메뉴 건너뛰기




Volumn 34, Issue 2, 2011, Pages 195-202

Development of a dosimetry inter-comparison for IMRT as part of site credentialing for a TROG multi-centre clinical trial for prostate cancer

Author keywords

IMRT; Multi centre clinical trials; Prostate cancer; Quality assurance; Radiochromic film dosimetry

Indexed keywords

ANTHROPOMORPHIC PHANTOMS; CLINICAL ONCOLOGY; CLINICAL TRIAL; CT DATA; FRACTIONATED IRRADIATION; IMRT; INTENSITY-MODULATED RADIATION THERAPY; INTERCOMPARISONS; INTERNATIONAL EXPERIENCES; MEASUREMENT UNCERTAINTY; ONTARIO; PROSTATE CANCER; PROSTATE CANCERS; RADIATION ONCOLOGY; RADIOCHROMIC FILM; RADIOCHROMIC FILM DOSIMETRY; TREATMENT PLANNING SYSTEMS;

EID: 80051682239     PISSN: 01589938     EISSN: None     Source Type: Journal    
DOI: 10.1007/s13246-011-0063-7     Document Type: Article
Times cited : (11)

References (21)
  • 1
    • 77954600968 scopus 로고    scopus 로고
    • Critical impact of radiotherapy protocol compliance and quality in the treatment of advanced head and neck cancer: Results from TROG 02.02
    • 20479390 10.1200/JCO.2009.27.4498
    • LJ Peters B O'Sullivan J Giralt TJ Fitzgerald A Trotti J Bernier, et al. 2010 Critical impact of radiotherapy protocol compliance and quality in the treatment of advanced head and neck cancer: results from TROG 02.02 J Clin Oncol 28 2996 3001 20479390 10.1200/JCO.2009.27.4498
    • (2010) J Clin Oncol , vol.28 , pp. 2996-3001
    • Peters, L.J.1    O'Sullivan, B.2    Giralt, J.3    Fitzgerald, T.J.4    Trotti, A.5    Bernier, J.6
  • 3
    • 80051698905 scopus 로고    scopus 로고
    • accessed 10 June 2010
    • http://www.clinicaltrials.gov/ct/show/NCT00304759 accessed 10 June 2010
  • 4
    • 40949134246 scopus 로고    scopus 로고
    • Intensity-modulated radiation therapy dose prescription, recording, and delivery: Patterns of variability among institutions and treatment planning systems
    • DOI 10.1093/jnci/djn020
    • IJ Das C-W Cheng KL Chopra RK Mitra SP Srivastava E Glatstein 2008 Intensity-modulated radiation therapy dose prescription, recording and delivery: patterns of variability amongst institutions and treatment planning systems J Nat Cancer Inst 100 300 307 18314476 10.1093/jnci/djn020 (Pubitemid 351480524)
    • (2008) Journal of the National Cancer Institute , vol.100 , Issue.5 , pp. 300-307
    • Das, I.J.1    Cheng, C.-W.2    Chopra, K.L.3    Mitra, R.K.4    Srivastava, S.P.5    Glatstein, E.6
  • 5
    • 80051689400 scopus 로고    scopus 로고
    • Report 83: Prescribing, recording, and reporting photon-beam intensity-modulated radiation therapy (IMRT)
    • ICRU
    • ICRU (2010) Report 83: prescribing, recording, and reporting photon-beam intensity-modulated radiation therapy (IMRT), Journal of the ICRU 10
    • (2010) Journal of the ICRU 10
  • 7
    • 41749118737 scopus 로고    scopus 로고
    • Quality assurance issues in conducting multi-institutional advanced technology clinical trials
    • DOI 10.1016/j.ijrobp.2007.07.2393, PII S0360301607043568
    • JA Purdy 2008 Quality assurance issues in conducting multi-institutional advanced technology clinical trials Int J Radiat Oncol Biol Phys 71 S66 S70 18406941 10.1016/j.ijrobp.2007.07.2393 (Pubitemid 351491464)
    • (2008) International Journal of Radiation Oncology Biology Physics , vol.71 , Issue.1 SUPPL.
    • Purdy, J.A.1
  • 8
    • 65349189168 scopus 로고    scopus 로고
    • Comprehensive Australasian multicentre dosimetric intercomparison: Issues, logistics and recommendations
    • 19453538 10.1111/j.1754-9485.2009.02047.x 1:STN:280: DC%2BD1Mzls1ensg%3D%3D
    • MA Ebert KM Harrison D Cornes SJ Howlett DJ Joseph T Kron CS Hamilton JW Denham 2009 Comprehensive Australasian multicentre dosimetric intercomparison: issues, logistics and recommendations J Med Imaging Radiat Oncol 53 119 131 19453538 10.1111/j.1754-9485.2009.02047.x 1:STN:280:DC%2BD1Mzls1ensg%3D%3D
    • (2009) J Med Imaging Radiat Oncol , vol.53 , pp. 119-131
    • Ebert, M.A.1    Harrison, K.M.2    Cornes, D.3    Howlett, S.J.4    Joseph, D.J.5    Kron, T.6    Hamilton, C.S.7    Denham, J.W.8
  • 9
    • 0036472111 scopus 로고    scopus 로고
    • Dosimetric intercomparison for two Australasian clinical trials using an anthropomorphic phantom
    • DOI 10.1016/S0360-3016(01)02682-7, PII S0360301601026827
