Dynamic response of liquid-filled catheter systems for measurement of blood pressure: Precision of measurements and reliability of the Pressure Recording Analytical Method with different disposable systems

Author keywords

Cardiac Output; DP dtMAX; MostCare; PRAM; Pulse contour method; R.O.S.E.; Underdamping

Indexed keywords

AGED; ANALYTIC METHOD; ARTERIAL PRESSURE; ARTICLE; ARTIFACT REDUCTION; BLOOD PRESSURE MEASUREMENT; CLINICAL ARTICLE; CONTROLLED STUDY; DISPOSABLE EQUIPMENT; HEART CATHETERIZATION; HEART CYCLE; HEART INDEX; HEMODYNAMICS; HUMAN; INTERMETHOD COMPARISON; ITALY; PRESSURE TRANSDUCER; PROSPECTIVE STUDY; RELIABILITY; SYSTOLIC BLOOD PRESSURE;

EID: 79960700363     PISSN: 08839441     EISSN: 15578615     Source Type: Journal    
DOI: 10.1016/j.jcrc.2010.08.010     Document Type: Article
Times cited : (44)

References (25)
  • 1
    • 0019523842 scopus 로고
    • Direct blood pressure measurement-dynamic response requirements
    • Gardner R.M. Direct blood pressure measurement-dynamic response requirements. Anesthesiology 1981, 54:227-236.
    • (1981) Anesthesiology , vol.54 , pp. 227-236
    • Gardner, R.M.1
  • 2
    • 0023786403 scopus 로고
    • Frequency response evaluation of radial artery catheter--manometer systems: sinusoidal frequency analysis versus flush method
    • Schwid H.A. Frequency response evaluation of radial artery catheter--manometer systems: sinusoidal frequency analysis versus flush method. J Clin Monit 1988, 4:181-185.
    • (1988) J Clin Monit , vol.4 , pp. 181-185
    • Schwid, H.A.1
  • 4
    • 33746761661 scopus 로고    scopus 로고
    • Continuous cardiac output monitoring in humans by invasive and noninvasive peripheral blood pressure waveform analysis
    • Lu Z., Mukkamala R. Continuous cardiac output monitoring in humans by invasive and noninvasive peripheral blood pressure waveform analysis. J Appl Physiol. 2006, 101:598-608.
    • (2006) J Appl Physiol. , vol.101 , pp. 598-608
    • Lu, Z.1    Mukkamala, R.2
  • 5
    • 74049117529 scopus 로고    scopus 로고
    • Estimation of hemodynamic parameters by arterial waveform: available technologies
    • Romagnoli S., Romano S.M. Estimation of hemodynamic parameters by arterial waveform: available technologies. Anesth Analg 2010, 110:257-258.
    • (2010) Anesth Analg , vol.110 , pp. 257-258
    • Romagnoli, S.1    Romano, S.M.2
  • 6
    • 44049083321 scopus 로고    scopus 로고
    • Arterial pressure-based cardiac output assessment
    • Maus T.M., Lee D.E. Arterial pressure-based cardiac output assessment. J Cardiothorac Vasc Anesth 2008, 22:468-473.
    • (2008) J Cardiothorac Vasc Anesth , vol.22 , pp. 468-473
    • Maus, T.M.1    Lee, D.E.2
  • 7
    • 77950020487 scopus 로고    scopus 로고
    • Cardiac index validation using the pressure recording analytic method in unstable patients
    • Zangrillo A., Maj G., Monaco F., Scandroglio A.M., et al. Cardiac index validation using the pressure recording analytic method in unstable patients. J Cardiothorac Vasc Anesth 2010, 24:265-269.
    • (2010) J Cardiothorac Vasc Anesth , vol.24 , pp. 265-269
    • Zangrillo, A.1    Maj, G.2    Monaco, F.3    Scandroglio, A.M.4
  • 8
    • 0036342701 scopus 로고    scopus 로고
    • Assessment of cardiac output from systemic arterial pressure in humans
    • Romano S.M., Pistolesi M. Assessment of cardiac output from systemic arterial pressure in humans. Crit Care Med 2002, 30:1834-1841.
