메뉴 건너뛰기




Volumn 174, Issue 3, 2011, Pages 321-327

Highly sensitive carbon paste electrode with silver-filled carbon nanotubes as a sensing element for determination of free cyanide ion in aqueous solutions

Author keywords

Carbon past electrode; Cyanide ion; Filled nanotube; Ion selective electrode; Silver(I)

Indexed keywords


EID: 80051648451     PISSN: 00263672     EISSN: 14365073     Source Type: Journal    
DOI: 10.1007/s00604-011-0629-9     Document Type: Article
Times cited : (13)

References (40)
  • 1
    • 0348025755 scopus 로고
    • Trace determination and speciation of cyanide ion by atomic absorption spectroscopy
    • Rosentreter JJ, Skogerboe RK (1991) Trace determination and speciation of cyanide ion by atomic absorption spectroscopy. Anal Chem 63: 682-688.
    • (1991) Anal Chem , vol.63 , pp. 682-688
    • Rosentreter, J.J.1    Skogerboe, R.K.2
  • 2
    • 1542298153 scopus 로고    scopus 로고
    • Characterization and availability of cyanide in solid mine tailings from gold extraction plants
    • Zagury GJ, Oudjehani K, Deschenes L (2004) Characterization and availability of cyanide in solid mine tailings from gold extraction plants. Sci Total Environ 320: 211-224.
    • (2004) Sci Total Environ , vol.320 , pp. 211-224
    • Zagury, G.J.1    Oudjehani, K.2    Deschenes, L.3
  • 3
    • 14044265784 scopus 로고    scopus 로고
    • Cyanide-induced a kinetic rigid syndrome: clinical, MRI, FDG-PET, β-CIT and HMPAO SPECT findings
    • Zaknun JJ, Stieglbauer K, Trenkler J (2005) Cyanide-induced a kinetic rigid syndrome: clinical, MRI, FDG-PET, β-CIT and HMPAO SPECT findings. Parkinsonism Relat Disord 11: 125-129.
    • (2005) Parkinsonism Relat Disord , vol.11 , pp. 125-129
    • Zaknun, J.J.1    Stieglbauer, K.2    Trenkler, J.3
  • 4
    • 0037123457 scopus 로고    scopus 로고
    • Anion-exchange chromatography of metal cyanide complexes with gradient separation and direct UV detection
    • Karmarkar S (2002) Anion-exchange chromatography of metal cyanide complexes with gradient separation and direct UV detection. J Chromatogr A 956: 229-235.
    • (2002) J Chromatogr A , vol.956 , pp. 229-235
    • Karmarkar, S.1
  • 5
    • 0037095337 scopus 로고    scopus 로고
    • Construction of a sensor for the determination of cyanide in industrial effluents: a method based on quartz crystal microbalance
    • Mirmohseni A, Alipour A (2002) Construction of a sensor for the determination of cyanide in industrial effluents: a method based on quartz crystal microbalance. Sens Actuators B 84: 245-251.
    • (2002) Sens Actuators B , vol.84 , pp. 245-251
    • Mirmohseni, A.1    Alipour, A.2
  • 7
    • 0037427651 scopus 로고    scopus 로고
    • Development of a method for estimating an accurate equivalence point in nickel titration of cyanide ions
    • Suzuki T, Hioki A, Kurahashi M (2003) Development of a method for estimating an accurate equivalence point in nickel titration of cyanide ions. Anal Chim Acta 476: 159-165.
    • (2003) Anal Chim Acta , vol.476 , pp. 159-165
    • Suzuki, T.1    Hioki, A.2    Kurahashi, M.3
  • 8
    • 0036894487 scopus 로고    scopus 로고
    • Segmented flow injection, UV digestion, and amperometric detection for the determination of total cyanide in wastewater treatment plant effluents
    • Weinberg HS, Cook SJ (2002) Segmented flow injection, UV digestion, and amperometric detection for the determination of total cyanide in wastewater treatment plant effluents. Anal Chem 74: 6055-6063.
    • (2002) Anal Chem , vol.74 , pp. 6055-6063
