Volumn 43, Issue 9, 2011, Pages 2429-2441

Sensitivity analysis of predicted night cooling performance to internal convective heat transfer modelling

Author keywords

Building energy simulation; Internal convective heat transfer; Night cooling; Sensitivity analysis

Indexed keywords

ARBITRARY CORRELATION; BELGIUM; BUILDING DESIGN; BUILDING ENCLOSURE; BUILDING ENERGY SIMULATIONS; CONVECTION CORRELATION; CONVECTIVE HEAT TRANSFER; CONVECTIVE HEAT TRANSFER COEFFICIENT; COOLING PERFORMANCE; DESIGN PARAMETERS; ENERGY SIMULATION; FLOW REGIMES; MODERATE CLIMATE; NIGHT COOLING; PASSIVE COOLING TECHNIQUES; SIMULATION RESULT;

EID: 79960738550     PISSN: 03787788     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.enbuild.2011.05.033     Document Type: Article
Times cited : (39)

References (39)
  • 1
    • 0036680185 scopus 로고    scopus 로고
    • Assessing energy, lighting, room acoustics, occupant comfort and environmental impacts performance of building with a single simulation program
    • S. Citherlet, and J. Hand Assessing energy, lighting, room acoustics, occupant comfort and environmental impacts performance of building with a single simulation program Building and Environment 37 8-9 2002 845 856
    • (2002) Building and Environment , vol.37 , Issue.89 , pp. 845-856
    • Citherlet, S.1    Hand, J.2
  • 2
    • 71649099069 scopus 로고    scopus 로고
    • On coupling 1D non-isothermal heat and mass transfer in porous materials with a multizone building energy simulation model
    • M. Steeman, A. Janssens, H.J. Steeman, M. Van Belleghem, and M. De Paepe On coupling 1D non-isothermal heat and mass transfer in porous materials with a multizone building energy simulation model Building and Environment 45 4 2010 865 877
    • (2010) Building and Environment , vol.45 , Issue.4 , pp. 865-877
    • Steeman, M.1    Janssens, A.2    Steeman, H.J.3    Van Belleghem, M.4    De Paepe, M.5
  • 6
    • 79960721822 scopus 로고    scopus 로고
    • NBN, NBN E N ISO 13791: Thermal performance of buildings - Internal temperatures in summer of a room without mechanical cooling - General criteria and calculation procedures, Brussels, 2008
    • NBN, NBN E N ISO 13791: Thermal performance of buildings - Internal temperatures in summer of a room without mechanical cooling - General criteria and calculation procedures, Brussels, 2008.
  • 9
    • 0030143443 scopus 로고    scopus 로고
    • The U.K. Applicability Study: An Evaluation of Thermal Simulation Programs for Passive Solar House Design
    • DOI 10.1016/0360-1323(95)00050-X, PII 036013239500050X
    • K.J. Lomas The UK Applicability Study: an evaluation of thermal simulation programs for passive solar house design Building and Environment 31 3 1996 197 206 (Pubitemid 126403251)
    • (1996) Building and Environment , vol.31 , Issue.3 , pp. 197-206
    • Lomas, K.J.1
  • 11
    • 49349090894 scopus 로고    scopus 로고
    • Parameter study on performance of building cooling by night-time ventilation
    • N. Artmann, H. Manz, and P. Heiselberg Parameter study on performance of building cooling by night-time ventilation Renewable Energy 33 12 2008 2589 2598
    • (2008) Renewable Energy , vol.33 , Issue.12 , pp. 2589-2598
    • Artmann, N.1    Manz, H.2    Heiselberg, P.3
  • 12
    • 0031281983 scopus 로고    scopus 로고
    • Night ventilation for building cooling in summer
    • DOI 10.1016/S0038-092X(97)00076-5, PII S0038092X97000765
    • P. Blondeau, M. Sperandio, and F. Allard Night ventilation for building cooling in summer Solar Energy 61 5 1997 327 335 (Pubitemid 27526597)
    • (1997) Solar Energy , vol.61 , Issue.5 , pp. 327-335
    • Blondeau, P.1    Sperandio, M.2    Allard, F.3
  • 14
    • 0033311825 scopus 로고    scopus 로고
    • Cooling-energy reduction in air-conditioned offices by using night ventilation
    • DOI 10.1016/S0306-2619(99)00031-8
