메뉴 건너뛰기




Volumn 44, Issue 12, 2011, Pages 2138-2149

Study on hydrogen ion-selective solid contact electrodes based on decamethylcyclopentasiloxane

Author keywords

Conducting polymer; Decamethylcyclopentasiloxane; Hydrogen ion sensor; ISE; SCE

Indexed keywords


EID: 80051682102     PISSN: 00032719     EISSN: 1532236X     Source Type: Journal    
DOI: 10.1080/00032719.2010.546023     Document Type: Article
Times cited : (2)

References (38)
  • 2
    • 0034632233 scopus 로고    scopus 로고
    • Ionophore-based membrane electrodes: New analytical concepts and non-classical response mechanisms
    • Bakker, E., and M. E. Meyerhoff. 2000. Ionophore-based membrane electrodes: New analytical concepts and non-classical response mechanisms. Anal. Chim. Acta 416: 121-137.
    • (2000) Anal. Chim. Acta , vol.416 , pp. 121-137
    • Bakker, E.1    Meyerhoff, M.E.2
  • 3
    • 0034653614 scopus 로고    scopus 로고
    • Selectivity of potentiometric ion sensors. Anal
    • Bakker, E., E. Pretsch, and P. Buhlmann. 2000. Selectivity of potentiometric ion sensors. Anal. Chem. 72: 11127-11133.
    • (2000) Chem , vol.72 , pp. 11127-11133
    • Bakker, E.1    Pretsch, E.2    Buhlmann, P.3
  • 5
    • 30944444781 scopus 로고    scopus 로고
    • Conducting polymer-based solid-state ion-selective electrodes
    • Bobacka, J. 2006. Conducting polymer-based solid-state ion-selective electrodes. Electroanalysis 1: 7-18.
    • (2006) Electroanalysis , vol.1 , pp. 7-18
    • Bobacka, J.1
  • 6
    • 84996009110 scopus 로고
    • Neutral-carrier-based ion-selective microelectrodes design and application
    • Buhrer, T., P. Gehrig, and W. Simon. 1988. Neutral-carrier-based ion-selective microelectrodes design and application. Anal. Sci. 4: 547-557.
    • (1988) Anal. Sci , vol.4 , pp. 547-557
    • Buhrer, T.1    Gehrig, P.2    Simon, W.3
  • 7
    • 0001522037 scopus 로고
    • Anionic responses of electrochemically synthesized polypyrrole films
    • Cadogan, A., A. Lewenstam, and A. Ivaska. 1992. Anionic responses of electrochemically synthesized polypyrrole films. Talanta 39: 617-620.
    • (1992) Talanta , vol.39 , pp. 617-620
    • Cadogan, A.1    Lewenstam, A.2    Ivaska, A.3
  • 8
    • 0000379167 scopus 로고
    • A coated wire ion-selective electrodes for the determination of zinc(II)
    • Catterall, R. W., and C.-P. Pui. 1976. A coated wire ion-selective electrodes for the determination of zinc(II). Anal. Chim. Acta 87: 419-427.
    • (1976) Anal. Chim. Acta , vol.87 , pp. 419-427
    • Catterall, R.W.1    Pui, C.-P.2
  • 9
    • 84996009110 scopus 로고
    • Neutral-carrier-based ion-selective microelectrodes design and application
    • Chao, P., D. Ammann, and W. Simon. 1988. Neutral-carrier-based ion-selective microelectrodes design and application. Anal. Sci. 4: 547-557.
    • (1988) Anal. Sci , vol.4 , pp. 547-557
    • Chao, P.1    Ammann, D.2    Simon, W.3
  • 10
    • 0032428915 scopus 로고    scopus 로고
    • Hydrogen ion-selective membrane electrodes based on alkyldibenzylamines as neutral carriers
    • Cho, D. H., K. C. Chung, and M. Y. Park. 1998. Hydrogen ion-selective membrane electrodes based on alkyldibenzylamines as neutral carriers. Talanta 47: 815-821.
    • (1998) Talanta , vol.47 , pp. 815-821
    • Cho, D.H.1    Chung, K.C.2    Park, M.Y.3
  • 11
    • 0017256811 scopus 로고
    • 2 in vivo sensor
