메뉴 건너뛰기




Volumn 82, Issue 4, 2011, Pages 184-188

Evaluation of the state of the insulation system of a stator winding of high-voltage electric machines based on measurements of statistical characteristics of partial discharges

Author keywords

Distribution; Flaw; Identification sign; Partial discharge; Stator winding insulation

Indexed keywords

ARTIFICIAL FLAWS; DISTRIBUTION; ELECTRICAL MACHINE; FLAW; HIGH-VOLTAGES; INSULATION SYSTEM; SEMI-CONDUCTING COATINGS; STATISTICAL CHARACTERISTICS; STATISTICAL PARAMETERS; STATOR WINDING; STATOR WINDING INSULATION;

EID: 79960762469     PISSN: 10683712     EISSN: None     Source Type: Journal    
DOI: 10.3103/S1068371211040031     Document Type: Article
Times cited : (2)

References (6)
  • 3
    • 0026192457 scopus 로고
    • Exploitation problems of high-voltage insulation in stator windings operating in the air
    • Vakser, B.D., Kogan, V.O., and Chernyavskii, V.P., Exploitation Problems of High-Voltage Insulation in Stator Windings Operating in the Air, Elektrotekhn., 1991, no. 7, pp. 42-47.
    • (1991) Elektrotekhn , Issue.7 , pp. 42-47
    • Vakser, B.D.1    Kogan, V.O.2    Chernyavskii, V.P.3
  • 6
    • 79960831772 scopus 로고    scopus 로고
    • International Standard no. IEC 60270: High-Voltage Test Techniques. Partial Discharge Measurements
    • International Standard no. IEC 60270: High-Voltage Test Techniques. Partial Discharge Measurements, 2000.
    • (2000)