Volumn 31, Issue 14-15, 2011, Pages 2778-2786

Experimental study on frosting control of mobile air conditioning system with microchannel evaporator

Author keywords

Experiment; Frosting; Microchannel evaporator; Mobile air conditioning (MAC) system

Indexed keywords

AUTOMOTIVE AIR-CONDITIONING SYSTEMS; BENCH TESTS; EXPERIMENTAL STUDIES; FROSTING; INSTALLATION POSITION; LAMINATED EVAPORATOR; MOBILE AIR CONDITIONING; TEMPERATURE RANGE; TEMPERATURE SWINGS; TEST RESULTS; VEHICLE TESTS;

EID: 79960905275     PISSN: 13594311     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.applthermaleng.2011.04.051     Document Type: Article
Times cited : (13)

References (16)
  • 2
    • 0345003775 scopus 로고    scopus 로고
    • Evaporation heat transfer and pressure drop of refrigerant R134a in a small pipe
    • Y.Y. Yan, and T.F. Lin Evaporation heat transfer and pressure drop of refrigerant R134a in a small pipe Int. J. Heat Mass Transfer. 41 1998 4183 4194
    • (1998) Int. J. Heat Mass Transfer. , vol.41 , pp. 4183-4194
    • Yan, Y.Y.1    Lin, T.F.2
  • 3
    • 1842431272 scopus 로고    scopus 로고
    • Heat transfer model for evaporation in microchannels. Part I: Presentation of the model
    • DOI 10.1016/j.ijheatmasstransfer.2004.01.006, PII S0017931004000316
    • J.R. Thome, V. Dupont, and A.M. Jacobi Heat transfer model for evaporation in micro-channels, part I: presentation of the model Int. J. Heat Mass Transfer. 47 2004 3375 3385 (Pubitemid 38616311)
    • (2004) International Journal of Heat and Mass Transfer , vol.47 , Issue.14-16 , pp. 3375-3385
    • Thome, J.R.1    Dupont, V.2    Jacobi, A.M.3
  • 4
    • 2442526598 scopus 로고    scopus 로고
    • Heat transfer model for evaporation in microchannels. Part II: Comparison with the database
    • DOI 10.1016/j.ijheatmasstransfer.2004.01.007, PII S0017931004000328
    • V. Dupont, R. Thome, and A.M. Jacobi Heat transfer model for evaporation in micro-channels, part II: comparison with the database Int. J. Heat Mass Transfer. 47 2004 3387 3401 (Pubitemid 38616312)
    • (2004) International Journal of Heat and Mass Transfer , vol.47 , Issue.14-16 , pp. 3387-3401
    • Dupont, V.1    Thome, J.R.2    Jacobi, A.M.3
  • 5
    • 69449100955 scopus 로고    scopus 로고
    • Investigating performance of new mini-channel evaporators
    • Z.G. Qi, J.P. Chen, and R. Radermacher Investigating performance of new mini-channel evaporators Appl. Therm. Eng. 29 2009 3561 3567
    • (2009) Appl. Therm. Eng. , vol.29 , pp. 3561-3567
    • Qi, Z.G.1    Chen, J.P.2    Radermacher, R.3
  • 6
    • 74149083378 scopus 로고    scopus 로고
    • Performance enhancement study of mobile air conditioning system using microchannel heat exchangers
    • 10.1016/j.ijrefrig.2009.08.014
    • Z.G. Qi, Y. Zhao, and J. Chen Performance enhancement study of mobile air conditioning system using microchannel heat exchangers Int. J. Refrig. 2009 10.1016/j.ijrefrig.2009.08.014
    • (2009) Int. J. Refrig.
    • Qi, Z.G.1    Zhao, Y.2    Chen, J.3
  • 8
    • 0035393431 scopus 로고    scopus 로고
    • Research on corrugated multi-louvered fins under dehumidification
    • DOI 10.1002/htj.1025
    • H. Osada, and H. Aoki Research on corrugated multi-louvered fins under dehumidification Heat Transfer Asian Res. 30 5 2001 383 393 (Pubitemid 32693184)