    • Coon, R. L., N. C. Lai, and J. P. Kampine. 1976. Evaluation of a dual-function pH and pCO2 in vivo sensor. J. Appl. Physiol. 40: 625-629.
    • (1976) J. Appl. Physiol , vol.40 , pp. 625-629
    • Coon, R.L.1    Lai, N.C.2    Kampine, J.P.3
  • 12
    • 0037843933 scopus 로고
    • Combination ion-selective electrode based on solvent polymeric membranes
    • Dohner, R. E., and W. Simon. 1979. Combination ion-selective electrode based on solvent polymeric membranes. Anal. Lett. 12: 205-211.
    • (1979) Anal. Lett , vol.12 , pp. 205-211
    • Dohner, R.E.1    Simon, W.2
  • 13
    • 0002636537 scopus 로고
    • Liquid membrane, pH electrode based on a synthetic proton carrier
    • Erne, D., D. Ammann, and W. Simon. 1979. Liquid membrane, pH electrode based on a synthetic proton carrier. Chimia. 33: 88-90.
    • (1979) Chimia , vol.33 , pp. 88-90
    • Erne, D.1    Ammann, D.2    Simon, W.3
  • 14
    • 0344474538 scopus 로고    scopus 로고
    • Hydrogen ion selective electrode based on poly(1-amino-anthracene)film
    • Faria, R. C., and L. O. S. Bulhoes. 1998. Hydrogen ion selective electrode based on poly(1-amino-anthracene)film. Anal. Chim. Acta 377: 21-27.
    • (1998) Anal. Chim. Acta , vol.377 , pp. 21-27
    • Faria, R.C.1    Bulhoes, L.O.S.2
  • 15
    • 77952273535 scopus 로고    scopus 로고
    • Influence of the electrolyte cation and anion sizes on the redox process of PPy/PVS films in acetonitrile solution
    • Fernandez Romero, A. J., and P. Perez Manogil. 2010. Influence of the electrolyte cation and anion sizes on the redox process of PPy/PVS films in acetonitrile solution. J. Solid State Electrochem. 14: 841-849.
    • (2010) J. Solid State Electrochem , vol.14 , pp. 841-849
    • Fernandez Romero, A.J.1    Perez, M.P.2
  • 16
    • 7944220624 scopus 로고    scopus 로고
    • A Hydrogen ion-selective poly(aniline) solid contact electrode based on dibenzylpyrenemethylamine ionophore for highly acidic solutions
    • Han, W. S., K. C. Chung, M. H. Kim, H. B. Ko, Y. H. Lee, and T. K. Hong. 2004. A Hydrogen ion-selective poly(aniline) solid contact electrode based on dibenzylpyrenemethylamine ionophore for highly acidic solutions. Anal. Sci. 20: 1419-1422.
    • (2004) Anal. Sci , vol.20 , pp. 1419-1422
    • Han, W.S.1    Chung, K.C.2    Kim, M.H.3    Ko, H.B.4    Lee, Y.H.5    Hong, T.K.6
  • 17
    • 0034864711 scopus 로고    scopus 로고
    • All solid state hydrogen ion selective electrode based on a tribenzylamine neutral carrier in a poly(vinyl chloride) membrane with a poly(aniline) solid contact
    • Han, W. S., M. Y. Park, K. C. Chung, D. H. Cho, and T. K. Hong. 2001. All solid state hydrogen ion selective electrode based on a tribenzylamine neutral carrier in a poly(vinyl chloride) membrane with a poly(aniline) solid contact. Electroanalysis 13: 955-959.
    • (2001) Electroanalysis , vol.13 , pp. 955-959
    • Han, W.S.1    Park, M.Y.2    Chung, K.C.3    Cho, D.H.4    Hong, T.K.5
  • 18
    • 4243820407 scopus 로고
    • Calcium-selective electrodes with PVC membranes and solid internal contacts
    • Hulanicki, A., and M. Trojanowicz. 1976. Calcium-selective electrodes with PVC membranes and solid internal contacts. Anal. Chim. Acta 87: 411-417.
    • (1976) Anal. Chim. Acta , vol.87 , pp. 411-417
    • Hulanicki, A.1    Trojanowicz, M.2
  • 19
    • 1842860019 scopus 로고    scopus 로고
    • Light emitting diodes based on polyaniline