    • M. Kolokotroni, and A. Aronis Cooling-energy reduction in air-conditioned offices by using night ventilation Applied Energy 63 4 1999 241 253 (Pubitemid 30504864)
    • (1999) Applied energy , vol.63 , Issue.4 , pp. 241-253
    • Kolokotroni, M.1    Aronis, A.2
  • 15
    • 0032141520 scopus 로고    scopus 로고
    • Effectiveness of mass and night ventilation in lowering the indoor daytime temperatures. Part I: 1993 experimental periods
    • PII S037877889700056X
    • B. Givoni Effectiveness of mass and night ventilation in lowering the indoor daytime temperatures. Part I: 1993 experimental periods Energy and Buildings 28 1 1998 25 32 (Pubitemid 128401550)
    • (1998) Energy and Buildings , vol.28 , Issue.1 , pp. 25-32
    • Givoni, B.1
  • 16
    • 0035284218 scopus 로고    scopus 로고
    • Natural convective heat transfer coefficient - A review II. Surfaces in two- and three-dimensional enclosures
    • A.J.N. Khalifa Natural convective heat transfer coefficient - a review II. Surfaces in two- and three-dimensional enclosures Energy Conversion and Management 42 4 2001 505 517
    • (2001) Energy Conversion and Management , vol.42 , Issue.4 , pp. 505-517
    • Khalifa, A.J.N.1
  • 18
    • 0025503424 scopus 로고
    • Validation of heat transfer coefficients on interior buildings surfaces using a real-sized indoor test cell
    • A.J.N. Khalifa, and R.H. Marshall Validation of heat transfer coefficients on interior buildings surfaces using a real-sized indoor test cell International Journal of Heat and Mass Transfer 33 10 1990 2219 2236
    • (1990) International Journal of Heat and Mass Transfer , vol.33 , Issue.10 , pp. 2219-2236
    • Khalifa, A.J.N.1    Marshall, R.H.2
  • 20
    • 0033311659 scopus 로고    scopus 로고
    • Natural convection from heated room surfaces
    • DOI 10.1016/S0378-7788(99)00004-3
    • H.B. Awbi, and A. Hatton Natural convection from heated room surfaces Energy and Buildings 30 3 1999 233 244 (Pubitemid 30509851)
    • (1999) Energy and Buildings , vol.30 , Issue.3 , pp. 233-244
    • Awbi, H.B.1    Hatton, A.2
  • 21
    • 0033750232 scopus 로고    scopus 로고
    • Mixed convection from heated room surfaces
    • H.B. Awbi, and A. Hatton Mixed convection from heated room surfaces Energy and Buildings 32 2 2000 153 166
    • (2000) Energy and Buildings , vol.32 , Issue.2 , pp. 153-166
    • Awbi, H.B.1    Hatton, A.2
  • 22
    • 0025795888 scopus 로고
    • Interior convective heat transfer in buildings with large ventilative flow rates
    • J.D. Spitler, C.O. Pedersen, and D.E. Fisher Interior convective heat transfer in buildings with large ventilative flow rates ASHRAE Transactions 97 Pt 1 1991 505 515 (Pubitemid 21725948)
    • (1991) ASHRAE Transactions , Issue.PART 1 , pp. 505-515
    • Spitler, J.D.1    Pedersen, C.O.2    Fisher, D.E.3
  • 23
    • 0025813841 scopus 로고
    • Experimental facility for investigation of interior convective heat transfer
    • J.D. Spitler, C.O. Pedersen, D.E. Fisher, P.F. Menne, and J. Cantillo An experimental facility for investigation of interior convective heat transfer ASHRAE Transactions 97 Pt 1 1991 497 504 (Pubitemid 21725949)
    • (1991) ASHRAE Transactions , Issue.PART 1 , pp. 497-504
    • Spitler, J.D.1    Pedersen, C.O.2    Fisher, D.E.3    Menne, P.F.4    Cantillo, J.5
  • 25
    • 0031370532 scopus 로고    scopus 로고
    • Convective heat transfer in building energy and thermal load calculations
    • D.E. Fisher, and C.O. Pederson Convective heat transfer in building energy and thermal load calculations ASHRAE Transactions 103 2 1997 137 148
    • (1997) ASHRAE Transactions , vol.103 , Issue.2 , pp. 137-148
    • Fisher, D.E.1    Pederson, C.O.2
  • 27
    • 79251646108 scopus 로고
    • General expression for correlation of rates of transfer and other phenomena
