1
-
-
0025860424
-
The first 24 hours after surgery. A study of complications after 2153 consecutive operations
-
Gamil M, Fanning A. The first 24 hours after surgery. A study of complications after 2153 consecutive operations. Anaesthesia 1991;46:712-5
-
(1991)
Anaesthesia
, vol.46
, pp. 712-715
-
-
Gamil, M.1
Fanning, A.2
-
2
-
-
0028297101
-
Respiratory depression associated with patient-controlled analgesia: A review of eight cases
-
Etches RC. Respiratory depression associated with patientcontrolled analgesia: review of eight cases. Can J Anaesth 1995;41:125-32 (Pubitemid 24075101)
-
(1994)
Canadian Journal of Anaesthesia
, vol.41
, Issue.2
, pp. 125-132
-
-
Etches, R.C.1
-
3
-
-
26844451842
-
Postoperative day one: A high risk period for respiratory events
-
DOI 10.1016/j.amjsurg.2005.07.015, PII S0002961005006434
-
Taylor S, Kirton OC, Staff I, Kozol RA. Postoperative day one: a high risk period for respiratory events. Am J Surg 2005;190:752-6 (Pubitemid 41446500)
-
(2005)
American Journal of Surgery
, vol.190
, Issue.5
, pp. 752-756
-
-
Taylor, S.1
Kirton, O.C.2
Staff, I.3
Kozol, R.A.4
-
4
-
-
0034898650
-
Efficacy and safety of patient-controlled opioid analgesia for acute postoperative pain
-
DOI 10.1034/j.1399-6576.2001.045007795.x
-
Walder B, Schafer M, Henzi I, Tramer MR. Efficacy and safety of patient-controlled opioid analgesia for acute postoperative pain-a quantitative systematic review. Acta Anaesthesiol Scand 2001;45:795-804 (Pubitemid 32738444)
-
(2001)
Acta Anaesthesiologica Scandinavica
, vol.45
, Issue.7
, pp. 795-804
-
-
Walder, B.1
Schafer, M.2
Henzi, I.3
Tramer, M.R.4
-
5
-
-
22944460189
-
The efficacy and safety of pain management before and after implementation of hospital-wide pain management standards: Is patient safety compromised by treatment based solely on numerical pain ratings?
-
DOI 10.1213/01.ANE.0000155970.45321.A8
-
Vila H Jr, Smith RA, Augustyniak MJ, et al. The efficacy and safety of pain management before and after implementation of hospital-wide pain management standards: is patient safety compromised by treatment based solely on numerical pain ratings? Anesth Analg 2005;101:474-80 (Pubitemid 41045233)
-
(2005)
Anesthesia and Analgesia
, vol.101
, Issue.2
, pp. 474-480
-
-
Vila Jr., H.1
Smith, R.A.2
Augustyniak, M.J.3
Nagi, P.A.4
Soto, R.G.5
Ross, T.W.6
Cantor, A.B.7
Strickland, J.M.8
Miguel, R.V.9
-
6
-
-
80051763006
-
Safer pain management
-
Available from www.dh.gov. uk/cmo last accessed March 2011
-
Ellis B. Safer pain management. CMO Update 2009;49:5. Available from www.dh.gov. uk/cmo (last accessed March 2011)
-
(2009)
CMO Update
, vol.49
, pp. 5
-
-
Ellis, B.1
-
7
-
-
0024517142
-
Respiratory rates in emergency department patients
-
DOI 10.1016/0736-4679(89)90257-6
-
Hooker EA, O'Brien DJ, Danzl DF, Barefoot JA, Brown JE. Respiratory rates in emergency department patients. J Emerg Med 1989;7:129-32 (Pubitemid 19120305)
-
(1989)
Journal of Emergency Medicine
, vol.7
, Issue.2
, pp. 129-132
-
-
Hooker, E.A.1
O'Brien, D.J.2
Danzi, D.F.3
Barefoot, J.A.C.4
Brown, J.E.5
-
8
-
-
11144238311
-
