-
2
-
-
51449092401
-
3D high temporal and spatial resolution contrast-enhanced MR angiography of the whole brain
-
Haider CR, Hu HH, Campeau NG, Huston J III, Riederer SJ,. 3D high temporal and spatial resolution contrast-enhanced MR angiography of the whole brain. Magn Reson Med 2008; 60: 749-760.
-
(2008)
Magn Reson Med
, vol.60
, pp. 749-760
-
-
Haider, C.R.1
Hu, H.H.2
Campeau, N.G.3
Huston III, J.4
Riederer, S.J.5
-
3
-
-
79960573233
-
-
MR Angio Club. East Lansing, MI.
-
Haider CR, Glockner JF, Vrtiska TJ, Macedo TA, Borisch EA, Riederer SJ,. A comparison of time-resolved 3D CE-MRA with peripheral run-off CTA in the calves. MR Angio Club. East Lansing, MI; 2009.
-
(2009)
A Comparison of Time-resolved 3D CE-MRA with Peripheral Run-off CTA in the Calves
-
-
Haider, C.R.1
Glockner, J.F.2
Vrtiska, T.J.3
Macedo, T.A.4
Borisch, E.A.5
Riederer, S.J.6
-
4
-
-
66249143725
-
Contrast-enhanced MR angiography using time resolved interleaved projection sampling with three-dimensional cartesian phase and slice encoding (TRIPPS)
-
Du J,. Contrast-enhanced MR angiography using time resolved interleaved projection sampling with three-dimensional cartesian phase and slice encoding (TRIPPS). Magn Reson Med 2009; 61: 918-924.
-
(2009)
Magn Reson Med
, vol.61
, pp. 918-924
-
-
Du, J.1
-
5
-
-
36849088522
-
Sparse MRI: The application of compressed sensing for rapid MR imaging
-
DOI 10.1002/mrm.21391
-
Lustig M, Donoho D, Pauly JM,. Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn Reson Med 2007; 58: 1182-1195. (Pubitemid 350234205)
-
(2007)
Magnetic Resonance in Medicine
, vol.58
, Issue.6
, pp. 1182-1195
-
-
Lustig, M.1
Donoho, D.2
Pauly, J.M.3
-
6
-
-
79960584342
-
Optimization of variable-density Cartesian sampling for time-resolved imaging
-
Hawai'i
-
Busse RF, Wang K, Holmes JH, Brittain JH, Korosec FR,. Optimization of variable-density Cartesian sampling for time-resolved imaging. In: Proceedings of the 17th Annual Meeting ISMRM. Hawai'i; 2009. p 4534.
-
(2009)
Proceedings of the 17th Annual Meeting ISMRM
, pp. 4534
-
-
Busse, R.F.1
Wang, K.2
Holmes, J.H.3
Brittain, J.H.4
Korosec, F.R.5
-
7
-
-
7044262262
-
Contrast-enhanced peripheral magnetic resonance angiography using time-resolved vastly undersampled isotropic projection reconstruction
-
DOI 10.1002/jmri.20189
-
Du J, Carroll TJ, Brodsky E, Lu A, Grist TM, Mistretta CA, Block WF,. Contrast-enhanced peripheral magnetic resonance angiography using time-resolved vastly undersampled isotropic projection reconstruction. J Magn Reson Imaging 2004; 20: 894-900. (Pubitemid 39426088)
-
(2004)
Journal of Magnetic Resonance Imaging
, vol.20
, Issue.5
, pp. 894-900
-
-
Du, J.1
Carroll, T.J.2
Brodsky, E.3
Lu, A.4
Grist, T.M.5
Mistretta, C.A.6
Block, W.F.7
-
8
-
-
49049108309
-
Simulation of relative temporal resolution of time-resolved MRA sequences
-
Keith L, Kecskemeti S, Velikina J, Mistretta C,. Simulation of relative temporal resolution of time-resolved MRA sequences. Magn Reson Med 2008; 60: 398-404.
