메뉴 건너뛰기




Volumn 34, Issue 8, 2011, Pages 968-974

Intrathoracic impedance and ultrasound lung comets in heart failure deterioration monitoring

Author keywords

echography; Heart failure; implantable defibrillator; intrathoracic impedance; ultrasound lung comets

Indexed keywords

AGED; ALGORITHM; ARTICLE; CLINICAL ARTICLE; CLINICAL EVALUATION; DEVICE; DISEASE COURSE; DOPPLER ECHOCARDIOGRAPHY; FEMALE; FOLLOW UP; HEART FAILURE; HUMAN; IMPEDANCE; LUNG ALVEOLUS; LUNG ALVEOLUS SURFACE TENSION; LUNG EDEMA; LUNG FLUID; MALE; PATIENT MONITORING; PREDICTIVE VALUE; PULMONARY ARTERY OCCLUSION PRESSURE; SENSITIVITY ANALYSIS; ULTRASOUND;

EID: 80051684290     PISSN: 01478389     EISSN: 15408159     Source Type: Journal    
DOI: 10.1111/j.1540-8159.2011.03072.x     Document Type: Article
Times cited : (16)

References (19)
  • 2
    • 19844374972 scopus 로고    scopus 로고
    • 'Ultrasound comet-tail images': A marker of pulmonary edema - A comparative study with wedge pressure and extravascular lung water
    • DOI 10.1378/chest.127.5.1690
    • Agricola E, Bove T, Oppizzi M, Marino G, Zangrillo A, Margonato A, Picano E,. "Ultrasound comet-tail images": A marker of pulmonary edema: A comparative study with wedge pressure and extravascular lung water. Chest 2005; 127: 1690-1695. (Pubitemid 46218796)
    • (2005) Chest , vol.127 , Issue.5 , pp. 1690-1695
    • Agricola, E.1    Bove, T.2    Oppizzi, M.3    Marino, G.4    Zangrillo, A.5    Margonato, A.6    Picano, E.7
  • 3
    • 23844525145 scopus 로고    scopus 로고
    • Intrathoracic impedance monitoring in patients with heart failure: Correlation with fluid status and feasibility of early warning preceding hospitalization
    • DOI 10.1161/CIRCULATIONAHA.104.492207
    • Yu CM, Wang L, Chau E, Chan RH, Kong SL, Tang MO, Christensen J, et al,. Intrathoracic impedance monitoring in patients with heart failure: Correlation with fluid status and feasibility of early warning preceding hospitalization. Circulation 2005; 112: 841-848. (Pubitemid 41170070)
    • (2005) Circulation , vol.112 , Issue.6 , pp. 841-848
    • Yu, C.-M.1    Wang, L.2    Chau, E.3    Chan, R.H.-W.4    Kong, S.-L.5    Tang, M.-O.6    Christensen, J.7    Stadler, R.W.8    Lau, C.-P.9
  • 4
    • 34248572239 scopus 로고    scopus 로고
    • Fundamentals of intrathoracic impedance monitoring in heart failure
    • Wang L,. Fundamentals of intrathoracic impedance monitoring in heart failure. Am J Cardiol 2007; 99: 3G-10G.
    • (2007) Am J Cardiol , vol.99
    • Wang, L.1
  • 5
    • 34547755068 scopus 로고    scopus 로고
    • Clinical utility of intrathoracic impedance monitoring to alert patients with an implanted device of deteriorating chronic heart failure
    • DOI 10.1093/eurheartj/ehl506
    • Vollmann D, Nagele H, Schauerte P, Wiegand U, Butter C, Zanotto G, Quesada A, et al,. European InSync Sentry Observational Study Investigators. Clinical utility of intrathoracic impedance monitoring to alert patients with an implanted device of deteriorating chronic heart failure. Eur Heart J 2007; 28: 1835-1840. (Pubitemid 47236638)
    • (2007) European Heart Journal , vol.28 , Issue.15 , pp. 1835-1840
    • Vollmann, D.1    Nagele, H.2    Schauerte, P.3    Wiegand, U.4    Butter, C.5    Zanotto, G.6    Quesada, A.7    Guthmann, A.8    Hill, M.R.S.9    Lamp, B.10
  • 6
    • 56549084950 scopus 로고    scopus 로고
    • Optivol-CRT Clinical Service Observational Group. Implantable CRT device diagnostics identify patients with increased risk for heart failure hospitalization
    • Perego GB, Landolina M, Vergara G, Lunati M, Zanotto G, Pappone A, Lonardi G, et al,. Optivol-CRT Clinical Service Observational Group. Implantable CRT device diagnostics identify patients with increased risk for heart failure hospitalization. J Interv Card Electrophysiol 2008; 23: 235-242.
