich, J.1    Lamp, S.2
  • 95
    • 0023039332 scopus 로고
    • Transcutaneous electrical nerve stimulation produces variable changes in somatosensory evoked potentials, sensory perception and pain threshold: Clinical implications for pain relief
    • Golding AF, Ashton H, Marsh R, et al. Transcutaneous electrical nerve stimulation produces variable changes in somatosensory evoked potentials, sensory perception and pain threshold: clinical implications for pain relief. J Neurol Neurosurg Psychiatry. 1986;49:1397-1406. (Pubitemid 17209056)
    • (1986) Journal of Neurology Neurosurgery and Psychiatry , vol.49 , Issue.12 , pp. 1397-1406
    • Golding, J.F.1    Ashton, H.2    Marsh, R.3    Thompson, J.W.4
  • 96
    • 0034175856 scopus 로고    scopus 로고
    • After-effect of transcutaneous electrical nerve stimulation (TENS) on pain-related evoked potentials and magnetic fields in normal subjects
    • DOI 10.1016/S1388-2457(99)00299-0, PII S1388245799002990
    • Hoshiyama M, Kakigi R. After-effect of transcutaneous electrical nerve stimulation (TENS) on pain-related evoked potentials and magnetic fields in normal subjects. Clin Neurophysiol. 2000;111:717-724. (Pubitemid 30155994)
    • (2000) Clinical Neurophysiology , vol.111 , Issue.4 , pp. 717-724
    • Hoshiyama, M.1    Kakigi, R.2
  • 97
    • 0025910683 scopus 로고
    • Modulation of heat pain perception by high frequency transcutaneous electrical nerve stimulation (TENS)
    • Marchand S, Bushnell C, Duncan GH. Modulation of heat pain perception by high frequency transcutaneous electrical nerve stimulation (TENS). Clin J Pain. 1991;7:122-129.
    • (1991) Clin J Pain , vol.7 , pp. 122-129
    • Marchand, S.1    Bushnell, C.2    Duncan, G.H.3
  • 98
    • 0033065511 scopus 로고    scopus 로고
    • Differential inhibitory effect on human nociceptive skin senses induced by local stimulation of thin cutaneous fibers
    • Nilsson HJ, Schuenborg J. Differential inhibitory effect on human nociceptive skin senses induced by local stimulation of thin cutaneous fibers. Pain. 1999;80:103-112.
    • (1999) Pain , vol.80 , pp. 103-112
    • Nilsson, H.J.1    Schuenborg, J.2
  • 99
    • 39749179049 scopus 로고    scopus 로고
    • Analgesic and antinociceptive effects of peripheral nerve neurostimulation in an advanced human experimental model
    • DOI 10.1016/j.ejpain.2007.07.013, PII S1090380107006192
    • Ristic D, Spangenberg P, Ellrich J. Analgesic and antinociceptive effects of peripheral nerve stimulation in an advanced human experimental model. Eur J Pain. 2008;12:480-490. (Pubitemid 351312892)
    • (2008) European Journal of Pain , vol.12 , Issue.4 , pp. 480-490
    • Ristic, D.1    Spangenberg, P.2    Ellrich, J.3
  • 100
    • 0018637105 scopus 로고
    • Transcutaneous electrical nerve stimulation and the reaction to experimental pain in human subjects
    • DOI 10.1016/0304-3959(79)90003-4
    • Woolf CJ. Transcutaneous electrical nerve stimulation and the reaction to experimental pain in human subjects. Pain. 1979;7:115-127. (Pubitemid 10198506)
    • (1979) Pain , vol.7 , Issue.2 , pp. 115-127
    • Woolf, C.J.1
  • 101
    • 0023137394 scopus 로고
    • Inhibition of the human flexion reflex by low intensity, high frequency transcutaneous electrical nerve stimulation (TENS) has a gradual onset and offset
    • DOI 10.1016/0304-3959(87)90119-9
    • Chan C W Y, Tsang H. Inhibition of the human flexion reflex by low intensity, high frequency transcutaneous electrical nerve stimulation has a gradual onset and offset. Pain. 1987;28:239-253. (Pubitemid 17008040)
    • (1987) Pain , vol.28 , Issue.2 , pp. 239-253
    • Chan, C.W.Y.1    Tsang, H.2
  • 102
    • 0031931502 scopus 로고    scopus 로고
    • Depressive effects of segmental and heterotopic application of transcutaneous electrical nerve stimulation and piezo-electric current on lower limb nociceptive flexion reflex in human subjects
    • DOI 10.1016/S0003-9993(98)90299-4
    • Danziger N, Rozenberg S, Bourgeois P, et al. Depressive effects of segmental and heterotopic application of transcutaneous electrical nerve stimulation and piezo-electric current on lower limb nociceptive flexion reflex in human subjects. Arch Phys Med Rehabil. 1998;79:191-200. (Pubitemid 28084176)
    • (1998) Archives of Physical Medicine and Rehabilitation , vol.79 , Issue.2 , pp. 191-200
    • Danziger, N.1    Rozenberg, S.2    Bourgeois, P.3    Charpentier, G.4    Willer, J.C.5
  • 103
    • 0021799365 scopus 로고
    • Thermal sensitivity in healthy subjects is decreased by a central mechanism after TNS
    • DOI 10.1016/0304-3959(85)90023-5
    • Eriksson M B E, Rosen I, Sjolund B. Thermal sensitivity in healthy subjects is decreased by a central mechanism after TNS. Pain. 1985;22:235-242. (Pubitemid 15043122)
    • (1985) Pain , vol.22 , Issue.3 , pp. 235-242
    • Eriksson, M.B.E.1    Rosen, I.2    Sjolund, B.3
  • 104
    • 0025868503 scopus 로고
    • The effects of auricular transcutaneous electrical nerve stimulation (TENS) on experimental pain threshold and autonomic function in healthy subjects
    • Johnson MI, Hajela VK, Ashton CH, et al. The effects of auricular transcutaneous electrical nerve stimulation (TENS) on experimental pain threshold and autonomic function in healthy subjects. Pain. 1991;46:337-342.
