메뉴 건너뛰기




Volumn 29, Issue 10, 2011, Pages 1470-1475

The weighted optimal common shape technique improves identification of the hip joint center of rotation in vivo

Author keywords

biomechanics; functional analysis; joint centers; optimal common shape technique; SCoRE residual; soft tissue artifact

Indexed keywords

ADULT; AGED; ARTICLE; ARTIFACT; CLINICAL ARTICLE; CONTROLLED STUDY; FEMALE; HIP; HIP CENTER OF ROTATION; HUMAN; JOINT EXAMINATION; KINEMATICS; MALE; PRIORITY JOURNAL; SOFT TISSUE; SOFT TISSUE ARTIFACT; SYMMETRICAL CENTER OF ROTATION ESTIMATION; TOTAL HIP PROSTHESIS; WEIGHTED OPTIMAL COMMON SHAPE TECHNIQUE;

EID: 80051550131     PISSN: 07360266     EISSN: 1554527X     Source Type: Journal    
DOI: 10.1002/jor.21426     Document Type: Article
Times cited : (41)

References (37)
  • 1
    • 33846954779 scopus 로고    scopus 로고
    • Effects of movement for estimating the hip joint centre
    • DOI 10.1016/j.gaitpost.2006.04.010, PII S0966636206000543
    • Begon M, Monnet T, Lacouture P,. 2007. Effects of movement for estimating the hip joint centre. Gait Posture 25 (3): 353-359. (Pubitemid 46242195)
    • (2007) Gait and Posture , vol.25 , Issue.3 , pp. 353-359
    • Begon, M.1    Monnet, T.2    Lacouture, P.3
  • 2
    • 0025353537 scopus 로고
    • A comparison of the accuracy of several hip center location prediction methods
    • DOI 10.1016/0021-9290(90)90054-7
    • Bell AL, Pedersen DR, Brand RA,. 1990. A comparison of the accuracy of several hip center location prediction methods. J Biomech 23: 617-621. (Pubitemid 20231020)
    • (1990) Journal of Biomechanics , vol.23 , Issue.6 , pp. 617-621
    • Bell, A.L.1    Pedersen, D.R.2    Brand, R.A.3
  • 4
    • 19644398653 scopus 로고    scopus 로고
    • Human movement analysis using stereophotogrammetry Part 3. Soft tissue artifact assessment and compensation
    • DOI 10.1016/j.gaitpost.2004.05.002
    • Leardini A, Chiari L, Croce UD, et al. 2005. Human movement analysis using stereophotogrammetry: part 3. Soft tissue artifact assessment and compensation. Gait Posture 21: 212-225. (Pubitemid 41556840)
    • (2005) Gait and Posture , vol.21 , Issue.2 , pp. 212-225
    • Leardini, A.1    Chiari, A.2    Della Croce, U.3    Cappozzo, A.4
  • 5
    • 28644437782 scopus 로고    scopus 로고
    • Clinical applicability of using spherical fitting to find hip joint centers
    • DOI 10.1016/j.gaitpost.2004.08.004, PII S0966636204001432
    • Hicks JL, Richards JG,. 2005. Clinical applicability of using spherical fitting to find hip joint centers. Gait Posture 22: 138-145. (Pubitemid 41749350)
    • (2005) Gait and Posture , vol.22 , Issue.2 , pp. 138-145
    • Hicks, J.L.1    Richards, J.G.2
  • 7
    • 73149124701 scopus 로고    scopus 로고
    • Quantification of soft tissue artifact in lower limb human motion analysis: A systematic review
    • Peters A, Galna B, Sangeux M, et al. 2010. Quantification of soft tissue artifact in lower limb human motion analysis: a systematic review. Gait Posture 31: 1-8.
    • (2010) Gait Posture , vol.31 , pp. 1-8
    • Peters, A.1    Galna, B.2    Sangeux, M.3
  • 9
    • 76349108519 scopus 로고    scopus 로고
    • Evaluation of formal methods in hip joint center assessment: An in vitro analysis
    • Lopomo N, Sun L, Zaffagnini S, et al. 2010. Evaluation of formal methods in hip joint center assessment: an in vitro analysis. Clin Biomech 25: 206-212.
    • (2010) Clin Biomech , vol.25 , pp. 206-212
    • Lopomo, N.1    Sun, L.2    Zaffagnini, S.3
  • 10
    • 67349180188 scopus 로고    scopus 로고
    • In-vitro experimental assessment of a new robust algorithm for hip joint centre estimation
