Medical electrical equipment. Particular requirements for the safety of magnetic resonance for medical diagnosis
-
Japanese Industrial Standards (JIS), JIS Z 4951
-
Japanese Industrial Standards (JIS). Medical electrical equipment. Particular requirements for the safety of magnetic resonance for medical diagnosis. Japanese Industrial Standards 2004; JIS Z 4951.
-
(2004)
Japanese Industrial Standards
-
-
-
2
-
-
35848971339
-
Medical electrical equipment. Particular requirements for the safety of magnetic resonance equipment for medical diagnosis
-
International Electro technical Commission (IEC), IEC60601-2-33
-
International Electro technical Commission (IEC). Medical electrical equipment. Particular requirements for the safety of magnetic resonance equipment for medical diagnosis. International Standard 2002; IEC60601-2-33.
-
(2002)
International Standard
-
-
-
3
-
-
84863805136
-
Study of RF heat of dental magnetic keeper with 1.5-tesla MR equipment
-
Japanese with English abstract
-
Yamada M, Okada T, Kuwayama Y, Nakane M, Anno H. Study of RF heat of dental magnetic keeper with 1.5-tesla MR equipment. Jpn J Radiol Technol 2000; 11:1371-1375' [Japanese with English abstract]
-
(2000)
Jpn J Radiol Technol
, vol.11
, pp. 1371-1375
-
-
Yamada, M.1
Okada, T.2
Kuwayama, Y.3
Nakane, M.4
Anno, H.5
-
4
-
-
0033183826
-
Heating near implanted medical devices by the MRI RF-magnetic field
-
Nyenhuis JA, Kildishev AV, Bourland JD, Foster KS, Graber G. Heating near implanted medical devices by the MRI RF-magnetic field. IEEE Trans Magnetics 1999; 35:4133-4135.
-
(1999)
IEEE Trans Magnetics
, vol.35
, pp. 4133-4135
-
-
Nyenhuis, J.A.1
Kildishev, A.V.2
Bourland, J.D.3
Foster, K.S.4
Graber, G.5
-
5
-
-
0028509215
-
Ex vivo evaluation of ferromagnetism, heating, and artifacts produced by heart valve prosthesis exposed to a 1.5-T MR system
-
Shellock FG, Morisoli SM. Ex vivo evaluation of ferromagnetism, heating, and artifacts produced by heart valve prosthesis exposed to a 1.5-T MR system. J Magn Reson Imaging 1994; 4:756-758.
-
(1994)
J Magn Reson Imaging
, vol.4
, pp. 756-758
-
-
Shellock, F.G.1
Morisoli, S.M.2
-
6
-
-
0019483220
-
Potential hazards in NMR imaging: Heating effects of changing magnetic fields and RF fields on small metallic implants
-
Davis PL, Crooks L, Arakawa M, McRee R, Kaufman L, Margulis AR. Potential hazards in NMR imaging: heating effects of changing magnetic fields and RF fields on small metallic implants. AJR Am J Roentgenol 1981; 137:857-860.
-
(1981)
AJR Am J Roentgenol
, vol.137
, pp. 857-860
-
-
Davis, P.L.1
Crooks, L.2
Arakawa, M.3
McRee, R.4
Kaufman, L.5
Margulis, A.R.6
-
7
-
-
0023124231
-
Intrauterine contraceptive devices: MR imaging
-
Mark AS, Hricak H. Intrauterine contraceptive devices: MR imaging. Radiology 1987; 162:311- 314.
-
(1987)
Radiology
, vol.162
, pp. 311-314
-
-
Mark, A.S.1
Hricak, H.2
-
8
-
-
20344383997
-
Bilateral neurostimulation systems used for deep brain stimulation: In vitro study of MRI-related heating at 1.5 T and implications for clinical imaging of the brain
-
Bhidayasiri R, Bronstein JM, Sinha S, et al. Bilateral neurostimulation systems used for deep brain stimulation: in vitro study of MRI-related heating at 1.5 T and implications for clinical imaging of the brain. Magn Reson Imaging 2005; 23: 549-555.
-
(2005)
Magn Reson Imaging
, vol.23
, pp. 549-555
-
-
Bhidayasiri, R.1
Bronstein, J.M.2
Sinha, S.3
-
9
-
-
0023706020
-
Heating effects of metallic implants by MRI examinations
-
Buchli R, Boesiger P, Meier D. Heating effects of metallic implants by MRI examinations. Magn Res Med 1988; 7:255-261.