    • (1991) Pain , vol.46 , pp. 337-342
    • Johnson, M.I.1    Hajela, V.K.2    Ashton, C.H.3
  • 105
    • 0023934424 scopus 로고
    • Effect of transcutaneous electrical nerve stimulation at auricular points on experimental cutaneous pain threshold
    • Noling LB, Clelland JA, Jackson JR, et al. Effect of transcutaneous electrical nerve stimulation at auricular points on experimental cutaneous pain threshold. Phys Ther. 1988;68:328-332. (Pubitemid 18092997)
    • (1988) Physical Therapy , vol.68 , Issue.3 , pp. 328-332
    • Noling, L.B.1    Clelland, J.A.2    Jackson, J.R.3    Knowles, C.J.4
  • 106
    • 0022642227 scopus 로고
    • Effects of auricular transcutaneous electrical nerve stimulation on experimental pain threshold
    • Oliveri AC, Clelland JA, Jackson J, et al. Effects of auricular transcutaneous nerve stimulation on experimental pain threshold. Phys Ther. 1986;66:12-16. (Pubitemid 16154653)
    • (1986) Physical Therapy , vol.66 , Issue.1 , pp. 12-16
    • Oliveri, A.C.1    Clelland, J.A.2    Jackson, J.3    Knowles, C.4
  • 107
    • 0027200851 scopus 로고
    • Sine-wave auricular TENS produces frequency-dependent hypesthesia in the trigeminal nerve
    • Taylor DN, Katims JJ, Lorenz KY. Sine-wave auricular TENS produces frequency-dependent hyperesthesia in the trigeminal nerve. Clin J Pain. 1993;9:216-219. (Pubitemid 23275179)
    • (1993) Clinical Journal of Pain , vol.9 , Issue.3 , pp. 216-219
    • Taylor, D.N.1    Katims, J.J.2    Ng, L.K.Y.3
  • 108
    • 0022491066 scopus 로고
    • Transcutaneous electrical nerve stimulation characteristics for altering pain perception
    • Barr J, Nielsen D, Soderberg GL. Transcutaneous electrical nerve stimulation characteristics for altering pain perception. Phys Ther. 1986;66:1515-1521. (Pubitemid 16002398)
    • (1986) Physical Therapy , vol.66 , Issue.10 , pp. 1515-1521
    • Barr, J.O.1    Nielsen, D.H.2    Soderberg, G.L.3
  • 109
    • 0033024549 scopus 로고    scopus 로고
    • Transcutaneous electrical nerve stimulation: Nonparallel antinociceptive effects on chronic clinical pain and acute experimental pain
    • DOI 10.1016/S0003-9993(99)90142-9
    • Cheing GL, Hui-Chan CW. Transcutaneous electrical nerve stimulation: nonparallel antinociceptive effects on chronic clinical pain and acute experimental pain. Arch Phys Med Rehabil. 1999;80:305-312. (Pubitemid 29124750)
    • (1999) Archives of Physical Medicine and Rehabilitation , vol.80 , Issue.3 , pp. 305-312
    • Cheing, G.L.Y.1    Hui-Chan, C.W.Y.2
  • 110
    • 0022618039 scopus 로고
    • Effect of different forms of transcutaneous electrical nerve stimulation on experimental pain
    • Jette DU. Effect of different forms of transcutaneous electrical nerve stimulation on experimental pain. Phys Ther. 1986;66:192-193.
