Volumn 75, Issue 8, 2011, Pages 1878-1884

Impact of hinge motion on in-stent restenosis after sirolimus-eluting stent implantation

Author keywords

Hinge motion; In stent restenosis; Sirolimus eluting stent

Indexed keywords

RAPAMYCIN;

EID: 79960770936     PISSN: 13469843     EISSN: 13474820     Source Type: Journal    
DOI: 10.1253/circj.CJ-10-1182     Document Type: Article
Times cited : (29)

References (27)
  • 1
    • 0343729980 scopus 로고    scopus 로고
    • Longitudinal straightening effect of stents is an additional predictor for major adverse cardiac events
    • Gyöngyösi M, Yang P, Khorsand A, Glogar D, on behalf of the Austrian Wiktor Stent Study Group and European Paragon Stent Investigators
    • Gyöngyösi M, Yang P, Khorsand A, Glogar D, on behalf of the Austrian Wiktor Stent Study Group and European Paragon Stent Investigators. Longitudinal straightening effect of stents is an additional predictor for major adverse cardiac events. J Am Coll Cardiol 2000; 35: 1580-1589.
    • (2000) J Am Coll Cardiol , vol.35 , pp. 1580-1589
  • 2
    • 0037030658 scopus 로고    scopus 로고
    • For the RAVEL Study Group. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization
    • Morice MC, Serruys PW, Sousa JE, Fajadet J, Ban Hayashi E, Perin M, et al.; for the RAVEL Study Group. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med 2002; 346: 1773-1780.
    • (2002) N Engl J Med , vol.346 , pp. 1773-1780
    • Morice, M.C.1    Serruys, P.W.2    Sousa, J.E.3    Fajadet, J.4    Ban Hayashi, E.5    Perin, M.6
  • 3
    • 0141765805 scopus 로고    scopus 로고
    • For the SIRIUS Investigators. Sirolimuseluting stents versus standard stents in patients with stenosis in a native coronary artery
    • Moses JW, Leon MB, Popma JJ, Fitzgerald PJ, Holmes DR, O'Shaughnessy C, et al; for the SIRIUS Investigators. Sirolimuseluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med 2003; 349: 1315-1323.
    • (2003) N Engl J Med , vol.349 , pp. 1315-1323
    • Moses, J.W.1    Leon, M.B.2    Popma, J.J.3    Fitzgerald, P.J.4    Holmes, D.R.5    O'Shaughnessy, C.6
  • 4
    • 0038034503 scopus 로고    scopus 로고
    • Preliminary observations regarding angiographic pattern of restenosis after rapamycin-eluting stent implantation
    • Colombo A, Orlic D, Stankovic G, Corvaja N, Spanos V, Montorfano M, et al. Preliminary observations regarding angiographic pattern of restenosis after rapamycin-eluting stent implantation. Circulation 2003; 107: 2178-2180.
    • (2003) Circulation , vol.107 , pp. 2178-2180
    • Colombo, A.1    Orlic, D.2    Stankovic, G.3    Corvaja, N.4    Spanos, V.5    Montorfano, M.6
  • 5
    • 0041807644 scopus 로고    scopus 로고
    • Coronary restenosis after sirolimus-eluting stent implantation: Morphological description and mechanical analysis from a consecutive series of cases
    • Lemos PA, Saia F, Ligthart JM, Arampatzis CA, Sianos G, Tanabe K, et al. Coronary restenosis after sirolimus-eluting stent implantation: Morphological description and mechanical analysis from a consecutive series of cases. Circulation 2003; 108: 257-260.
    • (2003) Circulation , vol.108 , pp. 257-260
    • Lemos, P.A.1    Saia, F.2    Ligthart, J.M.3    Arampatzis, C.A.4    Sianos, G.5    Tanabe, K.6
  • 6
    • 20844451557 scopus 로고    scopus 로고
    • Nonuniform strut distribution correlates with more neointimal hyperplasia after sirolimus-eluting stent implantation
    • Takebayashi H, Mintz GS, Carlier SG, Kobayashi Y, Fujii K, Yasuda T, et al. Nonuniform strut distribution correlates with more neointimal hyperplasia after sirolimus-eluting stent implantation. Circulation 2004; 110: 3430-3434.
    • (2004) Circulation , vol.110 , pp. 3430-3434
    • Takebayashi, H.1    Mintz, G.S.2    Carlier, S.G.3    Kobayashi, Y.4    Fujii, K.5    Yasuda, T.6
  • 7