    • (2002) Crit Care Med , vol.30 , pp. 1834-1841
    • Romano, S.M.1    Pistolesi, M.2
  • 9
    • 70349653665 scopus 로고    scopus 로고
    • Response of serum proteome in patients undergoing infrarenal aortic aneurysm repair
    • Modesti P.A., Gamberi T., Bazzini C., et al. Response of serum proteome in patients undergoing infrarenal aortic aneurysm repair. Anesthesiology 2009, 111:844-854.
    • (2009) Anesthesiology , vol.111 , pp. 844-854
    • Modesti, P.A.1    Gamberi, T.2    Bazzini, C.3
  • 10
    • 79960700521 scopus 로고    scopus 로고
    • Cardiac cycle efficiency: a new index for cardiac work estimation tested during aortic valve plasty
    • Romagnoli S., Romano S.M., Lazzeri C., et al. Cardiac cycle efficiency: a new index for cardiac work estimation tested during aortic valve plasty. Crit Care 2010, 14(suppl.1):S45.
    • (2010) Crit Care , vol.14 , Issue.SUPPL. 1
    • Romagnoli, S.1    Romano, S.M.2    Lazzeri, C.3
  • 11
    • 66849093892 scopus 로고    scopus 로고
    • Management of blood pressure for acute and recurrent stroke
    • Aiyagari V., Gorelick P.B. Management of blood pressure for acute and recurrent stroke. Stroke 2009, 40:2251-2256.
    • (2009) Stroke , vol.40 , pp. 2251-2256
    • Aiyagari, V.1    Gorelick, P.B.2
  • 12
    • 69149101226 scopus 로고    scopus 로고
    • The changing face of hypertension treatment: treatment strategies from the 2007 ESH/ESC hypertension guidelines
    • Williams B. The changing face of hypertension treatment: treatment strategies from the 2007 ESH/ESC hypertension guidelines. J Hypertens 2009, 27(suppl 3):S19-S26.
    • (2009) J Hypertens , vol.27 , Issue.SUPPL. 3
    • Williams, B.1
  • 13
    • 34547616606 scopus 로고    scopus 로고
    • Quantitative left ventricular systolic function: from chamber to myocardium
    • Dittoe N., Stultz D., Schwartz B.P., et al. Quantitative left ventricular systolic function: from chamber to myocardium. Crit Care Med 2007, 35(suppl.):S330-S339.
    • (2007) Crit Care Med , vol.35 , Issue.SUPPL.
    • Dittoe, N.1    Stultz, D.2    Schwartz, B.P.3
  • 14
    • 33947305792 scopus 로고    scopus 로고
    • Radial pressure waveform dP/dt max is a poor indicator of left ventricular systolic function
    • Sharman J.E., Qasem A.M., Gill D.S., et al. Radial pressure waveform dP/dt max is a poor indicator of left ventricular systolic function. Eur J Clin Invest 2007, 37:276-281.
    • (2007) Eur J Clin Invest , vol.37 , pp. 276-281
    • Sharman, J.E.1    Qasem, A.M.2    Gill, D.S.3
  • 15
    • 0020123305 scopus 로고
    • Vascular impedance in studies of arterial and cardiac function
    • O'Rourke M.F. Vascular impedance in studies of arterial and cardiac function. Physiol Rev 1982, 2:570-623.
    • (1982) Physiol Rev , vol.2 , pp. 570-623
    • O'Rourke, M.F.1
  • 16
    • 33846670534 scopus 로고    scopus 로고
    • Ageing of the conduit arteries
    • Greenwald S.E. Ageing of the conduit arteries. J Pathol 2007, 211:157-172.
    • (2007) J Pathol , vol.211 , pp. 157-172
    • Greenwald, S.E.1
  • 17
    • 34247551188 scopus 로고    scopus 로고
    • Comparison of uncalibrated arterial waveform analysis in cardiac surgery patients with thermodilution cardiac output measurements
    • Sander M., Spies C.D., Grubitzsch H., et al. Comparison of uncalibrated arterial waveform analysis in cardiac surgery patients with thermodilution cardiac output measurements. Crit Care 2006, 10:R164.