    • (2008) J Interv Card Electrophysiol , vol.23 , pp. 235-242
    • Perego, G.B.1    Landolina, M.2    Vergara, G.3    Lunati, M.4    Zanotto, G.5    Pappone, A.6    Lonardi, G.7
  • 7
    • 35348854915 scopus 로고    scopus 로고
    • Usefulness of intrathoracic fluids accumulation monitoring with an implantable biventricular defibrillator in reducing hospitalizations in patients with heart failure: A case-control study
    • DOI 10.1007/s10840-007-9155-4
    • Maines M, Catanzariti D, Cemin C, Vaccarini C, Vergara G,. Usefulness of intrathoracic fluids accumulation monitoring with an implantable biventricular defibrillator in reducing hospitalizations in patients with heart failure: A case-control study. J Interv Card Electrophysiol 2007; 19: 201-207. (Pubitemid 47573216)
    • (2007) Journal of Interventional Cardiac Electrophysiology , vol.19 , Issue.3 , pp. 201-207
    • Maines, M.1    Catanzariti, D.2    Cemin, C.3    Vaccarini, C.4    Vergara, G.5
  • 8
    • 61449196873 scopus 로고    scopus 로고
    • On behalf of the Italian Clinical Service Optivol-CRT Group. Monitoring intrathoracic impedance with an implantable defibrillator reduces hospitalizations in patients with heart failure
    • Catanzariti D, Lunati M, Landolina M, Zanotto G, Lonardi G, Iacopino S, Oliva F, et al,. On behalf of the Italian Clinical Service Optivol-CRT Group. Monitoring intrathoracic impedance with an implantable defibrillator reduces hospitalizations in patients with heart failure. Pacing Clin Electrophysiol 2009; 32: 363-370.
    • (2009) Pacing Clin Electrophysiol , vol.32 , pp. 363-370
    • Catanzariti, D.1    Lunati, M.2    Landolina, M.3    Zanotto, G.4    Lonardi, G.5    Iacopino, S.6    Oliva, F.7
  • 9
    • 28744446343 scopus 로고    scopus 로고
    • ACC/AHA 2005 Guideline Update for the diagnosis and management of chronic heart failure in the adult: A report of the American College of Cardiology
    • American Heart Association Task Force on Practice Guidelines (Writing Committee to Update the 2001 Guidelines for the Evaluation and Management of Heart Failure): Developed in collaboration with the American College of Chest Physicians and the International Society for Heart and Lung Transplantation: Endorsed by the Heart Rhythm Society American College of Cardiology; American Heart Association Task Force on Practice Guidelines; American College of Chest Physicians; International Society for Heart and Lung Transplantation; Heart Rhythm Society
    • Hunt SA, Abraham WT, Chin MH, Feldman AM, Francis GS, Ganiats TG, Jessup M, et al,. American College of Cardiology; American Heart Association Task Force on Practice Guidelines; American College of Chest Physicians; International Society for Heart and Lung Transplantation; Heart Rhythm Society. ACC/AHA 2005 Guideline Update for the diagnosis and management of chronic heart failure in the adult: A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Update the 2001 Guidelines for the Evaluation and Management of Heart Failure): Developed in collaboration with the American College of Chest Physicians and the International Society for Heart and Lung Transplantation: Endorsed by the Heart Rhythm Society. Circulation 2005; 112: e154-e235.
    • (2005) Circulation , vol.112
    • Hunt, S.A.1    Abraham, W.T.2    Chin, M.H.3    Feldman, A.M.4    Francis, G.S.5    Ganiats, T.G.6    Jessup, M.7
  • 11
    • 2342536902 scopus 로고    scopus 로고
    • Usefulness of ultrasound lung comets as a nonradiologic sign of extravascular lung water
    • DOI 10.1016/j.amjcard.2004.02.012, PII S0002914904002279
    • Jambrik Z, Monti S, Coppola V, Agricola E, Mottola G, Miniati M, Picano E,. Usefulness of ultrasound lung comets as a nonradiologic sign of extravascular lung water. Am J Cardiol 2004; 93: 1265-1270. (Pubitemid 38595681)