    • 33847339687 scopus 로고    scopus 로고
    • Incidence and clinical impact of coronary stent fracture after sirolimus-eluting stent implantation
    • Aoki J, Nakazawa G, Tanabe K, Hoye A, Yamamoto H, Nakayama T, et al. Incidence and clinical impact of coronary stent fracture after sirolimus-eluting stent implantation. Catheter Cardiovasc Interv 2007; 69: 380-386.
    • (2007) Catheter Cardiovasc Interv , vol.69 , pp. 380-386
    • Aoki, J.1    Nakazawa, G.2    Tanabe, K.3    Hoye, A.4    Yamamoto, H.5    Nakayama, T.6
  • 8
    • 73249121409 scopus 로고    scopus 로고
    • Predictors and prognosis of stent fracture after sirolimus-eluting stent implantation
    • Ino Y, Toyoda Y, Tanaka A, Ishii S, Kusuyama Y, Kubo T, et al. Predictors and prognosis of stent fracture after sirolimus-eluting stent implantation. Circ J 2009; 73: 2036-2041.
    • (2009) Circ J , vol.73 , pp. 2036-2041
    • Ino, Y.1    Toyoda, Y.2    Tanaka, A.3    Ishii, S.4    Kusuyama, Y.5    Kubo, T.6
  • 9
    • 63149156312 scopus 로고    scopus 로고
    • Frequency, predictors and outcome of stent fracture after sirolimuseluting stent implantation
    • Umeda H, Gochi T, Iwase M, Izawa H, Shimizu T, Ishiki R, et al. Frequency, predictors and outcome of stent fracture after sirolimuseluting stent implantation. Int J Cardiol 2009; 133: 321-326.
    • (2009) Int J Cardiol , vol.133 , pp. 321-326
    • Umeda, H.1    Gochi, T.2    Iwase, M.3    Izawa, H.4    Shimizu, T.5    Ishiki, R.6
  • 10
    • 62849102316 scopus 로고    scopus 로고
    • A qualitative and quantitative angiographic analysis of stent fracture late following sirolimus-eluting stent implantation
    • Popma JJ, Tiroch K, Almonacid A, Cohen S, Kandzari DE, Leon MB, et al. A qualitative and quantitative angiographic analysis of stent fracture late following sirolimus-eluting stent implantation. Am J Cardiol 2009; 103: 923-929.
    • (2009) Am J Cardiol , vol.103 , pp. 923-929
    • Popma, J.J.1    Tiroch, K.2    Almonacid, A.3    Cohen, S.4    Kandzari, D.E.5    Leon, M.B.6
  • 11
    • 77957849281 scopus 로고    scopus 로고
    • Serial angiographic findings and prognosis of stent fracture site without early restenosis after sirolimus-eluting stent implantation
    • Ino Y, Toyoda Y, Tanaka A, Ishii S, Kusuyama Y, Kubo T, et al. Serial angiographic findings and prognosis of stent fracture site without early restenosis after sirolimus-eluting stent implantation. Am Heart J 2010; 160: 775e1-e9.
    • (2010) Am Heart J , vol.160
    • Ino, Y.1    Toyoda, Y.2    Tanaka, A.3    Ishii, S.4    Kusuyama, Y.5    Kubo, T.6
  • 12
    • 61349095368 scopus 로고    scopus 로고
    • Classification and potential mechanisms of intravascular ultrasound patterns of stent fracture
    • Doi H, Maehara A, Mintz GS, Tsujita K, Kubo T, Castellanos C, et al. Classification and potential mechanisms of intravascular ultrasound patterns of stent fracture. Am J Cardiol 2009; 103: 818-823.
    • (2009) Am J Cardiol , vol.103 , pp. 818-823
    • Doi, H.1    Maehara, A.2    Mintz, G.S.3    Tsujita, K.4    Kubo, T.5    Castellanos, C.6
  • 13
    • 0033517846 scopus 로고    scopus 로고
    • Angiographic patterns of in-stent restenosis: Classification and implications for long-term outcome
    • Mehran R, Dangas G, Abizaid AS, Mintz GS, Lansky AJ, Satler LF, et al. Angiographic patterns of in-stent restenosis: Classification and implications for long-term outcome. Circulation 1999; 100: 1872-1878.
    • (1999) Circulation , vol.100 , pp. 1872-1878
    • Mehran, R.1    Dangas, G.2    Abizaid, A.S.3    Mintz, G.S.4    Lansky, A.J.5    Satler, L.F.6
  • 14
    • 77957875590 scopus 로고    scopus 로고
    • Incidence of diffuse and focal chronic stent recoil after implantation of current generation bare-metal and drug-eluting stents
