메뉴 건너뛰기




Volumn 40, Issue 7, 2011, Pages 315-322

A how-to manual: The art of teaching buttonhole self-cannulation

(1)  Mott, Stuart a  

a NONE

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CANNULATION; DIALYSIS; EDUCATION; FINGER NAIL; HAND WASHING; HUMAN; INFORMATION; NEEDLE; PRIORITY JOURNAL; SCABIES; SELF HELP; SEPSIS; TECHNIQUE; VASCULAR ACCESS;

EID: 79960519095     PISSN: 00902934     EISSN: 19326920     Source Type: Journal    
DOI: 10.1002/dat.20586     Document Type: Article
Times cited : (1)

References (18)
  • 1
    • 0031656009 scopus 로고    scopus 로고
    • Hemodialysis access failure: A call to action
    • DOI 10.1046/j.1523-1755.1998.00122.x
    • Hakim R, Himmelfarb J. Hemodialysis access failure: A call to action. Kidney Int. 54(4), 1029-1040, 1998. (Pubitemid 28449890)
    • (1998) Kidney International , vol.54 , Issue.4 , pp. 1029-1040
    • Hakim, R.1    Himmelfarb, J.2
  • 2
    • 0242408269 scopus 로고    scopus 로고
    • Patency of autogenous and polytetranuoroerliylene upper extremity arteriovenous hemodialysis accesses: A systematic review
    • Huber, T S, Carter, J. Vf., Carter, K. L, & Seeger, J. M., Patency of autogenous and polytetranuoroerliylene upper extremity arteriovenous hemodialysis accesses: A systematic review, J Vase Surg. 38(5):1005-l011, 2O03.
    • (2003) J Vase Surg , vol.38 , Issue.5
    • Huber, T.S.1    Vf., C.J.2    Carter, K.L.3    Seeger, J.M.4
  • 3
    • 0002926115 scopus 로고
    • Statistical summary of clinical results of vascular access procedures for hemodialysis
    • ed B Sommersand M. Henry Precept Press Chicago, IL
    • Mehta S. Statistical summary of clinical results of vascular access procedures for hemodialysis. In Vascular Access for Hemodialysis, ed B Sommersand M. Henry, pp. 145-157, Precept Press Chicago, IL, 1991.
    • (1991) Vascular Access for Hemodialysis , pp. 145-157
    • Mehta, S.1
  • 4
    • 1542347830 scopus 로고    scopus 로고
    • Superiority of autogenous arteriovenous hemod Lily sis access: Maintenance of function widi fewer Secondary interventions
    • Perera, G. B., Mueller, M. P., Kubaska, S. M., Wilson, S. E., Lawrence, I' R, & Fujitani, K. M. Superiority of autogenous arteriovenous hemod Lily sis access: Maintenance of function widi fewer Secondary interventions, Ann Vase Surg, 18, 66-731 2004.
    • (2004) Ann Vase Surg , vol.18 , pp. 66-731
    • Perera, G.B.1    Mueller, M.P.2    Kubaska, S.M.3    Wilson, S.E.4    Lawrence, I.'.R.5    Fujitani, K.M.6
  • 6
    • 33845807146 scopus 로고    scopus 로고
    • KDOQ1 clinical practice recommendations for 2006 Updates: Hemodialysis adequacy, peritoneal dialysis adequacy and vascular access
    • National Kidney Foundation (NKF)
    • National Kidney Foundation (NKF). KDOQ1 clinical practice recommendations for 2006 Updates: Hemodialysis adequacy, peritoneal dialysis adequacy and vascular access. Am J Kidney Dis, 48(suppl 1), S1-S322, 2006.
    • (2006) Am J Kidney Dis , vol.48 , Issue.SUPPL. 1
  • 8
    • 33747195587 scopus 로고    scopus 로고
    • The buttonhole technique for arteriovenous fistula can-nulaiion
    • Ball LK The buttonhole technique for arteriovenous fistula can-nulaiion. Nephrol Nurs J. 33(3):299-304, 2006.
    • (2006) Nephrol Nurs J. , vol.33 , Issue.3 , pp. 299-304
    • Ball, L.K.1
  • 10
