메뉴 건너뛰기




Volumn 66, Issue 5, 2011, Pages 378-382

Determination of mercury in airborne particulate matter collected on glass fiber filters using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sampling

Author keywords

Airborne particulate matter; Direct solid sampling analysis; Glass fiber filter; HR CS GF AAS; Mercury determination

Indexed keywords

AIRBORNE PARTICULATE MATTERS; DIRECT SOLID SAMPLING ANALYSIS; GLASS FIBER FILTER; HR-CS GF AAS; MERCURY DETERMINATION;

EID: 79960239408     PISSN: 05848547     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.sab.2011.05.004     Document Type: Conference Paper
Times cited : (39)

References (29)
  • 1
    • 79960219851 scopus 로고    scopus 로고
    • accessed on 01/10/2010.
    • http://www.atsdr.cdc.gov/toxprofiles/phs46.html accessed on 01/10/2010.
  • 2
    • 79960254353 scopus 로고    scopus 로고
    • accessed on 01/10/2010.
    • http://www.environmentwriter.org/resources/backissues/chemicals/mercury. htm accessed on 01/10/2010.
  • 3
    • 79960218053 scopus 로고    scopus 로고
    • accessed on 01/10/2010.
    • http://www.epa.gov accessed on 01/10/2010.
  • 4
    • 79960280405 scopus 로고    scopus 로고
    • accessed on 05/10/2010.
    • http://www.epa.gov/NCEA/iris/subst/0676.htm accessed on 05/10/2010.
  • 5
    • 79960279510 scopus 로고    scopus 로고
    • accessed on 05/10/2010.
    • http://www.atsdr.cdc.gov/toxprofiles/phs23.html accessed on 05/10/2010.
  • 6
    • 79960280852 scopus 로고    scopus 로고
    • accessed on 07/10/2010.
    • http://www.osha.gov/dts/chemicalsampling/data/CH-219100.html accessed on 07/10/2010.
  • 7
    • 0032532738 scopus 로고    scopus 로고
    • Canadian and U.S. sources impacting the mercury levels in fine atmospheric particulate material across New York State
    • DOI 10.1021/es980142h
    • I. Olmez, M.R. Ames, and G. Gullu Canadian and US sources impacting the mercury levels in fine atmospheric particulate material across New York State Environ. Sci. Technol. 32 1998 3048 3054 (Pubitemid 28485236)
    • (1998) Environmental Science and Technology , vol.32 , Issue.20 , pp. 3048-3054
    • Olmez, I.1    Ames, M.R.2    Gullu, G.3
  • 8
    • 0028580028 scopus 로고
    • The biogeochemical cycling of elemental mercury - Anthropogenic influences
    • R.P. Mason, W.F. Fitzgerald, and F.M.M. Morel The biogeochemical cycling of elemental mercury - anthropogenic influences Geochim. Cosmochim. Acta 58 1994 3191 3198
    • (1994) Geochim. Cosmochim. Acta , vol.58 , pp. 3191-3198
    • Mason, R.P.1    Fitzgerald, W.F.2    Morel, F.M.M.3
  • 9
    • 32844459684 scopus 로고    scopus 로고
    • Mercury concentrations in size-fractionated airborne particles at urban and suburban sites in Beijing, China
    • DOI 10.1016/j.atmosenv.2005.12.003, PII S1352231005011490
    • Z.W. Wang, X.S. Zhang, Z.S. Chen, and Y. Zhang Mercury concentrations in size-fractionated airborne particles at urban and suburban sites in Beijing China. Atmospheric Environ. 40 2006 2194 2201 (Pubitemid 43255226)
    • (2006) Atmospheric Environment , vol.40 , Issue.12 , pp. 2194-2201
    • Wang, Z.1    Zhang, X.2    Chen, Z.3    Zhang, Y.4
  • 10
    • 21244481722 scopus 로고    scopus 로고
    • Chemical vapor generation: Are further advances yet possible?
    • DOI 10.1007/s00216-005-3118-3
    • R.E. Sturgeon, X. Guo, and Z. Mester Chemical vapor generation: are further advances yet possible? Anal. Bioanal. Chem. 382 2005 881 883 (Pubitemid 40890944)
    • (2005) Analytical and Bioanalytical Chemistry , vol.382 , Issue.4 , pp. 881-883
