메뉴 건너뛰기




Volumn 37, Issue 7, 2011, Pages 1174-1181

A new method for continuous monitoring of chest wall movement to characterize hypoxemic episodes during HFOV

Author keywords

Chest wall displacement; Continuous monitoring; Early detection; High frequency oscillatory ventilation; Mechanical ventilation; Respiratory distress syndrome

Indexed keywords

AIRWAY OBSTRUCTION; ARTICLE; ARTIFICIAL VENTILATION; CLINICAL ARTICLE; CLINICAL TRIAL; DISEASE SEVERITY; FEMALE; FOLLOW UP; HEART RATE; HIGH FREQUENCY OSCILLATORY VENTILATION; HUMAN; HYPOXEMIA; HYPOXIA; INFANT; LUNG COMPLIANCE; LUNG DYSPLASIA; MALE; MEAN ARTERIAL PRESSURE; MOVEMENT (PHYSIOLOGY); NEWBORN APNEA; NEWBORN MONITORING; PREMATURITY; PULSE OXIMETRY; RESPIRATORY DISTRESS SYNDROME; RESPIRATORY FAILURE; SEPSIS; THORAX WALL; TIDAL VOLUME;

EID: 79961023127     PISSN: 03424642     EISSN: 14321238     Source Type: Journal    
DOI: 10.1007/s00134-011-2228-y     Document Type: Article
Times cited : (7)

