Volumn 36, Issue 9, 2011, Pages 776-780

Comparison of myocardial perfusion imaging using thallium-201 between a new cadmium-zinc-telluride cardiac camera and a conventional SPECT camera

Author keywords

CZT detectors; Myocardial perfusion imaging; SPECT; thallium 201

Indexed keywords

CADMIUM DERIVATIVE; CADMIUM ZINC TELLURIDE; THALLIUM 201; UNCLASSIFIED DRUG;

EID: 79960413406     PISSN: 03639762     EISSN: 15360229     Source Type: Journal    
DOI: 10.1097/RLU.0b013e31821a294e     Document Type: Article
Times cited : (36)

References (19)
  • 2
    • 0033527408 scopus 로고    scopus 로고
    • Long-term additive prognostic value of thallium-201 myocardial perfusion imaging over clinical and exercise stress test in low to intermediate risk patients: Study in 1137 patients with 6-year follow-up
    • Vanzetto G, Ormezzano O, Fagret D, et al. Long-term additive prognostic value of thallium-201 myocardial perfusion imaging over clinical and exercise stress test in low to intermediate risk patients: study in 1137 patients with 6-year follow-up. Circulation. 1999;100:1521-1527. (Pubitemid 29461464)
    • (1999) Circulation , vol.100 , Issue.14 , pp. 1521-1527
    • Vanzetto, G.1    Ormezzano, O.2    Fagret, D.3    Comet, M.4    Denis, B.5    Machecourt, J.6
  • 3
    • 0037133260 scopus 로고    scopus 로고
    • Value of stress myocardial perfusion single photon emission computed tomography in patients with normal resting electrocardiograms: An evaluation of incremental prognostic value and cost-effectiveness
    • DOI 10.1161/hc0702.103973
    • Hachamovitch R, Berman DS, Kiat H, et al. Value of stress myocardial perfusion single photon emission computed tomography in patients with normal resting electrocardiograms: an evaluation of incremental prognostic value and cost-effectiveness. Circulation. 2002;105:823-829. (Pubitemid 34174922)
    • (2002) Circulation , vol.105 , Issue.7 , pp. 823-829
    • Hachamovitch, R.1    Berman, D.S.2    Kiat, H.3    Cohen, I.4    Friedman, J.D.5    Shaw, L.J.6
  • 5
    • 67649994709 scopus 로고    scopus 로고
    • Advances in technical aspects of myocardial perfusion SPECT imaging
    • Slomka PJ, Patton JA, Berman DS, et al. Advances in technical aspects of myocardial perfusion SPECT imaging. J Nucl Cardiol. 2009;16:255-276.
    • (2009) J Nucl Cardiol , vol.16 , pp. 255-276
    • Slomka, P.J.1    Patton, J.A.2    Berman, D.S.3
  • 6
    • 41249099375 scopus 로고    scopus 로고
    • High-Speed Myocardial Perfusion Imaging. Initial Clinical Comparison With Conventional Dual Detector Anger Camera Imaging
    • DOI 10.1016/j.jcmg.2007.12.004, PII S1936878X08000077
    • Sharir T, Ben-Haim S, Merzon K, et al. High-speed myocardial perfusion imaging initial clinical comparison with conventional dual detector anger camera imaging. JACC Cardiovasc Imaging. 2008;1:156-163. (Pubitemid 351445405)
    • (2008) JACC: Cardiovascular Imaging , vol.1 , Issue.2 , pp. 156-163
    • Sharir, T.1    Ben-Haim, S.2    Merzon, K.3    Prochorov, V.4    Dickman, D.5    Ben-Haim, S.6    Berman, D.S.7
  • 7
    • 63849258734 scopus 로고    scopus 로고
    • A novel high-sensitivity rapidacquisition single-photon cardiac imaging camera
    • Gambhir SS, Berman DS, Ziffer J, et al. A novel high-sensitivity rapidacquisition single-photon cardiac imaging camera. J Nucl Med. 2009;50:635-643.
    • (2009) J Nucl Med , vol.50 , pp. 635-643
    • Gambhir, S.S.1    Berman, D.S.2    Ziffer, J.3
  • 8
    • 61649124737 scopus 로고    scopus 로고
    • Stress thallium-201/rest technetium-99m sequential dual isotope high-speed myocardial perfusion imaging
    • Berman DS, Kang X, Tamarappoo B, et al. Stress thallium-201/rest technetium-99m sequential dual isotope high-speed myocardial perfusion imaging. JACC Cardiovasc Imaging. 2009;2:273-282.
    • (2009) JACC Cardiovasc Imaging , vol.2 , pp. 273-282
    • Berman, D.S.1    Kang, X.2    Tamarappoo, B.3
  • 9
    • 77956185250 scopus 로고    scopus 로고