    • Sturgeon, R.E.1    Guo, X.2    Mester, Z.3
  • 11
    • 77957892588 scopus 로고    scopus 로고
    • Determination of Rare Earth Elements (REEs) in Airborne Particulate Matter (APM) collected in Tokyo, Japan, and a positive anomaly of europium and terbium
    • Y. Suzuki, T. Suzuki, and N. Furuta Determination of Rare Earth Elements (REEs) in Airborne Particulate Matter (APM) collected in Tokyo, Japan, and a positive anomaly of europium and terbium Anal. Sci. 26 2010 929 935
    • (2010) Anal. Sci. , vol.26 , pp. 929-935
    • Suzuki, Y.1    Suzuki, T.2    Furuta, N.3
  • 14
    • 0037010569 scopus 로고    scopus 로고
    • Noble metals as permanent chemical modifiers for the determination of Mercury in environmental reference materials using solid sampling graphite furnace atomic absorption spectrometry and calibration against aqueous standards
    • A.F. da Silva, B. Welz, and A.J. Curtius Noble metals as permanent chemical modifiers for the determination of Mercury in environmental reference materials using solid sampling graphite furnace atomic absorption spectrometry and calibration against aqueous standards Spectrochim. Acta Part B 57 2002 2031 2045
    • (2002) Spectrochim. Acta Part B , vol.57 , pp. 2031-2045
    • Da Silva, A.F.1    Welz, B.2    Curtius, A.J.3
  • 15
    • 28944440138 scopus 로고    scopus 로고
    • Solid sampling-graphite furnace atomic absorption spectrometry for Hg monitoring in soils. Performance as a quantitative and as a screening method
    • DOI 10.1039/b509645f
    • M. Resano, E. Garcia-Ruiz, M. Aramendia, and M.A. Belarra Solid sampling graphite furnace atomic absorption spectrometry for Hg monitoring in soils. Performance as a quantitative and as a screening method J. Anal. At. Spectrom. 20 2005 1374 1380 (Pubitemid 41784456)
    • (2005) Journal of Analytical Atomic Spectrometry , vol.20 , Issue.12 , pp. 1374-1380
    • Resano, M.1    Garcia-Ruiz, E.2    Aramendia, M.3    Belarra, M.A.4
  • 16
    • 33750477004 scopus 로고    scopus 로고
    • Determination of mercury in biological samples using solid sampling high-resolution continuum source electrothermal atomization atomic absorption spectrometry with calibration against aqueous standards
    • DOI 10.1039/b607256a
    • A.F. da Silva, F.G. Lepri, D.L.G. Borges, B. Welz, A.J. Curtius, and U. Heitmann Determination of mercury in biological samples using solid sampling high-resolution continuum source electrothermal atomization atomic absorption spectrometry with calibration against aqueous standards J. Anal. At. Spectrom. 21 2006 1321 1326 (Pubitemid 44655403)
    • (2006) Journal of Analytical Atomic Spectrometry , vol.21 , Issue.11 , pp. 1321-1326
    • Da Silva, A.F.1    Lepri, F.G.2    Borges, D.L.G.3    Welz, B.4    Curtius, A.J.5    Heitmann, U.6
  • 17
    • 67651115663 scopus 로고    scopus 로고
    • Direct determination of Hg in polymers by solid sampling-graphite furnace atomic absorption spectrometry A comparison of the performance of line source and continuum source instrumentation
    • M. Resano, J. Briceno, and M.A. Belarra Direct determination of Hg in polymers by solid sampling-graphite furnace atomic absorption spectrometry A comparison of the performance of line source and continuum source instrumentation Spectrochim. Acta Part B 64 2009 520 529
    • (2009) Spectrochim. Acta Part B , vol.64 , pp. 520-529
    • Resano, M.1    Briceno, J.2    Belarra, M.A.3
  • 18
    • 77950222026 scopus 로고    scopus 로고
    • Determination of antimony in airborne particulate matter collected on filters using direct solid sampling and high-resolution continuum source graphite furnace atomic absorption spectrometry
