메뉴 건너뛰기




Volumn 9, Issue , 2011, Pages 281-287

A CMOS integrated impedance-to-frequency converter for sensing cellular adhesion

Author keywords

[No Author keywords available]

Indexed keywords


EID: 79961064101     PISSN: 16849965     EISSN: 16849973     Source Type: Journal    
DOI: 10.5194/ars-9-281-2011     Document Type: Article
Times cited : (3)

References (9)
  • 1
    • 0042045214 scopus 로고    scopus 로고
    • Whole cell biosensors
    • PII S0925400596019065
    • Bousse, L.: Whole cell biosensors, Sensors and Actuators B, 34, 270-275, doi:10.1016/S0925-4005(96)01906-5, 1996. (Pubitemid 126379872)
    • (1996) Sensors and Actuators, B: Chemical , vol.34 , Issue.1-3 , pp. 270-275
    • Bousse, L.1
  • 2
    • 0000529703 scopus 로고    scopus 로고
    • Fluorescence interferometry of neuronal cell adhesion on microstructured silicon
    • doi:10.1103/PhysRevLett.81.5241
    • Braun, D. and Fromherz, P.: Fluorescence Interferometry of Neuronal Cell Adhesion on Microstructured Silicon, Physical Review Letters, 81, 5241, doi:10.1103/PhysRevLett.81.5241, 1998.
    • (1998) Physical Review Letters , vol.81 , pp. 5241
    • Braun, D.1    Fromherz, P.2
  • 3
    • 0031060703 scopus 로고    scopus 로고
    • Monitoring of cellular behaviour by impedance measurements on interdigitated electrode structures
    • DOI 10.1016/0956-5663(96)89087-7
    • Ehret, R., Baumann, W., Brischwein, M., Schwinde, A., Stegbauer, K., andWolf, B.: Monitoring of cellular behaviour by impedance measurements on interdigitated electrode structures, Biosensors and Bioelectronics, 12, 29-41, doi:10.1016/0956-5663(96) 89087-7, 1997. (Pubitemid 26398077)
    • (1997) Biosensors and Bioelectronics , vol.12 , Issue.1 , pp. 29-41
    • Ehret, R.1    Baumann, W.2    Brischwein, M.3    Schwinde, A.4    Stegbauer, K.5    Wolf, B.6
  • 4
    • 21844466991 scopus 로고    scopus 로고
    • Impedance characterization and modeling of electrodes for biomedical applications
    • DOI 10.1109/TBME.2005.847523
    • Franks, W., Schenker, I., Schmutz, P., and Hierlemann, A.: Impedance characterization and modeling of electrodes for biomedical applications, Biomedical Engineering, IEEE Transactions on, 52, 1295-1302, doi:10.1109/TBME.2005.847523, 2005. (Pubitemid 40961380)
    • (2005) IEEE Transactions on Biomedical Engineering , vol.52 , Issue.7 , pp. 1295-1302
    • Franks, W.1    Schenker, I.2    Schmutz, P.3    Hierlemann, A.4
  • 5
    • 0028823011 scopus 로고
    • Impedance analysis of MDCK cells measured by electric cell-substrate impedance sensing
    • Lo, C. M., Keese, C. R., and Giaever, I.: Impedance analysis of MDCK cells measured by electric cell-substrate impedance sensing., Biophys. J., 69, 2800-2807, 1995.
    • (1995) Biophys. J. , vol.69 , pp. 2800-2807
    • Lo, C.M.1    Keese, C.R.2    Giaever, I.3
  • 6
    • 0025752809 scopus 로고
    • The polarization impedance of common electrode metals operated at low current density
    • doi:10.1007/ BF02368466
    • Ragheb, T. and Geddes, L.: The polarization impedance of common electrode metals operated at low current density, Annals of Biomedical Engineering, 19, 151-163, doi:10.1007/ BF02368466, 1991.
    • (1991) Annals of Biomedical Engineering , vol.19 , pp. 151-163
    • Ragheb, T.1    Geddes, L.2
  • 7
    • 0025027938 scopus 로고
    • Determination of cell membrane resistance in cultured renal epithelioid (MDCK) cells: Effects of cadmium and mercury ions
    • Ritter, M., Lang, F., Grübl, G., and Embacher, H. G.: Determination of cell membrane resistance in cultured renal epithelioid (MDCK) cells: effects of cadmium and mercury ions, Pflügers Archiv European Journal of Physiology, 417, 29-36, doi:10.1007/BF00370765, 1990. (Pubitemid 20330115)
    • (1990) Pflugers Archiv European Journal of Physiology , vol.417 , Issue.1 , pp. 29-36
    • Ritter, M.1    Lang, F.2
  • 8
    • 33749666025 scopus 로고    scopus 로고
    • Impedance analysis of cultured cells: A mean-field electrical response model for electric cell-substrate impedance sensing technique
    • DOI 10.1103/PhysRevE.74.041908
    • Urdapilleta, E., Bellotti, M., and Bonetto, F. J.: Impedance analysis of cultured cells: A mean-field electrical response model for electric cell-substrate impedance sensing technique, Physical Review E (Statistical, Nonlinear, and Soft Matter Physics), 74, 041908-11, doi:10.1103/PhysRevE.74. 041908, 2006. (Pubitemid 44555552)
    • (2006) Physical Review E - Statistical, Nonlinear, and Soft Matter Physics , vol.74 , Issue.4 , pp. 041908
    • Urdapilleta, E.1    Bellotti, M.2    Bonetto, F.J.3
  • 9
    • 0034714440 scopus 로고    scopus 로고
    • Electric cell-substrate impedance sensing (ECIS) as a noninvasive means to monitor the kinetics of cell spreading to artificial surfaces
    • doi:10.1006/excr.2000.4919
    • Wegener, J., Keese, C. R., and Giaever, I.: Electric Cell-Substrate Impedance Sensing (ECIS) as a Noninvasive Means to Monitor the Kinetics of Cell Spreading to Artificial Surfaces, Experimental Cell Research, 259, 158-166, doi:10.1006/excr.2000.4919, 2000.
    • (2000) Experimental Cell Research , vol.259 , pp. 158-166
    • Wegener, J.1    Keese, C.R.2    Giaever, I.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.