메뉴 건너뛰기




Volumn 271, Issue 9-10, 2011, Pages 2322-2327

Wear properties of micro arc oxidized and hydrothermally treated Ti6Al4V alloy in simulated body fluid

Author keywords

Bioceramics; Hydrothermal treatment; Hydroxyapatite; Micro arc; SBF; Wear

Indexed keywords

BONE BONDING; CALCIUM ACETATE; COATED SURFACE; FILM LAYERS; GLYCEROPHOSPHATE; HARD TISSUES; HYDROTHERMAL TREATMENTS; HYDROTHERMALLY TREATED; MAO COATING PROCESS; MICRO ARC; MICROARC OXIDATION; NAOH SOLUTIONS; PH VALUE; PHASE COMPONENT; PIN-ON-DISK WEAR TEST; SBF; SCANNING ELECTRON MICROSCOPES; SIMULATED BODY FLUIDS; TI-6AL-4V; TI-6AL-4V ALLOY; TIO; TITANIA; WEAR PROPERTIES;

EID: 79960693613     PISSN: 00431648     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.wear.2010.12.039     Document Type: Article
Times cited : (57)

References (41)
  • 1
    • 0034010169 scopus 로고    scopus 로고
    • Deposition of layered bioceramic hydroxyapatite/TiO2 coatings on titanium alloys using a hybrid technique of micro-arc oxidation and electrophoresis
    • Nie X., Leyland A., Matthews A. Deposition of layered bioceramic hydroxyapatite/TiO2 coatings on titanium alloys using a hybrid technique of micro-arc oxidation and electrophoresis. Surf. Coat. Technol. 2000, 125:407-414.
    • (2000) Surf. Coat. Technol. , vol.125 , pp. 407-414
    • Nie, X.1    Leyland, A.2    Matthews, A.3
  • 2
    • 0033964001 scopus 로고    scopus 로고
    • Ion-beam-assisted deposition (IBAD) of hydroxyapatite coating layer on Ti-based metal substrate
    • Choi J.M., Kim H.E., Lee I.S. Ion-beam-assisted deposition (IBAD) of hydroxyapatite coating layer on Ti-based metal substrate. Biomaterials 2000, 21:469-473.
    • (2000) Biomaterials , vol.21 , pp. 469-473
    • Choi, J.M.1    Kim, H.E.2    Lee, I.S.3
  • 3
    • 13444283449 scopus 로고    scopus 로고
    • An investigation of the effects of hydroxyapatite coatings on the fixation strength of cortical screws
    • Yildirim O.S., Aksakal B., Celik H., Vangolu Y., Okur A. An investigation of the effects of hydroxyapatite coatings on the fixation strength of cortical screws. Med. Eng. Phys. 2005, 27:221-228.
    • (2005) Med. Eng. Phys. , vol.27 , pp. 221-228
    • Yildirim, O.S.1    Aksakal, B.2    Celik, H.3    Vangolu, Y.4    Okur, A.5
  • 6
    • 0031453696 scopus 로고    scopus 로고
    • Hydroxyapatite coatings: a comparative study between plasma-spray and pulsed laser deposition techniques
    • GarciaSanz F.J., Mayor M.B., Arias J.L., Pou J., Leon B., PerezAmor M. Hydroxyapatite coatings: a comparative study between plasma-spray and pulsed laser deposition techniques. J. Mater. Sci.:Mater. M 1997, 8:861-865.
    • (1997) J. Mater. Sci.:Mater. M , vol.8 , pp. 861-865
    • GarciaSanz, F.J.1    Mayor, M.B.2    Arias, J.L.3    Pou, J.4    Leon, B.5    PerezAmor, M.6
  • 7
    • 0242606916 scopus 로고    scopus 로고
    • Preparation of bioactive titanium metal via anodic oxidation treatment
    • Yang B.C., Uchida M., Kim H.M., Zhang X.D., Kokubo T. Preparation of bioactive titanium metal via anodic oxidation treatment. Biomaterials 2004, 25:1003-1010.