    • (2001) Heat Transfer - Asian Research , vol.30 , Issue.5 , pp. 383-393
    • Osada, H.1    Aoki, H.2    Ohara, T.3    Kuroyanagi, I.4
  • 9
    • 33745282663 scopus 로고    scopus 로고
    • Experimental study on the effect of frost parameters on domestic refrigerator finned tube evaporator coils
    • DOI 10.1016/j.applthermaleng.2006.04.015, PII S1359431106001335
    • D.B. Özkan, and E. Özil Experimental study on the effect of frost parameters on domestic refrigerator finned tube evaporator coils Appl. Therm. Eng. 26 17-18 2006 2490 2493 (Pubitemid 43928775)
    • (2006) Applied Thermal Engineering , vol.26 , Issue.17-18 , pp. 2490-2493
    • Ozkan, D.B.1    Ozil, E.2
  • 10
    • 73149117796 scopus 로고    scopus 로고
    • Comparison of heat pump performance using fin-and-tube and microchannel heat exchangers under frost conditions
    • 10.1016/j.apenergy.2009.08.021
    • L.L. Shao, L. Yang, and C.L. Zhang Comparison of heat pump performance using fin-and-tube and microchannel heat exchangers under frost conditions Appl. Energy. 2009 10.1016/j.apenergy.2009.08.021
    • (2009) Appl. Energy.
    • Shao, L.L.1    Yang, L.2    Zhang, C.L.3
  • 11
    • 19944405789 scopus 로고    scopus 로고
    • Numerical analysis of evaporator frosting in automotive air-conditioning system with a variable-displacement compressor
    • C.Q. Tian, X.T. Li, and X.J. Yang Numerical analysis of evaporator frosting in automotive air-conditioning system with a variable-displacement compressor Appl. Energy. 82 1 2005 1 22
    • (2005) Appl. Energy. , vol.82 , Issue.1 , pp. 1-22
    • Tian, C.Q.1    Li, X.T.2    Yang, X.J.3
  • 12
    • 36849071932 scopus 로고    scopus 로고
    • Refrigerant flow instability as a means to predict the need for defrosting the evaporator in a retail display freezer cabinet
    • DOI 10.1016/j.ijrefrig.2007.05.015, PII S0140700707001569
    • J.M.W. Lawrence, and J.A. Evans Refrigerant flow instability as a means to predict the need for defrosting the evaporator in a retail display freezer cabinet Int. J. Refrig. 31 1 2008 107 112 (Pubitemid 350225716)
    • (2008) International Journal of Refrigeration , vol.31 , Issue.1 , pp. 107-112
    • Lawrence, J.M.W.1    Evans, J.A.2
  • 14
    • 20344386501 scopus 로고    scopus 로고
    • Frost Density Measurement for Evaporator Defrosting Control
    • November 13-19 2004, Anaheim, California, USA. Heat Transfer Paper no. IMECE2004-62218
    • J. Iragorry, Y-X. Tao, Frost Density Measurement for Evaporator Defrosting Control. In: ASME 2004 International Mechanical Engineering Congress and Exposition, November 13-19 2004, Anaheim, California, USA. Heat Transfer, vol 1. Paper no. IMECE2004-62218 pp. 435-441.
    • ASME 2004 International Mechanical Engineering Congress and Exposition , vol.1 , pp. 435-441
    • Iragorry, J.1    Tao, Y.-X.2
  • 15
    • 17744367616 scopus 로고    scopus 로고
    • Frost temperature relations for defrosting sensing system
    • DOI 10.1115/1.1860566
    • J. Iragorry, and Y.X. Tao Frost temperature relations for defrosting sensing system J. Heat. Transfer. 127 2005 344 351 (Pubitemid 40579046)
    • (2005) Journal of Heat Transfer , vol.127 , Issue.3 , pp. 344-351
    • Iragorry, J.1    Tao, Y.-X.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.