메뉴 건너뛰기




Volumn 22, Issue 8, 2011, Pages

Two sources of error in determination of the particle concentration reduction factor of the volatile particle remover used in legislated vehicle emission measurement

Author keywords

[No Author keywords available]

Indexed keywords

SODIUM; SODIUM CHLORIDE; SOOT;

EID: 79960808940     PISSN: 09570233     EISSN: 13616501     Source Type: Journal    
DOI: 10.1088/0957-0233/22/8/085108     Document Type: Article
Times cited : (3)

References (17)
  • 1
    • 77949560653 scopus 로고    scopus 로고
    • Calibration and accuracy of a particle number measurement system
    • Giechaskiel B, Cresnoverh M, Jörgl H and Bergmann A 2010 Calibration and accuracy of a particle number measurement system Meas. Sci. Technol. 21 045102
    • (2010) Meas. Sci. Technol. , vol.21 , pp. 045102
    • Giechaskiel B, C.1
  • 2
    • 0036304912 scopus 로고    scopus 로고
    • Design and performance characteristics of three continuous-flow condensation particle counters: A summary
    • DOI 10.1016/S0169-8095(02)00014-5, PII S0169809502000145
    • Sem G J 2002 Design and performance characteristics of three continuous-flow condensation particle counters: a summary Atmos. Res. 62 267-94 (Pubitemid 34735856)
    • (2002) Atmospheric Research , vol.62 , Issue.3-4 , pp. 267-294
    • Sem, G.J.1
  • 3
    • 0029659741 scopus 로고    scopus 로고
    • Ultrafine aerosol measurement using a condensation nucleus counter with pulse height analysis
    • Saros M T, Weber R J, Marti J J and McMurry P H 1996 Ultrafine aerosol measurement using a condensation nucleus counter with pulse height analysis Aerosol Sci. Technol. 25 200-13
    • (1996) Aerosol Sci. Technol. , vol.25 , pp. 200-213
    • Saros, M.T.1    Weber, R.J.2    Marti, J.J.3    McMurry, P.H.4
  • 4
    • 0025514385 scopus 로고
    • Dependence of the performance of TSI 3020 condensation nucleus counter on pressure, flow rate, and temperature
    • Zhang Z Q and Liu B Y H 1990 Dependence of the performance of TSI 3020 condensation nucleus counter on pressure, flow-rate, and temperature Aerosol Sci. Technol. 13 493-504 (Pubitemid 20359255)
    • (1990) Aerosol Science and Technology , vol.13 , Issue.4 , pp. 493-504
    • Zhang, Z.Q.1    Liu, B.Y.H.2
  • 5
    • 0026261867 scopus 로고
    • Performance of TSI 3760 condensation nuclei counter at reduced pressures and flow rates
    • Zhang Z and Liu B Y H 1991 Performance of TSI 3760 condensation nuclei counter at reduced pressures and flow rates Aerosol Sci. Technol. 15 228-38
    • (1991) Aerosol Sci. Technol. , vol.15 , pp. 228-238
    • Zhang, Z.1    Liu, B.Y.H.2
  • 6
    • 0034962711 scopus 로고    scopus 로고
    • Counting efficiency of condensation particle counters at low-pressures with illustrative data from the upper troposphere
    • DOI 10.1016/S0021-8502(01)00037-4, PII S0021850201000374
    • Hermann M and Wiedensohler A 2001 Counting efficiency of condensation particle counters at low-pressures with illustrative data from the upper troposphere J. Aerosol Sci. 32 975-91 (Pubitemid 32618669)
    • (2001) Journal of Aerosol Science , vol.32 , Issue.8 , pp. 975-991
    • Hermann, M.1    Wiedensohler, A.2
  • 7
    • 79953679611 scopus 로고    scopus 로고
    • Laboratory evaluation of a TSI condensation particle counter (Model 3771) under airborne measurement conditions
    • Takegawa N and Sakurai H 2011 Laboratory evaluation of a TSI condensation particle counter (Model 3771) under airborne measurement conditions Aerosol Sci. Technol. 45 272-83
    • (2011) Aerosol Sci. Technol. , vol.45 , pp. 272-283
    • Takegawa, N.1    Sakurai, H.2
  • 8
    • 77049112715 scopus 로고    scopus 로고
    • Evaluation of a condensation particle counter for vehicle emission measurement: Experimental procedure and effects of calibration aerosol material
    • Wang X, Caldow R, Sem G J, Hama N and Sakurai H 2010 Evaluation of a condensation particle counter for vehicle emission measurement: experimental procedure and effects of calibration aerosol material J. Aerosol Sci. 41 306-18
    • (2010) J. Aerosol Sci. , vol.41 , pp. 306-318
    • Wang, X.1    Caldow, R.2    Sem, G.J.3    Hama, N.4    Sakurai, H.5
  • 12
    • 0025683985 scopus 로고
    • Particle activation and droplet growth processes in condensation nucleus counter: I. Theoretical background
    • Ahn K-H and Liu B Y H 1990 Particle activation and droplet growth processes in condensation nucleus counter: I. Theoretical background J. Aerosol Sci. 21 249-61
    • (1990) J. Aerosol Sci. , vol.21 , pp. 249-261
    • Ahn, K.-H.1    Liu, B.Y.H.2
  • 13
    • 0025640459 scopus 로고
    • Particle activation and droplet growth processes in condensation nucleus counter: II. Experimental study
    • Ahn K-H and Liu B Y H 1990 Particle activation and droplet growth processes in condensation nucleus counter: II. Experimental study J. Aerosol Sci. 21 263-75
    • (1990) J. Aerosol Sci. , vol.21 , pp. 263-275
    • Ahn, K.-H.1    Liu, B.Y.H.2
  • 16
    • 0032787146 scopus 로고    scopus 로고
    • A new volatility tandem differential mobility analyzer to measure the volatile sulfuric acid aerosol fraction
    • Orsini D A, Wiedensohler A, Stratmann F and Covert D S 1999 A new volatility tandem differential mobility analyzer to measure the volatile sulfuric acid aerosol fraction J. Atmos. Ocean. Technol. 16 760-72
    • (1999) J. Atmos. Ocean. Technol. , vol.16 , pp. 760-772
    • Orsini, D.A.1    Wiedensohler, A.2    Stratmann, F.3    Covert, D.S.4
  • 17
    • 0020603826 scopus 로고
    • Generation of monodisperse Ag- and NaCl-aerosols with particle diameters between 2 and 300 nm
    • Scheibel H G and Porstendörfer J 1983 Generation of monodisperse Ag- and NaCl-aerosols with particle diameters between 2 and 300 nm J. Aerosol Sci. 14 113-26
    • (1983) J. Aerosol Sci. , vol.14 , pp. 113-126
    • Scheibel H G, P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.