    • (2004) Biomaterials , vol.25 , pp. 1003-1010
    • Yang, B.C.1    Uchida, M.2    Kim, H.M.3    Zhang, X.D.4    Kokubo, T.5
  • 8
    • 0036134403 scopus 로고    scopus 로고
    • Functionally graded Ti/HAP coatings on Ti-6Al-4V obtained by chemical solution deposition
    • Lim Y.M., Park Y.J., Yun Y.H., Hwang K.S. Functionally graded Ti/HAP coatings on Ti-6Al-4V obtained by chemical solution deposition. Ceram. Int. 2002, 28:37-41.
    • (2002) Ceram. Int. , vol.28 , pp. 37-41
    • Lim, Y.M.1    Park, Y.J.2    Yun, Y.H.3    Hwang, K.S.4
  • 9
    • 33646061966 scopus 로고    scopus 로고
    • Hydroxyapatite formation on oxide films containing Ca and P by hydrothermal treatment
    • Liu F., Wang F.P., Shimizu T., Igarashi K., Zhao L.C. Hydroxyapatite formation on oxide films containing Ca and P by hydrothermal treatment. Ceram. Int. 2006, 32:527-531.
    • (2006) Ceram. Int. , vol.32 , pp. 527-531
    • Liu, F.1    Wang, F.P.2    Shimizu, T.3    Igarashi, K.4    Zhao, L.C.5
  • 11
    • 0034801327 scopus 로고    scopus 로고
    • Material fundamentals and clinical performance of plasma-sprayed hydroxyapatite coatings: A review
    • Sun L.M., Berndt C.C., Gross K.A., Kucuk A. Material fundamentals and clinical performance of plasma-sprayed hydroxyapatite coatings: A review. J. Biomed. Mater. Res. 2001, 58:570-592.
    • (2001) J. Biomed. Mater. Res. , vol.58 , pp. 570-592
    • Sun, L.M.1    Berndt, C.C.2    Gross, K.A.3    Kucuk, A.4
  • 13
    • 0034512937 scopus 로고    scopus 로고
    • Characterization of plasma-sprayed hydroxyapatite/TiO2 composite coatings
    • Zheng X.B., Ding C.X. Characterization of plasma-sprayed hydroxyapatite/TiO2 composite coatings. J. Therm. Spray Technol. 2000, 9:520-525.
    • (2000) J. Therm. Spray Technol. , vol.9 , pp. 520-525
    • Zheng, X.B.1    Ding, C.X.2
  • 14
    • 34047131874 scopus 로고    scopus 로고
    • Wear studies of hydroxyapatite composite coating reinforced by carbon nanotubes
    • Chen Y., Zhang T.H., Gan C.H., Yu G. Wear studies of hydroxyapatite composite coating reinforced by carbon nanotubes. Carbon 2007, 45:998-1004.
    • (2007) Carbon , vol.45 , pp. 998-1004
    • Chen, Y.1    Zhang, T.H.2    Gan, C.H.3    Yu, G.4
  • 15
    • 0026455928 scopus 로고
    • Calcium phosphate coatings for dental implants. Current status and future potential
    • Kay J.F. Calcium phosphate coatings for dental implants. Current status and future potential. Dent. Clin. North. Am. 1992, 36:1-18.
    • (1992) Dent. Clin. North. Am. , vol.36 , pp. 1-18
    • Kay, J.F.1
  • 16
    • 0033991643 scopus 로고    scopus 로고
    • XPS, EDX and FTIR analysis of pulsed laser deposited calcium phosphate bioceramic coatings: the effects of various process parameters
    • Zeng H.T., Lacefield W.R. XPS, EDX and FTIR analysis of pulsed laser deposited calcium phosphate bioceramic coatings: the effects of various process parameters. Biomaterials 2000, 21:23-30.
    • (2000) Biomaterials , vol.21 , pp. 23-30
    • Zeng, H.T.1    Lacefield, W.R.2
  • 18
    • 0029361094 scopus 로고
    • Characterization of thin hydroxyapatite layers formed on anodic titanium-oxide films containing Ca and P by hydrothermal treatment
    • Ishizawa H, Ogino M. Characterization of thin hydroxyapatite layers formed on anodic titanium-oxide films containing Ca and P by hydrothermal treatment. J. Biomed. Mater. Res. 1995, 29:1071-1079.