The vexatious vital: Neither clinical measurements by nurses nor an electronic monitor provides accurate measurements of respiratory rate in triage
-
DOI 10.1016/j.annemergmed.2004.06.016, PII S0196064404006493
-
Lovett PB, Buchwald JM, Sturmann K, Bijur P. The vexatious vital: neither clinical measurements by nurses nor an electronic monitor provides accurate measurements of respiratory rate in triage. Ann Emerg Med 2005;45:68-76 (Pubitemid 40051170)
-
(2005)
Annals of Emergency Medicine
, vol.45
, Issue.1
, pp. 68-76
-
-
Lovett, P.B.1
Buchwald, J.M.2
Sturmann, K.3
Bijur, P.4
-
9
-
-
34547604102
-
Continuous oximetry/capnometry monitoring reveals frequent desaturation and bradypnea during patient-controlled analgesia
-
DOI 10.1213/01.ane.0000269489.26048.63, PII 0000053920070800000023
-
Overdyk FJ, Carter R, Maddox RR, Callura J, Herrin AE, Henriquez C. Continuous oximetry/capnometry monitoring reveals frequent desaturation and bradypnea during patient-controlled analgesia. Anesth Analg 2007;105:412-8 (Pubitemid 47196421)
-
(2007)
Anesthesia and Analgesia
, vol.105
, Issue.2
, pp. 412-418
-
-
Overdyk, F.J.1
Carter, R.2
Maddox, R.R.3
Callura, J.4
Herrin, A.E.5
Henriquez, C.6
-
10
-
-
77449123270
-
Impact of pulse oximetry surveillance on rescue events and intensive care unit transfers: A before-and-after concurrence study
-
Taenzer AH, Pyke JB, McGrath SP, Blike GT. Impact of pulse oximetry surveillance on rescue events and intensive care unit transfers: a before-and-after concurrence study. Anesthesiology 2010;112:282-7
-
(2010)
Anesthesiology
, vol.112
, pp. 282-287
-
-
Taenzer, A.H.1
Pyke, J.B.2
McGrath, S.P.3
Blike, G.T.4
-
11
-
-
44949133927
-
Mortality and utilisation of critical care resources amongst high-risk surgical patients in a large NHS trust
-
DOI 10.1111/j.1365-2044.2008.05560.x
-
Jhanji S, Thomas B, Ely A, Watson D, Hinds CJ, Pearse RM. Mortality and utilisation of critical care resources amongst high-risk surgical patients in a large NHS trust. Anaesthesia 2008;63:695-700 (Pubitemid 351814238)
-
(2008)
Anaesthesia
, vol.63
, Issue.7
, pp. 695-700
-
-
Jhanji, S.1
Thomas, B.2
Ely, A.3
Watson, D.4
Hinds, C.J.5
Pearse, R.M.6
-
12
-
-
34447630814
-
Identification and characterisation of the high-risk surgical population in the United Kingdom
-
Pearse RM, Harrison DA, James P, et al. Identification and characterisation of the high-risk surgical population in the United Kingdom. Crit Care 2006;10:R81
-
(2006)
Crit Care
, vol.10
-
-
Pearse, R.M.1
Harrison, D.A.2
James, P.3
-
13
-
-
0028337587
-
Postanesthesia monitoring revisited: Frequency of true and false alarms from different monitoring devices
-
DOI 10.1016/0952-8180(94)90056-6
-
Wiklund L, Hok B, Ståhl K, Jordeby-Jönsson A. Postanesthesia monitoring revisited-frequency of true and false alarms from different monitoring devices. J Clin Anesth 1994;6:182-8 (Pubitemid 24174571)
-
(1994)
Journal of Clinical Anesthesia
, vol.6
, Issue.3
, pp. 182-188
-
-
Wiklund, L.1
Hok, B.2
Stahl, K.3
Jordeby-Jonsson, A.4
-
14
-
-
77955188413
-
Respiratory rate and flow waveform estimation from tri-axial accelerometer data, body sensor networks (BSN)
-
