메뉴 건너뛰기




Volumn 3, Issue 3, 2010, Pages 215-224

Particle removal efficiency of the portable HEPA air cleaner in a simulated hospital ward

Author keywords

hospital ward; particle; portable HEPA filter

Indexed keywords


EID: 79960912833     PISSN: 19963599     EISSN: 19968744     Source Type: Journal    
DOI: 10.1007/s12273-010-0005-4     Document Type: Article
Times cited : (48)

References (13)
  • 1
    • 85031226050 scopus 로고
    • Testing of HEPA and ventilation filters
    • AEA Technology
    • AEA Technology (1994). Testing of HEPA and ventilation filters. Filtration & Separation, 31, 781.
    • (1994) Filtration & Separation , vol.31 , pp. 781
  • 2
    • 0025999529 scopus 로고
    • Efficacy of an air-cleaning device equipped with a high-efficiency particulate air filter in house dust mite respiratory allergy
    • Antonicelli L, Bilo MB, Pucci S, Schou C, Bonifazi F (1991). Efficacy of an air-cleaning device equipped with a high-efficiency particulate air filter in house dust mite respiratory allergy. Allergy, 46: 594-600.
    • (1991) Allergy , vol.46 , pp. 594-600
    • Antonicelli, L.1    Bilo, M.B.2    Pucci, S.3    Schou, C.4    Bonifazi, F.5
  • 3
    • 0003895491 scopus 로고    scopus 로고
    • Aalborg: Department of Building Technology and Structural Engineering. Aalborg University
    • Brohus H (1997). Personal exposure to contaminant sources in ventilated rooms (p. 22). Department of Building Technology and Structural Engineering. Aalborg University, Aalborg.
    • (1997) Personal Exposure to Contaminant Sources in Ventilated Rooms , pp. 22
    • Brohus, H.1
  • 4
    • 8644263177 scopus 로고    scopus 로고
    • Center for Disease ControlPrevention, Atlanta, USA: U.S. Department of Health and Human Services Centers for Disease Control and Prevention (CDC)
    • Center for Disease Control and Prevention (CDC) (2003). Guidelines for Environmental Infection Control in Health-Care Facilities. U. S. Department of Health and Human Services Centers for Disease Control and Prevention (CDC), Atlanta, USA.
    • (2003) Guidelines for Environmental Infection Control in Health-Care Facilities
  • 5
    • 0345267049 scopus 로고    scopus 로고
    • Efficiency of a portable indoor air cleaner in removing pollens and fungal spores
    • Cheng YS, Lu JC, Chen TR (1998). Efficiency of a portable indoor air cleaner in removing pollens and fungal spores. Aerosol Science and Technology, 29: 92-101.
    • (1998) Aerosol Science and Technology , vol.29 , pp. 92-101
    • Cheng, Y.S.1    Lu, J.C.2    Chen, T.R.3
  • 7
    • 0035393771 scopus 로고    scopus 로고
    • Measurement and simulation of the IAQ impact of particle air cleaners in a single-zone building
    • Emmerich SJ, Nabinger SJ (2001). Measurement and simulation of the IAQ impact of particle air cleaners in a single-zone building. HVAC&R Research, 7: 223-244.
    • (2001) HVAC&R Research , vol.7 , pp. 223-244
    • Emmerich, S.J.1    Nabinger, S.J.2
  • 9
    • 0032213329 scopus 로고    scopus 로고
    • Measurement of the performance of air cleaners against the particulate element of rosin-based solder flux fume
    • Johnson AE, Brown RC (1998). Measurement of the performance of air cleaners against the particulate element of rosin-based solder flux fume. Annals of Occupational Hygiene, 42: 511-519.
    • (1998) Annals of Occupational Hygiene , vol.42 , pp. 511-519
    • Johnson, A.E.1    Brown, R.C.2
  • 10
    • 33644681944 scopus 로고    scopus 로고
    • Achieving 'excellent' indoor air quality in commercial offices equipped with air-handling unit-respirable suspended particulate
    • Lam KS, Chan FS, Fung WY, Lui BSS, Lau LWL (2006). Achieving 'excellent' indoor air quality in commercial offices equipped with air-handling unit-respirable suspended particulate. Indoor Air, 16: 86-97.
    • (2006) Indoor Air , vol.16 , pp. 86-97
    • Lam, K.S.1    Chan, F.S.2    Fung, W.Y.3    Lui, B.S.S.4    Lau, L.W.L.5
  • 11
    • 67651171231 scopus 로고    scopus 로고
    • Impact of placement of portable air cleaning devices in multizone residential environments
    • Novoselac A, Siegel JA (2009). Impact of placement of portable air cleaning devices in multizone residential environments. Building and Environment, 44: 2348-2356.
    • (2009) Building and Environment , vol.44 , pp. 2348-2356
    • Novoselac, A.1    Siegel, J.A.2
  • 12
    • 15744394913 scopus 로고    scopus 로고
    • The effectiveness of stand alone air cleaners for shelter-in-place
    • Ward M, Siegel JA, Corsi RL (2005). The effectiveness of stand alone air cleaners for shelter-in-place. Indoor Air, 15: 127-134.
    • (2005) Indoor Air , vol.15 , pp. 127-134
    • Ward, M.1    Siegel, J.A.2    Corsi, R.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.