메뉴 건너뛰기




Volumn 98 A, Issue 3, 2011, Pages 351-358

Understanding the impact of divalent cation substitution on hydroxyapatite: An in vitro multiparametric study on biocompatibility

Author keywords

apoptosis; biocompatibility; cytotoxicity; hydroxyapatite; metal ion release

Indexed keywords

ADHESION TEST; BIOCOMPATIBLE MATERIALS; BIOLOGICAL BEHAVIOR; BIOLOGICAL MEDIA; BONE TISSUE; CALCIUM SUBSTITUTION; CATIONIC SUBSTITUTION; CELL DENSITY; CHEMICAL ACTIVITIES; CRYSTALLINITIES; CYTOCOMPATIBILITY; DIVALENT CATION; IN-VITRO; MEMBRANE INTEGRITY; METAL ION RELEASE; METAL SPECIES; MITOCHONDRIAL ACTIVITY; PHYSICOCHEMICAL ANALYSIS; SURFACE DISSOLUTION;

EID: 79960368787     PISSN: 15493296     EISSN: 15524965     Source Type: Journal    
DOI: 10.1002/jbm.a.33126     Document Type: Article
Times cited : (78)

References (25)
  • 1
    • 0036166394 scopus 로고    scopus 로고
    • Properties of osteoconductive biomaterials: Calcium phosphates
    • LeGeros RZ,. Properties of osteoconductive biomaterials: Calcium phosphates. Clin Orthop Relat Res 2002; 395: 81-98.
    • (2002) Clin Orthop Relat Res , vol.395 , pp. 81-98
    • Legeros, R.Z.1
  • 2
    • 0036365413 scopus 로고    scopus 로고
    • Interfacial bioengineering to enhance surface biocompatibility
    • Lloyd AW,. Interfacial bioengineering to enhance surface biocompatibility. Med Device Technol 2002; 13: 18-21.
    • (2002) Med Device Technol , vol.13 , pp. 18-21
    • Lloyd, A.W.1
  • 4
    • 11144350098 scopus 로고    scopus 로고
    • A comparative study of biphasic calcium phosphate ceramics for human mesenchymal stem-cell-induced bone formation
    • DOI 10.1016/j.biomaterials.2004.09.035, PII S0142961204008646
    • Arinzeh TL, Tran T, Mcalary J, Daculsi G,. A comparative study of biphasic calcium phosphate ceramics for human mesenchymal stem-cell-induced bone formation. Biomaterials 2005; 26: 3631-3638. (Pubitemid 40038157)
    • (2005) Biomaterials , vol.26 , Issue.17 , pp. 3631-3638
    • Arinzeh, T.L.1    Tran, T.2    Mcalary, J.3    Daculsi, G.4
  • 8
    • 66049164593 scopus 로고    scopus 로고
    • The in vivo performance of biomagnetic hydroxyapatite nanoparticles in cancer hyperthermia therapy
    • Hou CH, Hou SM, Hsueh YS, Lin J, Wu HC, Lin FH,. The in vivo performance of biomagnetic hydroxyapatite nanoparticles in cancer hyperthermia therapy. Biomaterials 2009; 30: 3956-3960.
    • (2009) Biomaterials , vol.30 , pp. 3956-3960
    • Hou, C.H.1    Hou, S.M.2    Hsueh, Y.S.3    Lin, J.4    Wu, H.C.5    Lin, F.H.6
  • 11
    • 70349431106 scopus 로고    scopus 로고
    • Optimal cytocompatibility of a bioceramic nanoparticulate cement in primary human mesenchymal cells
    • De-Deus G, Canabarro A, Alves G, Linhares A, Senne MI, Granjeiro JM,. Optimal cytocompatibility of a bioceramic nanoparticulate cement in primary human mesenchymal cells. J Endod 2009; 35: 1387-1390.
    • (2009) J Endod , vol.35 , pp. 1387-1390
    • De-Deus, G.1    Canabarro, A.2    Alves, G.3    Linhares, A.4    Senne, M.I.5    Granjeiro, J.M.6
  • 14
    • 38349153562 scopus 로고    scopus 로고
    • The development of binary Mg-Ca alloys for use as biodegradable materials within bone
    • Li Z, Gu X, Lou S, Zheng Y,. The development of binary Mg-Ca alloys for use as biodegradable materials within bone. Biomaterials 2008; 29: 1329-1344.
    • (2008) Biomaterials , vol.29 , pp. 1329-1344
    • Li, Z.1    Gu, X.2    Lou, S.3    Zheng, Y.4
  • 17
    • 12144252769 scopus 로고    scopus 로고
    • Cytotoxicity of copper ions released from metal: Variation with the exposure period and concentration gradients
    • DOI 10.1385/BTER:102:1-3:129
