메뉴 건너뛰기




Volumn 12, Issue 2, 2011, Pages 39-47

RapidArc quality assurance through MapCHECK

Author keywords

Ion chamber; Partial arc; RapidArc

Indexed keywords


EID: 79960542675     PISSN: None     EISSN: 15269914     Source Type: Journal    
DOI: 10.1120/jacmp.v12i2.3251     Document Type: Article
Times cited : (28)

References (7)
  • 1
    • 0029113269 scopus 로고
    • Intensity-modulated arc therapy with dynamic multileaf collimation: an alternative to tomotherapy
    • Yu, CX. Intensity-modulated arc therapy with dynamic multileaf collimation: an alternative to tomotherapy. Phys Med Biol. 1995;40(9):1435-50.
    • (1995) Phys Med Biol , vol.40 , Issue.9 , pp. 1435-1450
    • Yu, C.X.1
  • 2
    • 37549049393 scopus 로고    scopus 로고
    • Volumetric modulated arc therapy: IMRT in a single gantry arc
    • Otto K. Volumetric modulated arc therapy: IMRT in a single gantry arc. Med Phys. 2008;35(1):310-17.
    • (2008) Med Phys , vol.35 , Issue.1 , pp. 310-317
    • Otto, K.1
  • 3
    • 85024365796 scopus 로고    scopus 로고
    • Sun Nuclear Corporation. User's Guide, MapCHECK," version 3.2. Melbourne, FL: Sun Nuclear Corporation
    • Sun Nuclear Corporation. User's Guide, MapCHECK," version 3.2. Melbourne, FL: Sun Nuclear Corporation; 2006.
    • (2006)
  • 4
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307-10.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 5
    • 85024380102 scopus 로고    scopus 로고
    • Clinical implementation of the first RapidArc treatment within MOSAIQ environment: dosimetric validation and QA considerations [abstract]
    • st AAPM Annual Meeting, 2009 July 26-30; Anaheim, CA
    • st AAPM Annual Meeting, 2009 July 26-30; Anaheim, CA. Med Phys. 2009;36(6):2573.
    • (2009) Med Phys. , vol.36 , Issue.6 , pp. 2573
    • Kong, X.1    Wang, S.2
  • 6
    • 65449118359 scopus 로고    scopus 로고
    • Novel dosimetric phantom for quality assurance of volumetric modulated arc therapy
    • Létourneau D, Publicover J, Kozelka J, Moseley DJ, Jaffray DA. Novel dosimetric phantom for quality assurance of volumetric modulated arc therapy. Med Phys. 2009;36(5):1813-21.
    • (2009) Med Phys , vol.36 , Issue.5 , pp. 1813-1821
    • Létourneau, D.1    Publicover, J.2    Kozelka, J.3    Moseley, D.J.4    Jaffray, D.A.5
  • 7
    • 53149135069 scopus 로고    scopus 로고
    • The GLAaS algorithm for portal dosimetry and quality assurance of RapidArc, an intensity modulated rotational therapy
    • Nicolini G, Vanetti E, Clivio A, et al. The GLAaS algorithm for portal dosimetry and quality assurance of RapidArc, an intensity modulated rotational therapy. Radiat Oncol. 2008,3:24.
    • (2008) Radiat Oncol , vol.3 , pp. 24
    • Nicolini, G.1    Vanetti, E.2    Clivio, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.