    • Koo BK, Waseda K, Ako J, Hasegawa T, Shimohama T, Nakatani D, et al. Incidence of diffuse and focal chronic stent recoil after implantation of current generation bare-metal and drug-eluting stents. Int J Cardiol 2010; 144: 132-134.
    • (2010) Int J Cardiol , vol.144 , pp. 132-134
    • Koo, B.K.1    Waseda, K.2    Ako, J.3    Hasegawa, T.4    Shimohama, T.5    Nakatani, D.6
  • 15
    • 20144374297 scopus 로고    scopus 로고
    • Maintenance of long-term clinical benefit with sirolimus-eluting coronary stents: Three-year results of the RAVEL trial
    • Fajadet J, Morice MC, Bode C, Barragan P, Serruys PW, Wijns W, et al. Maintenance of long-term clinical benefit with sirolimus-eluting coronary stents: Three-year results of the RAVEL trial. Circulation 2005; 111: 1040-1044.
    • (2005) Circulation , vol.111 , pp. 1040-1044
    • Fajadet, J.1    Morice, M.C.2    Bode, C.3    Barragan, P.4    Serruys, P.W.5    Wijns, W.6
  • 16
    • 12144289311 scopus 로고    scopus 로고
    • Clinical, angiographic, and procedural predictors of angiographic restenosis after sirolimus-eluting stent implantation in complex patients: An evaluation from the Rapamycin-Eluting Stent Evaluated at Rotterdam Cardiology Hospital (RESEARCH) study
    • Lemos PA, Hoye A, Goedhart D, Arampatzis CA, Saia F, van der Giessen WJ, et al. Clinical, angiographic, and procedural predictors of angiographic restenosis after sirolimus-eluting stent implantation in complex patients: An evaluation from the Rapamycin-Eluting Stent Evaluated at Rotterdam Cardiology Hospital (RESEARCH) study. Circulation 2004; 109: 1366-1370.
    • (2004) Circulation , vol.109 , pp. 1366-1370
    • Lemos, P.A.1    Hoye, A.2    Goedhart, D.3    Arampatzis, C.A.4    Saia, F.5    van der Giessen, W.J.6
  • 17
    • 19944369733 scopus 로고    scopus 로고
    • For the SIRIUS investigators. Quantitative assessment of angiographic restenosis after sirolimus-eluting stent implantation in native coronary arteries
    • Popma JJ, Leon MB, Moses JW, Holmes DR, Cox N, Fitzpatrick M, et al. for the SIRIUS investigators. Quantitative assessment of angiographic restenosis after sirolimus-eluting stent implantation in native coronary arteries. Circulation 2004; 110: 3773-3780.
    • (2004) Circulation , vol.110 , pp. 3773-3780
    • Popma, J.J.1    Leon, M.B.2    Moses, J.W.3    Holmes, D.R.4    Cox, N.5    Fitzpatrick, M.6
  • 18
    • 79960789427 scopus 로고    scopus 로고
    • J-Cypher Registry Investigators. Impact of multiple and long sirolimus-eluting stent implantation on 3-year clinical outcomes in the j-cypher registry
    • Shirai S, Kimura T, Nobuyoshi M, Morimoto T, Ando K, j-Cypher Registry Investigators. Impact of multiple and long sirolimus-eluting stent implantation on 3-year clinical outcomes in the j-cypher registry. J Am Coll Cardiol Intv 2009; 2: 97-106.
    • (2009) J Am Coll Cardiol Intv , vol.2 , pp. 97-106
    • Shirai, S.1    Kimura, T.2    Nobuyoshi, M.3    Morimoto, T.4    Ando, K.5    Soga, Y.6
  • 19
    • 77950640712 scopus 로고    scopus 로고
    • A 3-year clinical outcome after percutaneous coronary intervention using sirolimus-eluting stent and off-pump coronary artery bypass grafting for the treatment of diabetic patients with multivessel disease
    • Yamagata K, Kataoka Y, Kokubu N, Kasahara Y, Abe M, Nakajima H, et al. A 3-year clinical outcome after percutaneous coronary intervention using sirolimus-eluting stent and off-pump coronary artery bypass grafting for the treatment of diabetic patients with multivessel disease. Circ J 2010; 74: 671-678.
    • (2010) Circ J , vol.74 , pp. 671-678
    • Yamagata, K.1    Kataoka, Y.2    Kokubu, N.3    Kasahara, Y.4    Abe, M.5    Nakajima, H.6
  • 20
    • 39849084996 scopus 로고    scopus 로고
    • Sirolimus-eluting stents vs bare metal stents for coronary intervention in Japanese patients with renal failure on hemodialysis