    • Kim, E. O., S. B. Park, and S. J. Lee. 2001. Light emitting diodes based on polyaniline. J. Kor. Chem. Soc. 45: 156-161.
    • (2001) J. Kor. Chem. Soc , vol.45 , pp. 156-161
    • Kim, E.O.1    Park, S.B.2    Lee, S.J.3
  • 20
    • 20444482148 scopus 로고    scopus 로고
    • Stability enhancement of all-solid-state H{thorn} ISEs with crow-linked silicon urethane matrices
    • Kwon, N. H., M. S. Won, D. S. Park, and Y. B. Shim. 2005. Stability enhancement of all-solid-state H{thorn} ISEs with crow-linked silicon urethane matrices. Electroanalysis 17: 641-647.
    • (2005) Electroanalysis , vol.17 , pp. 641-647
    • Kwon, N.H.1    Won, M.S.2    Park, D.S.3    Shim, Y.B.4
  • 22
    • 0001243606 scopus 로고
    • + selective solvent polymeric membrane electrodes fabricated from modified PVC membranes
    • + selective solvent polymeric membrane electrodes fabricated from modified PVC membranes. Talanta 40: 957-967.
    • (1993) Talanta , vol.40 , pp. 957-967
    • Linder, E.1    Cosofret, V.V.2    Buck, R.P.3
  • 23
    • 34248663496 scopus 로고    scopus 로고
    • Plastic membrane sensor from a disposed combined glass electrode
    • Marafie, H. F., A. H. Shoukry, and L. A. Alshatti. 2007. Plastic membrane sensor from a disposed combined glass electrode. J. Chem. Edu. 84: 793-796.
    • (2007) J. Chem. Edu , vol.84 , pp. 793-796
    • Marafie, H.F.1    Shoukry, A.H.2    Alshatti, L.A.3
  • 24
    • 0002006247 scopus 로고    scopus 로고
    • All-solid-state potentiometric sensors for potassium and sodium based on poly(pyrrole) solid contact
    • Michalska, A., A. Hulanicki, and A. Lewenatam. 1997. All-solid-state potentiometric sensors for potassium and sodium based on poly(pyrrole) solid contact. Microchem. J. 57: 59-64.
    • (1997) Microchem. J , vol.57 , pp. 59-64
    • Michalska, A.1    Hulanicki, A.2    Lewenatam, A.3
  • 25
    • 0029990989 scopus 로고    scopus 로고
    • Conducting polymer-based ion-selective electrodes
    • Migdalski, J., T. Blaz, and A. Lewenstam. 1996. Conducting polymer-based ion-selective electrodes. Anal. Chim. Acta. 322: 141-149.
    • (1996) Anal. Chim. Acta , vol.322 , pp. 141-149
    • Migdalski, J.1    Blaz, T.2    Lewenstam, A.3
  • 26
    • 0023383420 scopus 로고
    • Solvent polymeric membrane pH catheter electrode for intraluminal measurements in the upper gastrointestinal tract
    • Oesch, U., Z. Brzozka, A. Xu, and W. Simon. 1987. Solvent polymeric membrane pH catheter electrode for intraluminal measurements in the upper gastrointestinal tract. Med. Biol. Eng. Comput. 25: 414-419.
    • (1987) Med. Biol. Eng. Comput , vol.25 , pp. 414-419
    • Oesch, U.1    Brzozka, Z.2    Xu, A.3    Simon, W.4
  • 27
    • 34547591750 scopus 로고    scopus 로고
    • Guidelines for improving the lower detection limit of ion-selective electrodes: A systematic approach
    • Radu, A., S. Peper, E. Bakker, and D. Diamond. 2007. Guidelines for improving the lower detection limit of ion-selective electrodes: A systematic approach. Electro-analysis 19: 144-154.
    • (2007) Electro-analysis , vol.19 , pp. 144-154
    • Radu, A.1    Peper, S.2    Bakker, E.3    Diamond, D.4
  • 28
    • 0033119633 scopus 로고    scopus 로고
    • Triiodide PVC membrane electrode based on a charge-transfer complex of iodine with 2,4,6,8-tetraphenyl-2,4,6,8-tetraazabicyclo[3.3.0] octane