    • Weinberg, H.S.1    Cook, S.J.2
  • 9
    • 0026196731 scopus 로고
    • Indirect determination of free cyanide in industrial waste effluent by atomic absorption spectrometry
    • Chattaraj S, Das AK (1991) Indirect determination of free cyanide in industrial waste effluent by atomic absorption spectrometry. Analyst 116: 739-741.
    • (1991) Analyst , vol.116 , pp. 739-741
    • Chattaraj, S.1    Das, A.K.2
  • 10
    • 0036227588 scopus 로고    scopus 로고
    • Determination of blood cyanide by HPLC-MS
    • Tracqui A, Raul JS, Geraut A (2002) Determination of blood cyanide by HPLC-MS. J Anal Toxicol 26: 144-148.
    • (2002) J Anal Toxicol , vol.26 , pp. 144-148
    • Tracqui, A.1    Raul, J.S.2    Geraut, A.3
  • 11
    • 33750986177 scopus 로고    scopus 로고
    • Simple photometric determination of free cyanide ion in aqueous solution with 2,6-dichlorophenolindophenol
    • Yari A, Kargosha K (2006) Simple photometric determination of free cyanide ion in aqueous solution with 2, 6-dichlorophenolindophenol. Centr Europ J Chem 4: 329-337.
    • (2006) Centr Europ J Chem , vol.4 , pp. 329-337
    • Yari, A.1    Kargosha, K.2
  • 12
    • 34247330072 scopus 로고    scopus 로고
    • Indirect determination of free cyanide in water and industrial waste water by flow injection-atomic absorption spectrometry
    • Dadfarnia S, Shabani AMH, Tamadon F, Rezaei M (2007) Indirect determination of free cyanide in water and industrial waste water by flow injection-atomic absorption spectrometry. Microchim Acta 158: 159-163.
    • (2007) Microchim Acta , vol.158 , pp. 159-163
    • Dadfarnia, S.1    Shabani, A.M.H.2    Tamadon, F.3    Rezaei, M.4
  • 13
    • 0001615113 scopus 로고
    • Chemically modified carbon paste electrodes
    • Ravichandran K, Baldwin RP (1981) Chemically modified carbon paste electrodes. J Electroanal Chem 126: 293-300.
    • (1981) J Electroanal Chem , vol.126 , pp. 293-300
    • Ravichandran, K.1    Baldwin, R.P.2
  • 15
    • 0020802364 scopus 로고
    • Phenylenediamine-containing chemically modified carbon paste electrodes as catalytic voltammetric sensors
    • Ravichandran K, Baldwin RP (1983) Phenylenediamine-containing chemically modified carbon paste electrodes as catalytic voltammetric sensors. Anal Chem 55: 1586-1591.
    • (1983) Anal Chem , vol.55 , pp. 1586-1591
    • Ravichandran, K.1    Baldwin, R.P.2
  • 16
    • 84987553162 scopus 로고
    • Chemically modified carbon paste electrodes in voltammetric analysis
    • Kalcher K, Grabec I (1990) Chemically modified carbon paste electrodes in voltammetric analysis. Electroanalysis 2: 419-433.
    • (1990) Electroanalysis , vol.2 , pp. 419-433
    • Kalcher, K.1    Grabec, I.2
  • 17
    • 0035708911 scopus 로고    scopus 로고
    • Carbon paste electrodes in modern electroanalysis
    • Ivan S, Carel V, Jiri B, Jiri Z (2001) Carbon paste electrodes in modern electroanalysis. Crit Rev Anal Chem 31: 311-345.
    • (2001) Crit Rev Anal Chem , vol.31 , pp. 311-345
    • Ivan, S.1    Carel, V.2    Jiri, B.3    Jiri, Z.4
  • 18
    • 0000099667 scopus 로고    scopus 로고
    • Silica-modified carbon paste electrode for copper determination in ammoniacal medium
    • Walcarius A, Bessiere J (1997) Silica-modified carbon paste electrode for copper determination in ammoniacal medium. Electroanalysis 9: 707-713.
    • (1997) Electroanalysis , vol.9 , pp. 707-713
    • Walcarius, A.1    Bessiere, J.2
  • 19
    • 0028093219 scopus 로고