    • (1986) Phys Ther , vol.66 , pp. 192-193
    • Jette, D.U.1
  • 111
    • 0036028722 scopus 로고    scopus 로고
    • Modification of induced ischaemic pain by placebo electrotherapy
    • DOI 10.1080/09593980290058472
    • Roche PA, Tan HY, Stanton WR. Modification of induced ischemic pain by placebo electrotherapy. Physiother Theory Pract. 2002;18:131-139. (Pubitemid 35230878)
    • (2002) Physiotherapy Theory and Practice , vol.18 , Issue.3 , pp. 131-139
    • Roche, P.A.1    Tan, H.-Y.2    Stanton, W.R.3
  • 112
    • 80051796614 scopus 로고
    • Effects of TENS hyperstimulation on experimental pain threshold
    • Sagers M, Byrd KE. Effects of TENS hyperstimulation on experimental pain threshold. Phys Ther. 1983;63:750.
    • (1983) Phys Ther , vol.63 , pp. 750
    • Sagers, M.1    Byrd, K.E.2
  • 113
    • 0034208103 scopus 로고    scopus 로고
    • Effect of transcutaneous electrical nerve stimulation on pain perception threshold of human teeth: A double-blind, placebo-controlled study
    • Schafer E, Finkensiep H, Kaup M. Effect of transcutaneous electrical nerve stimulation on pain perception threshold of human teeth: a double-blind, placebo-controlled study. J Clin Oral Investig. 2000;4:81-86.
    • (2000) J Clin Oral Investig , vol.4 , pp. 81-86
    • Schafer, E.1    Finkensiep, H.2    Kaup, M.3
  • 114
    • 0028153965 scopus 로고
    • Pain and the placebo in rehabilitation using TENS and laser
    • Simmonds MJ, Kumar S. Pain and the placebo using in rehabilitation using TENS and laser. Disabil Rehabil. 1994;16:13-20. (Pubitemid 24044481)
    • (1994) Disability and Rehabilitation , vol.16 , Issue.1 , pp. 13-20
    • Simmonds, M.J.1    Kumar, S.2
  • 115
    • 11144339518 scopus 로고    scopus 로고
    • Painful and non-painful pressure sensations from human skeletal muscle
    • DOI 10.1007/s00221-004-1937-7
    • Graven-Nielsen T, Mense S, Arendt-Nielsen L. Painful and non-painful pressure sensations from human skeletal muscle. Exp Brain Res. 2004;159:273-283. (Pubitemid 40022216)
    • (2004) Experimental Brain Research , vol.159 , Issue.3 , pp. 273-283
    • Graven-Nielsen, T.1    Mense, S.2    Arendt-Nielsen, L.3
  • 117
    • 0018579159 scopus 로고
    • Excitability changes in peripheral nerve fibers after repetitive electrical stimulation. Implications in pain modulation
    • Ignelzi RJ, Nyquist JK. Excitability changes in peripheral nerve fibers after repetitive electrical stimulation: implications in pain relief. J Neurosurg. 1979;51:824-833. (Pubitemid 10157874)
    • (1979) Journal of Neurosurgery , vol.51 , Issue.6 , pp. 824-833
    • Ignelzi, R.J.1    Nyquist, J.K.2
  • 118
    • 42749108207 scopus 로고    scopus 로고
    • Transcutaneous electric nerve stimulation (TENS) for cancer pain in adults
    • Robb KA, Bennett MI, Johnson MI, et al. Transcutaneous electric nerve stimulation (TENS) for cancer pain in adults. Cochrane Database Syst Rev. 2008;3:CD006276.
    • (2008) Cochrane Database Syst Rev , vol.3
    • Robb, K.A.1    Bennett, M.I.2    Johnson, M.I.3
  • 119
    • 2342533088 scopus 로고    scopus 로고
    • Acupuncture and endorphins
    • Han JS. Acupuncture and endorphins. Neurosci Lett. 2004;361:258-261.
    • (2004) Neurosci Lett , vol.361 , pp. 258-261
    • Han, J.S.1
  • 120
    • 0025746705 scopus 로고
    • Effect of low-and highfrequency TENS on met-enkephalin-arg-phe and dynorphin a immunoreactivity in human lumbar CSF
    • Han JS, Chen XH, Sun SL, et al. Effect of low-and highfrequency TENS on Met-enkephalin-Arg-Phe and dynorphin A immunoreactivity in human lumbar CSF. Pain. 1991;47:295-298.
    • (1991) Pain , vol.47 , pp. 295-298
    • Han, J.S.1    Chen, X.H.2    Sun, S.L.3
  • 123
    • 77649239352 scopus 로고    scopus 로고
    • A new transient sham TENS device allows for investigator blinding while delivering a true placebo treatment
    • Rakel B, Cooper N, Adams HJ, et al. A new transient sham TENS device allows for investigator blinding while delivering a true placebo treatment. J Pain. 2010;11:230-238.
    • (2010) J Pain , vol.11 , pp. 230-238
    • Rakel, B.1    Cooper, N.2    Adams, H.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.