Volumn 4, Issue 2, 2011, Pages 156-163

Digital magnification mammography with matched incident exposure: Physical imaging properties and detectability of simulated microcalcifications

Author keywords

Computed radiography; Free response receiver operating characteristic (FROC) analysis; Magnification radiography; Microcalcification; Physical imaging properties

Indexed keywords

ARTICLE; BREAST CALCIFICATION; COMPUTER ASSISTED RADIOGRAPHY; CONTROLLED STUDY; DIGITAL MAGNIFICATION MAMMOGRAPHY; DIGITAL MAMMOGRAPHY; FREE RESPONSE RECEIVER OPERATING CHARACTERISTIC; IMAGE ANALYSIS; MODULATION TRANSFER FUNCTION; PHYSICAL PARAMETERS; PRIORITY JOURNAL; RADIATION DOSE DISTRIBUTION; RADIATION EXPOSURE; RADIODIAGNOSTIC EQUIPMENT AND SUPPLIES; RECEIVER OPERATING CHARACTERISTIC; SCATTER FUNCTION; SENSITIVITY AND SPECIFICITY; SIMULATION; WIENER SPECTRUM;

EID: 79960452355     PISSN: 18650333     EISSN: 18650341     Source Type: Journal    
DOI: 10.1007/s12194-011-0116-3     Document Type: Article
Times cited : (1)