    • Cortizo MC, Fernandez Lorenzo de MM,. Cytotoxicity of copper ions released from metal: Variation with the exposure period and concentration gradients. Biol Trace Elem Res 2004; 102: 129-141. (Pubitemid 40105013)
    • (2004) Biological Trace Element Research , vol.102 , Issue.1-3 , pp. 129-141
    • Cortizo, M.C.1    De Fernandez Lorenzo, M.M.2
  • 18
    • 38949101385 scopus 로고    scopus 로고
    • Relationship between radial diffusion of copper ions released from a metal disk and cytotoxic effects. Comparison with results obtained using extracts
    • Pereda MD, Reigosa M, Fernandez Lorenzo de MM,. Relationship between radial diffusion of copper ions released from a metal disk and cytotoxic effects. Comparison with results obtained using extracts. Bioelectrochemistry 2008; 72: 94-101.
    • (2008) Bioelectrochemistry , vol.72 , pp. 94-101
    • Pereda, M.D.1    Reigosa, M.2    Fernandez Lorenzo De M., M.3
  • 19
    • 4444312166 scopus 로고    scopus 로고
    • Metallic dental material biocompatibility in osteoblastlike cells: Correlation with metal ion release
    • DOI 10.1385/BTER:100:2:151
    • Cortizo MC, De Mele MF, Cortizo AM,. Metallic dental material biocompatibility in osteoblastlike cells: Correlation with metal ion release. Biol Trace Elem Res 2004; 100: 151-168. (Pubitemid 39178912)
    • (2004) Biological Trace Element Research , vol.100 , Issue.2 , pp. 151-168
    • Cortizo, M.C.1    De Mele, M.F.L.2    Cortizo, A.M.3
  • 20
    • 19144371451 scopus 로고    scopus 로고
    • Zinc-containing tricalcium phosphate and related materials for promoting bone formation
    • DOI 10.1016/j.cap.2004.10.006, PII S1567173905000039
    • Ito A, Otsuka M, Kawamura H, Ikeuchi M, Ohgushi H, Sogo Y, Ichinose N,. Zinc-containing tricalcium phosphate and related materials for promoting bone formation. Curr Appl Phys 2005; 5: 402-406. (Pubitemid 40714961)
    • (2005) Current Applied Physics , vol.5 , Issue.5 , pp. 402-406
    • Ito, A.1    Otsuka, M.2    Kawamura, H.3    Ikeuchi, M.4    Ohgushi, H.5    Sogo, Y.6    Ichinose, N.7
  • 22
    • 58849116909 scopus 로고    scopus 로고
    • Histomorphometric analysis of bone repair in critical size defect in rats calvaria treated with hydroxyapatite and zinc-containing hydroxyapatite 5%
    • Fernandes GVdO, Calazans-Maia MD, Mitri FF, Rossi AM, Almeida GDS, Granjeiro JM,. Histomorphometric analysis of bone repair in critical size defect in rats calvaria treated with hydroxyapatite and zinc-containing hydroxyapatite 5%. Key Eng Mater 2010; 396: 15-18.
    • (2010) Key Eng Mater , vol.396 , pp. 15-18
    • Fernandes, G.1    Calazans-Maia, M.D.2    Mitri, F.F.3    Rossi, A.M.4    Almeida, G.D.S.5    Granjeiro, J.M.6
  • 23
    • 3242774357 scopus 로고    scopus 로고
    • Hazards of heavy metal contamination
    • DOI 10.1093/bmb/ldg032
    • Jarup L,. Hazards of heavy metal contamination. Brit Med Bull 2003; 68: 167-182. (Pubitemid 38248496)
    • (2003) British Medical Bulletin , vol.68 , pp. 167-182
    • Jarup, L.1
  • 25
    • 77954681094 scopus 로고    scopus 로고
    • Evaluation of short-term effects of rare earth and other elements used in magnesium alloys on primary cells and cell lines
    • Feyerabend F, Fischer J, Holtz J, Witte F, Willumeit R, Drucker H, Vogt C, Hort N,. Evaluation of short-term effects of rare earth and other elements used in magnesium alloys on primary cells and cell lines. Acta Biomater 2010; 6: 1834-1842.
    • (2010) Acta Biomater , vol.6 , pp. 1834-1842
    • Feyerabend, F.1    Fischer, J.2    Holtz, J.3    Witte, F.4    Willumeit, R.5    Drucker, H.6    Vogt, C.7    Hort, N.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.