-
(1988)
Magn Res Med
, vol.7
, pp. 255-261
-
-
Buchli, R.1
Boesiger, P.2
Meier, D.3
-
10
-
-
3242785606
-
Evaluation of specific absorption rate as a dosimeter of MRI-related implant heating
-
Baker KB, Tkach JA, Nyenhuis JA, et al. Evaluation of specific absorption rate as a dosimeter of MRI-related implant heating. J Magn Reson Imaging 2004; 20:315-320.
-
(2004)
J Magn Reson Imaging
, vol.20
, pp. 315-320
-
-
Baker, K.B.1
Tkach, J.A.2
Nyenhuis, J.A.3
-
12
-
-
0242476911
-
Severe burn of finger caused by using a pulse oximeter during MR imaging (letter)
-
Shellock FG, Slimp GL. Severe burn of finger caused by using a pulse oximeter during MR imaging (letter). AJR Am J Roentgenol 1989; 153:1105.
-
(1989)
AJR Am J Roentgenol
, vol.153
, pp. 1105
-
-
Shellock, F.G.1
Slimp, G.L.2
-
13
-
-
0029996658
-
Unusual burn of the lower extremities caused by a closed conducting loop in a patient at MR imaging
-
Knopp MV, Essig M, Debus J, Zabel HJ, van Kaick G. Unusual burn of the lower extremities caused by a closed conducting loop in a patient at MR imaging. Radiology 1996; 200:572-575.
-
(1996)
Radiology
, vol.200
, pp. 572-575
-
-
Knopp, M.V.1
Essig, M.2
Debus, J.3
Zabel, H.J.4
van Kaick, G.5
-
14
-
-
84863805636
-
Thermal injuries in two patients at MR imaging
-
Japanese with English abstract
-
Okuda T, Asano C, Yoshimatsu S, Saito R, Suga-hara T, Yamashita Y. Thermal injuries in two patients at MR imaging. Jpn J Magn Reson Med 2004; 24:88-91. [Japanese with English abstract]
-
(2004)
Jpn J Magn Reson Med
, vol.24
, pp. 88-91
-
-
Okuda, T.1
Asano, C.2
Yoshimatsu, S.3
Saito, R.4
Suga-Hara, T.5
Yamashita, Y.6
-
15
-
-
0033918247
-
Radiofrequency energy-induced heating during MR procedures: A review
-
Shellock FG. Radiofrequency energy-induced heating during MR procedures: a review. J Magn Reson Imaging 2000; 12:30-36.
-
(2000)
J Magn Reson Imaging
, vol.12
, pp. 30-36
-
-
Shellock, F.G.1
-
16
-
-
4143152698
-
MR procedures: Biologic effects, safety and patient care
-
Shellock FG, Crues JV. MR procedures: biologic effects, safety and patient care. Radiology 2004; 232:635-652.
-
(2004)
Radiology
, vol.232
, pp. 635-652
-
-
Shellock, F.G.1
Crues, J.V.2
-
18
-
-
0023814837
-
High-field-strength MR imaging and metallic biomedical implants: An ex vivo evaluation of deflection forces
-
Shellock FG, Crues JV. High-field-strength MR imaging and metallic biomedical implants: an ex vivo evaluation of deflection forces. AJR Am J Roentgenol 1988; 151:389-392.
-
(1988)
AJR Am J Roentgenol
, vol.151
, pp. 389-392
-
-
Shellock, F.G.1
Crues, J.V.2
-
19
-
-
39049184153
-
Evaluation of RF heating on humerus implant in phantoms during 1.5T MR imaging and comparisons with electromagnetic simulation
-
Muranaka H, Horiguchi T, Usui S, et al. Evaluation of RF heating on humerus implant in phantoms during 1.5T MR imaging and comparisons with electromagnetic simulation. Magn Reson Med Sci 2006; 5:79-88.
-
(2006)
Magn Reson Med Sci
, vol.5
, pp. 79-88
-
-
Muranaka, H.1
Horiguchi, T.2
Usui, S.3
-
20
-
-
0242304638
-
An MRI phantom using carrageenan gel
-
Japanese with English abstract
-
Kato H, Kuroda M, Yoshimura K, et al. An MRI phantom using carrageenan gel. Jpn J Magn Res-on Med 2000; 20:365-373. [Japanese with English abstract]
-
(2000)
Jpn J Magn Res-on Med
, vol.20
, pp. 365-373
-
-
Kato, H.1
Kuroda, M.2
Yoshimura, K.3
-
21
-
-
77956220130
-
Evaluation of RF heating on hip joint implant in phantom during MRI examinations
-
Muranaka H, Horiguchi T, Ueda Y, Usui S, Tanki N, Nakamura O. Evaluation of RF heating on hip joint implant in phantom during MRI examinations. Jpn J Radiol Technol 2010; 66:725-733.