    • (2006) Crit Care , vol.10
    • Sander, M.1    Spies, C.D.2    Grubitzsch, H.3
  • 18
    • 33847753396 scopus 로고    scopus 로고
    • Semi-invasive monitoring of cardiac output by a new device using arterial pressure waveform analysis: a comparison with intermittent pulmonary artery thermodilution in patients undergoing cardiac surgery
    • Mayer J., Boldt J., Schollhorn T., Rohm K.R., et al. Semi-invasive monitoring of cardiac output by a new device using arterial pressure waveform analysis: a comparison with intermittent pulmonary artery thermodilution in patients undergoing cardiac surgery. Br J Anaesth 2007, 98:176-182.
    • (2007) Br J Anaesth , vol.98 , pp. 176-182
    • Mayer, J.1    Boldt, J.2    Schollhorn, T.3    Rohm, K.R.4
  • 19
    • 62849098504 scopus 로고    scopus 로고
    • Assessment of cardiac output changes using a modified FloTrac/Vigileo™ algorithm in cardiac surgery patients
    • Senn A., Button D., Zollinger A., et al. Assessment of cardiac output changes using a modified FloTrac/Vigileo™ algorithm in cardiac surgery patients. Crit Care 2009, 13:R32.
    • (2009) Crit Care , vol.13
    • Senn, A.1    Button, D.2    Zollinger, A.3
  • 20
    • 77953245170 scopus 로고    scopus 로고
    • Arterial pressure-based cardiac output in septic patients: different accuracy of pulse contour and uncalibrated pressure waveform devices
    • Monnet X., Anguel L., Naudin B., et al. Arterial pressure-based cardiac output in septic patients: different accuracy of pulse contour and uncalibrated pressure waveform devices. Crit Care 2010, 14:R109.
    • (2010) Crit Care , vol.14
    • Monnet, X.1    Anguel, L.2    Naudin, B.3
  • 21
    • 0024544132 scopus 로고
    • Understanding natural frequency and damping and how they relate to the measurement of blood pressure
    • Kleinman B. Understanding natural frequency and damping and how they relate to the measurement of blood pressure. J Clin Monit 1989, 5:137-147.
    • (1989) J Clin Monit , vol.5 , pp. 137-147
    • Kleinman, B.1
  • 22
    • 0023235249 scopus 로고
    • Accuracy and dynamic response of disposable pressure transducer-tubing system
    • Hunzinker P. Accuracy and dynamic response of disposable pressure transducer-tubing system. Can J Anaesth 1987, 34:409-414.
    • (1987) Can J Anaesth , vol.34 , pp. 409-414
    • Hunzinker, P.1
  • 23
    • 0023832228 scopus 로고
    • Measurement of arterial pressure using catheter-transducer systems
    • Allan M.W.B., Gray W.M., Asbury A.J. Measurement of arterial pressure using catheter-transducer systems. Br J Anaesth 1988, 60:413-418.
    • (1988) Br J Anaesth , vol.60 , pp. 413-418
    • Allan, M.W.B.1    Gray, W.M.2    Asbury, A.J.3
  • 24
    • 0021713051 scopus 로고
    • Use of a needle valve variable resistor to improve invasive blood pressure monitoring
    • Abrams J.H., Olson M.L., Marino J.A., et al. Use of a needle valve variable resistor to improve invasive blood pressure monitoring. Crit Care Med 1984, 12:978-982.
    • (1984) Crit Care Med , vol.12 , pp. 978-982
    • Abrams, J.H.1    Olson, M.L.2    Marino, J.A.3
  • 25
    • 0024593364 scopus 로고
    • Dynamic response of the R.O.S.E. damping device
    • Kleinman B., Powell S. Dynamic response of the R.O.S.E. damping device. J Clin Monit 1989, 5:111-115.
    • (1989) J Clin Monit , vol.5 , pp. 111-115
    • Kleinman, B.1    Powell, S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.