-
(2008)
Magn Reson Med
, vol.60
, pp. 398-404
-
-
Keith, L.1
Kecskemeti, S.2
Velikina, J.3
Mistretta, C.4
-
9
-
-
79960599218
-
Time-resolved imaging with multiplicative algebraic reconstruction technique (MART): An application of HYPR principles for variable density Cartesian acquisitions
-
Hawai'i
-
Busse RF, Pineda AR, Wang K, Holmes JH, Brittain JH, Korosec FR,. Time-resolved imaging with multiplicative algebraic reconstruction technique (MART): an application of HYPR principles for variable density Cartesian acquisitions. In: Proceedings of the 17th Annual Meeting ISMRM, Hawai'i; 2009. p 2834.
-
(2009)
Proceedings of the 17th Annual Meeting ISMRM
, pp. 2834
-
-
Busse, R.F.1
Pineda, A.R.2
Wang, K.3
Holmes, J.H.4
Brittain, J.H.5
Korosec, F.R.6
-
10
-
-
0030982409
-
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
-
DOI 10.1002/mrm.1910380414
-
Sodickson DK, Manning WJ,. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn Reson Med 1997; 38: 591-603. (Pubitemid 27419224)
-
(1997)
Magnetic Resonance in Medicine
, vol.38
, Issue.4
, pp. 591-603
-
-
Sodickson, D.K.1
Manning, W.J.2
-
11
-
-
0032712873
-
SENSE: Sensitivity encoding for fast MRI
-
DOI 10.1002/(SICI)1522-2594(1999 11)42:5<952::AID-MRM16>3.0.CO;2-S
-
Pruessmann KP, Weiger M, Scheidegger MB, Boesiger P,. SENSE: sensitivity encoding for fast MRI. Magn Reson Med 1999; 42: 952-962. (Pubitemid 29521486)
-
(1999)
Magnetic Resonance in Medicine
, vol.42
, Issue.5
, pp. 952-962
-
-
Pruessmann, K.P.1
Weiger, M.2
Scheidegger, M.B.3
Boesiger, P.4
-
12
-
-
0034845169
-
A generalized approach to parallel magnetic resonance imaging
-
DOI 10.1118/1.1386778
-
Sodickson DK, McKenzie CA,. A generalized approach to parallel magnetic resonance imaging. Med Phys 2001; 28: 1629-1643. (Pubitemid 32783206)
-
(2001)
Medical Physics
, vol.28
, Issue.8
, pp. 1629-1643
-
-
Sodicksona, D.K.1
McKenzie, C.A.2
-
13
-
-
0032425458
-
AUTO-SMASH: A self-calibrating technique for SMASH imaging
-
DOI 10.1016/S1352-8661(98)00015-5, PII S1352866198000155
-
Jakob PM, Griswold MA, Edelman RR, Sodickson DK,. AUTO-SMASH: a self-calibrating technique for SMASH imaging. Simultaneous acquisition of spatial harmonics. Magma 1998; 7: 42-54. (Pubitemid 29014256)
-
(1998)
Magnetic Resonance Materials in Physics, Biology and Medicine
, vol.7
, Issue.1
, pp. 42-54
-
-
Jakob, P.M.1
Griswold, M.A.2
Edelman, R.R.3
Sodickson, D.K.4
-
14
-
-
0034997208
-
VD-AUTO-SMASH imaging
-
Heidemann RM, Griswold MA, Haase A, Jakob PM,. VD-AUTO-SMASH imaging. Magn Reson Med 2001; 45: 1066-1074.