    • Simultaneous dual-radionuclide myocardial perfusion imaging with a solid-state dedicated cardiac camera
    • Ben-Haim S, Kacperski K, Hain S, et al. Simultaneous dual-radionuclide myocardial perfusion imaging with a solid-state dedicated cardiac camera. Eur J Nucl Med Mol Imaging. 2010;37:1710-1721.
    • (2010) Eur J Nucl Med Mol Imaging , vol.37 , pp. 1710-1721
    • Ben-Haim, S.1    Kacperski, K.2    Hain, S.3
  • 10
    • 72249112561 scopus 로고    scopus 로고
    • Novel solid-state-detector dedicated cardiac camera for fast myocardial perfusion imaging: Multicenter comparison with standard dual detector cameras
    • Esteves FP, Raggi P, Folks RD, et al. Novel solid-state-detector dedicated cardiac camera for fast myocardial perfusion imaging: multicenter comparison with standard dual detector cameras. J Nucl Cardiol. 2009;16:927-934.
    • (2009) J Nucl Cardiol , vol.16 , pp. 927-934
    • Esteves, F.P.1    Raggi, P.2    Folks, R.D.3
  • 11
    • 77952095021 scopus 로고    scopus 로고
    • Ultrafast nuclear myocardial perfusion imaging on a new gamma camera with semiconductor detector technique: First clinical validation
    • Buechel RR, Herzog BA, Husman L, et al. Ultrafast nuclear myocardial perfusion imaging on a new gamma camera with semiconductor detector technique: first clinical validation. Eur J Nucl Med Mol Imaging. 2010;37:773-778.
    • (2010) Eur J Nucl Med Mol Imaging , vol.37 , pp. 773-778
    • Buechel, R.R.1    Herzog, B.A.2    Husman, L.3
  • 12
    • 79952112024 scopus 로고    scopus 로고
    • A fast cardiac gamma camera with dynamic SPECT capabilities: Design, system validation and future potential
    • Bocher M, Blevis IM, Tsukerman L, et al. A fast cardiac gamma camera with dynamic SPECT capabilities: design, system validation and future potential. Eur J Nucl Med Mol Imaging. 2010;37:1887-1902.
    • (2010) Eur J Nucl Med Mol Imaging , vol.37 , pp. 1887-1902
    • Bocher, M.1    Blevis, I.M.2    Tsukerman, L.3
  • 13
    • 75149152483 scopus 로고    scopus 로고
    • Nuclear myocardial perfusion imaging with a Cadmium-Zinc-Telluride detector technique: Optimized protocol for scan time reduction
    • Herzog BA, Buechel RR, Katz R, et al. Nuclear myocardial perfusion imaging with a Cadmium-Zinc-Telluride detector technique: optimized protocol for scan time reduction. J Nucl Med. 2010;51:46-51.
    • (2010) J Nucl Med , vol.51 , pp. 46-51
    • Herzog, B.A.1    Buechel, R.R.2    Katz, R.3
  • 15
    • 77956949443 scopus 로고    scopus 로고
    • Single photon-emission computed tomography
    • Holly TA, Abbott BG, Al-Mallah M, et al. Single photon-emission computed tomography. J Nucl Cardiol. 2010;17:941-973.
    • (2010) J Nucl Cardiol , vol.17 , pp. 941-973
    • Holly, T.A.1    Abbott, B.G.2    Al-Mallah, M.3
  • 17
    • 0030478295 scopus 로고    scopus 로고
    • Tracer selection with different stress modalities based on tracer kinetics
    • Heller GV. Tracer selection with different stress modalities based on tracer kinetics. J Nucl Cardiol. 1996;3:S15-S21.
    • (1996) J Nucl Cardiol , vol.3
    • Heller, G.V.1
  • 18
    • 17844380794 scopus 로고    scopus 로고
    • Radiation-absorbed dose from 201Tl-thallous chloride
    • Thomas SR, Stabin MG, Castronovo FP. Radiation-absorbed dose from 201Tl-thallous chloride. J Nucl Med. 2005;46:502-508.
    • (2005) J Nucl Med , vol.46 , pp. 502-508
    • Thomas, S.R.1    Stabin, M.G.2    Castronovo, F.P.3
  • 19
    • 0024549209 scopus 로고
    • Prone decubitus: A solution to inferior wall attenuation in thallium-201 myocardial tomography
    • Esquerré JP, Coca F, Martinez S, et al. Prone decubitus: a solution to inferior wall attenuation in thallium-201 myocardial tomography. J Nucl Med. 1989;30:398-401. (Pubitemid 19077331)
    • (1989) Journal of Nuclear Medicine , vol.30 , Issue.3 , pp. 398-401
    • Esquerre, J.-P.1    Coca, F.J.2    Martinez, S.J.3    Guiraud, R.F.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.