References (28)
  • 1
    • 42249089911 scopus 로고    scopus 로고
    • Management and outcomes of very low birth weight
    • DOI 10.1056/NEJMra0707601
    • EC Eichenwald AR Stark 2008 Management and outcomes of very low birth weight N Engl J Med 358 1700 1711 18420502 10.1056/NEJMra0707601 1:CAS:528:DC%2BD1cXksl2gsr4%3D (Pubitemid 351549917)
    • (2008) New England Journal of Medicine , vol.358 , Issue.16
    • Eichenwald, E.C.1    Stark, A.R.2
  • 2
    • 33745949739 scopus 로고    scopus 로고
    • Ventilatory Strategies in the Prevention and Management of Bronchopulmonary Dysplasia
    • DOI 10.1053/j.semperi.2006.05.006, PII S0146000506000711, BPD: State of Art
    • N Ambalavanan WA Carlo 2006 Ventilatory strategies in the prevention and management of bronchopulmonary dysplasia Semin Perinatol 30 192 199 16860159 10.1053/j.semperi.2006.05.006 (Pubitemid 44062677)
    • (2006) Seminars in Perinatology , vol.30 , Issue.4 , pp. 192-199
    • Ambalavanan, N.1    Carlo, W.A.2
  • 3
    • 33947595188 scopus 로고    scopus 로고
    • Matching Ventilatory Support Strategies to Respiratory Pathophysiology
    • DOI 10.1016/j.clp.2006.12.003, PII S0095510806001059, Surfactant and Mechanical Ventilation
    • A Greenough SM Donn 2007 Matching ventilatory support strategies to respiratory pathophysiology Clin Perinatol 34 35 53 17394929 10.1016/j.clp.2006.12.003 (Pubitemid 46476805)
    • (2007) Clinics in Perinatology , vol.34 , Issue.1 , pp. 35-53
    • Greenough, A.1    Donn, S.M.2
  • 4
    • 33947495802 scopus 로고    scopus 로고
    • The Role of High-Frequency Ventilation in Neonates: Evidence-Based Recommendations
    • DOI 10.1016/j.clp.2006.12.004, PII S0095510806001060, Surfactant and Mechanical Ventilation
    • AL Lampland MC Mammel 2007 The role of high-frequency ventilation in neonates: evidence-based recommendations Clin Perinatol 34 129 144 17394935 10.1016/j.clp.2006.12.004 (Pubitemid 46466908)
    • (2007) Clinics in Perinatology , vol.34 , Issue.1 , pp. 129-144
    • Lampland, A.L.1    Mammel, M.C.2
  • 5
    • 30644475236 scopus 로고    scopus 로고
    • Effects of volume-targeted synchronized intermittent mandatory ventilation on spontaneous episodes of hypoxemia in preterm infants
    • DOI 10.1159/000088198
    • V Polimeni N Claure C D'Ugard E Bancalari 2006 Effects of volume-targeted synchronized intermittent mandatory ventilation on spontaneous episodes of hypoxemia in preterm infants Biol Neonate 89 50 55 16155386 10.1159/000088198 (Pubitemid 43087508)
    • (2006) Biology of the Neonate , vol.89 , Issue.1 , pp. 50-55
    • Polimeni, V.1    Claure, N.2    D'Ugard, C.3    Bancalari, E.4
  • 6
    • 0038074296 scopus 로고    scopus 로고
    • Risk factors for intraventricular hemorrhage in very low birth weight premature infants: A retrospective case-control study
    • 12728115 10.1542/peds.111.5.e590
    • N Linder O Haskin 2003 Risk factors for intraventricular hemorrhage in very low birth weight premature infants: a retrospective case-control study Pediatrics 111 e590 e595 12728115 10.1542/peds.111.5.e590
    • (2003) Pediatrics , vol.111
    • Linder, N.1    Haskin, O.2
  • 7
    • 0031594485 scopus 로고    scopus 로고
    • 2 levels, and neurodevelopmental sequelae following assisted ventilation
    • CM Gammon TE Wiswell AR Spitzer 1998 Volutrauma, PaCO2 levels, and neuro-developmental sequelae following assisted ventilation Clin Perinatol 25 159 175 (Pubitemid 28110366)
    • (1998) Clinics in Perinatology , vol.25 , Issue.1 , pp. 159-175
    • Gannon, C.M.1    Wiswell, T.E.2    Spitzer, A.R.3
  • 8
    • 0036632422 scopus 로고    scopus 로고
    • Intensive care monitoring: Past, present and future
    • 12195865
    • N McIntosh 2002 Intensive care monitoring: past, present and future Clin Med 2 349 355 12195865
    • (2002) Clin Med , vol.2 , pp. 349-355
    • McIntosh, N.1
  • 9
    • 0033875199 scopus 로고    scopus 로고
    • Clinical diagnosis of pneumothorax is late: Use of trend data and decision support might allow preclinical detection
    • N McIntosh JC Becher S Cunningham B Stenson IA Laing AJ Lyon P Badger 2000 Clinical diagnosis of pneumothorax is late: use of trend data and decision support might allow preclinical detection Pediatr Res 48 408 415 10960511 10.1203/00006450-200009000-00025 1:STN:280:DC%2BD3M7ht1SqsA%3D%3D (Pubitemid 30637346)
    • (2000) Pediatric Research , vol.48 , Issue.3 , pp. 408-415
    • McIntosh, N.1    Becher, J.-C.2    Cunningham, S.3    Stenson, B.4    Laing, I.A.5    Lyon, A.J.6    Badger, P.7
  • 10
    • 0035512275 scopus 로고    scopus 로고
    • Events before the diagnosis of a pneumothorax in ventilated neonates
