메뉴 건너뛰기




Volumn 56, Issue 8, 2011, Pages 1108-1114

Performance of the CoughAssist insufflation-exsufflation device in the presence of an endotracheal tube or tracheostomy tube: A bench study

Author keywords

Airway secretion clearance; Airways; Cough; Echanical ventilation; Endotracheal tube; Insufflator exsufflator; Intubation; Peak expiratory flow; Pef; Racheostomy

Indexed keywords

AIRWAY PRESSURE; AIRWAY RESISTANCE; ARTICLE; ARTIFICIAL VENTILATION; CLINICAL ASSESSMENT; CONTROLLED STUDY; COUGHING; ENDOTRACHEAL TUBE; IN VITRO STUDY; LUNG CLEARANCE; LUNG MODEL; PEAK EXPIRATORY FLOW; POSITIVE END EXPIRATORY PRESSURE; PRESSURE MEASUREMENT; QUALITY CONTROL; RESPIRATORY AIRFLOW; TRACHEOSTOMY; VENTILATOR;

EID: 80051502302     PISSN: 00201324     EISSN: 19433654     Source Type: Journal    
DOI: 10.4187/respcare.01121     Document Type: Article
Times cited : (52)

References (17)
  • 3
    • 0033594347 scopus 로고    scopus 로고
    • Practice parameter: The care of the patient with amyotrophic lateral sclerosis (an evidence-based review): Report of the Quality Standards Subcommittee of the American Academy of Neurology: ALS Practice Parameters Task Force
    • Miller RG, Rosenberg JA, Gelinas DF, Mitsumoto H, Newman D, Sufit R, et al. Practice parameter: the care of the patient with amyotrophic lateral sclerosis (an evidence-based review): report of the Quality Standards Subcommittee of the American Academy of Neurology: ALS Practice Parameters Task Force. Neurology 1999;52(7): 1311-1323.
    • (1999) Neurology , vol.52 , Issue.7 , pp. 1311-1323
    • Miller, R.G.1    Rosenberg, J.A.2    Gelinas, D.F.3    Mitsumoto, H.4    Newman, D.5    Sufit, R.6
  • 4
    • 12744277966 scopus 로고    scopus 로고
    • Mechanical insufflation-exsufflation improves outcomes for neuromuscular disease patients with respiratory tract infections
    • discussion 89-91
    • Vianello A, Corrado A, Arcaro G, Gallan F, Ori C, Minuzzo M, et al. Mechanical insufflation-exsufflation improves outcomes for neuromuscular disease patients with respiratory tract infections. Am J Phys Med Rehabil 2005;84(2):83-88, discussion 89-91.
    • (2005) Am J Phys Med Rehabil , vol.84 , Issue.2 , pp. 83-88
    • Vianello, A.1    Corrado, A.2    Arcaro, G.3    Gallan, F.4    Ori, C.5    Minuzzo, M.6
  • 5
    • 62149092640 scopus 로고    scopus 로고
    • The addition of mechanical insufflation/exsufflation shortens airway-clearance sessions in neuromuscular patients with chest infection
    • Chatwin M, Simonds AK. The addition of mechanical insufflation/exsufflation shortens airway-clearance sessions in neuromuscular patients with chest infection. Respir Care 2009;54(11):1473-1479.
    • (2009) Respir Care , vol.54 , Issue.11 , pp. 1473-1479
    • Chatwin, M.1    Simonds, A.K.2
  • 6
    • 38449104897 scopus 로고    scopus 로고
    • Mechanical insufflation-exsufflation for airway mucus clearance
    • discussion 1306-1307
    • Homnick DN. Mechanical insufflation-exsufflation for airway mucus clearance. Respir Care 2007;52(10):1296-1305, discussion 1306-1307.
    • (2007) Respir Care , vol.52 , Issue.10 , pp. 1296-1305
    • Homnick, D.N.1
  • 7
    • 0347579840 scopus 로고    scopus 로고
    • Cough augmentation with mechanical insufflation/exsufflation in patients with neuromuscular weakness
    • Chatwin M, Ross E, Hart N, Nickol AH, Polkey MI, Simonds AK. Cough augmentation with mechanical insufflation/exsufflation in patients with neuromuscular weakness. Eur Respir J 2003;21(3):502-508.
