메뉴 건너뛰기




Volumn 16, Issue , 2005, Pages 25-30

Imaging and control for adaptive radiotherapy

Author keywords

Control system design; Image processing; Medical applications; PID control; Robot

Indexed keywords

CONTROL SYSTEMS; IMAGE PROCESSING; MACHINE DESIGN; MEDICAL APPLICATIONS; MEDICAL IMAGING; MEDICAL ROBOTICS; RADIOTHERAPY; ROBOTS; THREE TERM CONTROL SYSTEMS;

EID: 79960735725     PISSN: 14746670     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.3182/20050703-6-cz-1902.02118     Document Type: Conference Paper
Times cited : (11)

References (26)
  • 1
    • 0942277196 scopus 로고    scopus 로고
    • Integrated radiotherapy imaging system (IRIS): Design considerations of tumour tracking with linac gantry-mounted diagnostic x-ray systems with flat-panel detectors
    • Berbeco, R.I., S.B. Jiang, G.C. Sharp, G.T. Chen, H. Mostafavi, H. Shirato (2004). Integrated radiotherapy imaging system (IRIS): design considerations of tumour tracking with linac gantry-mounted diagnostic x-ray systems with flat-panel detectors. Phys Med Biol, 49(2):243- 55.
    • (2004) Phys Med Biol , vol.49 , Issue.2 , pp. 243-255
    • Berbeco, R.I.1    Jiang, S.B.2    Sharp, G.C.3    Chen, G.T.4    Mostafavi, H.5    Shirato, H.6
  • 2
    • 23244467597 scopus 로고    scopus 로고
    • Fuzzy-snake segmentation of anatomical structures applied to CT images
    • Bueno G., Martínez-Albalá A., Adán A. (2004). Fuzzy-Snake Segmentation of Anatomical Structures Applied to CT Images, Lecture Notes in Computer Science; 3212(II), 33-42.
    • (2004) Lecture Notes in Computer Science , vol.3212 , Issue.2 , pp. 33-42
    • Bueno, G.1    Martínez-Albalá, A.2    Adán, A.3
  • 3
    • 79960726619 scopus 로고    scopus 로고
    • 3D segmentation of anatomical structures in MRIs on large data bases
    • Bueno G., Heitz F., Armspach JP. (2002). 3D Segmentation of Anatomical Structures in MRIs on Large Data Bases, Journal of Magnetic Resonance Imaging, 19(1), 73-81.
    • (2002) Journal of Magnetic Resonance Imaging , vol.19 , Issue.1 , pp. 73-81
    • Bueno, G.1    Heitz, F.2    Armspach, J.P.3
  • 5
    • 0142025618 scopus 로고    scopus 로고
    • Automatic registration of the prostate for computedtomography- Guided radiotherapy
    • Court, L.E. and L.Dong (2003). Automatic registration of the prostate for computedtomography- guided radiotherapy, Medical Physics 30, (10), 2750-2757.
    • (2003) Medical Physics , vol.30 , Issue.10 , pp. 2750-2757
    • Court, L.E.1    Dong, L.2
  • 6
    • 0033640668 scopus 로고    scopus 로고
    • Medical image analysis: Progress over two decades and the challenges ahead
    • Duncan J.S., Ayache N. (2000). Medical Image Analysis: Progress over Two Decades and the Challenges Ahead. IEEE Trans. PAMI 22, 85-106.
    • (2000) IEEE Trans. PAMI , vol.22 , pp. 85-106
    • Duncan, J.S.1    Ayache, N.2
  • 7
    • 0042322435 scopus 로고    scopus 로고
    • An intelligent oncology workstation for the 21st century
    • PL ISSN 0029-540X
    • Haas, O., 2003, an Intelligent Oncology Workstation for the 21st Century, Nowotwory Journal of oncology, Volume 53, Number 4, 389-397, PL ISSN 0029-540X.
    • (2003) Nowotwory Journal of Oncology , vol.53 , Issue.4 , pp. 389-397
    • Haas, O.1
  • 8
    • 0031686707 scopus 로고    scopus 로고
    • A tilt and roll device for automated correction of rotational setup errors