-
(2001)
Magn Reson Med
, vol.45
, pp. 1066-1074
-
-
Heidemann, R.M.1
Griswold, M.A.2
Haase, A.3
Jakob, P.M.4
-
15
-
-
0036263907
-
Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA)
-
DOI 10.1002/mrm.10171
-
Griswold MA, Jakob PM, Heidemann RM, Nittka M, Jellus V, Wang J, Kiefer B, Haase A,. Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 2002; 47: 1202-1210. (Pubitemid 34587412)
-
(2002)
Magnetic Resonance in Medicine
, vol.47
, Issue.6
, pp. 1202-1210
-
-
Griswold, M.A.1
Jakob, P.M.2
Heidemann, R.M.3
Nittka, M.4
Jellus, V.5
Wang, J.6
Kiefer, B.7
Haase, A.8
-
16
-
-
0030227654
-
Application of reduced-encoding imaging with generalized-series reconstruction (RIGR) in dynamic MR imaging
-
Chandra S, Liang ZP, Webb A, Lee H, Morris HD, Lauterbur PC,. Application of reduced-encoding imaging with generalized-series reconstruction (RIGR) in dynamic MR imaging. J Magn Reson Imaging 1996; 6: 783-797. (Pubitemid 126702024)
-
(1996)
Journal of Magnetic Resonance Imaging
, vol.6
, Issue.5
, pp. 783-797
-
-
Chandra, S.1
Liang, Z.-P.2
Webb, A.3
Lee, H.4
Douglas Morris, H.5
Lauterbur, P.C.6
-
17
-
-
0242385483
-
K-t BLAST and k-t SENSE: Dynamic MRI With High Frame Rate Exploiting Spatiotemporal Correlations
-
DOI 10.1002/mrm.10611
-
Tsao J, Boesiger P, Pruessmann KP,. k-t BLAST and k-t SENSE: dynamic MRI with high frame rate exploiting spatiotemporal correlations. Magn Reson Med 2003; 50: 1031-1042. (Pubitemid 37356583)
-
(2003)
Magnetic Resonance in Medicine
, vol.50
, Issue.5
, pp. 1031-1042
-
-
Tsao, J.1
Boesiger, P.2
Pruessmann, K.P.3
-
18
-
-
31744440684
-
Robust uncertainty principles: Exact signal reconstruction from highly incomplete frequency information
-
DOI 10.1109/TIT.2005.862083
-
Candes EJ, Romberg J, Tao T,. Robust uncertainty principles: exact signal reconstruction from highly incomplete frequency information. IEEE Trans Inf Theory 2006; 52: 489-509. (Pubitemid 43174093)
-
(2006)
IEEE Transactions on Information Theory
, vol.52
, Issue.2
, pp. 489-509
-
-
Candes, E.J.1
Romberg, J.2
Tao, T.3
-
19
-
-
33645712892
-
Compressed sensing
-
Donoho DL,. Compressed sensing. IEEE Trans Inf Theory 2006; 52: 1289-1306.
-
(2006)
IEEE Trans Inf Theory
, vol.52
, pp. 1289-1306
-
-
Donoho, D.L.1
-
20
-
-
72249115141
-
L1 SPIR-iT: Autocalibrating parallel imaging compressed sensing
-
Hawai'i
-
Lustig M, Alley M, Vasanawala S, Donoho DL, Pauly JM,. L1 SPIR-iT: autocalibrating parallel imaging compressed sensing. In: Proceedings of the 17th Annual Meeting ISMRM, Hawai'i; 2009. p 379.