    • (1995) J. Biomed. Mater. Res. , vol.29 , pp. 1071-1079
    • Ishizawa, H.1    Ogino, M.2
  • 19
    • 0030382888 scopus 로고    scopus 로고
    • Thin hydroxyapatite layers formed on porous titanium using electrochemical and hydrothermal reaction
    • Ishizawa H., Ogino M. Thin hydroxyapatite layers formed on porous titanium using electrochemical and hydrothermal reaction. J. Mater. Sci. 1996, 31:6279-6284.
    • (1996) J. Mater. Sci. , vol.31 , pp. 6279-6284
    • Ishizawa, H.1    Ogino, M.2
  • 20
    • 0033285937 scopus 로고    scopus 로고
    • Hydrothermal precipitation of hydroxyapatite on anodic titanium oxide films containing Ca and P
    • Ishizawa H., Ogino M. Hydrothermal precipitation of hydroxyapatite on anodic titanium oxide films containing Ca and P. J. Mater. Sci. 1999, 34:5893-5898.
    • (1999) J. Mater. Sci. , vol.34 , pp. 5893-5898
    • Ishizawa, H.1    Ogino, M.2
  • 21
    • 27644581256 scopus 로고    scopus 로고
    • Formation characterization of hydroxyapatite on titanium by microarc oxidation and hydrothermal treatment
    • Liu F., Song Y., Wang F.P., Shimizu T., Igarashi K., Zhao L.C. Formation characterization of hydroxyapatite on titanium by microarc oxidation and hydrothermal treatment. J. Biosci. Bioeng. 2005, 100:100-104.
    • (2005) J. Biosci. Bioeng. , vol.100 , pp. 100-104
    • Liu, F.1    Song, Y.2    Wang, F.P.3    Shimizu, T.4    Igarashi, K.5    Zhao, L.C.6
  • 22
    • 18444413244 scopus 로고    scopus 로고
    • Corrosion resistance of the surface layers formed on titanium by plasma electrolytic oxidation and hydrothermal treatment
    • Baszkiewicz J., Krupa D., Mizera J., Sobczak J.W., Bilinski A. Corrosion resistance of the surface layers formed on titanium by plasma electrolytic oxidation and hydrothermal treatment. Vacuum 2005, 78:143-147.
    • (2005) Vacuum , vol.78 , pp. 143-147
    • Baszkiewicz, J.1    Krupa, D.2    Mizera, J.3    Sobczak, J.W.4    Bilinski, A.5
  • 23
    • 0037461450 scopus 로고    scopus 로고
    • Structure and in vitro bioactivity of titania-based films by micro-arc oxidation
    • Han Y., Hong S.H., Xu K.W. Structure and in vitro bioactivity of titania-based films by micro-arc oxidation. Surf. Coat. Technol. 2003, 168:249-258.
    • (2003) Surf. Coat. Technol. , vol.168 , pp. 249-258
    • Han, Y.1    Hong, S.H.2    Xu, K.W.3
  • 24
    • 0036827796 scopus 로고    scopus 로고
    • Synthesis of nanocrystalline titania films by micro-arc oxidation
    • Han Y., Hong S.H., Xu K.W. Synthesis of nanocrystalline titania films by micro-arc oxidation. Mater. Lett. 2002, 56:744-747.
    • (2002) Mater. Lett. , vol.56 , pp. 744-747
    • Han, Y.1    Hong, S.H.2    Xu, K.W.3
  • 25
    • 67349123123 scopus 로고    scopus 로고
    • Formation of hydroxyapatite within porous TiO2 layer by micro-arc oxidation coupled with electrophoretic deposition
    • Kim D.Y., Kim M., Kim H.E., Koh Y.H., Kim H.W., Jang J.H. Formation of hydroxyapatite within porous TiO2 layer by micro-arc oxidation coupled with electrophoretic deposition. Acta Biomater. 2009, 5:2196-2205.
    • (2009) Acta Biomater. , vol.5 , pp. 2196-2205
    • Kim, D.Y.1    Kim, M.2    Kim, H.E.3    Koh, Y.H.4    Kim, H.W.5    Jang, J.H.6
  • 26
    • 78649332532 scopus 로고    scopus 로고
    • Carbon nanotube toughened hydroxyapatite by spark plasma sintering: microstructural evolution and multiscale tribological properties
    • Lahiri D., Singh V., Keshri A.K., Seal S., Agarwal A. Carbon nanotube toughened hydroxyapatite by spark plasma sintering: microstructural evolution and multiscale tribological properties. Carbon 2010, 48:3103-3120.
