메뉴 건너뛰기




Volumn 142, Issue 3, 2011, Pages 865-889

Cytocompatibility of medical biomaterials containing nickel by osteoblasts: A systematic literature review

Author keywords

Cell proliferation; Cell viability; Cytocompatibility; Nickel; Osteoblasts

Indexed keywords

ALLOY; BIOMATERIAL; METAL ION; NICKEL; STAINLESS STEEL; TITANIUM;

EID: 80051785299     PISSN: 01634984     EISSN: 15590720     Source Type: Journal    
DOI: 10.1007/s12011-010-8798-7     Document Type: Review
Times cited : (35)

References (76)
  • 1
    • 0742265512 scopus 로고    scopus 로고
    • Metallic biomaterials
    • Black J, Hastings G (eds), Chapman & Hall, London
    • Breme J, Biehl V (1998) Metallic biomaterials. In: Black J, Hastings G (eds) Handbook of biomaterial properties. Chapman & Hall, London, pp 135-137
    • (1998) Handbook of Biomaterial Properties , pp. 135-137
    • Breme, J.1    Biehl, V.2
  • 2
    • 84856263955 scopus 로고    scopus 로고
    • Nitinol as a biomedical material
    • Buschow KH, Jürgen KH, Cahn RW, Flemings MC, Ilschner B, Kramer EJ, Mahajan S (eds), Elsevier, Amsterdam
    • Weber JH (2001) Nitinol as a biomedical material. In: Buschow KH, Jürgen KH, Cahn RW, Flemings MC, Ilschner B, Kramer EJ, Mahajan S (eds) Encyclopedia of materials-science and technology, vol 1-11. Elsevier, Amsterdam, pp 6155-6160
    • (2001) Encyclopedia of Materials-science and Technology , vol.1-11 , pp. 6155-6160
    • Weber, J.H.1
  • 3
    • 33749022602 scopus 로고    scopus 로고
    • Biomedical and dental materials: Introduction
    • Buschow KH, Jürgen KH, Cahn RW, Flemings MC, Ilschner B, Kramer EJ, Mahajan S (eds), Elsevier, Amsterdam
    • Williams DF (2001) Biomedical and dental materials: introduction. In: Buschow KH, Jürgen KH, Cahn RW, Flemings MC, Ilschner B, Kramer EJ, Mahajan S (eds) Encyclopedia of materials-science and technology, vol 1. Elsevier, Amsterdam, pp 584-592
    • (2001) Encyclopedia of Materials-science and Technology , vol.1 , pp. 584-592
    • Williams, D.F.1
  • 5
    • 0003109816 scopus 로고    scopus 로고
    • de Putter C, de Lange K, de Groot K, Lee AJC (eds), Elsevier, Amsterdam
    • Williams DF (1998) In: de Putter C, de Lange K, de Groot K, Lee AJC (eds) Advances in biomaterials. Elsevier, Amsterdam, pp 11-16
    • (1998) Advances in Biomaterials , pp. 11-16
    • Williams, D.F.1
  • 6
    • 15044364236 scopus 로고    scopus 로고
    • Assessing the biocompatibility of NiTi shape memory alloys used for medical applications
    • DOI 10.1007/s00216-004-2888-3
    • Es-Souni M, Es-Souni M, Fischer-Brandies H (2005) Assessing the biocompatibility of NiTi shape memory alloys used for medical applications. Anal Bioanal Chem 381:557-567 (Pubitemid 40379328)
    • (2005) Analytical and Bioanalytical Chemistry , vol.381 , Issue.3 , pp. 557-567
    • Es-Souni, M.1    Es-Souni, M.2    Fischer-Brandies, H.3
  • 8
    • 80051784395 scopus 로고    scopus 로고
    • American Society for Testing and Materials (ASTM) F1 136. Accessed 1 June 2010
    • American Society for Testing and Materials (ASTM) F1 136. Accessed 1 June 2010
  • 9
    • 79952110368 scopus 로고    scopus 로고
    • Trace metal release from orthodontic appliances by in vivo studies: A systematic literature review
    • doi:10.1007/s12011-009-8576-6
    • Mikulewicz M, Chojnacka K (2010) Trace metal release from orthodontic appliances by in vivo studies: a systematic literature review. Biol Trace Elem Res. doi:10.1007/s12011-009-8576-6
    • (2010) Biol Trace Elem Res.
