메뉴 건너뛰기




Volumn 34, Issue 2, 2011, Pages 273-279

Monte Carlo study of the energy response and depth dose water equivalence of the MOSkin radiation dosimeter at clinical kilovoltage photon energies

Author keywords

Geant4; Kilovoltage energy; Monte Carlo; MOSFET; Radiation protection

Indexed keywords

AUSTRALIA; CORRECTION FACTORS; DEPTH DOSE; ENERGY RESPONSE; ENHANCEMENT EFFECTS; GEANT4; GEANT4 TOOLKITS; KILOVOLTAGE ENERGY; MONTE CARLO; MONTE CARLO SIMULATION; MONTE CARLO STUDY; MOS-FET; PACKAGING DESIGNS; PHOTON ENERGY; PHOTON SOURCES; QUANTITY OF INTEREST; RADIATION DOSIMETERS; RADIATION PHYSICS; RADIATION SENSORS; RADIOLOGICAL PROTECTION; SHALLOW DEPTHS; SKIN DOSE; SURFACE ENERGIES; THIN METALLIC FOILS; WATER EQUIVALENCE; WATER EQUIVALENT; WATER PHANTOM; X RAY IRRADIATION; X-RAY CT;

EID: 80051705203     PISSN: 01589938     EISSN: None     Source Type: Journal    
DOI: 10.1007/s13246-011-0075-3     Document Type: Article
Times cited : (9)