    • (2010) Carbon , vol.48 , pp. 3103-3120
    • Lahiri, D.1    Singh, V.2    Keshri, A.K.3    Seal, S.4    Agarwal, A.5
  • 27
    • 68149181057 scopus 로고    scopus 로고
    • Effect of carbon nanotube and aluminum oxide addition on plasma-sprayed hydroxyapatite coating's mechanical properties and biocompatibility
    • Tercero J.E., Namin S., Lahiri D., Balani K., Tsoukias N., Agarwal A. Effect of carbon nanotube and aluminum oxide addition on plasma-sprayed hydroxyapatite coating's mechanical properties and biocompatibility. Mater. Sci. Eng. C: Mater. 2009, 29:2195-2202.
    • (2009) Mater. Sci. Eng. C: Mater. , vol.29 , pp. 2195-2202
    • Tercero, J.E.1    Namin, S.2    Lahiri, D.3    Balani, K.4    Tsoukias, N.5    Agarwal, A.6
  • 28
    • 46049085591 scopus 로고    scopus 로고
    • Structural characteristics and residual stresses in oxide films produced on Ti by pulsed unipolar plasma electrolytic oxidation
    • Khan R.H.U., Yerokhin A.L., Matthews A. Structural characteristics and residual stresses in oxide films produced on Ti by pulsed unipolar plasma electrolytic oxidation. Philos. Mag. 2008, 88:795-807.
    • (2008) Philos. Mag. , vol.88 , pp. 795-807
    • Khan, R.H.U.1    Yerokhin, A.L.2    Matthews, A.3
  • 29
    • 4644292598 scopus 로고    scopus 로고
    • Characterisation of a duplex TiO2/CaP coating on Ti6Al4V for hard tissue replacement
    • Ng B.D., Annergren I., Soutar A.M., Khor K.A., Jarfors A.E.W. Characterisation of a duplex TiO2/CaP coating on Ti6Al4V for hard tissue replacement. Biomaterials 2005, 26:1087-1095.
    • (2005) Biomaterials , vol.26 , pp. 1087-1095
    • Ng, B.D.1    Annergren, I.2    Soutar, A.M.3    Khor, K.A.4    Jarfors, A.E.W.5
  • 30
    • 52949091529 scopus 로고    scopus 로고
    • Effects of current frequency on the structural characteristics and corrosion property of ceramic coatings formed on magnesium alloy by PEO technology
    • Lv G.H., Chen H., Gu W.C., Li L., Niu E.W., Zhang X.H., Yang S.Z. Effects of current frequency on the structural characteristics and corrosion property of ceramic coatings formed on magnesium alloy by PEO technology. J. Mater. Process. Technol. 2008, 208:9-13.
    • (2008) J. Mater. Process. Technol. , vol.208 , pp. 9-13
    • Lv, G.H.1    Chen, H.2    Gu, W.C.3    Li, L.4    Niu, E.W.5    Zhang, X.H.6    Yang, S.Z.7
  • 31
    • 0022410875 scopus 로고
    • Comparative-study of porous hydroxyapatite and tricalcium phosphate as bone substitute
    • Shimazaki K., Mooney V. Comparative-study of porous hydroxyapatite and tricalcium phosphate as bone substitute. J. Orthopaed. Res. 1985, 3:301-310.
    • (1985) J. Orthopaed. Res. , vol.3 , pp. 301-310
    • Shimazaki, K.1    Mooney, V.2
  • 32
    • 0032730397 scopus 로고    scopus 로고
    • Quantification of bone ingrowth within bone-derived porous hydroxyapatite implants of varying density
    • Hing K.A., Best S.M., Tanner K.E., Bonfield W., Revell P.A. Quantification of bone ingrowth within bone-derived porous hydroxyapatite implants of varying density. J. Mater. Sci.:Mater. M 1999, 10:663-670.
    • (1999) J. Mater. Sci.:Mater. M , vol.10 , pp. 663-670
    • Hing, K.A.1    Best, S.M.2    Tanner, K.E.3    Bonfield, W.4    Revell, P.A.5
  • 33
    • 0032766416 scopus 로고    scopus 로고
    • Fretting wear behavior of thermal sprayed hydroxyapatite coating lubricated with bovine albumin
    • Fu Y.Q., Batchelor A.W., Khor K.A. Fretting wear behavior of thermal sprayed hydroxyapatite coating lubricated with bovine albumin. Wear 1999, 230:98-102.