    • Mikulewicz, M.1    Chojnacka, K.2
  • 10
    • 79955933302 scopus 로고    scopus 로고
    • Release of metal ions from orthodontic appliances by in vitro studies: A systematic literature review
    • doi:10.1007/s12011-010-8670-9
    • Mikulewicz M, Chojnacka K (2010) Release of metal ions from orthodontic appliances by in vitro studies: a systematic literature review. Biol Trace Elem Res. doi:10.1007/s12011-010-8670-9
    • (2010) Biol Trace Elem Res.
    • Mikulewicz, M.1    Chojnacka, K.2
  • 12
    • 0030270078 scopus 로고    scopus 로고
    • Biocompatibility testing of NiTi screws using immunohistochemistry on sections containing metallic implants
    • DOI 10.1002/(SICI)1097-4636(199610)32:2<243::AID-JBM14>3.3.CO;2-5
    • Berger-Gorbet M, Broxup B, Rivard C, Yahia LH (1996) Biocompatibility testing of NiTi screws using immunohistochemistry on sections containing metallic implants. J Biomed Mater Res 32:243-248 (Pubitemid 26320240)
    • (1996) Journal of Biomedical Materials Research , vol.32 , Issue.2 , pp. 243-248
    • Berger-Gorbet, M.1    Broxup, B.2    Rivard, C.3    Yahia, L'H.4
  • 15
    • 0036132139 scopus 로고    scopus 로고
    • Silver coated materials for external fixation devices: In vitro biocompatibility and genotoxicity
    • DOI 10.1016/S0142-9612(01)00198-3, PII S0142961201001983
    • Bosetti M, Massé A, Tobin E, Cannas M (2002) Silver coated materials for external fixation devices: in vitro biocompatibility and genotoxicity. Biomaterials 23:887-892 (Pubitemid 33108964)
    • (2002) Biomaterials , vol.23 , Issue.3 , pp. 887-892
    • Bosetti, M.1    Masse, A.2    Tobin, E.3    Cannas, M.4
  • 16
    • 0036020106 scopus 로고    scopus 로고
    • Interaction of spiral ganglion neuron processes with alloplastic materials in vitro
    • DOI 10.1016/S0378-5955(02)00355-6, PII S0378595502003556
    • Brors D, Aletsee C, Schwager K, Mlynski R, Hansen S, Schäfers M, Ryan AF, Dazert S (2002) Interaction of spiral ganglion neuron processes with alloplastic materials in vitro. Hear Res 167:110-121 (Pubitemid 34756855)
    • (2002) Hearing Research , vol.167 , Issue.1-2 , pp. 110-121
    • Brors, D.1    Aletsee, C.2    Schwager, K.3    Mlynski, R.4    Hansen, S.5    Schafers, M.6    Ryan, A.F.7    Dazert, S.8
  • 17
    • 33750525488 scopus 로고    scopus 로고
    • Cytotoxicity of polyethyleneimine (PEI), precursor base layer of polyelectrolyte multilayer films
    • DOI 10.1016/j.biomaterials.2006.09.026, PII S0142961206008349
    • Brunot C, Ponsonnet L, Lagneau C, Farge P, Picart C, Grosgogeat B (2007) Cytotoxicity of polyethyleneimine (PEI), precursor base layer of polyelectrolyte multilayer films. Biomaterials 28:632-640 (Pubitemid 44660075)
    • (2007) Biomaterials , vol.28 , Issue.4 , pp. 632-640
    • Brunot, C.1    Ponsonnet, L.2    Lagneau, C.3    Farge, P.4    Picart, C.5    Grosgogeat, B.6
  • 18
    • 55049123433 scopus 로고    scopus 로고
    • Evaluation of ion release, cytotoxicity, and platelet adhesion of electrochemical anodized 316 L stainless steel cardiovascular stents
    • Díaz M, Sevilla P, Galán AM, Escolar G, Engel E, Gil FJ (2008) Evaluation of ion release, cytotoxicity, and platelet adhesion of electrochemical anodized 316 L stainless steel cardiovascular stents. J Biomed Mater Res B Appl Biomater 87:555-61
