-
1
-
-
32944457397
-
Bile duct injury in the era of laparoscopic cholecystectomy
-
DOI 10.1002/bjs.5266
-
Connor S, Garden OJ,. (2006) Bile duct injury in the era of laparoscopic cholecystectomy. Br J Surg 93: 158-168. (Pubitemid 43259599)
-
(2006)
British Journal of Surgery
, vol.93
, Issue.2
, pp. 158-168
-
-
Connor, S.1
Garden, O.J.2
-
2
-
-
0031453570
-
The dramatic reality of biliary tract injury during laparoscopic cholecystectomy: An anonymous multicenter Belgian survey of 65 patients
-
Gigot J, Etienne J, Aerts R, Wibin E, Dallemagne B, Deweer F, et al,. (1997) The dramatic reality of biliary tract injury during laparoscopic cholecystectomy. An anonymous multicentre Belgian survey of 65 patients. Surg Endosc 11: 1171-1178. (Pubitemid 127524453)
-
(1997)
Surgical Endoscopy
, vol.11
, Issue.12
, pp. 1171-1178
-
-
Gigot, J.-F.1
Etienne, J.2
Aerts, R.3
Wibin, E.4
Dallemagne, B.5
Deweer, F.6
Fortunati, D.7
Legrand, M.8
Vereecken, L.9
Doumont, J.-M.10
Van Reepinghen, P.11
Beguin, C.12
-
3
-
-
0036943779
-
Surgical management of bile duct injuries following laparoscopic cholecystectomy: Analysis and follow-up of 28 cases
-
DOI 10.1007/s00423-002-0330-x
-
Seeliger H, Furst A, Zulke C, Jauch KW,. (2002) Surgical management of bile duct injuries following laparoscopic cholecystectomy: analysis and follow-up of 28 cases. Langenbecks Arch Surg 389: 286-293. (Pubitemid 36061855)
-
(2002)
Langenbeck's Archives of Surgery
, vol.387
, Issue.7-8
, pp. 286-293
-
-
Seeliger, H.1
Furst, A.2
Zulke, C.3
Jauch, K.-W.4
-
4
-
-
1842686898
-
EXPERIMENTAL STUDY ON REPAIR OF BILE DUCT DEFECTS WITH EXPANDED POLYTETRAFLUOROETHYLENE
-
Ren W,. (2001) Experimental study on repair of bile duct defects with expanded polytetrafluoroethylene. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi 15: 305-307. (Pubitemid 33340583)
-
(2001)
Chinese Journal of Reparative and Reconstructive Surgery
, vol.15
, Issue.5
, pp. 305-307
-
-
Ren, W.1
Shi, D.2
-
5
-
-
31544448889
-
A new technique for reconstruction of the common bile duct by an autologous vein graft and a biodegradable endoluminal stent
-
DOI 10.1080/08941930500444560, PII X213674707062
-
Heistermann H, Palmes D, Stratmann U, Hohlbach G, Hierlemann H, Langer M, et al,. (2006) A new technique for reconstruction of the common bile duct by an autologous vein graft and a biodegradable endoluminal stent. J Invest Surg 19: 57-60. (Pubitemid 43158207)
-
(2006)
Journal of Investigative Surgery
, vol.19
, Issue.1
, pp. 57-60
-
-
Heistermann, H.-P.1
Palmes, D.2
Stratmann, U.3
Hohlbach, G.4
Hierlemann, H.5
Langer, M.6
Spiegel, H.-U.7
-
6
-
-
0036747171
-
Small intestinal submucosa as a bioscaffold for biliary tract regeneration
-
DOI 10.1016/S0039-6060(02)00114-9
-
Rosen M, Ponsky J, Petras R, Fanning A, Brody F, Duperier F,. (2002) Small intestinal submucosa as a bioscaffold for biliary tract regeneration. Surgery 132: 480-486. (Pubitemid 35155483)
-
(2002)
Surgery
, vol.132
, Issue.3
, pp. 480-486
-
-
Rosen, M.1
Ponsky, J.2
Petras, R.3
Fanning, A.4
Brody, F.5
Duperier, F.6
-
7
-
-
77949484881
-
A novel treatment for bile duct injury with a tissue-engineered bioabsorbable polymer patch
-
Aikawa M, Miyazawa M, Okamoto K, Toshimitsu Y, Torii T, Okada K, et al,. (2010) A novel treatment for bile duct injury with a tissue-engineered bioabsorbable polymer patch. Surgery 147: 575-580.