    • (1999) Wear , vol.230 , pp. 98-102
    • Fu, Y.Q.1    Batchelor, A.W.2    Khor, K.A.3
  • 34
    • 0026360706 scopus 로고
    • Tribological properties of titanium-alloys
    • Budinski K.G. Tribological properties of titanium-alloys. Wear 1991, 151:203-217.
    • (1991) Wear , vol.151 , pp. 203-217
    • Budinski, K.G.1
  • 35
    • 0032170254 scopus 로고    scopus 로고
    • Titanium alloys in total joint replacement-a materials science perspective
    • Long M., Rack H.J. Titanium alloys in total joint replacement-a materials science perspective. Biomaterials 1998, 19:1621-1639.
    • (1998) Biomaterials , vol.19 , pp. 1621-1639
    • Long, M.1    Rack, H.J.2
  • 36
    • 0025449568 scopus 로고
    • X-ray-diffraction studies on plasma-sprayed calcium phosphate-coated implants
    • Koch B., Wolke J.G.C., Degroot K. X-ray-diffraction studies on plasma-sprayed calcium phosphate-coated implants. J. Biomed. Mater. Res. 1990, 24:655-667.
    • (1990) J. Biomed. Mater. Res. , vol.24 , pp. 655-667
    • Koch, B.1    Wolke, J.G.C.2    Degroot, K.3
  • 37
    • 0002199480 scopus 로고
    • Plasma spraying induced changes of calcium-phosphate ceramic characteristics and the effect on invitro stability
    • Radin S.R., Ducheyne P. Plasma spraying induced changes of calcium-phosphate ceramic characteristics and the effect on invitro stability. J. Mater. Sci.: Mater. M 1992, 3:33-42.
    • (1992) J. Mater. Sci.: Mater. M , vol.3 , pp. 33-42
    • Radin, S.R.1    Ducheyne, P.2
  • 38
    • 0026819119 scopus 로고
    • Post-plasma-spraying heat-treatment of the Ha coating/Ti-6Al-4V implant system
    • Filiaggi M.J., Pilliar R.M., Coombs N.A. Post-plasma-spraying heat-treatment of the Ha coating/Ti-6Al-4V implant system. J. Biomed. Mater. Res. 1993, 27:191-198.
    • (1993) J. Biomed. Mater. Res. , vol.27 , pp. 191-198
    • Filiaggi, M.J.1    Pilliar, R.M.2    Coombs, N.A.3
  • 39
    • 0027523985 scopus 로고
    • Effect of heat-treatment on the microstructure of plasma-sprayed hydroxyapatite coating
    • Ji H.X., Marquis P.M. Effect of heat-treatment on the microstructure of plasma-sprayed hydroxyapatite coating. Biomaterials 1993, 14:64-68.
    • (1993) Biomaterials , vol.14 , pp. 64-68
    • Ji, H.X.1    Marquis, P.M.2
  • 40
    • 68649088505 scopus 로고    scopus 로고
    • Influence of hydrothermal temperature on hydroxyapatite coating transformed from monetite on HT-C/C composites by induction heating method
    • Xiong X.B., Zeng X.R., Zou C.L., Li P., Fan Y.B. Influence of hydrothermal temperature on hydroxyapatite coating transformed from monetite on HT-C/C composites by induction heating method. Surf. Coat. Technol. 2009, 204:115-119.
    • (2009) Surf. Coat. Technol. , vol.204 , pp. 115-119
    • Xiong, X.B.1    Zeng, X.R.2    Zou, C.L.3    Li, P.4    Fan, Y.B.5
  • 41
    • 26944434308 scopus 로고    scopus 로고
    • Characterization of hydroxyapatite films obtained by pulsed-laser deposition on Ti and Ti-6AL-4V substrates
    • Blind O., Klein L.H., Dailey B., Jordan L. Characterization of hydroxyapatite films obtained by pulsed-laser deposition on Ti and Ti-6AL-4V substrates. Dent. Mater. 2005, 21:1017-1024.
    • (2005) Dent. Mater. , vol.21 , pp. 1017-1024
    • Blind, O.1    Klein, L.H.2    Dailey, B.3    Jordan, L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.