    • R.G.O. Araujo, B. Welz, I.N.B. Castilho, M.G.R. Vale, P. Smichowski, S.L.C. Ferreira, and H. Becker-Ross Determination of antimony in airborne particulate matter collected on filters using direct solid sampling and high-resolution continuum source graphite furnace atomic absorption spectrometry J. Anal. At. Spectrom. 25 2010 580 584
    • (2010) J. Anal. At. Spectrom. , vol.25 , pp. 580-584
    • Araujo, R.G.O.1    Welz, B.2    Castilho, I.N.B.3    Vale, M.G.R.4    Smichowski, P.5    Ferreira, S.L.C.6    Becker-Ross, H.7
  • 19
    • 36649022068 scopus 로고    scopus 로고
    • Progress in direct solid sampling analysis using line source and high-resolution continuum source electrothermal atomic absorption spectrometry
    • DOI 10.1007/s00216-007-1555-x
    • B. Welz, M.G.R. Vale, D.L.G. Borges, and U. Heitmann Progress in direct solid sampling analysis using line source and high-resolution continuum source electrothermal atomic absorption spectrometry Anal. Bioanal. Chem. 389 2007 2085 2095 (Pubitemid 50000027)
    • (2007) Analytical and Bioanalytical Chemistry , vol.389 , Issue.7-8 , pp. 2085-2095
    • Welz, B.1    Vale, M.G.R.2    Borges, D.L.G.3    Heitmann, U.4
  • 21
    • 0000117646 scopus 로고    scopus 로고
    • Influence of the spectral bandwith of the spectrometer on the sensitivity using continuum source AAS
    • H. Becker-Ross, S. Florek, U. Heitmann, and R. Weisse Influence of the spectral bandwidth of the spectrometer on the sensitivity using continuum source AAS Fresenius J. Anal. Chem. 355 1996 300 303 (Pubitemid 126714428)
    • (1996) Fresenius' Journal of Analytical Chemistry , vol.355 , Issue.3-4 , pp. 300-303
    • Becker-Ross, H.1    Florek, S.2    Heitmann, U.3    Weisse, R.4
  • 22
    • 3042591065 scopus 로고    scopus 로고
    • Method development for the determination of nickel in petroleum using line-source and high-resolution continuum-source graphite furnace atomic absorption spectrometry
    • M.G.R. Vale, I.C.F. Damin, A. Klassen, M.M. Silva, B. Welz, A.F. Silva, F.G. Lepri, D.L.G. Borges, and U. Heitmann Method development for the determination of nickel in petroleum using line-source and high-resolution continuum-source graphite furnace atomic absorption spectrometry Microchem. J. 77 2004 131 140
    • (2004) Microchem. J. , vol.77 , pp. 131-140
    • Vale, M.G.R.1    Damin, I.C.F.2    Klassen, A.3    Silva, M.M.4    Welz, B.5    Silva, A.F.6    Lepri, F.G.7    Borges, D.L.G.8    Heitmann, U.9
  • 23
    • 2942687733 scopus 로고    scopus 로고
    • Method development for the determination of thallium in coal using solid sampling graphite furnace atomic absorption spectrometry with continuum source, high-resolution monochromator and CCD array detector
    • A.F. Silva, D.L.G. Borges, B. Welz, M.G.R. Vale, M.M. Silva, A. Klassen, and U. Heitmann Method development for the determination of thallium in coal using solid sampling graphite furnace atomic absorption spectrometry with continuum source, high-resolution monochromator and CCD array detector Spectrochim. Acta Part B 59 2004 841 850
    • (2004) Spectrochim. Acta Part B , vol.59 , pp. 841-850
    • Silva, A.F.1    Borges, D.L.G.2    Welz, B.3    Vale, M.G.R.4    Silva, M.M.5    Klassen, A.6    Heitmann, U.7
  • 24
    • 36248961687 scopus 로고    scopus 로고
    • Feasibility of peak volume, side pixel and multiple peak registration in high-resolution continuum source atomic absorption spectrometry