    • Hornick DC, Litzenberg DW, Kam KL, et al. A tilt and roll device for automated correction of rotational setup errors. Med Phys 1998;25:1739- 1740.
    • (1998) Med Phys , vol.25 , pp. 1739-1740
    • Hornick, D.C.1    Litzenberg, D.W.2    Kam, K.L.3
  • 10
    • 0028857468 scopus 로고
    • The use of an electronic portal imaging device for exit dosimetry and quality control measurements
    • Kirby, M.C., and P.C. Williams (1995). The use of an electronic portal imaging device for exit dosimetry and quality control measurements. Int J Radiat Oncol Biol Phys; 31, 593-603.
    • (1995) Int J Radiat Oncol Biol Phys , vol.31 , pp. 593-603
    • Kirby, M.C.1    Williams, P.C.2
  • 12
    • 0037443380 scopus 로고    scopus 로고
    • Ultrasound-guided extracranial radiosurgery: Technique and application
    • Meeks, S.L., J.M. Buatti, L.G. Bouchet, et al. (2003). Ultrasound-guided extracranial radiosurgery: technique and application, Int J Radiat Oncol Biol Phys 55(4), 1092-101.
    • (2003) Int J Radiat Oncol Biol Phys , vol.55 , Issue.4 , pp. 1092-1101
    • Meeks, S.L.1    Buatti, J.M.2    Bouchet, L.G.3
  • 13
    • 79960747456 scopus 로고    scopus 로고
    • accessed 15/07/04
    • NDI Polaris, http://www.ndigital.com, (accessed 15/07/04).
    • NDI Polaris
  • 14
    • 0037402511 scopus 로고    scopus 로고
    • A new irradiation system for lung cancer combining linear accelerator, computed tomography, patient self-breath-holding, and patient-directed beam-control without respiratory monitoring devices
    • Onishi, H., K. Kuriyama, T. Komiyama, et al. (2003). A new irradiation system for lung cancer combining linear accelerator, computed tomography, patient self-breath-holding, and patient-directed beam-control without respiratory monitoring devices. Int J Radiat Oncol Biol Phys;56(1), 14-20.
    • (2003) Int J Radiat Oncol Biol Phys , vol.56 , Issue.1 , pp. 14-20
    • Onishi, H.1    Kuriyama, K.2    Komiyama, T.3
  • 16
    • 1542610649 scopus 로고    scopus 로고
    • Tracking the dose distribution in radiation therapy by accounting for variable anatomy
    • Schaly, B., J.A. Kempe, G.S. Bauman, J.J.Battista, Van Dyk J. (2004). Tracking the dose distribution in radiation therapy by accounting for variable anatomy, Phys Med Biol, 49, 791- 805.
    • (2004) Phys Med Biol , vol.49 , pp. 791-805
    • Van, D.J.1    Schaly, B.2    Kempe, J.A.3    Bauman, G.S.4    Battista, J.J.5
  • 17
    • 4544375978 scopus 로고    scopus 로고
    • Three-dimensional conformal setup (3D-CSU) of patients using the coordinate system provided by three internal fiducial markers and two orthogonal diagnostic X-ray systems in the treatment room
    • Shirato, H., M. Oita, K. Fujita, S. et al. (2004). Three-dimensional conformal setup (3D-CSU) of patients using the coordinate system provided by three internal fiducial markers and two orthogonal diagnostic X-ray systems in the treatment room. Int J Radiat Oncol Biol Phys. 60(2), 607-612.
    • (2004) Int J Radiat Oncol Biol Phys , vol.60 , Issue.2 , pp. 607-612
    • Shirato, H.1    Oita, M.2    Fujita, K.S.3
  • 18
    • 0141504154 scopus 로고    scopus 로고
    • Near simultaneous computed tomography imageguided stereotactic spinal radiotherapy: An emerging paradigm for achieving true stereotaxy