-
(2009)
Proceedings of the 17th Annual Meeting ISMRM
, pp. 379
-
-
Lustig, M.1
Alley, M.2
Vasanawala, S.3
Donoho, D.L.4
Pauly, J.M.5
-
21
-
-
30344488447
-
Highly constrained backprojection for time-resolved MRI
-
DOI 10.1002/mrm.20772
-
Mistretta CA, Wieben O, Velikina J, Block W, Perry J, Wu Y, Johnson K, Wu Y,. Highly constrained backprojection for time-resolved MRI. Magn Reson Med 2006; 55: 30-40. (Pubitemid 43062925)
-
(2006)
Magnetic Resonance in Medicine
, vol.55
, Issue.1
, pp. 30-40
-
-
Mistretta, C.A.1
Wieben, O.2
Velikina, J.3
Block, W.4
Perry, J.5
Wu, Y.6
Johnson, K.7
Wu, Y.8
-
22
-
-
40449123693
-
Improved waveform fidelity using local HYPR reconstruction (HYPR LR)
-
DOI 10.1002/mrm.21505
-
Johnson KM, Velikina J, Wu Y, Kecskemeti S, Wieben O, Mistretta CA,. Improved waveform fidelity using local HYPR reconstruction (HYPR LR). Magn Reson Med 2008; 59: 456-462. (Pubitemid 351348214)
-
(2008)
Magnetic Resonance in Medicine
, vol.59
, Issue.3
, pp. 456-462
-
-
Johnson, K.M.1
Velikina, J.2
Wu, Y.3
Kecskemeti, S.4
Wieben, O.5
Mistretta, C.A.6
-
23
-
-
34547941998
-
Time-resolved MR angiography with limited projections
-
DOI 10.1002/mrm.21312
-
Huang Y, Wright GA,. Time-resolved MR angiography with limited projections. Magn Reson Med 2007; 58: 316-325. (Pubitemid 47267649)
-
(2007)
Magnetic Resonance in Medicine
, vol.58
, Issue.2
, pp. 316-325
-
-
Huang, Y.1
Wright, G.A.2
-
24
-
-
37549035028
-
Iterative projection reconstruction of time-resolved images using highly-constrained back-projection (HYPR)
-
O'Halloran RL, Wen Z, Holmes JH, Fain SB,. Iterative projection reconstruction of time-resolved images using highly-constrained back-projection (HYPR). Magn Reson Med 2008; 59: 132-139.
-
(2008)
Magn Reson Med
, vol.59
, pp. 132-139
-
-
O'Halloran, R.L.1
Wen, Z.2
Holmes, J.H.3
Fain, S.B.4
-
25
-
-
67650081533
-
Ultrashort TE spectroscopic imaging (UTESI) using complex highly-constrained backprojection with local reconstruction (HYPR LR)
-
Wang K, Du J, O'Halloran R, Fain S, Kecskemeti S, Wieben O, Johnson KM, Mistretta C,. Ultrashort TE spectroscopic imaging (UTESI) using complex highly-constrained backprojection with local reconstruction (HYPR LR). Magn Reson Med 2009; 62: 127-134.
-
(2009)
Magn Reson Med
, vol.62
, pp. 127-134
-
-
Wang, K.1
Du, J.2
O'Halloran, R.3
Fain, S.4
Kecskemeti, S.5
Wieben, O.6
Johnson, K.M.7
Mistretta, C.8
-
26
-
-
79960595741
-
Comparison of HYPR Stack-Of-Stars and HYPR VIPR to TRICKS in Peripheral CE MRA
-
Toronto, Canada
-
Wu Y, Johnson K, Wieben O, Velikina J, Carrillo A, Kecskemeti S, Mistretta C, Korosec F,. Comparison of HYPR Stack-Of-Stars and HYPR VIPR to TRICKS in Peripheral CE MRA. In: Proceedings of the 16th Annual Meeting ISMRM, Toronto, Canada; 2008. p 108.
-
(2008)
Proceedings of the 16th Annual Meeting ISMRM
, pp. 108
-
-
Wu, Y.1
Johnson, K.2
Wieben, O.3
Velikina, J.4
Carrillo, A.5
Kecskemeti, S.6
Mistretta, C.7
Korosec, F.8
-
27
-
-
79960574837
-
Accelerated 3D Time-Resolved MR Angiography using Cartesian HYPR LR Reconstruction
-
Hawai'i
-
Wang K, Du J, Wu Y, Busse RF, Johnson K, Korosec FR,. Accelerated 3D Time-Resolved MR Angiography using Cartesian HYPR LR Reconstruction. In: Proceedings of the 17th Annual Meeting ISMRM, Hawai'i; 2009. p 3884.