    • Aoyama T, Ishii H, Toriyama T, Takahashi H, Kasuga H, Murakami R, et al. Sirolimus-eluting stents vs bare metal stents for coronary intervention in Japanese patients with renal failure on hemodialysis. Circ J 2008; 72: 56-60.
    • (2008) Circ J , vol.72 , pp. 56-60
    • Aoyama, T.1    Ishii, H.2    Toriyama, T.3    Takahashi, H.4    Kasuga, H.5    Murakami, R.6
  • 21
    • 73249140950 scopus 로고    scopus 로고
    • Clinical outcomes of sirolimus-eluting stenting after rotational atherectomy
    • Tamekiyo H, Hayashi Y, Toyofuku M, Ueda H, Sakuma T, Okimoto T, et al. Clinical outcomes of sirolimus-eluting stenting after rotational atherectomy. Circ J 2009; 73: 2042-2049.
    • (2009) Circ J , vol.73 , pp. 2042-2049
    • Tamekiyo, H.1    Hayashi, Y.2    Toyofuku, M.3    Ueda, H.4    Sakuma, T.5    Okimoto, T.6
  • 22
    • 34948830243 scopus 로고    scopus 로고
    • Impact of drug-eluting stents on clinical and angiographic outcomes in dialysis patients
    • Ishio N, Kobayashi Y, Takebayashi H, Iijima Y, Kanda J, Nakayama T, et al. Impact of drug-eluting stents on clinical and angiographic outcomes in dialysis patients. Circ J 2007; 71: 1525-1529.
    • (2007) Circ J , vol.71 , pp. 1525-1529
    • Ishio, N.1    Kobayashi, Y.2    Takebayashi, H.3    Iijima, Y.4    Kanda, J.5    Nakayama, T.6
  • 23
    • 70349868382 scopus 로고    scopus 로고
    • Significant association of coronary artery calcification in stent delivery route with restenosis after sirolimus-eluting stent implantation
    • Mori S, Yasuda S, Kataoka Y, Morii I, Kawamura A, Miyazaki S. Significant association of coronary artery calcification in stent delivery route with restenosis after sirolimus-eluting stent implantation. Circ J 2009; 73: 1856-1863.
    • (2009) Circ J , vol.73 , pp. 1856-1863
    • Mori, S.1    Yasuda, S.2    Kataoka, Y.3    Morii, I.4    Kawamura, A.5    Miyazaki, S.6
  • 24
    • 3042734510 scopus 로고    scopus 로고
    • Decreased number and impaired angiogenic function of endothelial progenitor cells in patients with chronic renal failure
    • Choi JH, Kim KL, Huh W, Kim B, Byun J, Suh W, et al. Decreased number and impaired angiogenic function of endothelial progenitor cells in patients with chronic renal failure. Arterioscler Thromb Vasc Biol 2004; 24: 1246-1252.
    • (2004) Arterioscler Thromb Vasc Biol , vol.24 , pp. 1246-1252
    • Choi, J.H.1    Kim, K.L.2    Huh, W.3    Kim, B.4    Byun, J.5    Suh, W.6
  • 25
    • 0022571233 scopus 로고
    • Enhanced in vitro platelet aggregation in hemodialysis patients
    • Viener A, Aviram M, Better OS, Brook JG. Enhanced in vitro platelet aggregation in hemodialysis patients. Nephron 1986; 43: 139-143.
    • (1986) Nephron , vol.43 , pp. 139-143
    • Viener, A.1    Aviram, M.2    Better, O.S.3    Brook, J.G.4
  • 26
    • 0033578471 scopus 로고    scopus 로고
    • In vivo assessment of stent expansion and recoil in normal porcine coronary arteries: Differential outcome by stent design
    • Carrozza JP Jr, Hosley SE, Cohen DJ, Baim DS. In vivo assessment of stent expansion and recoil in normal porcine coronary arteries: Differential outcome by stent design. Circulation 1999; 100: 756-760.
    • (1999) Circulation , vol.100 , pp. 756-760
    • Carrozza Jr., J.P.1    Hosley, S.E.2    Cohen, D.J.3    Baim, D.S.4
  • 27
    • 4344654100 scopus 로고    scopus 로고
    • Chronic stent recoil plays an important role in restenosis of the right coronary ostium
    • Tsunoda T, Nakamura M, Wada M, Ito N, Kitagawa Y, Shiba M, et al. Chronic stent recoil plays an important role in restenosis of the right coronary ostium. Coron Artery Dis 2004; 15: 39-44.
    • (2004) Coron Artery Dis , vol.15 , pp. 39-44
    • Tsunoda, T.1    Nakamura, M.2    Wada, M.3    Ito, N.4    Kitagawa, Y.5    Shiba, M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.