    • De Momi E, Lopomo N, Cerveri P, et al. 2009. In-vitro experimental assessment of a new robust algorithm for hip joint centre estimation. J Biomech 42: 989-995.
    • (2009) J Biomech , vol.42 , pp. 989-995
    • De Momi, E.1    Lopomo, N.2    Cerveri, P.3
  • 11
    • 52049117399 scopus 로고    scopus 로고
    • A comparison of four functional methods to determine centers and axes of rotations
    • MacWilliams BA,. 2008. A comparison of four functional methods to determine centers and axes of rotations. Gait Posture 28: 673-679.
    • (2008) Gait Posture , vol.28 , pp. 673-679
    • MacWilliams, B.A.1
  • 12
    • 27744576452 scopus 로고    scopus 로고
    • Evaluation of a new algorithm to determine the hip joint center
    • DOI 10.1016/j.jbiomech.2004.10.032, PII S002192900400541X
    • Siston RA, Delp SL,. 2006. Evaluation of a new algorithm to determine the hip joint center. J Biomech 39: 125-130. (Pubitemid 41585017)
    • (2006) Journal of Biomechanics , vol.39 , Issue.1 , pp. 125-130
    • Siston, R.A.1    Delp, S.L.2
  • 13
    • 0742287079 scopus 로고    scopus 로고
    • Assessment of the functional method of hip joint center location subject to reduced range of hip motion
    • DOI 10.1016/S0021-9290(03)00288-4
    • Piazza SJ, Erdemir A, Okita N, et al. 2004. Assessment of the functional method of hip joint center location subject to reduced range of hip motion. J Biomech 37: 349-356. (Pubitemid 38156083)
    • (2004) Journal of Biomechanics , vol.37 , Issue.3 , pp. 349-356
    • Piazza, S.J.1    Erdemir, A.2    Okita, N.3    Cavanagh, P.R.4
  • 14
    • 80051545780 scopus 로고    scopus 로고
    • Subject-specific hip joint centre location affects the calculation of hip contact forces during gait
    • Lenaerts G, Smits T, Bartels W, et al. 2008. Subject-specific hip joint centre location affects the calculation of hip contact forces during gait. Gait Posture 28 (Supplement 2): S78-S79.
    • (2008) Gait Posture , vol.28 , Issue.SUPPLEMENT 2
    • Lenaerts, G.1    Smits, T.2    Bartels, W.3
  • 15
    • 33748304160 scopus 로고    scopus 로고
    • Effect of skin movement artifact on knee kinematics during gait and cutting motions measured in vivo
    • DOI 10.1016/j.gaitpost.2005.04.012, PII S0966636205001700
    • Benoit DL, Ramsey DK, Lamontagne M, et al. 2006. Effect of skin movement artifact on knee kinematics during gait and cutting motions measured in vivo. Gait Posture 24: 152-164. (Pubitemid 44332252)
    • (2006) Gait and Posture , vol.24 , Issue.2 , pp. 152-164
    • Benoit, D.L.1    Ramsey, D.K.2    Lamontagne, M.3    Xu, L.4    Wretenberg, P.5    Renstrom, P.6
  • 16
    • 0028500074 scopus 로고
    • Radiographic study of skin displacement errors in the foot and ankle during standing
    • DOI 10.1016/0268-0033(94)90041-8
    • Maslen BA, Ackland TR,. 1994. Radiographic study of skin displacement errors in the foot and ankle during standing. Clin Biomech 9: 291-296. (Pubitemid 24260290)
    • (1994) Clinical Biomechanics , vol.9 , Issue.5 , pp. 291-296
    • Maslen, B.A.1    Ackland, T.R.2
  • 17
    • 0031194416 scopus 로고    scopus 로고
    • Effect of skin movement on the analysis of skeletal knee joint motion during running
    • DOI 10.1016/S0021-9290(97)00001-8, PII S0021929097000018
    • Reinschmidt C, van den Bogert AJ, Nigg BM, et al. 1997. Effect of skin movement on the analysis of skeletal knee joint motion during running. J Biomech 30: 729-732. (Pubitemid 27309823)
    • (1997) Journal of Biomechanics , vol.30 , Issue.7 , pp. 729-732
    • Reinschmidt, C.1    Van Den Bogert, A.J.2    Nigg, B.M.3    Lundberg, A.4    Murphy, N.5
  • 18
    • 13844256386 scopus 로고    scopus 로고
    • Quantification of soft tissue artefact in motion analysis by combining 3D fluoroscopy and stereophotogrammetry: A study on two subjects