-
(2009)
Proceedings of the 17th Annual Meeting ISMRM
, pp. 3884
-
-
Wang, K.1
Du, J.2
Wu, Y.3
Busse, R.F.4
Johnson, K.5
Korosec, F.R.6
-
28
-
-
38949156006
-
A method for autocalibrating 2-D accelerated volumetric parallel imaging with clinically practical reconstruction times
-
Berlin, Germany
-
Beatty PJ, Brau AC, Chang S, Joshi SM, Michelich CR, Bayram E, Nelson TE, Herfkens RJ, Brittain JH,. A method for autocalibrating 2-D accelerated volumetric parallel imaging with clinically practical reconstruction times. In: Proceedings of the 15th Annual Meeting ISMRM, Berlin, Germany; 2007. p 1749.
-
(2007)
Proceedings of the 15th Annual Meeting ISMRM
, pp. 1749
-
-
Beatty, P.J.1
Brau, A.C.2
Chang, S.3
Joshi, S.M.4
Michelich, C.R.5
Bayram, E.6
Nelson, T.E.7
Herfkens, R.J.8
Brittain, J.H.9
-
29
-
-
38949120094
-
Comparison of reconstruction accuracy and efficiency among autocalibrating data-driven parallel imaging methods
-
DOI 10.1002/mrm.21481
-
Brau AC, Beatty PJ, Skare S, Bammer R,. Comparison of reconstruction accuracy and efficiency among autocalibrating data-driven parallel imaging methods. Magn Reson Med 2008; 59: 382-395. (Pubitemid 351220102)
-
(2008)
Magnetic Resonance in Medicine
, vol.59
, Issue.2
, pp. 382-395
-
-
Brau, A.C.S.1
Beatty, P.J.2
Skare, S.3
Bammer, R.4
-
30
-
-
75749144669
-
PC HYPR flow: A technique for rapid imaging of contrast dynamics
-
Velikina JV, Johnson KM, Wu Y, Samsonov AA, Turski P, Mistretta CA,. PC HYPR flow: a technique for rapid imaging of contrast dynamics. J Magn Reson Imaging 2010; 31: 447-456.
-
(2010)
J Magn Reson Imaging
, vol.31
, pp. 447-456
-
-
Velikina, J.V.1
Johnson, K.M.2
Wu, Y.3
Samsonov, A.A.4
Turski, P.5
Mistretta, C.A.6
-
31
-
-
73149107247
-
Three-dimensional imaging of ventilation dynamics in asthmatics using multiecho projection acquisition with constrained reconstruction
-
Holmes JH, O'Halloran RL, Brodsky EK, Bley TA, Francois CJ, Velikina JV, Sorkness RL, Busse WW, Fain SB,. Three-dimensional imaging of ventilation dynamics in asthmatics using multiecho projection acquisition with constrained reconstruction. Magn Reson Med 2009; 62: 1543-1556.
-
(2009)
Magn Reson Med
, vol.62
, pp. 1543-1556
-
-
Holmes, J.H.1
O'Halloran, R.L.2
Brodsky, E.K.3
Bley, T.A.4
Francois, C.J.5
Velikina, J.V.6
Sorkness, R.L.7
Busse, W.W.8
Fain, S.B.9
-
32
-
-
79960578875
-
-
MR Angio Club, Seoul, Korea:Abstract 8.5.
-
Holmes JH, Wang K, Busse RF, Beatty PJ, Brittain JH, Francois CJ, Reeder SB, Keith L, Wu Y, Korosec FR,. 3D Time-resolved MRA of lower extremities using interleaved variable density sampling, parallel imaging and Cartesian HYPR reconstruction. MR Angio Club, Seoul, Korea 2010:Abstract 8.5.