    • (2008) J Biomed Mater Res B Appl Biomater , vol.87 , pp. 555-61
    • Díaz, M.1    Sevilla, P.2    Galán, A.M.3    Escolar, G.4    Engel, E.5    Gil, F.J.6
  • 19
    • 11044226495 scopus 로고    scopus 로고
    • Evaluation of mechanical properties and biological response of an alumina-forming Ni-free ferritic alloy
    • DOI 10.1016/j.biomaterials.2004.09.058, PII S0142961204008853
    • González-Carrasco JL, Ciapetti G, Montealegre MA, Pagani S, Chao J, Baldini N (2005) Evaluation of mechanical properties and biological response of analumina-forming Ni-free ferritic alloy. Biomaterials 26:3861-3871 (Pubitemid 40044761)
    • (2005) Biomaterials , vol.26 , Issue.18 , pp. 3861-3871
    • Gonzalez-Carrasco, J.L.1    Ciapetti, G.2    Montealegre, M.A.3    Pagani, S.4    Chao, J.5    Baldini, N.6
  • 20
    • 0035892408 scopus 로고    scopus 로고
    • Osteoblast cell death on methacrylate polymers involves apoptosis
    • DOI 10.1002/1097-4636(20011215)57:4<497::AID-JBM1195>3.0.CO;2-U
    • Gough JE, Downes S (2001) Osteoblast cell death on methacrylate polymers involves apoptosis. J Biomed Mater Res 57:497-505 (Pubitemid 32937530)
    • (2001) Journal of Biomedical Materials Research , vol.57 , Issue.4 , pp. 497-505
    • Gough, J.E.1    Downes, S.2
  • 21
    • 0036017271 scopus 로고    scopus 로고
    • Effect of metal alloy surface stresses on the viability of ROS-17/2.8 osteoblastic cells
    • DOI 10.1016/S0142-9612(02)00107-2, PII S0142961202001072
    • Kapanen A, Danilov A, Lehenkari P, Ryhänen J, Jämsä T, Tuukkanen J (2002) Effect of metal alloy surface stresses on the viability of ROS-17/2.8 osteoblastic cells. Biomaterials 23:3733-3740 (Pubitemid 34626574)
    • (2002) Biomaterials , vol.23 , Issue.17 , pp. 3733-3740
    • Kapanen, A.1    Danilov, A.2    Lehenkari, P.3    Ryhanen, J.4    Jamsa, T.5    Tuukkanen, J.6
  • 22
    • 0035990965 scopus 로고    scopus 로고
    • TGF-β1 secretion of ROS-17/2.8 cultures on NiTi implant material
    • DOI 10.1016/S0142-9612(02)00023-6, PII S0142961202000236
    • Kapanen A, Kinnunen A, Ryhänen J, Tuukkanen J (2002) TGF-beta1 secretion ofROS-17/2.8 cultures on NiTi implant material. Biomaterials 23:3341-3346 (Pubitemid 34615640)
    • (2002) Biomaterials , vol.23 , Issue.16 , pp. 3341-3346
    • Kapanen, A.1    Kinnunen, A.2    Ryhanen, J.3    Tuukkanen, J.4
  • 23
    • 66149139491 scopus 로고    scopus 로고
    • The study on biocompatibility of diamond-like carbon coated nickel- titanium shape memory alloy with osteoblasts cultured in vitro
    • Li Q, Zhang Q, Sun Z (2006) The study on biocompatibility of diamond-like carbon coated nickel- titanium shape memory alloy with osteoblasts cultured in vitro. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi 20:5-8
    • (2006) Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi , vol.20 , pp. 5-8
    • Li, Q.1    Zhang, Q.2    Sun, Z.3
  • 24
    • 0030617254 scopus 로고    scopus 로고
    • The response of primary rat and human osteoblasts and an immortalized rat osteoblast cell line to orthopaedic materials: Comparative sensitivity of several toxicity indices
    • DOI 10.1023/A:1018510900941
    • Macnair R, Rodgers EH, Macdonald C, Wykman A, Goldie I, Grant MH (1997) The response of primary rat and human osteoblasts and an immortalized rat osteoblast cell line to orthopaedic materials: comparative sensitivity of several toxicity indices. J Mater Sci Mater Med 8:105-111 (Pubitemid 27104284)