    • 11668164 10.1136/fn.85.3.F201 1:STN:280:DC%2BD3MrmsV2qsg%3D%3D
    • M Watkinson I Tiron 2001 Events before the diagnosis of a pneumothorax in ventilated neonates Arch Dis Child Fetal Neonatal Ed 85 F201 F203 11668164 10.1136/fn.85.3.F201 1:STN:280:DC%2BD3MrmsV2qsg%3D%3D
    • (2001) Arch Dis Child Fetal Neonatal Ed , vol.85
    • Watkinson, M.1    Tiron, I.2
  • 12
    • 0034025720 scopus 로고    scopus 로고
    • Comprehensive critical incident monitoring in a neonatal-pediatric intensive care unit: Experience with the system approach
    • B Frey B Kehrer M Losa H Braun L Berweger J Micallef M Ebenberger 2000 Comprehensive critical incident monitoring in a neonatal-pediatric intensive care unit: experience with the system approach Intensive Care Med 26 69 74 10663283 10.1007/s001340050014 1:STN:280:DC%2BD3c7jtVagsw%3D%3D (Pubitemid 30184463)
    • (2000) Intensive Care Medicine , vol.26 , Issue.1 , pp. 69-74
    • Frey, B.1    Kehrer, B.2    Losa, M.3    Braun, H.4    Berweger, L.5    Micallef, J.6    Ebenberger, M.7
  • 13
    • 0027380416 scopus 로고
    • Problems related to the endotracheal tube: An analysis of 2000 incident reports
    • SM Szekely RK Webb JA Williamson WJ Russell 1993 The Australian incident monitoring study. Problems related to the endotracheal tube: an analysis of 2,000 incident reports Anaesth Intensive Care 21 611 616 8273884 1:STN:280:DyaK2c%2FpvFCltA%3D%3D (Pubitemid 23311292)
    • (1993) Anaesthesia and Intensive Care , vol.21 , Issue.5 , pp. 611-616
    • Szekely, S.M.1    Webb, R.K.2    Williamson, J.A.3    Russell, W.J.4
  • 14
    • 14944358229 scopus 로고    scopus 로고
    • Nursing and infection-control issues during high-frequency oscillatory ventilation
    • DOI 10.1097/01.CCM.0000155918.29268.84
    • AM Sweeney J Lyle ND Ferguson 2005 Nursing and infection-control issues during high-frequency oscillatory ventilation Crit Care Med 33 S204 S208 15753729 10.1097/01.CCM.0000155918.29268.84 (Pubitemid 40365610)
    • (2005) Critical Care Medicine , vol.33 , Issue.3 SUPPL.
    • Sweeney, A.-M.1    Lyle, J.2    Ferguson, N.D.3
  • 15
    • 63649136958 scopus 로고    scopus 로고
    • State of the art in conventional mechanical ventilation
    • 10.1038/jp.2009.11 1:STN:280:DC%2BD1M3jsFersQ%3D%3D
    • M Keszler 2009 State of the art in conventional mechanical ventilation J Perinatology 29 262 275 10.1038/jp.2009.11 1:STN:280:DC%2BD1M3jsFersQ%3D%3D
    • (2009) J Perinatology , vol.29 , pp. 262-275
    • Keszler, M.1
  • 16
    • 17944376360 scopus 로고    scopus 로고
    • High-Frequency oscillatory ventilation: "please do not forget me", said the stethoscope
    • 10.1542/peds.108.3.819 1:STN:280:DC%2BD3MvpvFKrsA%3D%3D
    • D Waisman Z Weintraub A Rotschild O Davkin I Kessel Y Bental 2001 High-Frequency oscillatory ventilation: "Please do not forget me", said the stethoscope Pediatrics (letter) 108 819 10.1542/peds.108.3.819 1:STN:280:DC%2BD3MvpvFKrsA%3D%3D
    • (2001) Pediatrics (Letter) , vol.108 , pp. 819
    • Waisman, D.1    Weintraub, Z.2    Rotschild, A.3    Davkin, O.4    Kessel, I.5    Bental, Y.6
  • 17
    • 0036707841 scopus 로고    scopus 로고
    • Volume-dependent variations of regional lung sound, amplitude, and phase
    • H Kiyokawa H Pasterkamp 2002 Volume-dependent variations of regional lung sound, amplitude, and phase J Appl Physiol 93 1030 1038 12183500 (Pubitemid 34919677)
    • (2002) Journal of Applied Physiology , vol.93 , Issue.3 , pp. 1030-1038
    • Kiyokawa, H.1    Pasterkamp, H.2
  • 18
    • 0033834327 scopus 로고    scopus 로고
    • The relationship between normal lung sounds, age, and gender
    • 10988103 1:STN:280:DC%2BD3cvotFamtw%3D%3D
    • V Gross A Dittmar T Penzel F Schüttler P von Wichert 2000 The relationship between normal lung sounds, age, and gender Am J Respir Crit Care Med 162 905 909 10988103 1:STN:280:DC%2BD3cvotFamtw%3D%3D
    • (2000) Am J Respir Crit Care Med , vol.162 , pp. 905-909
    • Gross, V.1    Dittmar, A.2    Penzel, T.3    Schüttler, F.4    Von Wichert, P.5
  • 19
    • 33746770460 scopus 로고    scopus 로고
    • Comparison of lung sound transducers using a bioacoustic transducer testing system
    • DOI 10.1152/japplphysiol.00273.2006
    • SS Kraman GR Wodicka GA Pressler H Pasterkamp 2006 Comparison of lung sound transducers using a bioacoustic transducer testing system J Appl Physiol 101 469 476 16627681 10.1152/japplphysiol.00273.2006 (Pubitemid 44162355)
    • (2006) Journal of Applied Physiology , vol.101 , Issue.2 , pp. 469-476
    • Kraman, S.S.1    Wodicka, G.R.2    Pressler, G.A.3    Pasterkamp, H.4
  • 20
    • 33746606062 scopus 로고    scopus 로고
    • Design, construction, and evaluation of a BioAcoustic Transducer Testing (BATT) system for respiratory sounds