    • S.W. Churchill, and R. Usagi General expression for correlation of rates of transfer and other phenomena AICHE Journal 18 6 1972 1121 1128
    • (1972) AICHE Journal , vol.18 , Issue.6 , pp. 1121-1128
    • Churchill, S.W.1    Usagi, R.2
  • 28
    • 0032300788 scopus 로고    scopus 로고
    • The influence of sun patches on buoyancy-driven air movement and heat transfer within a passive solar test cell
    • P. Arnold, G.P. Hammond, A. Irving, and C. Martin The influence of sun patches on buoyancy-driven air movement and heat transfer within a passive solar test cell Proceedings of ASME Heat Transfer Division 361 1 1998 47 57
    • (1998) Proceedings of ASME Heat Transfer Division , vol.361 , Issue.1 , pp. 47-57
    • Arnold, P.1    Hammond, G.P.2    Irving, A.3    Martin, C.4
  • 29
    • 0023346739 scopus 로고
    • Experimental study of high rayleigh number mixed convection in a rectangular enclosure with restricted inlet and outlet openings
    • L. Neiswanger, G.A. Johnson, and V.P. Carey An experimental study of high Rayleigh number mixed convection in a rectangular enclosure with restricted inlet and outlet openings, Transactions of the ASME Journal of Heat Transfer 109 2 1987 446 453 (Pubitemid 17604776)
    • (1987) Journal of Heat Transfer , vol.109 , Issue.2 , pp. 446-453
    • Neiswanger, L.1    Johnson, G.A.2    Carey, V.P.3
  • 31
    • 77954312607 scopus 로고    scopus 로고
    • Performance evaluation of passive cooling in office buildings based on uncertainty and sensitivity analysis
    • H. Breesch, and A. Janssens Performance evaluation of passive cooling in office buildings based on uncertainty and sensitivity analysis Solar Energy 84 8 2010 1453 1467
    • (2010) Solar Energy , vol.84 , Issue.8 , pp. 1453-1467
    • Breesch, H.1    Janssens, A.2
  • 35
    • 79960743247 scopus 로고    scopus 로고
    • Air tightness of French dwellings: Results from field measurement studies
    • AIVC, The Hague
    • A. Litvak, M. Kilberger, K. Guillot, and D. Boze Air tightness of French dwellings: results from field measurement studies 21th AIVC Annual Conference AIVC, The Hague 2000
    • (2000) 21th AIVC Annual Conference
    • Litvak, A.1    Kilberger, M.2    Guillot, K.3    Boze, D.4
  • 37
    • 0034197005 scopus 로고    scopus 로고
    • Heat gain from office equipment
    • P. Wilkins, and M. Hosni Heat gain from office equipment ASHRAE Journal 42 6 2000 33 43
    • (2000) ASHRAE Journal , vol.42 , Issue.6 , pp. 33-43
    • Wilkins, P.1    Hosni, M.2
  • 38
    • 0036680682 scopus 로고    scopus 로고
    • Thermal indoor climate building performance characterized by human comfort response
    • DOI 10.1016/S0378-7788(01)00144-X, PII S037877880100144X
    • K. van der Linden, A.C. Boerstra, A.K. Raue, and S.R. Kurvers Thermal indoor climate building performance characterized by human comfort response Energy and Buildings 34 7 2002 737 744 (Pubitemid 34532367)
    • (2002) Energy and Buildings , vol.34 , Issue.7 , pp. 737-744
    • Van Der Linden, K.1    Boerstra, A.C.2    Raue, A.K.3    Kurvers, S.R.4
  • 39
    • 26844483865 scopus 로고    scopus 로고
    • Adaptive temperature limits: A new guideline in the Netherlands: A new approach for the assessment of building performance with respect to thermal indoor climate
    • DOI 10.1016/j.enbuild.2005.02.008, PII S0378778805000460
    • A.C. van der Linden, A.C. Boerstra, A.K. Raue, S.R. Kurvers, and R.J. de Dear Adaptive temperature limits: a new guideline in The Netherlands: a new approach for the assessment of building performance with respect to thermal indoor climate Energy and Buildings 38 1 2006 8 17 (Pubitemid 41454938)
    • (2006) Energy and Buildings , vol.38 , Issue.1 , pp. 8-17
    • Van Der Linden, A.C.1    Boerstra, A.C.2    Raue, A.K.3    Kurvers, S.R.4    De Dear, R.J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.