Bates A, Ling MJ, Mann J, Arvind DK. Respiratory rate and flow waveform estimation from tri-axial accelerometer data, Body Sensor Networks (BSN), 2010 International Conference, 2010;144-50
-
(2010)
2010 International Conference
, pp. 144-150
-
-
Bates, A.1
Ling, M.J.2
Mann, J.3
Arvind, D.K.4
-
15
-
-
0036682889
-
Validation of nasal pressure for the identification of apneas/hypopneas during sleep
-
Heitman S, Atkar R, Hajduk E, Wanner R, Flemons W. Validation of nasal pressure for the identification of apneas/hypopneas during sleep. Am J Respir Crit Care Med 2002;166:386
-
(2002)
Am J Respir Crit Care Med
, vol.166
, pp. 386
-
-
Heitman, S.1
Atkar, R.2
Hajduk, E.3
Wanner, R.4
Flemons, W.5
-
16
-
-
0020694770
-
Effect of breathing route on ventilation and ventilatory drive
-
DOI 10.1016/0034-5687(83)90041-5
-
Douglas NJ, White DP, Weil JV, Zwillich CW. Effect of breathing route on ventilation and ventilatory drive. Respir Physiol 1983;51:209-18 (Pubitemid 13152947)
-
(1983)
Respiration Physiology
, vol.51
, Issue.2
, pp. 209-218
-
-
Douglas, N.J.1
White, D.P.2
Weil, J.V.3
Zwillich, C.W.4
-
17
-
-
0029760335
-
Respiratory mechanics after abdominal surgery measured with continuous analysis of pressure, flow and volume signals
-
Nimmo AF, Drummond GB. Respiratory mechanics after abdominal surgery measured with continuous analysis of pressure, flow and volume signals. Br J Anaesth 1996;77:317-26 (Pubitemid 26300854)
-
(1996)
British Journal of Anaesthesia
, vol.77
, Issue.3
, pp. 317-326
-
-
Nimmo, A.F.1
Drummond, G.B.2
-
18
-
-
0345714938
-
Sleep arousal after lower abdominal surgery and relation to recovery from respiratory obstruction
-
DOI 10.1097/00000542-200312000-00010
-
Wu AH, Drummond GB. Sleep arousal after lower abdominal surgery and relation to recovery from respiratory obstruction. Anesthesiology 2003;99:1295-302 (Pubitemid 37475173)
-
(2003)
Anesthesiology
, vol.99
, Issue.6
, pp. 1295-1302
-
-
Wu, A.1
Drummond, G.B.2
-
19
-
-
0034879264
-
Association of airway obstruction, sleep, and phasic abdominal muscle activity after upper abdominal surgery
-
DOI 10.1093/bja/87.2.198
-
Rahman MQ, Kingshott RN, Wraith P, Adams WH, Drummond GB. Association of airway obstruction, sleep, and phasic abdominal muscle activity after upper abdominal surgery. Br J Anaesth 2001;87:198-203 (Pubitemid 32750526)
-
(2001)
British Journal of Anaesthesia
, vol.87
, Issue.2
, pp. 198-203
-
-
Rahman, M.Q.1
Kingshott, R.N.2
Wraith, P.3
Adams, W.H.4
Drummond, G.B.5
-
22
-
-
0141997171
-
Assessment of thoracoabdominal bands to detect respiratory effort-related arousal
-
Masa JF, Corral J, Martin MJ, et al. Assessment of thoracoabdominal bands to detect respiratory effort-related arousal. Eur Respir J 2003;22:661-7 (Pubitemid 37258547)
-
(2003)
European Respiratory Journal
, vol.22
, Issue.4
, pp. 661-667
-
-
Masa, J.F.1
Corral, J.2
Martin, M.J.3
Riesco, J.A.4
Sojo, A.5
Hernandez, M.6
Douglas, N.J.7
-
23
-
-
0036204325
-
Automatic CPAP compared with conventional treatment for episodic hypoxemia and sleep disturbance after major abdominal surgery
-
DOI 10.1097/00000542-200204000-00007
-