    • T Kron C Hamilton M Roff J Denham 2002 Dosimetric intercomparison for two Australasian clinical trials using an anthropomorphic phantom Int J Radiat Oncol Biol Phys 52 566 579 11872306 10.1016/S0360-3016(01)02682-7 (Pubitemid 34170861)
    • (2002) International Journal of Radiation Oncology Biology Physics , vol.52 , Issue.2 , pp. 566-579
    • Kron, T.1    Hamilton, C.2    Roff, M.3    Denham, J.4
  • 11
    • 39149132529 scopus 로고    scopus 로고
    • Detailed review and analysis of complex radiotherapy clinical trial planning data: Evaluation and initial experience with the SWAN software system
    • 18077034 10.1016/j.radonc.2007.11.013
    • MA Ebert A Haworth R Kearvell B Hooton R Coleman N Spry S Bydder D Joseph 2008 Detailed review and analysis of complex radiotherapy clinical trial planning data: evaluation and initial experience with the SWAN software system Radiother Oncol 86 200 210 18077034 10.1016/j.radonc.2007.11.013
    • (2008) Radiother Oncol , vol.86 , pp. 200-210
    • Ebert, M.A.1    Haworth, A.2    Kearvell, R.3    Hooton, B.4    Coleman, R.5    Spry, N.6    Bydder, S.7    Joseph, D.8
  • 14
    • 0028850038 scopus 로고
    • White polystyrene as a substitute for water in high energy photon dosimetry
    • 8746716 10.1118/1.597652 1:STN:280:DyaK28zmtVCnsg%3D%3D
    • G Christ 1995 White polystyrene as a substitute for water in high energy photon dosimetry Med Phys 22 2097 2100 8746716 10.1118/1.597652 1:STN:280:DyaK28zmtVCnsg%3D%3D
    • (1995) Med Phys , vol.22 , pp. 2097-2100
    • Christ, G.1
  • 15
    • 38849173037 scopus 로고    scopus 로고
    • Accurate dosimetry with GafChromic™ EBT film of a 6 MV photon beam in water: What level is achievable?
    • DOI 10.1118/1.2828196
    • LJ van Battum D Hoffmans H Piersma S Heukelom 2008 Accurate dosimetry with GafChromic EBT film of a 6 MV photon beam in water: what level is achievable? Med Phys 35 704 716 18383692 10.1118/1.2828196 (Pubitemid 351190890)
    • (2008) Medical Physics , vol.35 , Issue.2 , pp. 704-716
    • Van Battum, L.J.1    Hoffmans, D.2    Piersma, H.3    Heukelom, S.4
  • 16
    • 0031861573 scopus 로고    scopus 로고
    • A technique for the quantitative evaluation of dose distributions
    • DOI 10.1118/1.598248
    • DA Low WB Harms S Mutic JA Purdy 1998 A technique for the quantitative evaluation of dose distributions Med Phys 25 656 661 9608475 10.1118/1.598248 1:STN:280:DyaK1c3ntFCjsA%3D%3D (Pubitemid 28234885)
    • (1998) Medical Physics , vol.25 , Issue.5 , pp. 656-661
    • Low, D.A.1    Harms, W.B.2    Mutic, S.3    Purdy, J.A.4
  • 18
    • 70350726816 scopus 로고    scopus 로고
    • IMRT commissioning: Multiple institution planning and dosimetry comparisons, a report from AAPM task group 119
    • 19994544 10.1118/1.3238104
    • GA Ezzell JW Burmeister N Dogan TJ LoSasso JG Mechalakos D Mihailidis, et al. 2009 IMRT commissioning: multiple institution planning and dosimetry comparisons, a report from AAPM task group 119 Med Phys 36 5359 5373 19994544 10.1118/1.3238104
    • (2009) Med Phys , vol.36 , pp. 5359-5373
    • Ezzell, G.A.1    Burmeister, J.W.2    Dogan, N.3    Losasso, T.J.4    Mechalakos, J.G.5    Mihailidis, D.6
  • 20
    • 0029035150 scopus 로고
    • BEAM: A Monte Carlo code to simulate radiotherapy treatment units
    • 7643786 10.1118/1.597552 1:STN:280:DyaK2MzntFGgsQ%3D%3D
    • DWO Rogers BA Feddegon GX Ding J We 1995 BEAM: a Monte Carlo code to simulate radiotherapy treatment units Med Phys 22 503 524 7643786 10.1118/1.597552 1:STN:280:DyaK2MzntFGgsQ%3D%3D
    • (1995) Med Phys , vol.22 , pp. 503-524
    • Rogers, D.W.O.1    Feddegon, B.A.2    Ding, G.X.3    We, J.4
  • 21
    • 33846582373 scopus 로고    scopus 로고
    • Energy dependence (75 kVp to 18 MV) of radiochromic films assessed using a real-time optical dosimeter
    • DOI 10.1118/1.2431425
    • A Rink IA Vitkin DA Jaffray 2007 Energy dependence (75 kVp to 18 MV) of radiochromic films assessed using a real-time optical dosimeter Med Phys 34 458 463 17388161 10.1118/1.2431425 1:CAS:528:DC%2BD2sXhsFCgt7w%3D (Pubitemid 46185123)
    • (2007) Medical Physics , vol.34 , Issue.2 , pp. 458-463
    • Rink, A.1    Vitkin, I.A.2    Jaffray, D.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.