메뉴 건너뛰기




Volumn 36, Issue 12, 2011, Pages 3373-3385

Experimental evaluation of ventilated walls with an external clay cladding

Author keywords

Energy saving; Experimental study; Temperature distribution; Thermal performance; Ventilated fa ade; Ventilation channel

Indexed keywords

AIR CAVITY; AIR FLOW-RATE; AIR TEMPERATURE; AIR VELOCITIES; EXPERIMENTAL EVALUATION; EXPERIMENTAL STUDIES; EXTERNAL SURFACES; MEDITERRANEAN CLIMATES; PEAK TEMPERATURES; THERMAL BRIDGE; THERMAL LAG; THERMAL PERFORMANCE; THERMO-FLUID DYNAMICS; VENTILATED WALL; VENTILATION CHANNEL; VENTILATION CHANNELS;

EID: 79960199888     PISSN: 09601481     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.renene.2011.05.016     Document Type: Article
Times cited : (51)

References (11)
  • 1
    • 67349151137 scopus 로고    scopus 로고
    • Durability of 20-year-old external insulation and assessment of various types of retrofitting to meet new energy regulations
    • Stazi F., Di Perna C., Munafò P. Durability of 20-year-old external insulation and assessment of various types of retrofitting to meet new energy regulations. Energy and Buildings 2009, 41:721-731.
    • (2009) Energy and Buildings , vol.41 , pp. 721-731
    • Stazi, F.1    Di Perna, C.2    Munafò, P.3
  • 2
    • 0242406165 scopus 로고    scopus 로고
    • Ventilated facades energy performance in summer cooling of buildings
    • Ciampi M., Leccese F., Tuoni G. Ventilated facades energy performance in summer cooling of buildings. Solar Energy 2003, 75:491-502.
    • (2003) Solar Energy , vol.75 , pp. 491-502
    • Ciampi, M.1    Leccese, F.2    Tuoni, G.3
  • 4
    • 0036783404 scopus 로고    scopus 로고
    • Experimental studies of combined heat transfer in turbulent mixed convection fluid flows in double-skin-façades
    • Zöllner A., Winter E.R.F., Viskanta R. Experimental studies of combined heat transfer in turbulent mixed convection fluid flows in double-skin-façades. International Journal of Heat and Mass Transfer 2002, 45:4401-4408.
    • (2002) International Journal of Heat and Mass Transfer , vol.45 , pp. 4401-4408
    • Zöllner, A.1    Winter, E.R.F.2    Viskanta, R.3
  • 5
    • 14844298716 scopus 로고    scopus 로고
    • Possibilities and limitations of natural ventilation in restored industrial archaeology buildings with a double-skin façade in Mediterranean climates
    • Ballestini G., De Carli M., Masiero N., Tombola G. Possibilities and limitations of natural ventilation in restored industrial archaeology buildings with a double-skin façade in Mediterranean climates. Building and Environment 2005, 40:983-995.
    • (2005) Building and Environment , vol.40 , pp. 983-995
    • Ballestini, G.1    De Carli, M.2    Masiero, N.3    Tombola, G.4
  • 6
    • 71849118186 scopus 로고    scopus 로고
    • Experimental evaluation of a climate façade: energy efficiency and thermal comfort performance
    • Serra V., Zanghirella F., Perino M. Experimental evaluation of a climate façade: energy efficiency and thermal comfort performance. Energy and Buildings 2010, 42:50-62.
    • (2010) Energy and Buildings , vol.42 , pp. 50-62
    • Serra, V.1    Zanghirella, F.2    Perino, M.3
  • 7
    • 34447645795 scopus 로고    scopus 로고
    • Experimental assessment of the performance of an active transparent façade during actual operating conditions
    • Corgnati S.P., Perino M., Serra V. Experimental assessment of the performance of an active transparent façade during actual operating conditions. Solar Energy 2007, 81:993-1013.
    • (2007) Solar Energy , vol.81 , pp. 993-1013
    • Corgnati, S.P.1    Perino, M.2    Serra, V.3
  • 8
    • 2342512945 scopus 로고    scopus 로고
    • Experimental work on a linked, dynamic and ventilated, wall component
    • Dimoudi A., Androutsopoulos A., Lykoudis S. Experimental work on a linked, dynamic and ventilated, wall component. Energy and Buildings 2004, 36:443-453.
    • (2004) Energy and Buildings , vol.36 , pp. 443-453
    • Dimoudi, A.1    Androutsopoulos, A.2    Lykoudis, S.3
  • 9
    • 34147147527 scopus 로고    scopus 로고
    • Sustainable housing with mixed weight strategy - A case study
    • Mendonça P., Bragança L. Sustainable housing with mixed weight strategy - A case study. Building and Environment 2007, 42:3432-3443.
    • (2007) Building and Environment , vol.42 , pp. 3432-3443
    • Mendonça, P.1    Bragança, L.2
  • 10
    • 0030148990 scopus 로고    scopus 로고
    • Investigation of fluid flow and heat transfer in a vertical channel heated from one side by PV elements, part II - Experimental study
    • Sandberg M., Moshfegh B. Investigation of fluid flow and heat transfer in a vertical channel heated from one side by PV elements, part II - Experimental study. Renewable Energy 1996, 8:254-258.
    • (1996) Renewable Energy , vol.8 , pp. 254-258
    • Sandberg, M.1    Moshfegh, B.2
  • 11
    • 0036604726 scopus 로고    scopus 로고
    • A simple model to study ventilated facades energy performance
    • Balocco C. A simple model to study ventilated facades energy performance. Energy and Buildings 2002, 34:469-475.
    • (2002) Energy and Buildings , vol.34 , pp. 469-475
    • Balocco, C.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.