-
(2010)
Jpn J Radiol Technol
, vol.66
, pp. 725-733
-
-
Muranaka, H.1
Horiguchi, T.2
Ueda, Y.3
Usui, S.4
Tanki, N.5
Nakamura, O.6
-
22
-
-
45849123275
-
Dependence of RF heating on SAR and implant position in a 1.5T MR system
-
Muranaka H, Horiguchi T, Usui S, Ueda Y, Nakamura O, Ikeda F. Dependence of RF heating on SAR and implant position in a 1.5T MR system. Magn Reson Med Sci 2007; 6:199-209.
-
(2007)
Magn Reson Med Sci
, vol.6
, pp. 199-209
-
-
Muranaka, H.1
Horiguchi, T.2
Usui, S.3
Ueda, Y.4
Nakamura, O.5
Ikeda, F.6
-
23
-
-
0035383751
-
Thermal injures associated with MRI
-
Dempsey MF, Condon B. Thermal injures associated with MRI. Clin Radiol 2001; 56:457-465.
-
(2001)
Clin Radiol
, vol.56
, pp. 457-465
-
-
Dempsey, M.F.1
Condon, B.2
-
24
-
-
0035085031
-
Investigation of the factors responsible for burns during MRI
-
Dempsey MF, Condon B, Hadley DM. Investigation of the factors responsible for burns during MRI. J Magn Reson Imaging 2001; 13:627-631.
-
(2001)
J Magn Reson Imaging
, vol.13
, pp. 627-631
-
-
Dempsey, M.F.1
Condon, B.2
Hadley, D.M.3
-
27
-
-
1842586446
-
Parallel excitation with an array of transmit coils
-
Zhu Y. Parallel excitation with an array of transmit coils. Magn Reson Med 2004; 51:775-784.
-
(2004)
Magn Reson Med
, vol.51
, pp. 775-784
-
-
Zhu, Y.1
-
28
-
-
26844546900
-
Experimental analysis of parallel excitation using dedicated coil setups and simultaneous RF transmission on multiple channels
-
Ullmann P, Junge S, Wick M, Seifert F, Ruhm W, Hennig J. Experimental analysis of parallel excitation using dedicated coil setups and simultaneous RF transmission on multiple channels. Magn Res-on Med 2005; 54:994-1001.
-
(2005)
Magn Res-on Med
, vol.54
, pp. 994-1001
-
-
Ullmann, P.1
Junge, S.2
Wick, M.3
Seifert, F.4
Ruhm, W.5
Hennig, J.6
-
29
-
-
60549086626
-
Electrodynamic constraints on homogeneity and radiofrequency power deposition in multiple coil excitations
-
Lattanzi R, Sodickson DK, Grant AK, Zhu Y. Electrodynamic constraints on homogeneity and radiofrequency power deposition in multiple coil excitations. Magn Reson Med 2009; 61:315-334.
-
(2009)
Magn Reson Med
, vol.61
, pp. 315-334
-
-
Lattanzi, R.1
Sodickson, D.K.2
Grant, A.K.3
Zhu, Y.4
-
30
-
-
66249138443
-
Ultra-low output impedance RF power amplifier for parallel excitation
-
Chu X, Yang X, Liu Y, Sabate J, Zhu Y. Ultra-low output impedance RF power amplifier for parallel excitation. Magn Reson Med 2009; 61:952-961.
-
(2009)
Magn Reson Med
, vol.61
, pp. 952-961
-
-
Chu, X.1
Yang, X.2
Liu, Y.3
Sabate, J.4
Zhu, Y.5
-
31
-
-
73349141558
-
An eight-channel phased array RF coil for spine MR imaging at 7T
-
Kraff O, Bitz AK, Kruszona S, et al. An eight-channel phased array RF coil for spine MR imaging at 7T. Invest Radiol 2009; 44:734-740.
-
(2009)
Invest Radiol
, vol.44
, pp. 734-740
-
-
Kraff, O.1
Bitz, A.K.2
Kruszona, S.3
|