-
(2010)
3D Time-resolved MRA of Lower Extremities Using Interleaved Variable Density Sampling, Parallel Imaging and Cartesian HYPR Reconstruction
-
-
Holmes, J.H.1
Wang, K.2
Busse, R.F.3
Beatty, P.J.4
Brittain, J.H.5
Francois, C.J.6
Reeder, S.B.7
Keith, L.8
Wu, Y.9
Korosec, F.R.10
-
33
-
-
0025226022
-
The NMR phased array
-
Roemer PB, Edelstein WA, Hayes CE, Souza SP, Mueller OM,. The NMR phased array. Magn Reson Med 1990; 16: 192-225.
-
(1990)
Magn Reson Med
, vol.16
, pp. 192-225
-
-
Roemer, P.B.1
Edelstein, W.A.2
Hayes, C.E.3
Souza, S.P.4
Mueller, O.M.5
-
35
-
-
79960596305
-
Is HYPR compatible with a Cartesian acquisition?
-
Berlin, Germany
-
Yutzy S, Griswold MA, Duerk JL,. Is HYPR compatible with a Cartesian acquisition? In: Proceedings of the 15th Annual Meeting ISMRM, Berlin, Germany; 2007. p 832.
-
(2007)
Proceedings of the 15th Annual Meeting ISMRM
, pp. 832
-
-
Yutzy, S.1
Griswold, M.A.2
Duerk, J.L.3
-
36
-
-
0033971791
-
Undersampled projection reconstruction applied to MR angiography
-
DOI 10.1002/(SICI)1522-2594(20000 1)43:1<91::AID-MRM11>3.0.CO;2-4
-
Peters DC, Korosec FR, Grist TM, Block WF, Holden JE, Vigen KK, Mistretta CA,. Undersampled projection reconstruction applied to MR angiography. Magn Reson Med 2000; 43: 91-101. (Pubitemid 30027116)
-
(2000)
Magnetic Resonance in Medicine
, vol.43
, Issue.1
, pp. 91-101
-
-
Peters, D.C.1
Korosec, F.R.2
Grist, T.M.3
Block, W.F.4
Holden, J.E.5
Vigen, K.K.6
Mistretta, C.A.7
-
37
-
-
0036319895
-
Time-resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory
-
DOI 10.1002/mrm.10212
-
Barger AV, Block WF, Toropov Y, Grist TM, Mistretta CA,. Time-resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory. Magn Reson Med 2002; 48: 297-305. (Pubitemid 34809418)
-
(2002)
Magnetic Resonance in Medicine
, vol.48
, Issue.2
, pp. 297-305
-
-
Barger, A.V.1
Block, W.F.2
Toropov, Y.3
Grist, T.M.4
Mistretta, C.A.5
-
38
-
-
0027053145
-
Fast spiral coronary artery imaging
-
DOI 10.1002/mrm.1910280204
-
Meyer CH, Hu BS, Nishimura DG, Macovski A,. Fast spiral coronary artery imaging. Magn Reson Med 1992; 28: 202-213. (Pubitemid 23027662)
-
(1992)
Magnetic Resonance in Medicine
, vol.28
, Issue.2
, pp. 202-213
-
-
Meyer, C.H.1
Hu, B.S.2
Nishimura, D.G.3
Macovski, A.4
-
39
-
-
36348942999
-
High-resolution time-resolved contrast-enhanced MR abdominal and pulmonary angiography using a spiral-TRICKS sequence
-
DOI 10.1002/mrm.21298
-
Du J, Bydder M,. High-resolution time-resolved contrast-enhanced MR abdominal and pulmonary angiography using a spiral-TRICKS sequence. Magn Reson Med 2007; 58: 631-635. (Pubitemid 350154976)
-
(2007)
Magnetic Resonance in Medicine
, vol.58
, Issue.3
, pp. 631-635
-
-
Du, J.1
Bydder, M.2
-
40
-
-
66149152703
-
Radial sliding-window magnetic resonance angiography (MRA) with highly-constrained projection reconstruction (HYPR)
-
Jeong HJ, Cashen TA, Hurley MC, Eddleman C, Getch C, Batjer HH, Carroll TJ,. Radial sliding-window magnetic resonance angiography (MRA) with highly-constrained projection reconstruction (HYPR). Magn Reson Med 2009; 61: 1103-1113.
