Effects of double skin envelopes on natural ventilation and heating loads in office buildings

Author keywords

Airflow control; Double skin envelope; Energy savings; Heating load; Natural ventilation

Indexed keywords

AIR FLOW CONTROL; AIR FLOW-RATE; ALL-SKY; CAVITY TEMPERATURE; CLOUDY SKIES; DOUBLE SKIN; FIELD MEASUREMENT; HEATING LOAD; INDOOR SPACE; NATURAL VENTILATION; OUTDOOR AIR; OUTDOOR-AIR TEMPERATURE; REGRESSION MODEL; SAVING ENERGY; SKY CONDITION; SOLAR IRRADIANCES; SPACE BETWEEN; WEATHER CONDITIONS; WINTER MONTHS;

EID: 79960737824     PISSN: 03787788     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.enbuild.2011.04.012     Document Type: Article
Times cited : (49)

References (18)
  • 1
    • 35348880855 scopus 로고    scopus 로고
    • Determining photosensor conditions of a daylight dimming control system using different double-skin envelope configurations
    • DOI 10.1177/1420326X07082497
    • S. Kim, and K. Song Determining photosensor conditions of a daylight dimming control system using different double-skin envelope configurations Indoor and Built Environment 16 2007 411 425 (Pubitemid 47585177)
    • (2007) Indoor and Built Environment , vol.16 , Issue.5 , pp. 411-425
    • Kim, S.Y.1    Song, K.D.2
  • 2
    • 11144348087 scopus 로고    scopus 로고
    • The characteristics of photosensors and electronic dimming ballasts in daylight responsive dimming systems
    • DOI 10.1016/j.buildenv.2004.07.014, PII S0360132304001775
    • A. Choi, K. Song, and Y. Kim The characteristics of photosensor and electronic dimming in daylight responsive dimming systems Building and Environment 40 2005 39 50 (Pubitemid 40032260)
    • (2005) Building and Environment , vol.40 , Issue.1 , pp. 39-50
    • Choi, A.-S.1    Song, K.-D.2    Kim, Y.-S.3
  • 8
    • 67449143232 scopus 로고    scopus 로고
    • Contribution of natural ventilation in a double skin envelope to heating load reduction in winter
    • Y. Kim, S. Kim, S. Shin, and J. Sohn Contribution of natural ventilation in a double skin envelope to heating load reduction in winter Building and Environment 44 2009 2236 2244
    • (2009) Building and Environment , vol.44 , pp. 2236-2244
    • Kim, Y.1    Kim, S.2    Shin, S.3    Sohn, J.4
  • 9
    • 33947377941 scopus 로고    scopus 로고
    • Guidelines for improving natural daytime ventilation in an office building with a double-skin facade
    • DOI 10.1016/j.solener.2006.08.006, PII S0038092X06002015
    • E. Gratia, and A. Herde Guidelines for improving natural daytime ventilation in an office building with a double-skin faade Solar Energy 81 2007 435 448 (Pubitemid 46452703)
    • (2007) Solar Energy , vol.81 , Issue.4 , pp. 435-448
    • Gratia, E.1    De Herde, A.2
  • 11
    • 34248645679 scopus 로고    scopus 로고
    • The impact of daylight fluctuation on a daylight dimming control system in a small office
    • DOI 10.1016/j.enbuild.2006.10.009, PII S0378778806002623
    • S. Kim, and J. Kim The impact of daylight fluctuation on a daylight dimming control system in a small office Energy and Building 39 2007 935 944 (Pubitemid 46771039)
    • (2007) Energy and Buildings , vol.39 , Issue.8 , pp. 935-944
    • Kim, S.-Y.1    Kim, J.-J.2
  • 12
    • 47649107696 scopus 로고    scopus 로고
    • Development and validation of regression models to predict monthly heating demand for residential building
    • T. Catalina, J. Virgone, and E. Blanco Development and validation of regression models to predict monthly heating demand for residential building Energy and Buildings 40 2008 1825 1832
    • (2008) Energy and Buildings , vol.40 , pp. 1825-1832
    • Catalina, T.1    Virgone, J.2    Blanco, E.3
  • 13
    • 44449178361 scopus 로고    scopus 로고
    • Energy conservation in honey storage building using Trombe wall
    • DOI 10.1016/j.enbuild.2008.02.019, PII S0378778808000522
    • A. Chel, J. Hayak, and G. Kaushik Energy conservation in honey storage building using Trombe wall Energy and Buildings 40 2008 1643 1650 (Pubitemid 351756481)
    • (2008) Energy and Buildings , vol.40 , Issue.9 , pp. 1643-1650
    • Chel, A.1    Nayak, J.K.2    Kaushik, G.3
  • 14
    • 0038418480 scopus 로고    scopus 로고
    • A method for the direct generation of comprehensive numerical solar building transfer functions
    • DOI 10.1016/S0038-092X(03)00119-1
    • T. Chen A method for the direct generation of comprehensive numerical solar building transfer functions Solar Energy 74 2003 123 132 (Pubitemid 36797146)
    • (2003) Solar Energy , vol.74 , Issue.2 , pp. 123-132
    • Chen, T.Y.1
  • 15
    • 79960720622 scopus 로고    scopus 로고
    • ANSI/ASHRAE Atlanta, USA Standard 55-2004 A.
    • ANSI-ASHRAE Standard 55-2004 Thermal Conditions for Human Occupancy 2004 ANSI/ASHRAE Atlanta, USA
    • (2004) Thermal Conditions for Human Occupancy
  • 16
    • 79960726421 scopus 로고    scopus 로고
    • The Illuminating Engineering Society of North America
    • M. Rea IESNA Handbook 9th Editions 2002 The Illuminating Engineering Society of North America
    • (2002) IESNA Handbook 9th Editions
    • Rea, M.1
  • 17
    • 0242335863 scopus 로고    scopus 로고
    • Optimal operation of a south double-skin faade
    • E. Gratia, and A.D. Herde Optimal operation of a south double-skin faade Energy and Building 36 2004 41 60
    • (2004) Energy and Building , vol.36 , pp. 41-60
    • Gratia, E.1    Herde, A.D.2
  • 18
    • 33847637178 scopus 로고    scopus 로고
    • Are energy consumptions decreased with the addition of a double-skin?
    • DOI 10.1016/j.enbuild.2006.10.002, PII S0378778806002362
    • E. Gratia, and A.D. Herde Are energy consumption decreased with the addition of a double-skin Energy and Building 39 2007 605 619 (Pubitemid 46367935)
    • (2007) Energy and Buildings , vol.39 , Issue.5 , pp. 605-619
    • Gratia, E.1    De Herde, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.