    • Rhollahi, A., and M. Shamsipur. 1999. Triiodide PVC membrane electrode based on a charge-transfer complex of iodine with 2,4,6,8-tetraphenyl-2,4,6,8-tetraazabicyclo[3.3.0] octane. Anal. Chem. 71: 1350-1353.
    • (1999) Anal. Chem , vol.71 , pp. 1350-1353
    • Rhollahi, A.1    Shamsipur, M.2
  • 29
    • 0032146532 scopus 로고    scopus 로고
    • Lead ion selective PVC membrane electrode based on 5,50-dithiobis-(2-nitrobenzoic acid)
    • Rouhollahi, A., M. R. Ganjali, and M. Shamsipur. 1998. Lead ion selective PVC membrane electrode based on 5,50-dithiobis-(2-nitrobenzoic acid). Talanta 46: 1341.
    • (1998) Talanta , vol.46 , pp. 1341
    • Rouhollahi, A.1    Ganjali, M.R.2    Shamsipur, M.3
  • 30
    • 0005841754 scopus 로고    scopus 로고
    • - selective silicon rubber membrane electrode to reduce interference for salicylate
    • - selective silicon rubber membrane electrode to reduce interference for salicylate. J. Kor. Chem. Soc. 41: 653.
    • (1997) J. Kor. Chem. Soc , vol.41 , pp. 653
    • Sakong, D.S.1    Kim, J.M.2    Cha, G.S.3
  • 31
    • 0000568006 scopus 로고
    • A hydrogen ion-selective liquid-membrane electrode based on tri-n-dodecylamine as neutral carrier
    • Schulthess, P., Y. Shijo, H. N. Pham, E. D. Ammann, and W. Simon. 1981. A hydrogen ion-selective liquid-membrane electrode based on tri-n-dodecylamine as neutral carrier. Anal. Chim. Acta. 131: 111-116.
    • (1981) Anal. Chim. Acta , vol.131 , pp. 111-116
    • Schulthess, P.1    Shijo, Y.2    Pham, H.N.3    Ammann, E.D.4    Simon, W.5
  • 32
    • 0034524406 scopus 로고    scopus 로고
    • A PVC-based dibenzodiaza-15-crown-4 membrane potentiometric sensor for Ni(II)
    • Shamsipur, M., and S. Kazemi. 2000. A PVC-based dibenzodiaza-15-crown-4 membrane potentiometric sensor for Ni(II). Electroanalysis 12: 1472-1475.
    • (2000) Electroanalysis , vol.12 , pp. 1472-1475
    • Shamsipur, M.1    Kazemi, S.2
  • 33
    • 38949161228 scopus 로고    scopus 로고
    • Lead ion-selective polypyrrole solid contact electrode based on crown ether
    • Shim, J., E. J. Jang, and K. C. Chung. 2007. Lead ion-selective polypyrrole solid contact electrode based on crown ether. Anal. Lett. 40: 3038-3049.
    • (2007) Anal. Lett , vol.40 , pp. 3038-3049
    • Shim, J.1    Jang, E.J.2    Chung, K.C.3
  • 35
    • 0035967251 scopus 로고    scopus 로고
    • 2+-selective electrodes with lariat crown ethers as ionophores
    • 2+-selective electrodes with lariat crown ethers as ionophores. Anal. Chim. Acta 432: 261-267.
    • (2001) Anal. Chim. Acta , vol.432 , pp. 261-267
    • Su, C.C.1    Chang, M.C.2    Liu, L.K.3
  • 36
    • 0000434325 scopus 로고
    • Coated wire sodium-and potassium-selective electrodes based on bis(crown ether) compounds
    • Tamura, H., K. Kimura, and T. Shono. 1982. Coated wire sodium-and potassium-selective electrodes based on bis(crown ether) compounds. Anal. Chem. 54: 1224-1227.
    • (1982) Anal. Chem , vol.54 , pp. 1224-1227
    • Tamura, H.1    Kimura, K.2    Shono, T.3
  • 38
    • 0000488414 scopus 로고
    • Chemically modified electrode based on poly[tetra(4-aminophenyl)porphyrin]as a pH sensor
    • Yuan, R., Y. Q. Chai, G. L. Shen, and R. Q. Yu. 1993. Chemically modified electrode based on poly[tetra(4-aminophenyl)porphyrin]as a pH sensor. Talanta 40: 1255-1259.
    • (1993) Talanta , vol.40 , pp. 1255-1259
    • Yuan, R.1    Chai, Y.Q.2    Shen, G.L.3    Yu, R.Q.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.