    • (2004) American Journal of Cardiology , vol.93 , Issue.10 , pp. 1265-1270
    • Jambrik, Z.1    Monti, S.2    Coppola, V.3    Agricola, E.4    Mottola, G.5    Miniati, M.6    Picano, E.7
  • 12
    • 0029919485 scopus 로고    scopus 로고
    • Doppler echocardiography reliably predicts pulmonary artery wedge pressure in patients with chronic heart failure with and without mitral regurgitation
    • DOI 10.1016/0735-1097(95)00553-6
    • Pozzoli M, Capomolla S, Pinna G, Cobelli F, Tavazzi L,. Doppler echocardiography reliably predicts pulmonary artery wedge pressure in patients with chronic heart failure with and without mitral regurgitation. J Am Coll Cardiol 1996; 27: 883-893. (Pubitemid 26104870)
    • (1996) Journal of the American College of Cardiology , vol.27 , Issue.4 , pp. 883-893
    • Pozzoli, M.1    Capomolla, S.2    Pinna, G.3    Cobelli, F.4    Tavazzi, L.5
  • 13
    • 0035100681 scopus 로고    scopus 로고
    • Doppler echocardiography reliably predicts pulmonary artery wedge pressure in patients with chronic heart failure even when atrial fibrillation is present
    • DOI 10.1016/S1388-9842(00)00140-9, PII S1388984200001409
    • Traversi E, Cobelli F, Pozzoli M,. Doppler echocardiography reliably predicts pulmonary artery wedge pressure in patients with chronic heart failure even when atrial fibrillation is present. Eur J Heart Fail 2001; 3: 173-181. (Pubitemid 32216657)
    • (2001) European Journal of Heart Failure , vol.3 , Issue.2 , pp. 173-181
    • Traversi, E.1    Cobelli, F.2    Pozzoli, M.3
  • 15
    • 0023681461 scopus 로고
    • Accuracy of left atrial and pulmonary artery wedge pressure in pure mitral regurgitation in predicting left ventricular end-diastolic pressure
    • Haskell RJ, French WJ,. Accuracy of left atrial and pulmonary artery wedge pressure in pure mitral regurgitation in predicting left ventricular end-diastolic pressure. Am J Cardiol 1988; 61: 136-141.
    • (1988) Am J Cardiol , vol.61 , pp. 136-141
    • Haskell, R.J.1    French, W.J.2
  • 17
    • 59449094988 scopus 로고    scopus 로고
    • Remote monitoring of patients with biventricular defibrillators through the CareLink system improves clinical management of arrhythmias and heart failure episodes
    • Santini M, Ricci RP, Lunati M, Landolina M, Perego GB, Marzegalli M, Schirru M, et al,. Remote monitoring of patients with biventricular defibrillators through the CareLink system improves clinical management of arrhythmias and heart failure episodes. J Interv Card Electrophysiol 2009; 24: 53-61.
    • (2009) J Interv Card Electrophysiol , vol.24 , pp. 53-61
    • Santini, M.1    Ricci, R.P.2    Lunati, M.3    Landolina, M.4    Perego, G.B.5    Marzegalli, M.6    Schirru, M.7
  • 18
    • 0031696273 scopus 로고    scopus 로고
    • A lung ultrasound sign allowing bedside distinction between pulmonary edema and COPD: The comet-tail artifact
    • DOI 10.1007/s001340050771
    • Lichtenstein D, Mezière G,. A lung ultrasound sign allowing bedside distinction between pulmonary edema and COPD: The comet-tail artifact. Intensive Care Med 1998; 24: 1331-1334. (Pubitemid 28564459)
    • (1998) Intensive Care Medicine , vol.24 , Issue.12 , pp. 1331-1334
    • Lichtenstein, D.1    Meziere, G.2
  • 19
    • 0032937034 scopus 로고    scopus 로고
    • The comet-tail artifact: An ultrasound sign ruling out pneumothorax
    • DOI 10.1007/s001340050862
    • Lichtenstein D, Mezière G, Biderman P, Gepner A,. The comet-tail artifact: An ultrasound sign ruling out pneumothorax. Intensive Care Med 1999; 25: 383-388. (Pubitemid 29192471)
    • (1999) Intensive Care Medicine , vol.25 , Issue.4 , pp. 383-388
    • Lichtenstein, D.1    Meziere, G.2    Biderman, P.3    Gepner, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.