    • (1997) Journal of Materials Science: Materials in Medicine , vol.8 , Issue.2 , pp. 105-111
    • Macnair, R.1    Rodgers, E.H.2    Macdonald, C.3    Wykman, A.4    Goldie, I.5    Grant, M.H.6
  • 26
    • 0034110820 scopus 로고    scopus 로고
    • Application of stripping voltammetry and microelectrodes in vitro biocompatibility and in vivo toxicity tests of AISI 316L corrosion products
    • Morais S, Pereira MC (2000) Application of stripping voltammetry and microelectrodesin vitro biocompatibility and in vivo toxicity tests of AISI 316 L corrosion products. J Trace Elem Med Biol 14:48-54 (Pubitemid 30323946)
    • (2000) Journal of Trace Elements in Medicine and Biology , vol.14 , Issue.1 , pp. 48-54
    • Morais, S.1    Pereira, M.C.2
  • 27
    • 36249013606 scopus 로고    scopus 로고
    • Spark plasma sintering synthesis of porous nanocrystalline titanium alloys for biomedical applications
    • DOI 10.1016/j.bioeng.2007.08.008, PII S1389034407000974, Proceedings on Symposium J Surface Functionakization of Biomaterials
    • Nicula R, Lüthen F, Stir M, Nebe B, Burkel E (2007) Spark plasma sintering synthesis of porous nanocrystalline titanium alloys for biomedical applications. Biomol Eng 24:564-567 (Pubitemid 350123191)
    • (2007) Biomolecular Engineering , vol.24 , Issue.5 , pp. 564-567
    • Nicula, R.1    Luthen, F.2    Stir, M.3    Nebe, B.4    Burkel, E.5
  • 29
    • 0026607607 scopus 로고
    • Cemented versus cementless hiparthroplasty. A review of prosthetic biocompatibility
    • Santavirta S, Gristina A, Konttinen YT (1992) Cemented versus cementless hiparthroplasty. A review of prosthetic biocompatibility. Acta Orthop Scand 63:225-232
    • (1992) Acta Orthop Scand , vol.63 , pp. 225-232
    • Santavirta, S.1    Gristina, A.2    Konttinen, Y.T.3
  • 30
    • 70349250486 scopus 로고    scopus 로고
    • The positive influence of electrochemical cyclic potentiodynamic passivation (CPP) of a SS316LS surface on its response to fibronectin and preosteoblasts
    • Shahryari A, Azari F, Vali H, Omanovic S (2009) The positive influence of electrochemical cyclic potentiodynamic passivation (CPP) of a SS316LS surface on its response to fibronectin and preosteoblasts. Phys Chem Chem Phys 11:6218-6224
    • (2009) Phys Chem Chem Phys , vol.11 , pp. 6218-6224
    • Shahryari, A.1    Azari, F.2    Vali, H.3    Omanovic, S.4
  • 32
  • 33
    • 0030111456 scopus 로고    scopus 로고
    • Evaluation of the effect of three surface treatments on the biocompatibility of 316L stainless steel using human differentiated cells
    • DOI 10.1016/0142-9612(96)82723-2
    • Bordji K, Jouzeau JY, Mainard D, Payan E, Delagoutte JP, Netter P (1996) Evaluation of the effect of three surface treatments on the biocompatibility of 316L stainless steel using human differentiated cells. Biomaterials 17:491-500 (Pubitemid 26058532)
    • (1996) Biomaterials , vol.17 , Issue.5 , pp. 491-500
    • Bordji, K.1    Jouzeau, J.-Y.2    Mainard, D.3    Payan, E.4    Delagoutte, J.-P.5    Netter, P.6
  • 34
    • 2642582913 scopus 로고    scopus 로고
    • Biocompatibility of nickel-titanium shape memory metal and its corrosion behavior in human cell cultures