-
(2010)
Surgery
, vol.147
, pp. 575-580
-
-
Aikawa, M.1
Miyazawa, M.2
Okamoto, K.3
Toshimitsu, Y.4
Torii, T.5
Okada, K.6
-
8
-
-
20544458765
-
A tissue-engineered artificial bile duct grown to resemble the native bile duct
-
DOI 10.1111/j.1600-6143.2005.00845.x
-
Miyazawa M, Torii T, Toshimitsu Y, Okada K, Koyama I, Ikada Y,. (2005) A tissue-engineered artificial bile duct grown to resemble the native bile duct. Am J Transplant 5: 1541-1547. (Pubitemid 40839450)
-
(2005)
American Journal of Transplantation
, vol.5
, Issue.6
, pp. 1541-1547
-
-
Miyazawa, M.1
Torii, T.2
Toshimitsu, Y.3
Okada, K.4
Koyama, I.5
Ikada, Y.6
-
9
-
-
20944442972
-
Surgical management of bile duct injuries sustained during laparoscopic cholecystectomy: Perioperative results in 200 patients
-
discussion 793-795.
-
Sicklick JK, Camp MS, Lillemoe KD, Melton GB, Yeo CJ, Campbell KA, et al,. (2005) Surgical management of bile duct injuries sustained during laparoscopic cholecystectomy: perioperative results in 200 patients. Ann Surg 241: 786-792; discussion 793-795.
-
(2005)
Ann Surg
, vol.241
, pp. 786-792
-
-
Sicklick, J.K.1
Camp, M.S.2
Lillemoe, K.D.3
Melton, G.B.4
Yeo, C.J.5
Campbell, K.A.6
-
10
-
-
0025181744
-
Coelioscopic cholecystectomy. Preliminary report of 36 cases
-
Dubois F, Icard P, Berthelot G, Levard H,. (1990) Coeliscopic cholecystectomy. Preliminary report of 36 cases. Ann Surg 211: 60-62. (Pubitemid 20027884)
-
(1990)
Annals of Surgery
, vol.211
, Issue.1
, pp. 60-62
-
-
Dubois, F.1
Icard, P.2
Berthelot, G.3
Levard, H.4
-
11
-
-
0036104074
-
Major bile duct injuries associated with laparoscopic cholecystectomy: Effect of surgical repair on quality of life
-
DOI 10.1097/00000658-200206000-00018
-
Melton GB, Lillemoe KD, Cameron JL, Sauter PA, Coleman J, Yeo CJ., (2002) Major bile duct injuries associated with laparoscopic cholecystectomy: effect of surgical repair on quality of life. Ann Surg 235: 888-895. (Pubitemid 34547309)
-
(2002)
Annals of Surgery
, vol.235
, Issue.6
, pp. 888-895
-
-
Melton, G.B.1
Lillemoe, K.D.2
Cameron, J.L.3
Sauter, P.A.4
Coleman, J.5
Yeo, C.J.6
-
12
-
-
77958155198
-
Current status and future of liver transplantation
-
Merion RM,. (2010) Current status and future of liver transplantation. Semin Liver Dis 30: 411-421.
