메뉴 건너뛰기




Volumn 122, Issue 9, 2011, Pages 1878-1882

MRI-validation of SEP monitoring for ischemic events during microsurgical clipping of intracranial aneurysms

Author keywords

Cerebrovascular surgery; Intraoperative neuromonitoring; Ischemia; MRI; SEP

Indexed keywords

ADULT; AGED; ANEURYSM CLIP; ARTERY CLAMP; ARTERY OCCLUSION; ARTICLE; BRAIN ISCHEMIA; CLINICAL EVALUATION; CONTROLLED STUDY; DIFFUSION WEIGHTED IMAGING; EVOKED SOMATOSENSORY RESPONSE; FEMALE; HEMIPARESIS; HUMAN; INTRACRANIAL ANEURYSM; MAJOR CLINICAL STUDY; MALE; MAXIMUM ALLOWABLE CONCENTRATION; NEUROMONITORING; NUCLEAR MAGNETIC RESONANCE IMAGING; POSTOPERATIVE COMPLICATION; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; VALIDATION STUDY;

EID: 79960894262     PISSN: 13882457     EISSN: 18728952     Source Type: Journal    
DOI: 10.1016/j.clinph.2011.02.007     Document Type: Article
Times cited : (18)

References (21)
  • 2
    • 0023472137 scopus 로고
    • Somatosensory evoked potentials after sequential extremity stimulation: a new method for improved monitoring accuracy
    • Friedman W.A., Curran M.T. Somatosensory evoked potentials after sequential extremity stimulation: a new method for improved monitoring accuracy. Neurosurgery 1987, 21:755-758.
    • (1987) Neurosurgery , vol.21 , pp. 755-758
    • Friedman, W.A.1    Curran, M.T.2
  • 3
    • 0023272511 scopus 로고
    • Evoked potential monitoring during aneurysm operation: observations after fifty cases
    • Friedman W.A., Kaplan B.L., Day A.L., Sypert G.W., Curran M.T. Evoked potential monitoring during aneurysm operation: observations after fifty cases. Neurosurgery 1987, 20:678-687.
    • (1987) Neurosurgery , vol.20 , pp. 678-687
    • Friedman, W.A.1    Kaplan, B.L.2    Day, A.L.3    Sypert, G.W.4    Curran, M.T.5
  • 4
    • 0026058776 scopus 로고
    • Variability of somatosensory cortical evoked potentials during spinal surgery. Effects of anesthetic technique and high-pass digital filtering
    • Kalkman C.J., ten Brink S.A., Been H.D., Bovill J.G. Variability of somatosensory cortical evoked potentials during spinal surgery. Effects of anesthetic technique and high-pass digital filtering. Spine 1991, 16:924-929.
    • (1991) Spine , vol.16 , pp. 924-929
    • Kalkman, C.J.1    ten Brink, S.A.2    Been, H.D.3    Bovill, J.G.4
  • 5
    • 60549097231 scopus 로고    scopus 로고
    • Symptomatic and silent ischemia associated with microsurgical clipping of intracranial aneurysms: evaluation with diffusion-weighted MRI
    • Krayenbühl N., Erdem E., Oinas M., Krisht A.F. Symptomatic and silent ischemia associated with microsurgical clipping of intracranial aneurysms: evaluation with diffusion-weighted MRI. Stroke 2009, 40:129-133.
    • (2009) Stroke , vol.40 , pp. 129-133
    • Krayenbühl, N.1    Erdem, E.2    Oinas, M.3    Krisht, A.F.4
  • 6
    • 16844381099 scopus 로고    scopus 로고
    • Surgical clipping of complex basilar apex aneurysms: a strategy for successful outcome using the pretemporal transzygomatic transcavernous approach
    • Krisht A.F., Kadri P.A. Surgical clipping of complex basilar apex aneurysms: a strategy for successful outcome using the pretemporal transzygomatic transcavernous approach. Neurosurgery 2005, 56:261-273.
    • (2005) Neurosurgery , vol.56 , pp. 261-273
    • Krisht, A.F.1    Kadri, P.A.2
  • 7
    • 0023133572 scopus 로고
    • Electrophysiological monitoring during basilar aneurysm operation
    • Little J.R., Lesser R.P., Luders H. Electrophysiological monitoring during basilar aneurysm operation. Neurosurgery 1987, 20:421-427.
    • (1987) Neurosurgery , vol.20 , pp. 421-427
    • Little, J.R.1    Lesser, R.P.2    Luders, H.3
  • 8
    • 0036869584 scopus 로고    scopus 로고
    • Sensitivity of scalp EEG, cortical EEG, and somatosensory evoked responses during surgery for intracranial aneurysms
    • Martin C.J., Sinson G., Patterson T., Zager E.L., Stecker M.M., Solomon R.A., Steinberg G.K. Sensitivity of scalp EEG, cortical EEG, and somatosensory evoked responses during surgery for intracranial aneurysms. Surg Neurol 2002, 58:317-321.
    • (2002) Surg Neurol , vol.58 , pp. 317-321
    • Martin, C.J.1    Sinson, G.2    Patterson, T.3    Zager, E.L.4    Stecker, M.M.5    Solomon, R.A.6    Steinberg, G.K.7
  • 9
    • 0027184174 scopus 로고
    • Permissible temporary occlusion time in aneurysm surgery as evaluated by evoked potential monitoring