    • Shiu, A.S., E.L. Chang, J.S. Ye, et al. (2003). Near simultaneous computed tomography imageguided stereotactic spinal radiotherapy: an emerging paradigm for achieving true stereotaxy. Int J Radiat Oncol Biol Phys. 57(3):605-13.
    • (2003) Int J Radiat Oncol Biol Phys , vol.57 , Issue.3 , pp. 605-613
    • Shiu, A.S.1    Chang, E.L.2    Ye, J.S.3
  • 19
    • 79960701625 scopus 로고    scopus 로고
    • (accessed 03- 02-2004)
    • SimMechanics, 2004, The MathWorks (accessed 03- 02-2004) http://www.mathworks.com/.
    • (2004) SimMechanics
  • 20
    • 4544290703 scopus 로고    scopus 로고
    • Automatic localization of the prostate for on-line or off-line image-guided radiotherapy
    • Smitsmans, M.H., J.W. Wolthaus, X. Artignan, J. et al. (2004). Automatic localization of the prostate for on-line or off-line image-guided radiotherapy. Int J Radiat Oncol Biol Phys, 60(2), 623-35.
    • (2004) Int J Radiat Oncol Biol Phys , vol.60 , Issue.2 , pp. 623-635
    • Smitsmans, M.H.1    Wolthaus, J.W.2    Artignan, X.J.3
  • 21
  • 22
    • 79960709568 scopus 로고    scopus 로고
    • Modelling and control of patient support system for radiotherapy
    • UK, ISBN 0 86197 130 2, 86 (abstract, CDROM)
    • Spriestersbach, R., O.C.L. Haas, K.J. Burnham, (2004) Modelling and control of patient support system for radiotherapy, Control 2004, Bath, UK, ISBN 0 86197 130 2, 86 (abstract, CDROM).
    • (2004) Control 2004, Bath
    • Spriestersbach, R.1    Haas, O.C.L.2    Burnham, K.J.3
  • 23
    • 0033984574 scopus 로고    scopus 로고
    • On-line setup corrections during radiotherapy of patients with gynecologic tumors
    • Stroom JC, Olofsen-van Acht MJJ, Quint S, et al. (2000). On-line setup corrections during radiotherapy of patients with gynecologic tumors. Int J Radiat Oncol Biol Phys;46, 499-506.
    • (2000) Int J Radiat Oncol Biol Phys , vol.46 , pp. 499-506
    • Stroom, J.C.1    Olofsen-Van Acht, M.J.J.2    Quint, S.3
  • 24
    • 0032171026 scopus 로고    scopus 로고
    • Variability of target volume delineation in cervical esophageal cancer
    • Tai, P., J.Van Dyk, E. Yu, et al. (1998). Variability of target volume delineation in cervical esophageal cancer. Int J Radiat Oncol Biol Phys, 42, 227-288.
    • (1998) Int J Radiat Oncol Biol Phys , vol.42 , pp. 227-288
    • Tai, P.1    Dyk, J.Van.2    Yu, E.3
  • 25
    • 79960740185 scopus 로고    scopus 로고
    • Respiratory motion tracking of skin and liver in swine for cyberknife motion compensation, medical imaging 2004
    • May 2004, Robert L. Galloway, Jr. (Ed) 5367, CDS118, ISBN 0-8194- 5295-5 (CDROM)
    • Tanga, J., S. Dieterichb, K. Clearya, (2004). Respiratory Motion Tracking of Skin and Liver in Swine for CyberKnife Motion Compensation, Medical Imaging 2004, May 2004, : Visualization, Image-Guided Procedures, and Display Robert L. Galloway, Jr. (Ed) 5367, CDS118, ISBN 0-8194- 5295-5 (CDROM).
    • (2004) Visualization, Image-Guided Procedures, and Display
    • Tanga, J.1    Dieterichb, S.2    Clearya, K.3
  • 26
    • 0034811788 scopus 로고    scopus 로고
    • Optically guided intensity modulated radiotherapy
    • Tomé, W.A., S.L. Meeks, T.R. McNutt et al. (2001). Optically guided intensity modulated radiotherapy. Radiother Oncol, 61, 33-44.
    • (2001) Radiother Oncol , vol.61 , pp. 33-44
    • Tomé, W.A.1    Meeks, S.L.2    McNutt, T.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.