메뉴 건너뛰기




Volumn 197, Issue 2, 2011, Pages 437-441

Image noise and liver lesion detection with MDCT: A phantom study

Author keywords

Automatic tube current modulation; Liver phantom; Low contrast lesion detection; MDCT; Noise index

Indexed keywords

AREA UNDER THE CURVE; ARTICLE; CONTRAST ENHANCEMENT; CONTROLLED STUDY; EXPERIMENTAL STUDY; IMAGE ANALYSIS; IMAGE QUALITY; LIVER INJURY; LIVER TUMOR; MULTIDETECTOR COMPUTED TOMOGRAPHY; PHANTOM; PRIORITY JOURNAL; RECEIVER OPERATING CHARACTERISTIC; SENSITIVITY ANALYSIS; SIGNAL NOISE RATIO;

EID: 79960708478     PISSN: 0361803X     EISSN: 15463141     Source Type: Journal    
DOI: 10.2214/AJR.10.5726     Document Type: Article
Times cited : (30)

References (11)
  • 1
    • 0028070216 scopus 로고
    • Understanding and optimizing use of contrast material for CT of the liver
    • Baron RL. Understanding and optimizing use of contrast material for CT of the liver. AJR 1994; 163:323-331 (Pubitemid 24242512)
    • (1994) American Journal of Roentgenology , vol.163 , Issue.2 , pp. 323-331
    • Baron, R.L.1
  • 2
    • 0036720964 scopus 로고    scopus 로고
    • Aortic and hepatic enhancement and tumor-to-liver contrast: Analysis of the effect of different concentrations of contrast material at multi-detector row helical CT
    • Awai K, Takada K, Onishi H, Hori S. Aortic and hepatic enhancement and tumor-to-liver-contrast: analysis of the effect of different concentrations of contrast material at multi-detector row helical CT. Radiology 2002; 224:757-763 (Pubitemid 34919809)
    • (2002) Radiology , vol.224 , Issue.3 , pp. 757-763
    • Awai, K.1    Takada, K.2    Onishi, H.3    Hori, S.4
  • 4
    • 34250823535 scopus 로고    scopus 로고
    • Impact of operator-selected image noise index and reconstruction slice thickness on patient radiation dose in 64-MDCT
    • DOI 10.2214/AJR.06.1524
    • Kanal KM, Stewart BK, Kolokythas O, Shuman WP. Impact of operator-selected image noise index and reconstruction slice thickness on patient radiation dose in 64-MDCT. AJR 2007; 189:219-225 (Pubitemid 46983214)
    • (2007) American Journal of Roentgenology , vol.189 , Issue.1 , pp. 219-225
    • Kanal, K.M.1    Stewart, B.K.2    Kolokythas, O.3    Shuman, W.P.4
  • 7
    • 0033858026 scopus 로고    scopus 로고
    • Detection of hepatocellular carcinomas and dysplastic nodules in cirrhotic livers: Accuracy of helical CT in transplant patients
    • Lim JH, Kim CK, Lee WJ, et al. Detection of hepatocellular carcinomas and dysplastic nodules in cirrhotic livers: accuracy of helical CT in transplant patients. AJR 2000; 175:693-698
    • (2000) AJR , vol.175 , pp. 693-698
    • Lim, J.H.1    Kim, C.K.2    Lee, W.J.3
  • 8
    • 4644221703 scopus 로고    scopus 로고
    • Sixteen-detector row CT of abdomen and pelvis: Study for optimization of z-axis modulation technique performed in 153 patients
    • DOI 10.1148/radiol.2331031505
    • Kalra MK, Maher MM, Kamath RS, et al. Sixteen-detector row CT of abdomen and pelvis: study for optimization of z-axis modulation technique performed in 153 patients. Radiology 2004; 233:241-249 (Pubitemid 39280980)
    • (2004) Radiology , vol.233 , Issue.1 , pp. 241-249
    • Kalra, M.K.1    Maher, M.M.2    Kamath, R.S.3    Horiuchi, T.4    Toth, T.L.5    Halpern, E.F.6    Saini, S.7
  • 9
    • 4143148392 scopus 로고    scopus 로고
    • Detection and characterization of lesions on low-radiation-dose abdominal CT images postprocessed with noise reduction filters
    • DOI 10.1148/radiol.2323031563
    • Kalra MK, Maher MM, Blake MA, et al. Detection and characterization of lesions on low-radiation-dose abdominal CT images postprocessed with noise reduction filters. Radiology 2004; 232:791-797 (Pubitemid 39100265)
    • (2004) Radiology , vol.232 , Issue.3 , pp. 791-797
    • Kalra, M.K.1    Maher, M.M.2    Blake, M.A.3    Lucey, B.C.4    Karau, K.5    Toth, T.L.6    Avinash, G.7    Halpern, E.F.8    Saini, S.9
  • 11
    • 27744559376 scopus 로고    scopus 로고
    • Radiation dose reduction without degradation of low-contrast detectability at abdominal multisection CT with a low-tube voltage technique: Phantom study
    • DOI 10.1148/radiol.2373041643
    • Funama Y, Awai K, Nakayama Y, et al. Radiation dose reduction without degradation of low-contrast detectability at abdominal multisection CT with a low-tube voltage technique: phantom study. Radiology 2005; 237:905-910 (Pubitemid 41636380)
    • (2005) Radiology , vol.237 , Issue.3 , pp. 905-910
    • Funama, Y.1    Awai, K.2    Nakayama, Y.3    Kakei, K.4    Nagasue, N.5    Shimamura, M.6    Sato, N.7    Sultana, S.8    Morishita, S.9    Yamashita, Y.10


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.