    • DOI 10.1016/j.clinbiomech.2004.11.012, PII S0268003304002839
    • Stagni R, Fantozzi S, Cappello A, et al. 2005. Quantification of soft tissue artefact in motion analysis by combining 3D fluoroscopy and stereophotogrammetry: a study on two subjects. Clin Biomech 20: 320-329. (Pubitemid 40247688)
    • (2005) Clinical Biomechanics , vol.20 , Issue.3 , pp. 320-329
    • Stagni, R.1    Fantozzi, S.2    Cappello, A.3    Leardini, A.4
  • 19
    • 33750362137 scopus 로고    scopus 로고
    • A survey of formal methods for determining the centre of rotation of ball joints
    • DOI 10.1016/j.jbiomech.2005.10.002, PII S002192900500446X
    • Ehrig RM, Taylor WR, Duda GN, et al. 2006. A survey of formal methods for determining the centre of rotation of ball joints. J Biomech 39: 2798-2809. (Pubitemid 44633045)
    • (2006) Journal of Biomechanics , vol.39 , Issue.15 , pp. 2798-2809
    • Ehrig, R.M.1    Taylor, W.R.2    Duda, G.N.3    Heller, M.O.4
  • 21
    • 21844468932 scopus 로고    scopus 로고
    • On the influence of soft tissue coverage in the determination of bone kinematics using skin markers
    • DOI 10.1016/j.orthres.2005.02.006, PII S0736026605000410
    • Taylor WR, Ehrig RM, Duda GN, et al. 2005. On the influence of soft tissue coverage in the determination of bone kinematics using skin markers. J Orthop Res 23 (4): 726-734. (Pubitemid 40960021)
    • (2005) Journal of Orthopaedic Research , vol.23 , Issue.4 , pp. 726-734
    • Taylor, W.R.1    Ehrig, R.M.2    Duda, G.N.3    Schell, H.4    Seebeck, P.5    Heller, M.O.6
  • 22
    • 77954656708 scopus 로고    scopus 로고
    • P041 a comparison of two functional methods for calculating joint centers and axes in a clinical setting
    • Rozumalski A, Schwartz MH,. 2008. P041 a comparison of two functional methods for calculating joint centers and axes in a clinical setting. Gait Posture 28 (Supplement 2): S74.
    • (2008) Gait Posture , vol.28 , Issue.SUPPLEMENT 2
    • Rozumalski, A.1    Schwartz, M.H.2
  • 23
    • 35448929927 scopus 로고    scopus 로고
    • Comparison of the SCoRE and HA methods for locating in vivo the glenohumeral joint centre
    • DOI 10.1016/j.jbiomech.2007.05.030, PII S0021929007002552
    • Monnet T, Desailly E, Begon M, et al. 2007. Comparison of the SCoRE and HA methods for locating in vivo the glenohumeral joint centre. J Biomech 40: 3487-3492. (Pubitemid 47632607)
    • (2007) Journal of Biomechanics , vol.40 , Issue.15 , pp. 3487-3492
    • Monnet, T.1    Desailly, E.2    Begon, M.3    Vallee, C.4    Lacouture, P.5
  • 24
    • 79954575991 scopus 로고    scopus 로고
    • The SCoRE residual: A quality index to assess the accuracy of joint estimations
    • Ehrig RM, Heller MO, Kratzenstein S, et al. 2011. The SCoRE residual: a quality index to assess the accuracy of joint estimations. J Biomech DOI: 10.1016/j.biomech.2010.12.009.
    • (2011) J Biomech
    • Ehrig, R.M.1    Heller, M.O.2    Kratzenstein, S.3
  • 25
    • 77954658716 scopus 로고    scopus 로고
    • Repeatability and reproducibility of OSSCA, a functional approach for assessing the kinematics of the lower limb
    • Taylor WR, Kornaropoulos EI, Duda GN, et al. 2010. Repeatability and reproducibility of OSSCA, a functional approach for assessing the kinematics of the lower limb. Gait Posture 32: 231-236.
    • (2010) Gait Posture , vol.32 , pp. 231-236
    • Taylor, W.R.1    Kornaropoulos, E.I.2    Duda, G.N.3
  • 26
    • 33645062669 scopus 로고    scopus 로고
    • An optimized protocol for hip joint centre determination using the functional method
    • Camomilla V, Cereatti A, Vannozzi G, et al. 2006. An optimized protocol for hip joint centre determination using the functional method. J Biomech 39 (6): 1096-1106.