    • 60749117298 scopus 로고    scopus 로고
    • Research into pain perception with arteriovenous fistula (avf) cannulation
    • Figuerido AF, Viegas A, Monteiro M, Pol i-de-Figuei redo CF, Research into pain perception with arteriovenous fistula (avf) cannulation. J Ren Care. 34(4): 169-72, 2008.
    • (2008) J Ren Care , vol.34 , Issue.4 , pp. 169-72
    • Figuerido, A.F.1    Viegas, A.2    Monteiro, M.3    Poli-De-Figueiredo, C.F.4
  • 11
    • 79960521129 scopus 로고    scopus 로고
    • Burton hole needling of hemod [a]ys is arteriovenous hstulae results in less complications and interventions compared to the tope ladder technique
    • Sep 4 [Epub ahead of print]
    • Van Loon MM, Goovaerts T, Kessels AG, van der Sande FM, Tordoir J H. Burton hole needling of hemod [a]ys is arteriovenous hstulae results in less complications and interventions compared to the tope ladder technique. Nephrol Dial Transplant. 2009 Sep 4 [Epub ahead of print],
    • (2009) Nephrol Dial Transplant
    • Van Loon, M.M.1    Goovaerts, T.2    Kessels, A.G.3    Van Der Sande, F.M.4    Tordoir, J.H.5
  • 12
    • 0003168498 scopus 로고    scopus 로고
    • KDOQI Clinical' Practice Gitidelines jbr Hemodialytts Ad&jttaty, 2000
    • National Kidney Foundation (suppll)
    • National Kidney Foundation: KDOQI Clinical' Practice Gitidelines jbr Hemodialytts Ad&jttaty, 2000. Am J Kidney DLs 37:57-S64, 2001 (suppll)
    • (2001) Am J Kidney DLs , vol.37
  • 13
    • 77950138675 scopus 로고    scopus 로고
    • Fourth Edition. Module 5, Vascular Access. Editors: Lynda Ball, Tim Dillon, Lesley Dinwiddie, Janet E Holland. 200S Amgen Inc. Developed by die Medical Education Institute. Available for free in PDF form from
    • Core Curriculum for the Dialysis Technician: A Comprehensive Review of Hemodialysis. Fourth Edition. Module 5, Vascular Access. Editors: Lynda Ball, Tim Dillon, Lesley Dinwiddie, Janet E Holland. 200S Amgen Inc. Developed by die Medical Education Institute. Available for free in PDF form from http://www.ineiresearch.org.
    • Core Curriculum for the Dialysis Technician: A Comprehensive Review of Hemodialysis
  • 14
    • 69249220354 scopus 로고    scopus 로고
    • Using 'Tandem hand' teehiuque to facilitate self-eannulation in hemodialysis
    • Mott S, Moore H. Using 'Tandem hand' teehiuque to facilitate self-eannulation in hemodialysis. Nephrol Nurs J. 36(3):313-3166, 2009,
    • (2009) Nephrol Nurs J. , vol.36 , Issue.3 , pp. 313-3166
    • Mott, S.1    Moore, H.2
  • 15
    • 43549094461 scopus 로고    scopus 로고
    • The "touch cannulation" technique for hemodialysis
    • Mott S, Prowam BF, The "touch cannulation" technique for hemodialysis. Nephrol Nurs J, 35(l):65-66, 2008.
    • (2008) Nephrol Nurs J , vol.35 , Issue.1 , pp. 65-66
    • Mott, S.1    Prowam, B.F.2
  • 16
    • 0018640369 scopus 로고
    • Different sites versus constant sites of needle insertion into arteriovenous fistulas for treatment by repeated dialysis
    • Twardowski Z, Kubara H, Different sites versus constant sites of needle insertion into arteriovenous fistula for treatment by repeated dialysis. Dial Transplant 8:978-80, 1979. (Pubitemid 10189683)
    • (1979) Dialysis and Transplantation , vol.8 , Issue.10 , pp. 978-980
    • Twardowski, Z.1    Kubara, H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.