    • Voltammetric determination of trace metals and organics after accumulation at modified electrodes
    • Arrigan DWM (1994) Voltammetric determination of trace metals and organics after accumulation at modified electrodes. Analyst 119: 1953-1966.
    • (1994) Analyst , vol.119 , pp. 1953-1966
    • Arrigan, D.W.M.1
  • 20
    • 0036605739 scopus 로고    scopus 로고
    • The use of carbon paste electrode in the direct voltammetric determination of tryptophan in pharmaceutical formulations
    • Fiorucci AR, Cavalheiro ETG (2002) The use of carbon paste electrode in the direct voltammetric determination of tryptophan in pharmaceutical formulations. J Pharmac Biomed Anal 28: 909-915.
    • (2002) J Pharmac Biomed Anal , vol.28 , pp. 909-915
    • Fiorucci, A.R.1    Cavalheiro, E.T.G.2
  • 21
    • 77349104865 scopus 로고    scopus 로고
    • Carbon paste electrodes in electroanalytical chemistry
    • Vytras K, Svancara I, Metelka R (2009) Carbon paste electrodes in electroanalytical chemistry. J Serb Chem Soc 74: 1021-1033.
    • (2009) J Serb Chem Soc , vol.74 , pp. 1021-1033
    • Vytras, K.1    Svancara, I.2    Metelka, R.3
  • 24
    • 0037008487 scopus 로고    scopus 로고
    • Carbon nanotubes: the route toward applications
    • Baughman RH, Zakhidov A, de Heer WA (2002) Carbon nanotubes: the route toward applications. Science 297: 787-792.
    • (2002) Science , vol.297 , pp. 787-792
    • Baughman, R.H.1    Zakhidov, A.2    de Heer, W.A.3
  • 25
    • 0036947839 scopus 로고    scopus 로고
    • Electrochemical sensors based on carbon nanotubes
    • Zhao Q, Gan Z, Zhuang Q (2002) Electrochemical sensors based on carbon nanotubes. Electroanalysis 14: 1609-1613.
    • (2002) Electroanalysis , vol.14 , pp. 1609-1613
    • Zhao, Q.1    Gan, Z.2    Zhuang, Q.3
  • 26
    • 0041344449 scopus 로고    scopus 로고
    • Carbon-nanotube-modified glassy carbon electrodes for amplified label-free electrochemical detection of DNA hybridization
    • Wang J, Kawde AN, Musameh M (2003) Carbon-nanotube-modified glassy carbon electrodes for amplified label-free electrochemical detection of DNA hybridization. Analyst 128: 912-916.
    • (2003) Analyst , vol.128 , pp. 912-916
    • Wang, J.1    Kawde, A.N.2    Musameh, M.3
  • 28
    • 0034731178 scopus 로고    scopus 로고
    • A novel approach to bulk synthesis of carbon nanotubes filled with metal by a catalytic chemical vapor deposition method
    • Sinha AK, Hwang DW, Hwang LP (2000) A novel approach to bulk synthesis of carbon nanotubes filled with metal by a catalytic chemical vapor deposition method. Chem Phys Lett 332: 455-460.
    • (2000) Chem Phys Lett , vol.332 , pp. 455-460
    • Sinha, A.K.1    Hwang, D.W.2    Hwang, L.P.3
  • 29
    • 80051644971 scopus 로고
    • Voltammetric determination of cyanide ions using preconcentration at a carbon-paste electrode modified with liquid crystals
    • Ulakhovich NA, Zakieva DZ, Yu GG, Budnikov GK (1993) Voltammetric determination of cyanide ions using preconcentration at a carbon-paste electrode modified with liquid crystals. J Anal Chem (Transl of Zh Anal Khim) 48: 731-733.
    • (1993) J Anal Chem (Transl. Of Zh. Anal Khim) , vol.48 , pp. 731-733
    • Ulakhovich, N.A.1    Zakieva, D.Z.2    Yu, G.G.3    Budnikov, G.K.4
  • 30
    • 0001247840 scopus 로고
    • Cyanide determination using an amperometric biosensor based on cytochrome oxidase inhibition
    • Amine A, Alafandy M, Kauffmann JM, Pekli MN (1995) Cyanide determination using an amperometric biosensor based on cytochrome oxidase inhibition. Anal Chem 67: 2822-2827.