    • DOI 10.1002/(SICI)1097-4636(19970615)35:4<451::AID-JBM5>3.0.CO;2-G
    • Ryhänen J, Niemi E, Serlo W, Niemelä E, Sandvik P, Pernu H, Salo T (1997) Biocompatibility of nickel- titanium shape memory metal and its corrosion behavior in human cell cultures. J Biomed Mater Res 35:451-457 (Pubitemid 27250909)
    • (1997) Journal of Biomedical Materials Research , vol.35 , Issue.4 , pp. 451-457
    • Ryhanen, J.1    Niemi, E.2    Serlo, W.3    Niemela, E.4    Sandvik, P.5    Pernu, H.6    Salo, T.7
  • 35
    • 0035255416 scopus 로고    scopus 로고
    • Proliferation and differentiation parameters of human osteoblasts on titanium and steel surfaces
    • Schmidt C, Ignatius AA, Claes LE (2001) Proliferation and differentiation parameters of human osteoblasts on titanium and steel surfaces. J Biomed Mater Res 54:209-215
    • (2001) J Biomed Mater Res , vol.54 , pp. 209-215
    • Schmidt, C.1    Ignatius, A.A.2    Claes, L.E.3
  • 36
    • 0036968070 scopus 로고    scopus 로고
    • Easy assessment of the biocompatibility of Ni-Ti alloys by in vitro cell culture experiments on a functionally graded Ni-NiTi-Ti material
    • DOI 10.1016/S0142-9612(02)00200-4, PII S0142961202002004
    • Bogdanski D, Köller M, Müller D, Muhr G, Bram M, Buchkremer HP, Stöver D, Choi J, Epple M (2002) Easy assessment of the biocompatibility of Ni-Ti alloys by in vitro cell culture experiments on a functionally graded Ni-NiTi-Ti material. Biomaterials 23:4549-4555 (Pubitemid 36151606)
    • (2002) Biomaterials , vol.23 , Issue.23 , pp. 4549-4555
    • Bogdanski, D.1    Koller, M.2    Muller, D.3    Muhr, G.4    Bram, M.5    Buchkremer, H.P.6    Stover, D.7    Choi, J.8    Epple, M.9
  • 42
    • 0031812308 scopus 로고    scopus 로고
    • In vitro biomineralization by osteoblast-like cells I. Retardation of tissue mineralization by metal salts
    • DOI 10.1016/S0142-9612(97)00149-X, PII S014296129700149X
    • Morais S, Sousa JP, Fernandes MH, Carvalho GS (1998) In vitro biomineralization by osteoblast-like cells. I. Retardation of tissue mineralization by metal salts. Biomaterials 19:13-21 (Pubitemid 28239461)
    • (1998) Biomaterials , vol.19 , Issue.1-3 , pp. 13-21
    • Morais, S.1    Sousa, J.P.2    Fernandes, M.H.3    Carvalho, G.S.4
  • 43
    • 0036132469 scopus 로고    scopus 로고
    • Behaviour of Nitinol in osteoblast-like ROS-17 cell cultures
    • DOI 10.1016/S0142-9612(01)00143-0, PII S0142961201001430
    • Kapanen A, Ilvesaro J, Danilov A, Ryhänen J, Lehenkari P, Tuukkanen J (2002) Behaviour of Nitinol in osteoblast-like ROS-17 cell cultures. Biomaterials 23:645-650 (Pubitemid 33108940)
    • (2002) Biomaterials , vol.23 , Issue.3 , pp. 645-650
    • Kapanen, A.1    Ilvesaro, J.2    Danilov, A.3    Ryhanen, J.4    Lehenkari, P.5    Tuukkanen, J.6
  • 44
    • 12444336485 scopus 로고    scopus 로고
    • A new austenitic stainless steel with negligible nickel content: An in vitro and in vivo comparative investigation
    • DOI 10.1016/S0142-9612(03)00416-2
    • Fini M, Nicoli Aldini N, Torricelli P, Giavaresi G, Borsari V, Lenger H, Bernauer J, Giardino R, Chiesa R, Cigada A (2003) A new austenitic stainless steel with negligible nickel content: an in vitro and in vivo comparative investigation. Biomaterials 24:4929-4939 (Pubitemid 37237623)