    • Mizoi K., Yoshimoto T. Permissible temporary occlusion time in aneurysm surgery as evaluated by evoked potential monitoring. Neurosurgery 1993, 33:434-440.
    • (1993) Neurosurgery , vol.33 , pp. 434-440
    • Mizoi, K.1    Yoshimoto, T.2
  • 11
    • 1442282523 scopus 로고    scopus 로고
    • Monitoring of motor evoked potentials compared with somatosensory evoked potentials and microvascular Doppler ultrasonography in cerebral aneurysm surgery
    • Neuloh G., Schramm J. Monitoring of motor evoked potentials compared with somatosensory evoked potentials and microvascular Doppler ultrasonography in cerebral aneurysm surgery. J Neurosurg 2004, 100:389-399.
    • (2004) J Neurosurg , vol.100 , pp. 389-399
    • Neuloh, G.1    Schramm, J.2
  • 12
    • 0028200826 scopus 로고
    • Effects of stimulus intensity and duration on posterior tibial nerve somatosensory-evoked potential patterns obtained under anesthesia
    • Rappaport M., Ruiz Portillo S., Ortiz D., Fountain S.S., Kula T.A. Effects of stimulus intensity and duration on posterior tibial nerve somatosensory-evoked potential patterns obtained under anesthesia. Spine 1994, 19:1525-1529.
    • (1994) Spine , vol.19 , pp. 1525-1529
    • Rappaport, M.1    Ruiz Portillo, S.2    Ortiz, D.3    Fountain, S.S.4    Kula, T.A.5
  • 13
    • 0035007313 scopus 로고    scopus 로고
    • Remifentanil- and fentanyl-based anesthesia for intraoperative monitoring of somatosensory evoked potentials
    • Samra S.K., Dy E.A., Welch K.B., Lovely L.K., Graziano G.P. Remifentanil- and fentanyl-based anesthesia for intraoperative monitoring of somatosensory evoked potentials. Anesth Analg 2001, 92:1510-1515.
    • (2001) Anesth Analg , vol.92 , pp. 1510-1515
    • Samra, S.K.1    Dy, E.A.2    Welch, K.B.3    Lovely, L.K.4    Graziano, G.P.5
  • 14
    • 0025313495 scopus 로고
    • Surgical and electrophysiological observations during clipping of 134 aneurysms with evoked potential monitoring
    • Schramm J., Koht A., Schmidt G., Pechstein U., Taniguchi M., Fahlbusch R. Surgical and electrophysiological observations during clipping of 134 aneurysms with evoked potential monitoring. Neurosurgery 1990, 26:61-70.
    • (1990) Neurosurgery , vol.26 , pp. 61-70
    • Schramm, J.1    Koht, A.2    Schmidt, G.3    Pechstein, U.4    Taniguchi, M.5    Fahlbusch, R.6
  • 15
    • 27744537004 scopus 로고    scopus 로고
    • Intraoperative monitoring using somatosensory evoked potentials. A position statement by the American Society of Neurophysiological Monitoring
    • Toleikis J.R. Intraoperative monitoring using somatosensory evoked potentials. A position statement by the American Society of Neurophysiological Monitoring. J Clin Monit Comput 2005, 19:241-258.
    • (2005) J Clin Monit Comput , vol.19 , pp. 241-258
    • Toleikis, J.R.1
  • 18
    • 0036121787 scopus 로고    scopus 로고
    • The impact of neurophysiological intraoperative monitoring on surgical decisions: a critical analysis of 423 cases
    • Wiedemayer H., Fauser B., Sandalcioglu I.E., Schafer H., Stolke D. The impact of neurophysiological intraoperative monitoring on surgical decisions: a critical analysis of 423 cases. J Neurosurg 2002, 96:255-262.
    • (2002) J Neurosurg , vol.96 , pp. 255-262
    • Wiedemayer, H.1    Fauser, B.2    Sandalcioglu, I.E.3    Schafer, H.4    Stolke, D.5
  • 19
    • 0842309202 scopus 로고    scopus 로고
    • False negative findings in intraoperative SEP monitoring: analysis of 658 consecutive neurosurgical cases and review of published reports
    • Wiedemayer H., Sandalcioglu I.E., Armbruster W., Regel J., Schaefer H., Stolke D. False negative findings in intraoperative SEP monitoring: analysis of 658 consecutive neurosurgical cases and review of published reports. J Neurol Neurosurg Psychiatry 2004, 75:280-286.
    • (2004) J Neurol Neurosurg Psychiatry , vol.75 , pp. 280-286
    • Wiedemayer, H.1    Sandalcioglu, I.E.2    Armbruster, W.3    Regel, J.4    Schaefer, H.5    Stolke, D.6
  • 21
    • 75749132885 scopus 로고    scopus 로고
    • The selective amygdalohippocampectomy for intractable temporal limbic seizures
    • Yaşargil M.G., Krayenbühl N., Roth P., Hsu S.P., Yaşargil D.C. The selective amygdalohippocampectomy for intractable temporal limbic seizures. J Neurosurg 2010, 112:168-185.
    • (2010) J Neurosurg , vol.112 , pp. 168-185
    • Yaşargil, M.G.1    Krayenbühl, N.2    Roth, P.3    Hsu, S.P.4    Yaşargil, D.C.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.