메뉴 건너뛰기




Volumn 18, Issue 4, 2011, Pages 196-205

GCL hydration under simulated daily thermal cycles

Author keywords

Geosynthetic clay liners (GCL); Geosynthetics; Hydration; Thermal cycles

Indexed keywords

FOUNDATIONS; GEOSYNTHETIC MATERIALS; GRADING; HYDRATION; MOISTURE; SAND; SHRINKAGE; SOILS; THERMAL CYCLING;

EID: 79961157846     PISSN: 10726349     EISSN: 17517613     Source Type: Journal    
DOI: 10.1680/gein.2011.18.4.196     Document Type: Article
Times cited : (56)

References (17)
  • 3
    • 77957360307 scopus 로고    scopus 로고
    • Properties of geosynthetics exhumed from a final cover at a solid waste landfill
    • Benson, C. H., Kucukkirca, I. E. & Scalia, J. (2010). Properties of geosynthetics exhumed from a final cover at a solid waste landfill. Geotextiles and Geomembranes,. 28,. No. 6, 536-546.
    • (2010) Geotextiles and Geomembranes , vol.28 , Issue.6 , pp. 536-546
    • Benson, C.H.1    Kucukkirca, I.E.2    Scalia, J.3
  • 6
    • 0000415074 scopus 로고
    • Effects of partial wetting on the performance of the bentonite component of a geosynthetic clay liner
    • March 30-April 1, Industrial Fabrics International Association, Roseville, MN, USA
    • Daniel, D. E., Shan, H. Y. & Anderson, J. D. (1993). Effects of partial wetting on the performance of the bentonite component of a geosynthetic clay liner. Proceedings of Geosynthetics '93, Vancouver, B.C., March 30-April 1, Industrial Fabrics International Association, Roseville, MN, USA, pp. 1483-1496.
    • (1993) Proceedings of Geosynthetics '93, Vancouver, B.C. , pp. 1483-1496
    • Daniel, D.E.1    Shan, H.Y.2    Anderson, J.D.3
  • 7
    • 17044364145 scopus 로고    scopus 로고
    • Measuring the in-situ moisture content of geosynthetic clay liners (GCLs) using time domain reflectometry (tdr)
    • Industrial Fabrics International Association, Roseville, MN, USA
    • Eberle, M. A. & von Maubeuge, K. (1997). Measuring the in-situ moisture content of geosynthetic clay liners (GCLs) using time domain reflectometry (tdr). 6th International Conference on Geosynthetics,. Industrial Fabrics International Association, Roseville, MN, USA, Vol. 1, pp. 205-210.
    • (1997) 6th International Conference on Geosynthetics , vol.1 , pp. 205-210
    • Eberle, M.A.1    von Maubeuge, K.2
  • 8
    • 79961151923 scopus 로고    scopus 로고
    • Geo-Slope International Ltd, build 4840, Geo-Slope International Ltd, Calgary, Alberta, Canada
    • Geo-Slope International Ltd (2007). GeoStudio,. version 7, build 4840, Geo-Slope International Ltd, Calgary, Alberta, Canada.
    • (2007) GeoStudio, version 7
  • 9
    • 0343618386 scopus 로고    scopus 로고
    • Swelling characteristics of needlepunched, thermally treated GCLs
    • Lake, C. B. & Rowe, R. K. (2000). Swelling characteristics of needlepunched, thermally treated GCLs. Geotextiles and Geomembranes,. 18,. No. 2, 77-102.
    • (2000) Geotextiles and Geomembranes , vol.18 , Issue.2 , pp. 77-102
    • Lake, C.B.1    Rowe, R.K.2
  • 10
    • 0031393249 scopus 로고    scopus 로고
    • Geosynthetic clay liner compatability by hydraulic conductivity testing: Factors impacting performance
    • Petrov, R. J. & Rowe, R. K. (1997). Geosynthetic clay liner compatability by hydraulic conductivity testing: Factors impacting performance. Canadian Geotechnical Journal,. 34,. No. 6, 863-885.
    • (1997) Canadian Geotechnical Journal , vol.34 , Issue.6 , pp. 863-885
    • Petrov, R.J.1    Rowe, R.K.2
  • 13
    • 77952289720 scopus 로고    scopus 로고
    • Shrinkage characteristics of heat-tacked GCL seams
    • Rowe, R. K., Bostwick, L. E. & Thiel, R. (2010). Shrinkage characteristics of heat-tacked GCL seams. Geotextiles and Geomembranes,. 28,. No. 4, 352-359.
    • (2010) Geotextiles and Geomembranes , vol.28 , Issue.4 , pp. 352-359
    • Rowe, R.K.1    Bostwick, L.E.2    Thiel, R.3
  • 15
    • 0012977021 scopus 로고    scopus 로고
    • Time domain reflectometry development for use in geotechnical engineering
    • Siddiqui, S. I., Drnevich, V. P. & Deschamps, R. J. (2000). Time domain reflectometry development for use in geotechnical engineering. Geotechnical Testing Journal,. 23,. No. 1, 9-20.
    • (2000) Geotechnical Testing Journal , vol.23 , Issue.1 , pp. 9-20
    • Siddiqui, S.I.1    Drnevich, V.P.2    Deschamps, R.J.3
  • 16
    • 34249042858 scopus 로고    scopus 로고
    • Concern for GCL shrinkage when installed on slopes
    • GII Publications, Folsom, PA, USA paper 2.31
    • Thiel, R. & Richardson, G. (2005). Concern for GCL shrinkage when installed on slopes. JGRI-18 at GeoFrontiers,. GII Publications, Folsom, PA, USA paper 2.31.
    • (2005) JGRI-18 at GeoFrontiers
    • Thiel, R.1    Richardson, G.2
  • 17
    • 69949179598 scopus 로고    scopus 로고
    • Laboratory measurements of GCL shrinkage under cyclic changes in temperature and hydration conditions. In
    • Kuwano, J. & Koseki, J., Editors, IOS Press, Amsterdam, the Netherlands
    • Thiel, R., Giroud, J. P., Erickson, R., Criley, K. & Bryk, J. (2006). Laboratory measurements of GCL shrinkage under cyclic changes in temperature and hydration conditions. In Geosynthetics: 8th International Conference on Geosynthetics,. Kuwano, J. & Koseki, J., Editors, IOS Press, Amsterdam, the Netherlands, Vol. 1, pp. 21-44.
    • (2006) Geosynthetics: 8th International Conference on Geosynthetics , vol.1 , pp. 21-44
    • Thiel, R.1    Giroud, J.P.2    Erickson, R.3    Criley, K.4    Bryk, J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.