    • (2003) Biomaterials , vol.24 , Issue.27 , pp. 4929-4939
    • Fini, M.1    Aldini, N.N.2    Torricelli, P.3    Giavaresi, G.4    Borsari, V.5    Lenger, H.6    Bernauer, J.7    Giardino, R.8    Chiesa, R.9    Cigada, A.10
  • 45
    • 4444312166 scopus 로고    scopus 로고
    • Metallic dental material biocompatibility in osteoblastlike cells: Correlation with metal ion release
    • DOI 10.1385/BTER:100:2:151
    • Cortizo MC, De Mele MF, Cortizo AM (2004) Metallic dental material biocompatibility in osteoblast like cells: correlation with metal ion release. Biol Trace Elem Res 100:151-168 (Pubitemid 39178912)
    • (2004) Biological Trace Element Research , vol.100 , Issue.2 , pp. 151-168
    • Cortizo, M.C.1    De Mele, M.F.L.2    Cortizo, A.M.3
  • 52
    • 48449101864 scopus 로고    scopus 로고
    • Osteoblast responses to different oxide coatings produced by the sol-gel process on titanium substrates
    • Ochsenbein A, Chai F, Winter S, Traisnel M, Breme J, Hildebrand HF (2008) Osteoblast responses to different oxide coatings produced by the sol-gel process on titanium substrates. Acta Biomater 4:1506-1517
    • (2008) Acta Biomater , vol.4 , pp. 1506-1517
    • Ochsenbein, A.1    Chai, F.2    Winter, S.3    Traisnel, M.4    Breme, J.5    Hildebrand, H.F.6
  • 54
    • 0029810742 scopus 로고    scopus 로고
    • Metal carcinogenesis in total joint arthroplasty. Animal models
    • Lewis CG, Sunderman FW (1996) Metal carcinogenesis in total joint arthroplasty. Animal models. Clin Orthop 329(suppl):264-268
    • (1996) Clin Orthop , vol.329 , Issue.SUPPL. , pp. 264-268
    • Lewis, C.G.1    Sunderman, F.W.2
  • 55
    • 0034732612 scopus 로고    scopus 로고
    • Inhibition of antimutagenic enzymes, 8-oxo-dGTPases, by carcinogenic metals. Recent developments
    • DOI 10.1016/S0162-0134(99)00240-8, PII S0162013499002408
    • Kasprzak KS, Bialkowski K (2000) Inhibition of antimutagenic enzymes, 8-oxo-dGTpases, by carcinogenic metals. J Inorg Biochem 79:231-236 (Pubitemid 30628736)
    • (2000) Journal of Inorganic Biochemistry , vol.79 , Issue.1-4 , pp. 231-236
    • Kasprzak, K.S.1    Bialkowski, K.2
  • 56
    • 0028248967 scopus 로고
    • Toxic effects caused by stainless steel corrosion products on mouse seminiferous cells
    • Pereira ML, Silva A, Tracana R, Carvalho GS (1994) Toxic effects caused by stainless steel corrosion products on mouse seminiferous cells. Cytobios 77:73-80
    • (1994) Cytobios , vol.77 , pp. 73-80
    • Pereira, M.L.1    Silva, A.2    Tracana, R.3    Carvalho, G.S.4
  • 58
    • 0029312264 scopus 로고
    • Allergic reaction to nickel orthodontic wire: A case report
    • Al-Waheidi EM (1995) Allergic reaction to nickel orthodontic wire: a case report. Quintessence Int 26:385-387
    • (1995) Quintessence Int , vol.26 , pp. 385-387
    • Al-Waheidi, E.M.1
  • 59
    • 0024654174 scopus 로고
    • Allergic reaction to orthodontic wire: Report of a case
    • Dunlap CL, Kirk Vincent S, Barker BF (1989) Allergic reaction to orthodontic wire: report of a case. J Am Dent Assoc 118:449-450
    • (1989) J Am Dent Assoc , vol.118 , pp. 449-450
    • Dunlap, C.L.1    Kirk Vincent, S.2    Barker, B.F.3
  • 60
    • 0027394047 scopus 로고
    • Nickel, cobalt and chromium m consumer products: A role in allergic contact dermatitis?