-
(2010)
Semin Liver Dis
, vol.30
, pp. 411-421
-
-
Merion, R.M.1
-
13
-
-
0344121121
-
Rekonstruktion von Gallengangsdefekten mit Autologem Veneninterponat und Resorbierbarem Stent im Tiermodell: Technik und Klinische Bedeutung
-
DOI 10.1055/s-2003-44803
-
Heistermann HP, Palmes D, Hierlemann H,. (2003) Reconstruction of bile duct lesions by an autologous vein graft and a biodegradable endoluminal stent in an animal model: technique and clinical impact. Zentralbl Chir 128: 952-957. (Pubitemid 37489926)
-
(2003)
Zentralblatt fur Chirurgie
, vol.128
, Issue.11
, pp. 952-957
-
-
Heistermann, H.P.1
Palmes, D.2
Hierlemann, H.3
Ebsen, M.4
Horstmann, R.5
Hohlbach, G.6
Spiegel, H.U.7
-
14
-
-
72949084840
-
Morphological changes during creation of a neo-bile duct using a vein and a biodegradable endoluminal stent
-
Palmes D, Wolters H, Spiegel HU, M Ller E, Minin E, Heistermann HP,. (2009) Morphological changes during creation of a neo-bile duct using a vein and a biodegradable endoluminal stent. J Invest Surg 22: 435-444.
-
(2009)
J Invest Surg
, vol.22
, pp. 435-444
-
-
Palmes, D.1
Wolters, H.2
Spiegel, H.U.3
Ller E, M.4
Minin, E.5
Heistermann, H.P.6
-
15
-
-
0036366875
-
Repair of bile duct injuries with Gore-Tex vascular grafts: Experimental study in dogs
-
DOI 10.1016/S1091-255X(01)00038-5, PII S1091255X01000385
-
Gomez NA, Alvarez LR, Mite A, Andrade JP, Alvarez JR, Vargas PE, et al,. (2002) Repair of bile duct injuries with Gore-Tex vascular grafts: experimental study in dogs. J Gastrointest Surg 6: 116-120. (Pubitemid 40433598)
-
(2002)
Journal of Gastrointestinal Surgery
, vol.6
, Issue.1
, pp. 116-120
-
-
Gomez, N.A.1
Alvarez, L.R.2
Mite, A.3
Andrade, J.P.4
Alvarez, J.R.5
Vargas, P.E.6
Tomala, N.E.7
Vivas, A.F.8
Zapatier, J.A.9
-
16
-
-
22144476165
-
Reconstruction of the common bile duct by a vascular prosthetic graft: An experimental study in pigs
-
DOI 10.1007/s00534-005-0976-1
-
Christensen M, Laursen HB, Rokkjaer M, Jensen PF, Yasuda Y, Mortensen FV,. (2005) Reconstruction of the common bile duct by a vascular prosthetic graft: an experimental study in pigs. J Hepatobiliary Pancreat Surg 12: 231-234. (Pubitemid 40975524)
-
(2005)
Journal of Hepato-Biliary-Pancreatic Surgery
, vol.12
, Issue.3
, pp. 231-234
-
-
Christensen, M.1
Laursen, H.B.2
Rokkaer, M.3
Jensen, P.F.4
Yasuda, Y.5
Mortensen, F.V.6
-
17
-
-
34147110930
-
In situ engineering of the bile duct using polypropylene mesh-collagen tubes
-
Nakashima S, Nakamura T, Miyagawa K, Yoshikawa T, Kin S, Kuriu Y, et al,. (2007) In situ tissue engineering of the bile duct using polypropylene mesh-collagen tubes. Int J Artif Organs 30: 75-85. (Pubitemid 46566574)
-
(2007)
International Journal of Artificial Organs
, vol.30
, Issue.1
, pp. 75-85
-
-
Nakashima, S.1
Nakamura, T.2
Miyagawa, K.3
Yoshikawa, T.4
Kin, S.5
Kuriu, Y.6
Nakase, Y.7
Sakakura, C.8
Otsuji, E.9
Hagiwara, A.10
Yamagishi, H.11
|