References (20)
  • 1
    • 0016907373 scopus 로고
    • The detection and significance of calcifications in the breast: A radiological and pathological study
    • 1276572 10.1259/0007-1285-49-577-12 1:STN:280:DyaE283gslWnsQ%3D%3D
    • RR Millis R Davis AJ Stacey 1976 The detection and significance of calcifications in the breast: a radiological and pathological study Br J Radiol 49 577 12 26 1276572 10.1259/0007-1285-49-577-12 1:STN:280:DyaE283gslWnsQ%3D%3D
    • (1976) Br J Radiol , vol.49 , Issue.577 , pp. 12-26
    • Millis, R.R.1    Davis, R.2    Stacey, A.J.3
  • 2
    • 0020671613 scopus 로고
    • Microcalcification and its relationship to cancer of the breast: Experience in a screening clinic
    • DOI 10.1016/S0009-9260(83)80306-7
    • BB Muir J Lamb TJ Anderson, et al. 1983 Microcalcification and its relationship to cancer of breast: experience in a screening clinic Clin Radiol 34 2 193 200 6825401 10.1016/S0009-9260(83)80306-7 1:STN:280: DyaL3s7jtVaruw%3D%3D (Pubitemid 13157498)
    • (1983) Clinical Radiology , vol.34 , Issue.2 , pp. 193-200
    • Muir, B.B.1    Lamb, J.2    Anderson, T.J.3    Kirkpatrick, A.E.4
  • 3
    • 0023221956 scopus 로고
    • Digital mammography. ROC studies of the effects of pixel size and unsharp-mask filtering on the detection of subtle microcalcifications
    • HP Chan CJ Vyborny H MacMahon, et al. 1987 Digital mammography: ROC studies of the effects of pixel size and unsharp-mask filtering on the detection of subtle microcalcifications Invest Radiol 22 7 581 589 3623862 10.1097/00004424-198707000-00010 1:STN:280:DyaL2szgslanuw%3D%3D (Pubitemid 17136311)
    • (1987) Investigative Radiology , vol.22 , Issue.7 , pp. 581-589
    • Chan, H.-P.1    Vyborny, C.J.2    MacMahon, H.3
  • 4
    • 33645520861 scopus 로고    scopus 로고
    • Imaging properties of digital magnification radiography
    • 16696475 10.1118/1.2174133
    • SJ Boyce E Samei 2006 Imaging properties of digital magnification radiography Med Phys 33 4 984 996 16696475 10.1118/1.2174133
    • (2006) Med Phys , vol.33 , Issue.4 , pp. 984-996
    • Boyce, S.J.1    Samei, E.2
  • 5
    • 0032767558 scopus 로고    scopus 로고
    • Comparison of low contrast detectability between a digital amorphous silicon and a screen-film based imaging system for thoracic radiography
    • DOI 10.1118/1.598630
    • R Aufrichtig 1999 Comparison of low contrast detectability between a digital amorphous silicon and a screen-film based imaging system for thoracic radiography Med Phys 26 7 1349 1358 10435537 10.1118/1.598630 1:STN:280:DyaK1MzmtFyqsg%3D%3D (Pubitemid 29334803)
    • (1999) Medical Physics , vol.26 , Issue.7 , pp. 1349-1358
    • Aufrichtig, R.1
  • 6
    • 0037962482 scopus 로고    scopus 로고
    • Performance evaluation of a "dual-side read" dedicated mammography computed radiography system
    • DOI 10.1118/1.1584045
    • KA Fetterly BA Schueler 2003 Performance evaluation of a "dual-side read" dedicated mammography computed radiography system Med Phys 30 7 1843 1854 12906203 10.1118/1.1584045 (Pubitemid 36885803)
    • (2003) Medical Physics , vol.30 , Issue.7 , pp. 1843-1854
    • Fetterly, K.A.1    Schueler, B.A.2
  • 8
    • 46049110390 scopus 로고    scopus 로고
    • Proposal and verification of presampled MTF measurement by the simple analysis method using the edge method
    • (in Japanese)
    • R Higashide K Ichikawa H Kunitomo, et al. 2008 Proposal and verification of presampled MTF measurement by the simple analysis method using the edge method Jpn J Radiol Technol 64 4 417 425 (in Japanese)
    • (2008) Jpn J Radiol Technol , vol.64 , Issue.4 , pp. 417-425
    • Higashide, R.1    Ichikawa, K.2    Kunitomo, H.3
  • 9
    • 73349105910 scopus 로고    scopus 로고
    • Physical image quality assessment in digital radiography: Modulation transfer function-edge method
    • (in Japanese)
    • R Higashide 2009 Physical image quality assessment in digital radiography: modulation transfer function-edge method Jpn J Radiol Technol 65 10 1449 1456 (in Japanese)
    • (2009) Jpn J Radiol Technol , vol.65 , Issue.10 , pp. 1449-1456
    • Higashide, R.1
  • 10
    • 0030256430 scopus 로고    scopus 로고
    • Physical and clinical evaluation of a 2, 048 × 2, 048-matrix image intensifier TV digital imaging system in bone radiography
    • 8923903 10.1016/S1076-6332(96)80274-1 1:STN:280:DyaK2s%2Fot1KltQ%3D%3D
    • Y Higashida Y Baba M Hatemura, et al. 1996 Physical and clinical evaluation of a 2, 048 × 2, 048-matrix image intensifier TV digital imaging system in bone radiography Acad Radiol 3 10 842 848 8923903 10.1016/S1076-6332(96)80274-1 1:STN:280:DyaK2s%2Fot1KltQ%3D%3D
    • (1996) Acad Radiol , vol.3 , Issue.10 , pp. 842-848
    • Higashida, Y.1    Baba, Y.2    Hatemura, M.3
  • 11
    • 0021687319 scopus 로고