    • (2003) Eur Respir J , vol.21 , Issue.3 , pp. 502-508
    • Chatwin, M.1    Ross, E.2    Hart, N.3    Nickol, A.H.4    Polkey, M.I.5    Simonds, A.K.6
  • 9
    • 0018884094 scopus 로고
    • Resistance to breathing in healthy subjects following endotracheal intubation under topical anesthesia
    • Gal TJ, Suratt PM. Resistance to breathing in healthy subjects following endotracheal intubation under topical anesthesia. Anesth Analg 1980;59(4):270-274.
    • (1980) Anesth Analg , vol.59 , Issue.4 , pp. 270-274
    • Gal, T.J.1    Suratt, P.M.2
  • 10
    • 0022860737 scopus 로고
    • Work of breathing through different sized endotracheal tubes
    • Shapiro M, Wilson RK, Casar G, Bloom K, Teague RB. Work of breathing through different sized endotracheal tubes. Crit Care Med 1986;14(12):1028-1031.
    • (1986) Crit Care Med , vol.14 , Issue.12 , pp. 1028-1031
    • Shapiro, M.1    Wilson, R.K.2    Casar, G.3    Bloom, K.4    Teague, R.B.5
  • 11
    • 0018861582 scopus 로고
    • Effects of endotracheal intubation on normal cough performance
    • Gal TJ. Effects of endotracheal intubation on normal cough performance. Anesthesiology 1980;52(4):324-329.
    • (1980) Anesthesiology , vol.52 , Issue.4 , pp. 324-329
    • Gal, T.J.1
  • 12
    • 77950791801 scopus 로고    scopus 로고
    • Involuntary cough strength and extubation outcomes for patients in an ICU
    • Su WL, Chen YH, Chen CW, Yang SH, Su CL, Perng WC, et al. Involuntary cough strength and extubation outcomes for patients in an ICU. Chest 2010;137(4):777-782.
    • (2010) Chest , vol.137 , Issue.4 , pp. 777-782
    • Su, W.L.1    Chen, Y.H.2    Chen, C.W.3    Yang, S.H.4    Su, C.L.5    Perng, W.C.6
  • 13
    • 77951805051 scopus 로고    scopus 로고
    • Extubation of patients with neuromuscular weakness: A new management paradigm
    • Bach JR, Goncalves MR, Hamdani I, Winck JC. Extubation of patients with neuromuscular weakness: a new management paradigm. Chest 2010;137(5):1033-1039.
    • (2010) Chest , vol.137 , Issue.5 , pp. 1033-1039
    • Bach, J.R.1    Goncalves, M.R.2    Hamdani, I.3    Winck, J.C.4
  • 15
    • 0030793790 scopus 로고    scopus 로고
    • Prevention of pulmonary morbidity for patients with Duchenne muscular dystrophy
    • Bach JR, Ishikawa Y, Kim H. Prevention of pulmonary morbidity for patients with Duchenne muscular dystrophy. Chest 1997;112(4): 1024-1028.
    • (1997) Chest , vol.112 , Issue.4 , pp. 1024-1028
    • Bach, J.R.1    Ishikawa, Y.2    Kim, H.3
  • 16
    • 0036070653 scopus 로고    scopus 로고
    • Mechanical insufflation-exsufflation: Pressure, volume, and flow relationships and the adequacy of the manufacturer's guidelines
    • Gomez-Merino E, Sancho J, Marin J, Servera E, Blasco ML, Belda FJ, et al. Mechanical insufflation-exsufflation: pressure, volume, and flow relationships and the adequacy of the manufacturer's guidelines. Am J Phys Med Rehabil 2002;81(8):579-583.
    • (2002) Am J Phys Med Rehabil , vol.81 , Issue.8 , pp. 579-583
    • Gomez-Merino, E.1    Sancho, J.2    Marin, J.3    Servera, E.4    Blasco, M.L.5    Belda, F.J.6
  • 17
    • 0024394440 scopus 로고
    • In vitro versus in vivo comparison of endotracheal tube airflow resistance
    • Wright PE, Marini JJ, Bernard GR. In vitro versus in vivo comparison of endotracheal tube airflow resistance. Am Rev Respir Dis 1989;140(1):10-16.
    • (1989) Am Rev Respir Dis , vol.140 , Issue.1 , pp. 10-16
    • Wright, P.E.1    Marini, J.J.2    Bernard, G.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.