Volumn 81, Issue 1, 2011, Pages 85-90

High retention and safety of percutaneously implanted endovascular embolization coils as fiducial markers for image-guided stereotactic ablative radiotherapy of pulmonary tumors

Author keywords

Endovascular embolization coils; Gold seed fiducial markers; Image guided radiation therapy (IGRT); Implanted fiducial markers; Stereotactic ablative radiotherapy (SABR); Stereotactic body radiotherapy (SBRT)

Indexed keywords

EMBOLIZATION; FIDUCIAL MARKER; GOLD SEEDS; IMAGE-GUIDED RADIATION THERAPY (IGRT); STEREOTACTIC ABLATIVE RADIOTHERAPY (SABR); STEREOTACTIC BODY RADIOTHERAPY;

EID: 79961126603     PISSN: 03603016     EISSN: 1879355X     Source Type: Journal    
DOI: 10.1016/j.ijrobp.2010.04.037     Document Type: Article
Times cited : (32)

References (10)
  • 1
    • 0027183908 scopus 로고
    • Computer-assisted positioning of radiotherapy patients using implanted radiopaque fiducials
    • DOI 10.1118/1.596969
    • K.P. Gall, L.J. Verhey, and M. Wagner Computer-assisted positioning of radiotherapy patients using implanted radiopaque fiducials Med Phys 20 1993 1153 1159 (Pubitemid 23249863)
    • (1993) Medical Physics , vol.20 , Issue.4 , pp. 1153-1159
    • Gall, K.P.1    Verhey, L.J.2    Wagner, M.3
  • 3
    • 0033824313 scopus 로고    scopus 로고
    • Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor
    • H. Shirato, S. Shimizu, and K. Kitamura Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor Int J Radiat Oncol Biol Phys 48 2000 435 442
    • (2000) Int J Radiat Oncol Biol Phys , vol.48 , pp. 435-442
    • Shirato, H.1    Shimizu, S.2    Kitamura, K.3
  • 4
    • 0033743945 scopus 로고    scopus 로고
    • Robotic motion compensation for respiratory movement during radiosurgery
    • A. Schweikard, G. Glosser, and M. Bodduluri Robotic motion compensation for respiratory movement during radiosurgery Comput Aided Surg 5 2000 263 277
    • (2000) Comput Aided Surg , vol.5 , pp. 263-277
    • Schweikard, A.1    Glosser, G.2    Bodduluri, M.3
  • 5
    • 7244242297 scopus 로고    scopus 로고
    • Respiration tracking in radiosurgery
    • DOI 10.1118/1.1774132
    • A. Schweikard, H. Shiomi, and J. Adler Respiration tracking in radiosurgery Med Phys 31 2004 2738 2741 (Pubitemid 39430998)
    • (2004) Medical Physics , vol.31 , Issue.10 , pp. 2738-2741
    • Schweikard, A.1    Shiomi, H.2    Adler, J.3
  • 6
    • 58249126445 scopus 로고    scopus 로고
    • Safety and efficacy of percutaneous fiducial marker implantation for image-guided radiation therapy
    • N. Kothary, J.J. Heit, and J.D. Louie Safety and efficacy of percutaneous fiducial marker implantation for image-guided radiation therapy J Vasc Interv Radiol 20 2 2009 235 239
    • (2009) J Vasc Interv Radiol , vol.20 , Issue.2 , pp. 235-239
    • Kothary, N.1    Heit, J.J.2    Louie, J.D.3
  • 9
    • 48949116232 scopus 로고    scopus 로고
    • Endovascular coils as lung tumour markers in real-time tumour tracking stereotactic radiotherapy: Preliminary results
    • J.-B. Prevost, J.J. Nuyttens, and M.S. Hoogeman Endovascular coils as lung tumour markers in real-time tumour tracking stereotactic radiotherapy: Preliminary results Eur Radiol 18 2008 1569 1576
    • (2008) Eur Radiol , vol.18 , pp. 1569-1576
    • Prevost, J.-B.1    Nuyttens, J.J.2    Hoogeman, M.S.3
  • 10
    • 72449201655 scopus 로고    scopus 로고
    • Cardiac embolization of an implanted fiducial marker for hepatic stereotactic body radiotherapy: A case report
    • H. Hennessey, D. Valenti, and T. Cabrera Cardiac embolization of an implanted fiducial marker for hepatic stereotactic body radiotherapy: a case report J Med Case Reports 3 2009 140 144
    • (2009) J Med Case Reports , vol.3 , pp. 140-144
    • Hennessey, H.1    Valenti, D.2    Cabrera, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.