    • Investigation of basic imaging properties in digital radiography. 2. Noise Wiener spectrum
    • DOI 10.1118/1.595583
    • ML Giger K Doi CE Metz 1984 Investigation of basic imaging properties in digital radiography. 2. Noise Wiener spectrum Med Phys 11 6 797 805 6513887 10.1118/1.595583 1:STN:280:DyaL2M%2FosFyitw%3D%3D (Pubitemid 15223735)
    • (1984) Medical Physics , vol.11 , Issue.6 , pp. 797-805
    • Lissak Giger, M.1    Doi, K.2    Metz, C.E.3
  • 12
    • 4043065250 scopus 로고    scopus 로고
    • Determination of the detective quantum efficiency of a digital x-ray detector: Comparison of three evaluations using a common image data set
    • DOI 10.1118/1.1766421
    • U Neitzel S Günther-Kohfahl G Borasi, et al. 2004 Determination of the detective quantum efficiency of a digital X-ray detector: Comparison of three evaluations using a common image data set Med Phys 31 8 2205 2211 15377085 10.1118/1.1766421 (Pubitemid 39079711)
    • (2004) Medical Physics , vol.31 , Issue.8 , pp. 2205-2211
    • Neitzel, U.1    Gunther-Kohfahl, S.2    Borasi, G.3    Samei, E.4
  • 13
    • 33646455469 scopus 로고    scopus 로고
    • Intercomparison of methods for image quality characterization. II. Noise power spectrum
    • 16752581 10.1118/1.2188819
    • JT Dobbins 3rd E Samei NT Ranger, et al. 2006 Intercomparison of methods for image quality characterization. II. Noise power spectrum Med Phys 33 5 1466 1475 16752581 10.1118/1.2188819
    • (2006) Med Phys , vol.33 , Issue.5 , pp. 1466-1475
    • Dobbins III, J.T.1    Samei, E.2    Ranger, N.T.3
  • 14
    • 77949524653 scopus 로고    scopus 로고
    • Physical image quality assessment in digital radiography: Noise power spectrum
    • (in Japanese)
    • M Asahara 2009 Physical image quality assessment in digital radiography: noise power spectrum Jpn J Radiol Technol 65 12 1671 1679 (in Japanese)
    • (2009) Jpn J Radiol Technol , vol.65 , Issue.12 , pp. 1671-1679
    • Asahara, M.1
  • 15
    • 0024462154 scopus 로고
    • Maximum likelihood analysis of free-response receiver operating characteristic (FROC) data
    • DOI 10.1118/1.596358
    • DP Chakraborty 1989 Maximum likelihood analysis of free-response receiver operating characteristic (FROC) data Med Phys 16 4 561 568 2770630 10.1118/1.596358 1:STN:280:DyaL1MzmsVGjsg%3D%3D (Pubitemid 19224306)
    • (1989) Medical Physics , vol.16 , Issue.4 , pp. 561-568
    • Chakraborty, D.P.1
  • 16
    • 0025269074 scopus 로고
    • Free-response methodology: Alternate analysis and a new observer-performance experiment
    • DP Chakraborty LH Winter 1990 Free-response methodology: alternate analysis and a new observer-performance experiment Radiology 174 3 873 881 2305073 1:STN:280:DyaK3c7mtFWgsw%3D%3D (Pubitemid 20089690)
    • (1990) Radiology , vol.174 , Issue.3 , pp. 873-881
    • Chakraborty, D.P.1    Winter, L.H.L.2
  • 17
    • 62949121455 scopus 로고
    • Study of simple data sampling on free-response receiver operating (FROC) analysis
    • (in Japanese)
    • J Shiraishi K Kosakai M Hatagawa, et al. 1991 Study of simple data sampling on free-response receiver operating (FROC) analysis Jpn J Radiol Technol 47 4 620 626 (in Japanese)
    • (1991) Jpn J Radiol Technol , vol.47 , Issue.4 , pp. 620-626
    • Shiraishi, J.1    Kosakai, K.2    Hatagawa, M.3
  • 18
    • 12244309097 scopus 로고    scopus 로고
    • Maximum likelihood fitting of FROC curves under an initial-detection-and- candidate-analysis model
    • DOI 10.1118/1.1524631
    • DC Edwards MA Kupinski CE Metz, et al. 2002 Maximum likelihood fitting of FROC curves under an initial-detection-and-candidate-analysis model Med Phys 29 12 2861 2870 12512721 10.1118/1.1524631 (Pubitemid 36008482)
    • (2002) Medical Physics , vol.29 , Issue.12 , pp. 2861-2870
    • Edwards, D.C.1    Kupinski, M.A.2    Metz, C.E.3    Nishikawa, R.M.4
  • 19
    • 77957868684 scopus 로고    scopus 로고
    • Effect of dose reduction on the ability of digital mammography to detect simulated microcalcifications
    • Yakabe M, Sakai S, Yabuuchi H, et al. Effect of dose reduction on the ability of digital mammography to detect simulated microcalcifications. J Digit Imaging. 2010;23(5):520-6.
    • (2010) J Digit Imaging , vol.23 , Issue.5 , pp. 520-526
    • Yakabe, M.1    Sakai, S.2    Yabuuchi, H.3
  • 20
    • 24344468790 scopus 로고    scopus 로고
    • Breast dose from magnification films in mammography
    • DOI 10.1259/bjr/52648102
    • J Law 2005 Breast dose from magnification films in mammography Br J Radiol 78 933 816 820 16110103 10.1259/bjr/52648102 1:STN:280: DC%2BD2Mvkt1Wltw%3D%3D (Pubitemid 41246150)
    • (2005) British Journal of Radiology , vol.78 , Issue.933 , pp. 816-820
    • Law, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.