    • DOI 10.1016/j.sab.2007.10.011, PII S0584854707003321
    • U. Heitmann, B. Welz, D.L.G. Borges, and F.G. Lepri Feasibility of peak volume, side pixel and multiple peak registration in high-resolution continuum source atomic absorption spectrometry Spectrochim. Acta Part B 62 2007 1222 1230 (Pubitemid 350137644)
    • (2007) Spectrochimica Acta - Part B Atomic Spectroscopy , vol.62 , Issue.11 , pp. 1222-1230
    • Heitmann, U.1    Welz, B.2    Borges, D.L.G.3    Lepri, F.G.4
  • 25
    • 0031379583 scopus 로고    scopus 로고
    • Determination of mercury in soils and sediments by graphite furnace atomic absorption spectrometry with slurry sampling
    • PII S0584854797001043
    • I. López-García, M. Sánchez-Merlos, and M. Hernández-Córdoba Determination of mercury in soil and sediments by graphite furnace atomic absorption spectrometry with slurry sampling Spectrochim. Acta Part B 52 1997 2085 2092 (Pubitemid 127423055)
    • (1997) Spectrochimica Acta - Part B Atomic Spectroscopy , vol.52 , Issue.14 , pp. 2085-2092
    • Lopez-Garcia, I.1    Sanchez-Merlos, M.2    Hernandez-Cordoba, M.3
  • 26
    • 16344376216 scopus 로고    scopus 로고
    • Determination of mercury in sewage sludge by direct slurry sampling graphite furnace atomic absorption spectrometry
    • DOI 10.1016/j.sab.2005.01.010, PII S0584854705000157, 6th European Furnace Symposium and 11th Solid Sampling Colloquium with Atomic Spectrometry
    • D. Baralkiewicz, H. Gramowska, M. Kózka, and A. Kanecka Determination of mercury in sewage sludge by direct slurry sampling graphite furnace atomic absorption spectrometry Spectrochim. Acta Part B 60 2005 409 413 (Pubitemid 40467362)
    • (2005) Spectrochimica Acta - Part B Atomic Spectroscopy , vol.60 , Issue.3 , pp. 409-413
    • Baralkiewicz, D.1    Gramowska, H.2    Kozka, M.3    Kanecka, A.4
  • 27
    • 68149162017 scopus 로고    scopus 로고
    • A simple and fast approach for the determination of inorganic and total mercury in aqueous slurries of biological samples using cold vapor atomic absorption spectrometry and in situ oxidation
    • D.P. Torres, D.L.G. Borges, V.L.A. Frescura, and A.J. Curtius A simple and fast approach for the determination of inorganic and total mercury in aqueous slurries of biological samples using cold vapor atomic absorption spectrometry and in situ oxidation J. Anal. At. Spectrom. 24 2009 1118 1122
    • (2009) J. Anal. At. Spectrom. , vol.24 , pp. 1118-1122
    • Torres, D.P.1    Borges, D.L.G.2    Frescura, V.L.A.3    Curtius, A.J.4
  • 28
    • 37049066624 scopus 로고
    • Palladium nitrate-magnesium nitrate modifier for electrothermal atomic absorption spectrometry, Part 5. Performance for the determination of 21 elements
    • B. Welz, G. Schlemmer, and J.R. Mudakavi Palladium nitrate-magnesium nitrate modifier for electrothermal atomic absorption spectrometry, Part 5. Performance for the determination of 21 elements J. Anal. At. Spectrom. 7 1992 1257 1271
    • (1992) J. Anal. At. Spectrom. , vol.7 , pp. 1257-1271
    • Welz, B.1    Schlemmer, G.2    Mudakavi, J.R.3
  • 29
    • 0032977650 scopus 로고    scopus 로고
    • Sampling and determination of particulate mercury in ambient air: A review
    • DOI 10.1023/A:1005057022001
    • J.Y. Lu, and W.H. Schroeder Sampling and determination of particulate mercury in ambient air: a review Water Air Soil Pollut. 112 1999 279 295 (Pubitemid 29282533)
    • (1999) Water, Air, and Soil Pollution , vol.112 , Issue.3-4 , pp. 279-295
    • Lu, J.Y.1    Schroeder, W.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.