Drummond GB, Stedul K, Kingshott R, et al. Automatic CPAP compared with conventional treatment for episodic hypoxemia and sleep disturbance after major abdominal surgery. Anesthesiology 2002;96:817-26 (Pubitemid 34266673)
-
(2002)
Anesthesiology
, vol.96
, Issue.4
, pp. 817-826
-
-
Drummond, G.B.1
Stedul, K.2
Kingshott, R.3
Rees, K.4
Nimmo, A.F.5
Wraith, P.6
Douglas, N.J.7
-
24
-
-
0035689153
-
The clinical evaluation of the Respi-check mask: A new oxygen mask incorporating a breathing indicator
-
Breakell A, Townsend-Rose C. The clinical evaluation of the Respicheck mask: a new oxygen mask incorporating a breathing indicator. Emerg Med J 2001;18:366-9 (Pubitemid 34070966)
-
(2001)
Emergency Medicine Journal
, vol.18
, Issue.5
, pp. 366-369
-
-
Breakell, A.1
Townsend-Rose, C.2
-
25
-
-
0023036770
-
Continuous noninvasive monitoring of respiratory rate in critically ill patients
-
Krieger B, Feinerman D, Zaron A, Bizousky F. Continuous noninvasive monitoring of respiratory rate in critically ill patients. Chest 1986;90:632-4 (Pubitemid 17181626)
-
(1986)
Chest
, vol.90
, Issue.5
, pp. 632-634
-
-
Krieger, B.1
Feinerman, D.2
Zaron, A.3
Bizousky, F.4
-
26
-
-
0015948651
-
Alterations in ventilatory function and breathing patterns following surgical trauma
-
Zikria BA, Spencer JL, Kinney JM, Broell JR. Alterations in ventilatory function and breathing patterns following surgical trauma. Ann Surg 1974;179:1-7
-
(1974)
Ann Surg
, vol.179
, pp. 1-7
-
-
Zikria, B.A.1
Spencer, J.L.2
Kinney, J.M.3
Broell, J.R.4
-
27
-
-
0029966299
-
Respiratory depression: An adverse outcome during patient controlled analgesia therapy
-
DOI 10.1016/0952-8180(95)00202-2
-
Looi-Lyons LC, Chung FF, Chan VW, McQuestion M. Respiratory depression: an adverse outcome during patient controlled analgesia therapy. J Clin Anesth 1996;8:151-6 (Pubitemid 26073981)
-
(1996)
Journal of Clinical Anesthesia
, vol.8
, Issue.2
, pp. 151-156
-
-
Looi-Lyons, L.C.1
Chung, F.F.2
Chan, V.W.3
McQuestion, M.4
-
28
-
-
0035653520
-
Vital signs in hospital patients: A systematic review
-
DOI 10.1016/S0020-7489(00)00119-X, PII S002074890000119X
-
Evans D, Hodgkinson B, Berry J. Vital signs in hospital patients: a systematic review. Int J Nurs Stud 2001;38:643-50 (Pubitemid 33649447)
-
(2001)
International Journal of Nursing Studies
, vol.38
, Issue.6
, pp. 643-650
-
-
Evans, D.1
Hodgkinson, B.2
Berry, J.3
-
29
-
-
1842688144
-
Prospective controlled trial of effect of medical emergency team on postoperative morbidity and mortality rates
-
DOI 10.1097/01.CCM.0000119428.02968.9E
-
Bellomo R, Goldsmith D, Uchino S, et al. Prospective controlled trial of effect of medical emergency team on postoperative morbidity and mortality rates. Crit Care Med 2004;32:916-21 (Pubitemid 38471509)
-
(2004)
Critical Care Medicine
, vol.32
, Issue.4
, pp. 916-921
-
-
Bellomo, R.1
Goldsmith, D.2
Uchino, S.3
Buckmaster, J.4
Hart, G.5
Opdam, H.6
Silvester, W.7
Doolan, L.8
Gutteridge, G.9
-
30
-
-
74549193424
-
A weak link in the rapid response system
-
Edelson DP. A weak link in the rapid response system. Arch Intern Med 2010;170:12-3
-
(2010)
Arch Intern Med
, vol.170
, pp. 12-13
-
-
Edelson, D.P.1
|