    • DOI 10.1109/TBME.2006.873696, 1658169
    • SS Kraman GA Pressler H Pasterkamp GR Wodicka 2006 Design, construction, and evaluation of a bioacoustic transducer testing (BATT) system for respiratory sounds IEEE Trans Biomed Eng 53 1711 1715 16916109 10.1109/TBME.2006.873696 (Pubitemid 44150286)
    • (2006) IEEE Transactions on Biomedical Engineering , vol.53 , Issue.8 , pp. 1711-1715
    • Kraman, S.S.1    Pressler, G.A.2    Pasterkamp, H.3    Wodicka, G.R.4
  • 21
    • 33645280587 scopus 로고    scopus 로고
    • Lung function tests in neonates and infants with chronic lung disease: Lung and chest-wall mechanics
    • 16493664 10.1002/ppul.20380
    • M Gappa JJ Pillow J Allen O Mayer J Stocks 2006 Lung function tests in neonates and infants with chronic lung disease: lung and chest-wall mechanics Pediatr Pulmonol 41 291 317 16493664 10.1002/ppul.20380
    • (2006) Pediatr Pulmonol , vol.41 , pp. 291-317
    • Gappa, M.1    Pillow, J.J.2    Allen, J.3    Mayer, O.4    Stocks, J.5
  • 23
    • 0033391795 scopus 로고    scopus 로고
    • A new sensor for monitoring chest wall motion during high-frequency oscillatory ventilation
    • DOI 10.1016/S1350-4533(99)00094-6, PII S1350453399000946
    • C Davis A Mazzolini J Mills P Dargaville 1999 A new sensor for monitoring chest wall motion during high-frequency oscillatory ventilation Med Eng Phys 21 619 623 10699564 10.1016/S1350-4533(99)00094-6 1:STN:280:DC%2BD3c7msFaguw%3D%3D (Pubitemid 30103663)
    • (1999) Medical Engineering and Physics , vol.21 , Issue.9 , pp. 619-623
    • Davis, C.1    Mazzolini, A.2    Mills, J.3    Dargaville, P.4
  • 24
    • 33846047025 scopus 로고    scopus 로고
    • Electrical impedance tomography in extremely prematurely born infants and during high frequency oscillatory ventilation analyzed in the frequency domain
    • DOI 10.1088/0967-3334/27/11/008, PII S0967333406264736
    • S Dunlop J Hough T Riedel JF Fraser K Dunster A Schibler 2006 Electrical impedance tomography in extremely prematurely born infants and during high frequency oscillatory ventilation analyzed in the frequency domain Physiol Meas 27 1151 1165 17028408 10.1088/0967-3334/27/11/008 (Pubitemid 46063741)
    • (2006) Physiological Measurement , vol.27 , Issue.11 , pp. 008
    • Dunlop, S.1    Hough, J.2    Riedel, T.3    Fraser, J.F.4    Dunster, K.5    Schibler, A.6
  • 25
    • 72449148665 scopus 로고    scopus 로고
    • Measurement of end-expiratory lung volume in intubated children without interruption of mechanical ventilation
    • 19626312 10.1007/s00134-009-1579-0
    • IG Bikker TV Scohy AdJ JC Bogers J Bakker D Gommers 2009 Measurement of end-expiratory lung volume in intubated children without interruption of mechanical ventilation Intensive Care Med 35 1749 1753 19626312 10.1007/s00134-009-1579-0
    • (2009) Intensive Care Med , vol.35 , pp. 1749-1753
    • Bikker, I.G.1    Scohy, T.V.2    Bogers Adj, J.C.3    Bakker, J.4    Gommers, D.5
  • 26
    • 73949116537 scopus 로고    scopus 로고
    • Evaluation of an electrical impedance tomography-based Global Inhomogeneity Index for pulmonary ventilation distribution
    • 19652949 10.1007/s00134-009-1589-y
    • Z Zhao K Möller D Steinmann I Frerichs J Guttmann 2009 Evaluation of an electrical impedance tomography-based Global Inhomogeneity Index for pulmonary ventilation distribution Intensive Care Med 35 1900 1906 19652949 10.1007/s00134-009-1589-y
    • (2009) Intensive Care Med , vol.35 , pp. 1900-1906
    • Zhao, Z.1    Möller, K.2    Steinmann, D.3    Frerichs, I.4    Guttmann, J.5
  • 27
    • 38049170915 scopus 로고    scopus 로고
    • Assessment of neonatal ventilation during high-frequency oscillatory ventilation
    • 18477922 10.1097/01.PCC.0000298637.74514.54
    • WJ Sturtz SM Touch RG Locke JS Greenspan TH Shaffer 2008 Assessment of neonatal ventilation during high-frequency oscillatory ventilation Pediatr Crit Care Med 9 101 104 18477922 10.1097/01.PCC.0000298637.74514.54
    • (2008) Pediatr Crit Care Med , vol.9 , pp. 101-104
    • Sturtz, W.J.1    Touch, S.M.2    Locke, R.G.3    Greenspan, J.S.4    Shaffer, T.H.5
  • 28
    • 33646355677 scopus 로고    scopus 로고
    • Expired tidal volumes measured by hot-wire anemometer during high-frequency oscillation in preterm infants
    • DOI 10.1002/ppul.20367
    • M Zimová-Herknerová R Plavka 2006 Expired tidal volumes measured by hot-wire anemometer during high-frequency oscillation in preterm infants Pediatr Pulmonol 41 428 433 16547962 10.1002/ppul.20367 (Pubitemid 43673061)
    • (2006) Pediatric Pulmonology , vol.41 , Issue.5 , pp. 428-433
    • Zimova-Herknerova, M.1    Plavka, R.2