    • DOI 10.1111/j.1600-0536.1993.tb03318.x
    • Basketter DA, Briatico-Vangosa G, Kaestner W, Lally C, Bontinck WJ (1993) Nickel, cobalt and chromium in consumer products: a role in allergenic contact dermatitis? Contact Dermat 28:15-25 (Pubitemid 23012818)
    • (1993) Contact Dermatitis , vol.28 , Issue.1 , pp. 15-25
    • Basketter, D.A.1    Briatico-Vangosa, G.2    Kaestner, W.3    Lally, C.4    Bontinck, W.J.5
  • 62
    • 0021110612 scopus 로고
    • Contact dermatitis reaction to a metal buckle on a cervical headgear
    • Greig DGM (1983) Contact dermatitis reaction to a metal buckle on a cervical headgear. Br Dent J 155:61-62
    • (1983) Br Dent J , vol.155 , pp. 61-62
    • Dgm, G.1
  • 63
    • 0030816762 scopus 로고    scopus 로고
    • The carcinogenicity of metals in humans
    • DOI 10.1023/A:1018457305212
    • Hayes RB (1997) The carcinogenicity of metals in humans. Cancer Causes Control 8:371-385 (Pubitemid 27297804)
    • (1997) Cancer Causes and Control , vol.8 , Issue.3 , pp. 371-385
    • Hayes, R.B.1
  • 65
    • 0346433906 scopus 로고    scopus 로고
    • Experimental systemic contact dermatitis from nickel: A dose-response study
    • DOI 10.1111/j.0105-1873.2003.00157.x
    • Jensen CS, Menné T, Lisby S, Kristiansen J, Veien NK (2003) Experimental systemic contact dermatitis from nickel: a dose response study. Contact Dermat 49:124-132 (Pubitemid 38021662)
    • (2003) Contact Dermatitis , vol.49 , Issue.3 , pp. 124-132
    • Jensen, C.S.1    Menne, T.2    Lisby, S.3    Kristiansen, J.4    Veien, N.K.5
  • 68
    • 0031104796 scopus 로고    scopus 로고
    • Carcinogenicity assessment of selected nickel compounds
    • DOI 10.1006/taap.1996.8075
    • Oller AR, Costa M, Oberdorster G (1997) Carcinogenicity assessment of selected nickel compounds. Toxicol Appl Pharmacol 143:152-166 (Pubitemid 27130618)
    • (1997) Toxicology and Applied Pharmacology , vol.143 , Issue.1 , pp. 152-166
    • Oller, A.R.1    Costa, M.2    Oberdorster, G.3
  • 70
    • 33745713539 scopus 로고    scopus 로고
    • Nickel in dental plaque and saliva in patients with and without orthodontic appliances
    • DOI 10.1093/ejo/cji091
    • Fors R, Persson M (2006) Nickel in dental plaque and saliva in patients with and without orthodontic appliances. Eur J Orthod 28:292-297 (Pubitemid 43999445)
    • (2006) European Journal of Orthodontics , vol.28 , Issue.3 , pp. 292-297
    • Fors, R.1    Persson, M.2
  • 73
    • 33845958805 scopus 로고    scopus 로고
    • Decrease of trace elements in erythrocytes and plasma after removal of dental amalgam and other metal alloys
    • DOI 10.1385/BTER:113:3:247, PII BTER1133247
    • Frisk P, Lindvall A, Hudecek R, Lindh U (2006) Decrease of trace elements in erythrocytes and plasma after removal of dental amalgam and other metal alloys. Biol Trace Elem Res 113:247-259 (Pubitemid 46035380)
    • (2006) Biological Trace Element Research , vol.113 , Issue.3 , pp. 247-259
    • Frisk, P.1    Lindvall, A.2    Hudecek, R.3    Lindh, U.4
  • 74
    • 36048965156 scopus 로고    scopus 로고
    • Changed clinical chemistry pattern in blood after removal of dental amalgam and other metal alloys supported by antioxidant therapy
    • DOI 10.1007/s12011-007-8026-2
    • Frisk P, Danersund A, Hudecek R, Lindh U (2007) Changed clinical chemistry pattern in blood after removal of dental amalgam and other metal alloys supported by antioxidant therapy. Biol Trace Elem Res 120:163-170 (Pubitemid 350085221)
    • (2007) Biological Trace Element Research , vol.120 , Issue.1-3 , pp. 163-170
    • Frisk, P.1    Danersund, A.2    Hudecek, R.3    Lindh, U.4
  • 75
    • 48449087206 scopus 로고    scopus 로고
    • Study of salivary strontium and silver concentrations in primary school children related to dental caries
    • Shigemi T, Tanaka T, Hayashida Y, Maki K (2008) Study of salivary strontium and silver concentrations in primary school children related to dental caries. Biol Trace Elem Res 123:80-90
    • (2008) Biol Trace Elem Res , vol.123 , pp. 80-90
    • Shigemi, T.1    Tanaka, T.2    Hayashida, Y.3    Maki, K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.