    • (2006) J Biomech , vol.39 , Issue.6 , pp. 1096-1106
    • Camomilla, V.1    Cereatti, A.2    Vannozzi, G.3
  • 28
    • 74449088351 scopus 로고    scopus 로고
    • Frontal plane alignment: An imageless method to predict the mechanical femoral-tibial angle (mFTA) based on functional determination of joint centres and axes
    • Kornaropoulos EI, Taylor WR, Duda GN, et al. 2010. Frontal plane alignment: an imageless method to predict the mechanical femoral-tibial angle (mFTA) based on functional determination of joint centres and axes. Gait Posture 31: 204-208.
    • (2010) Gait Posture , vol.31 , pp. 204-208
    • Kornaropoulos, E.I.1    Taylor, W.R.2    Duda, G.N.3
  • 29
    • 0027897660 scopus 로고
    • Determining the movements of the skeleton using well-configured markers
    • DOI 10.1016/0021-9290(93)90098-Y
    • Söderkvist I, Wedin P-A,. 1993. Determining the movements of the skeleton using well-configured markers. J Biomech 26: 1473-1477. (Pubitemid 23348508)
    • (1993) Journal of Biomechanics , vol.26 , Issue.12 , pp. 1473-1477
    • Soderkkvist, I.1    Wedin, P.-A.2
  • 30
    • 0023819125 scopus 로고
    • A least-squares algorithm for the equiform transformation from spatial marker co-ordinates
    • DOI 10.1016/0021-9290(88)90190-X
    • Veldpaus F, Woltring H, Dortmans L,. 1988. A least-squares algorithm for the equiform transformation from spatial marker co-ordinates. J Biomech 21: 45-54. (Pubitemid 18546159)
    • (1988) Journal of Biomechanics , vol.21 , Issue.1 , pp. 45-54
    • Veldpaus, F.E.1    Woltring, H.J.2    Dortmans, L.J.M.G.3
  • 32
    • 34250884553 scopus 로고    scopus 로고
    • A survey of formal methods for determining functional joint axes
    • DOI 10.1016/j.jbiomech.2006.10.026, PII S0021929006004155
    • Ehrig RM, Taylor WR, Duda GN, et al. 2007. A survey of formal methods for determining functional joint axes. J Biomech 40: 2150-2157. (Pubitemid 46977411)
    • (2007) Journal of Biomechanics , vol.40 , Issue.10 , pp. 2150-2157
    • Ehrig, R.M.1    Taylor, W.R.2    Duda, G.N.3    Heller, M.O.4
  • 35
    • 37049004736 scopus 로고    scopus 로고
    • Influence of thigh cluster configuration on the estimation of hip axial rotation
    • DOI 10.1016/j.gaitpost.2007.01.002, PII S0966636207000288
    • Schache AG, Baker R, Lamoreux LW,. 2008. Influence of thigh cluster configuration on the estimation of hip axial rotation. Gait Posture 27: 60-69. (Pubitemid 350251205)
    • (2008) Gait and Posture , vol.27 , Issue.1 , pp. 60-69
    • Schache, A.G.1    Baker, R.2    Lamoreux, L.W.3
  • 36
    • 20444475413 scopus 로고    scopus 로고
    • Soft tissue artifact compensation in knee kinematics by double anatomical landmark calibration: Performance of a novel method during selected motor tasks
    • DOI 10.1109/TBME.2005.846728
    • Cappello A, Stagni R, Fantozzi S, et al. 2005. Soft tissue artifact compensation in knee kinematics by double anatomical landmark calibration: performance of a novel method during selected motor tasks. IEEE Trans Biomed Eng 52: 992-998. (Pubitemid 40813831)
    • (2005) IEEE Transactions on Biomedical Engineering , vol.52 , Issue.6 , pp. 992-998
    • Cappello, A.1    Stagni, R.2    Fantozzi, S.3    Leardini, A.4
  • 37
    • 57649228441 scopus 로고    scopus 로고
    • Double calibration vs. global optimisation: Performance and effectiveness for clinical application
    • Stagni R, Fantozzi S, Cappello A,. 2009. Double calibration vs. global optimisation: performance and effectiveness for clinical application. Gait Posture 29: 119-122.
    • (2009) Gait Posture , vol.29 , pp. 119-122
    • Stagni, R.1    Fantozzi, S.2    Cappello, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.