References (19)
  • 2
    • 58149115070 scopus 로고    scopus 로고
    • The effect of rectal heterogeneity on wall dose in high dose rate brachytherapy
    • 19235390 10.1118/1.3031111 1:STN:280:DC%2BD1M7mtVKjug%3D%3D
    • IS Kwan D Wilkinson D Cutajar M Lerch A Rosenfeld A Howie J Bucci Y Chin VL Perevertaylo 2009 The effect of rectal heterogeneity on wall dose in high dose rate brachytherapy Med Phys 36 1 224 232 19235390 10.1118/1.3031111 1:STN:280:DC%2BD1M7mtVKjug%3D%3D
    • (2009) Med Phys , vol.36 , Issue.1 , pp. 224-232
    • Kwan, I.S.1    Wilkinson, D.2    Cutajar, D.3    Lerch, M.4    Rosenfeld, A.5    Howie, A.6    Bucci, J.7    Chin, Y.8    Perevertaylo, V.L.9
  • 3
    • 54949142565 scopus 로고    scopus 로고
    • Dosimetric verification of helical tomotherapy for total scalp irradiation
    • 19070240 10.1118/1.2996288
    • N Hardcastle E Soisson P Metcalfe A Rosenfeld W Tome 2008 Dosimetric verification of helical tomotherapy for total scalp irradiation Med Phys 35 11 5061 5068 19070240 10.1118/1.2996288
    • (2008) Med Phys , vol.35 , Issue.11 , pp. 5061-5068
    • Hardcastle, N.1    Soisson, E.2    Metcalfe, P.3    Rosenfeld, A.4    Tome, W.5
  • 4
    • 58149134060 scopus 로고    scopus 로고
    • In vivo verification of superficial dose for head and neck treatments using intensity-modulated techniques
    • 19235374 10.1118/1.3030951
    • Z Qi X Deng S Huang L Zhang Z He A Li I Kwan M Lerch D Cutajar P Metcalfe A Rosenfeld 2009 In vivo verification of superficial dose for head and neck treatments using intensity-modulated techniques Med Phys 36 1 59 70 19235374 10.1118/1.3030951
    • (2009) Med Phys , vol.36 , Issue.1 , pp. 59-70
    • Qi, Z.1    Deng, X.2    Huang, S.3    Zhang, L.4    He, Z.5    Li, A.6    Kwan, I.7    Lerch, M.8    Cutajar, D.9    Metcalfe, P.10    Rosenfeld, A.11
  • 5
    • 0029251828 scopus 로고
    • Effects of package geometry, materials, and die design on energy dependence of pMOS dosimeters
    • 10.1109/23.364879 1:CAS:528:DyaK2MXkslCrtLY%3D
    • GJ Brucker S Kronenberg F Gentner 1995 Effects of package geometry, materials, and die design on energy dependence of pMOS dosimeters IEEE Trans Nucl Sci 42 1 33 40 10.1109/23.364879 1:CAS:528:DyaK2MXkslCrtLY%3D
    • (1995) IEEE Trans Nucl Sci , vol.42 , Issue.1 , pp. 33-40
    • Brucker, G.J.1    Kronenberg, S.2    Gentner, F.3
  • 6
    • 17844399597 scopus 로고    scopus 로고
    • Monte Carlo study of MOSFET dosemeter characteristics: Dose dependence on photon energy, direction and dosemeter composition
    • DOI 10.1093/rpd/nch426
    • B Wang XG Xu CH Kim 2005 Monte Carlo study of MOSFET dosemeter characteristics: dose dependence on photon energy, direction and dosemeter composition Radiat Prot Dosim 113 1 40 46 10.1093/rpd/nch426 1:CAS:528:DC%2BD2MXktlOrsbk%3D (Pubitemid 40584834)
    • (2005) Radiation Protection Dosimetry , vol.113 , Issue.1 , pp. 40-46
    • Wang, B.1    Xu, X.G.2    Kim, C.-H.3
  • 7
    • 2442646488 scopus 로고    scopus 로고
    • Monte Carlo modeling of a High-Sensitivity MOSFET dosimeter for low- and medium-energy photon sources
    • DOI 10.1118/1.1688272
    • B Wang CH Kim XG Xu 2004 Monte Carlo modeling of a high-sensitivity MOSFET dosimeter for low- and medium-energy photon sources Med Phys 31 5 1003 1008 15191284 10.1118/1.1688272 1:CAS:528:DC%2BD2cXjslKmtLo%3D (Pubitemid 38656767)
    • (2004) Medical Physics , vol.31 , Issue.5 , pp. 1003-1008
    • Wang, B.1    Kim, C.-H.2    Xu, X.G.3
  • 8
    • 0029518433 scopus 로고
    • MOSFET dosimeters: The role of encapsulation on dosimetric characteristics in mixed gamma-neutron and megavoltage X-ray fields
    • 10.1109/23.489229 1:CAS:528:DyaK28Xpt12ltA%3D%3D
    • AB Rosenfeld MG Carolan GI Kaplan JB Allen VI Khivrich 1995 MOSFET dosimeters: the role of encapsulation on dosimetric characteristics in mixed gamma-neutron and megavoltage X-ray fields IEEE Trans Nucl Sci 42 6 1870 1877 10.1109/23.489229 1:CAS:528:DyaK28Xpt12ltA%3D%3D
    • (1995) IEEE Trans Nucl Sci , vol.42 , Issue.6 , pp. 1870-1877
    • Rosenfeld, A.B.1    Carolan, M.G.2    Kaplan, G.I.3    Allen, J.B.4    Khivrich, V.I.5
  • 11
    • 0022083110 scopus 로고
    • Ein Programm fur die Berechnung von diagnostischen Roentgenspektren
    • 10.1055/s-2008-1052738 1:STN:280:DyaL2M3hslKntg%3D%3D
    • R Nowotny A Hvfer 1985 Ein Programm fur die Berechnung von diagnostischen Roentgenspektren Fortschr Roentgenstr 142 685 689 10.1055/s-2008-1052738 1:STN:280:DyaL2M3hslKntg%3D%3D
    • (1985) Fortschr Roentgenstr , vol.142 , pp. 685-689
    • Nowotny, R.1    Hvfer, A.2
  • 12
    • 71049117748 scopus 로고    scopus 로고
    • SpekCalc: A program to calculate photon spectra from tungsten anode X-ray tubes
    • 19724100 10.1088/0031-9155/54/19/N01 1:STN:280:DC%2BD1MnktVKnsA%3D%3D
    • G Poludniowski G Landry F DeBlois P Evans F Verhaegen 2009 SpekCalc: a program to calculate photon spectra from tungsten anode X-ray tubes Phys Med Biol 54 19 N433 N438 19724100 10.1088/0031-9155/54/19/N01 1:STN:280: DC%2BD1MnktVKnsA%3D%3D
    • (2009) Phys Med Biol , vol.54 , Issue.19
    • Poludniowski, G.1    Landry, G.2    Deblois, F.3    Evans, P.4    Verhaegen, F.5
  • 16
    • 4444380606 scopus 로고    scopus 로고
    • The skin is radiological protection - Recent advances and residual unresolved issues
    • DOI 10.1093/rpd/nch309
    • M Charles 2004 The skin in radiological protection: recent advances and residual unresolved issues Radiat Prot Dosim 109 4 323 330 10.1093/rpd/nch309 1:CAS:528:DC%2BD2cXnslyitLg%3D (Pubitemid 39162562)
    • (2004) Radiation Protection Dosimetry , vol.109 , Issue.4 , pp. 323-330
    • Charles, M.W.1
  • 17
    • 0022548439 scopus 로고
    • Problems related to the critical depth of skin
    • W Roesch 1986 Problems related to the critical depth of skin Radiat Prot Dosim 14 2 91 93 (Pubitemid 16083343)
    • (1986) Radiation Protection Dosimetry , vol.14 , Issue.2 , pp. 91-93
    • Roesch, W.C.1
  • 18
    • 80051698205 scopus 로고
    • The biological basis for dose limitation in the skin (ICRP Publication 59)
    • International Commission on Radiological Protection. Pergamon Press, Oxford
    • International Commission on Radiological Protection (1991) The biological basis for dose limitation in the skin (ICRP Publication 59). Ann ICRP, vol 22 (2), Pergamon Press, Oxford
    • (1991) Ann ICRP , vol.22 , Issue.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.