    • (1995) Anal Chem , vol.67 , pp. 2822-2827
    • Amine, A.1    Alafandy, M.2    Kauffmann, J.M.3    Pekli, M.N.4
  • 31
    • 18844408629 scopus 로고    scopus 로고
    • A selective modified carbon paste electrode for determination of cyanide using tetra-3,4-pyridinoporphyrazinatocobalt(II)
    • Abbaspour A, Asadi M, Ghaffarinejad A, Safaei E (2005) A selective modified carbon paste electrode for determination of cyanide using tetra-3, 4-pyridinoporphyrazinatocobalt(II). Talanta 66: 931-936.
    • (2005) Talanta , vol.66 , pp. 931-936
    • Abbaspour, A.1    Asadi, M.2    Ghaffarinejad, A.3    Safaei, E.4
  • 32
    • 48749092060 scopus 로고    scopus 로고
    • New nanocomposites containing metal nanoparticles carbon nanotube and polymer
    • Sepahvand R, Adeli M, Astinchap B, Kabiri R (2008) New nanocomposites containing metal nanoparticles carbon nanotube and polymer. J Nanopart Res 10: 1309-1318.
    • (2008) J Nanopart Res , vol.10 , pp. 1309-1318
    • Sepahvand, R.1    Adeli, M.2    Astinchap, B.3    Kabiri, R.4
  • 33
    • 33748277577 scopus 로고    scopus 로고
    • Ion permeation dynamics in carbon nanotubes
    • Liu H, Murad S, Jameson CJ (2006) Ion permeation dynamics in carbon nanotubes. J Chem Phys 125: 084713-084726.
    • (2006) J Chem Phys , vol.125 , pp. 084713-084726
    • Liu, H.1    Murad, S.2    Jameson, C.J.3
  • 34
    • 77952326628 scopus 로고    scopus 로고
    • Molecular dynamics simulations of ion transport through carbon nanotubes. I. Influence of geometry, ion specificity, and many-body interactions
    • Beu TA (2010) Molecular dynamics simulations of ion transport through carbon nanotubes. I. Influence of geometry, ion specificity, and many-body interactions. J Chem Phys 132: 164513-164528.
    • (2010) J Chem Phys , vol.132 , pp. 164513-164528
    • Beu, T.A.1
  • 35
    • 33751280020 scopus 로고    scopus 로고
    • + ion transport in an anion-doped carbon nanotube
    • + ion transport in an anion-doped carbon nanotube. J Phys Chem B 110: 20671-20677.
    • (2006) J Phys Chem B , vol.110 , pp. 20671-20677
    • Sumikama, T.1    Saito, S.2    Ohmine, I.3
  • 36
    • 84961471218 scopus 로고
    • Definition and determination of response time of ion selective electrodes
    • Lindner E, Toth K, Pungor E (1986) Definition and determination of response time of ion selective electrodes. Pure Appl Chem 58: 469-479.
    • (1986) Pure Appl Chem , vol.58 , pp. 469-479
    • Lindner, E.1    Toth, K.2    Pungor, E.3
  • 37
    • 84930167786 scopus 로고
    • Recommendations for nomenclature of ion-selective electrodes
    • Buck RP, Lindner E (1994) Recommendations for nomenclature of ion-selective electrodes. Pure Appl Chem 66: 2527-2536.
    • (1994) Pure Appl Chem , vol.66 , pp. 2527-2536
    • Buck, R.P.1    Lindner, E.2
  • 38
    • 2342578719 scopus 로고    scopus 로고
    • Response time of ion-selective electrodes: current usage versus IUPAC recommendations
    • Macca C (2004) Response time of ion-selective electrodes: current usage versus IUPAC recommendations. Anal Chim Acta 512: 183-190.
    • (2004) Anal Chim Acta , vol.512 , pp. 183-190
    • Macca, C.1
  • 40
    • 0034653614 scopus 로고    scopus 로고
    • Selectivity of potentiometric ion sensors
    • Pretsch E, Bakker E, Buhlmann P (2000) Selectivity of potentiometric ion sensors. Anal Chem 72: 1127-1133.
    • (2000) Anal Chem , vol.72 , pp. 1127-1133
    • Pretsch, E.1    Bakker, E.2    Buhlmann, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.