-
(2009)
Magn Reson Med
, vol.61
, pp. 1103-1113
-
-
Jeong, H.J.1
Cashen, T.A.2
Hurley, M.C.3
Eddleman, C.4
Getch, C.5
Batjer, H.H.6
Carroll, T.J.7
-
41
-
-
79960614287
-
-
MR Angio Club, Seoul, Korea: Abstract 2.3.
-
Wang K, Korosec FR, Artz NS, Schiebler ML, Francois CJ, Reeder SB, Grist TM, Busse RF, Holmes JH, Fain S, Nagle SK,. Dynamic pulmonary perfusion imaging using interleaved variable density sampling, parallel imaging and Cartesian HYPR reconstruction. MR Angio Club, Seoul, Korea 2010: Abstract 2.3.
-
(2010)
Dynamic Pulmonary Perfusion Imaging Using Interleaved Variable Density Sampling, Parallel Imaging and Cartesian HYPR Reconstruction
-
-
Wang, K.1
Korosec, F.R.2
Artz, N.S.3
Schiebler, M.L.4
Francois, C.J.5
Reeder, S.B.6
Grist, T.M.7
Busse, R.F.8
Holmes, J.H.9
Fain, S.10
Nagle, S.K.11
-
42
-
-
34249017511
-
K-t SPARSE: High frame rate dynamic MRI exploiting spatio-temporal sparsity
-
Seattle
-
Lustig M, Santos J, Donoho D, Pauly J,. k-t SPARSE: high frame rate dynamic MRI exploiting spatio-temporal sparsity. In: Proceedings of the 14th Annual Meeting ISMRM, Seattle; 2006. p 2420.
-
(2006)
Proceedings of the 14th Annual Meeting ISMRM
, pp. 2420
-
-
Lustig, M.1
Santos, J.2
Donoho, D.3
Pauly, J.4
-
43
-
-
60349105482
-
K-t FOCUSS: A general compressed sensing framework for high resolution dynamic MRI
-
Jung H, Sung K, Nayak KS, Kim EY, Ye JC,. k-t FOCUSS: a general compressed sensing framework for high resolution dynamic MRI. Magn Reson Med 2009; 61: 103-116.
-
(2009)
Magn Reson Med
, vol.61
, pp. 103-116
-
-
Jung, H.1
Sung, K.2
Nayak, K.S.3
Kim, E.Y.4
Ye, J.C.5
-
44
-
-
37549061019
-
More optimal HYPR reconstructions using a combination of HYPR and conjugate-gradient minimization
-
Basel, Switzerland
-
Griswold M, Barkauskas K, Blaimer M, Moriguchi H, Sunshine J, Duerk J,. More optimal HYPR reconstructions using a combination of HYPR and conjugate-gradient minimization. In: Proceedings of MRA club, Basel, Switzerland; 2006. p 29.
-
(2006)
Proceedings of MRA Club
, pp. 29
-
-
Griswold, M.1
Barkauskas, K.2
Blaimer, M.3
Moriguchi, H.4
Sunshine, J.5
Duerk, J.6
-
45
-
-
0014905513
-
Algebraic reconstruction techniques (ART) for three-dimensional electron microscopy and x-ray photography
-
Gordon R, Bender R, Herman GT,. Algebraic reconstruction techniques (ART) for three-dimensional electron microscopy and x-ray photography. J Theor Biol 1970; 29: 471-481.
-
(1970)
J Theor Biol
, vol.29
, pp. 471-481
-
-
Gordon, R.1
Bender, R.2
Herman, G.T.3
|