메뉴 건너뛰기




Volumn 211, Issue 2, 2011, Pages 156-161

Rapid frequency scan EPR

Author keywords

Digital detection; Fourier deconvolution; Periodic excitation; Polyphase excitation

Indexed keywords

ARBITRARY WAVEFORM GENERATOR; CROSS-LOOP; DIGITAL DETECTION; EPR SPECTRA; EXCITATION METHODS; EXTERNAL MAGNETIC FIELD; FOURIER DECONVOLUTION; FREQUENCY SCANS; PEAK POWER; PERIODIC EXCITATIONS; POLYPHASE EXCITATION; PULSED EPR; SAW-TOOTH; TRIANGULAR SCANS; WAVE FORMS;

EID: 79960700443     PISSN: 10907807     EISSN: 10960856     Source Type: Journal    
DOI: 10.1016/j.jmr.2011.05.006     Document Type: Article
Times cited : (25)

References (24)
  • 5
    • 19944405163 scopus 로고    scopus 로고
    • Rapid-scan EPR with triangular scans and fourier deconvolution to recover the slow-scan spectrum
    • DOI 10.1016/j.jmr.2005.03.013, PII S1090780705001102
    • J.P. Joshi, J.R. Ballard, G.A. Rinard, R.W. Quine, S.S. Eaton, and G.R. Eaton Rapid-scan EPR with triangular scans and Fourier deconvolution to recover the slow-scan spectrum J. Magn. Reson. 175 2005 44 51 (Pubitemid 40753506)
    • (2005) Journal of Magnetic Resonance , vol.175 , Issue.1 , pp. 44-51
    • Joshi, J.P.1    Ballard, J.R.2    Rinard, G.A.3    Quine, R.W.4    Eaton, S.S.5    Eaton, G.R.6
  • 6
    • 24944435918 scopus 로고    scopus 로고
    • Impact of resonator on direct-detected rapid-scan EPR at 9.8 GHz
    • J.P. Joshi, G.R. Eaton, and S.S. Eaton Impact of resonator on direct-detected rapid-scan EPR at 9.8 GHz Appl. Magn. Reson. 29 2005 239 249 (Pubitemid 41301751)
    • (2005) Applied Magnetic Resonance , vol.28 , Issue.3-4 , pp. 239-249
    • Joshi, J.P.1    Eaton, G.R.2    Eaton, S.S.3
  • 9
    • 0024819978 scopus 로고
    • Frequency-sweep ESR spectrometer for dosimetry and dating
    • DOI 10.1016/0883-2889(89)90004-X
    • H. Hara, and M. Ikeya Frequency-sweep ESR spectrometer for dosimetry and dating Appl. Radiat. Isot. 40 1989 841 843 (Pubitemid 20071783)
    • (1989) Applied Radiation and Isotopes , vol.40 , Issue.10-12 , pp. 841-843
    • Hara, H.1    Ikeya, M.2
  • 13
    • 79960697842 scopus 로고    scopus 로고
    • Use of polyphase continuous excitation based on the Frank sequence for EPR and EPR Imaging
    • submitted for publication
    • M. Tseitlin, R.W. Quine, S.S. Eaton, G.R. Eaton, Use of polyphase continuous excitation based on the Frank sequence for EPR and EPR Imaging, J. Magn. Reson., submitted for publication.
    • J. Magn. Reson.
    • Tseitlin, M.1    Quine, R.W.2    Eaton, S.S.3    Eaton, G.R.4
  • 14
  • 15
    • 0008757537 scopus 로고
    • Correlation NMR spectroscopy
    • J. Dadok, and R.F. Sprecher Correlation NMR spectroscopy J. Magn. Reson. 13 1974 243 248
    • (1974) J. Magn. Reson. , vol.13 , pp. 243-248
    • Dadok, J.1    Sprecher, R.F.2
  • 16
    • 4243905937 scopus 로고
    • Preparation and study of a lithium phthalocyanine radical: Optical and magnetic properties
    • P. Turek, J.J. Andre, A. Giraudeau, and J. Simon Preparation and study of a lithium phthalocyanine radical: optical and magnetic properties Chem. Phys. Lett. 134 1987 471 476
    • (1987) Chem. Phys. Lett. , vol.134 , pp. 471-476
    • Turek, P.1    Andre, J.J.2    Giraudeau, A.3    Simon, J.4
  • 18
    • 0034183382 scopus 로고    scopus 로고
    • An L-Band crossed-loop (bimodal) EPR resonator
    • G.A. Rinard, R.W. Quine, and G.R. Eaton An L-Band crossed-loop (bimodal) EPR resonator J. Magn. Reson. 144 2000 85 88
    • (2000) J. Magn. Reson. , vol.144 , pp. 85-88
    • Rinard, G.A.1    Quine, R.W.2    Eaton, G.R.3
  • 19
    • 18544378120 scopus 로고    scopus 로고
    • 250 MHz crossed loop resonator for pulsed electron paramagnetic resonance
    • G.A. Rinard, R.W. Quine, G.R. Eaton, and S.S. Eaton 250 MHz crossed loop resonator for pulsed electron paramagnetic resonance Magn. Reson. Eng. 15 2002 37 46
    • (2002) Magn. Reson. Eng. , vol.15 , pp. 37-46
    • Rinard, G.A.1    Quine, R.W.2    Eaton, G.R.3    Eaton, S.S.4
  • 20
    • 79953196413 scopus 로고    scopus 로고
    • Reconstruction of the first derivative EPR spectrum from multiple harmonics of the field-modulated CW signal
    • M. Tseitlin, S.S. Eaton, and G.R. Eaton Reconstruction of the first derivative EPR spectrum from multiple harmonics of the field-modulated CW signal J. Magn. Reson. 209 2011 277 281
    • (2011) J. Magn. Reson. , vol.209 , pp. 277-281
    • Tseitlin, M.1    Eaton, S.S.2    Eaton, G.R.3
  • 21
    • 78649451571 scopus 로고    scopus 로고
    • Digital detection and processing of multiple quadrature harmonics for EPR spectroscopy
    • R. Ahmad, S. Som, E. Kesselring, P. Kuppusamy, J.L. Zweier, and L.C. Potter Digital detection and processing of multiple quadrature harmonics for EPR spectroscopy J. Magn. Reson. 207 2010 322 331
    • (2010) J. Magn. Reson. , vol.207 , pp. 322-331
    • Ahmad, R.1    Som, S.2    Kesselring, E.3    Kuppusamy, P.4    Zweier, J.L.5    Potter, L.C.6
  • 22
    • 70350602529 scopus 로고    scopus 로고
    • Using of digital demodulation of multiharmonic overmodulated EPR signals to improve EPR oximetry reliability
    • M.P. Tseitlin, and O.A. Tseitlin Using of digital demodulation of multiharmonic overmodulated EPR signals to improve EPR oximetry reliability Appl. Magn. Reson. 36 2009 25 34
    • (2009) Appl. Magn. Reson. , vol.36 , pp. 25-34
    • Tseitlin, M.P.1    Tseitlin, O.A.2
  • 24
    • 65749088040 scopus 로고    scopus 로고
    • Advantages of digital phase-sensitive detection for upgrading an obsolete CW EPR spectrometer
    • M. Tseitlin, V.S. Iyudin, and O.A. Tseitlin Advantages of digital phase-sensitive detection for upgrading an obsolete CW EPR spectrometer Appl. Magn. Reson. 35 2009 569 580
    • (2009) Appl. Magn. Reson. , vol.35 , pp. 569-580
    • Tseitlin, M.1    Iyudin, V.S.2    Tseitlin, O.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.