메뉴 건너뛰기




Volumn 27, Issue 6, 2011, Pages 417-426

LASIK flap thickness profile and reproducibility of the standard vs zero compression Hansatome microkeratomes: Three-dimensional display with artemis VHF digital ultrasound

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ADULT; ARTICLE; ATMOSPHERIC PRESSURE; CASE STUDY; CORNEA STROMA; CORNEA SURGERY; CORNEA THICKNESS; ECHOOCULOGRAPHY; EYE REFRACTION; HUMAN; KERATOMETRY; KERATOMILEUSIS; MAJOR CLINICAL STUDY; MYOPIA; OPTOMETRY; PACHOMETRY; PACHYMETRIC TOPOGRAPHY; POSTOPERATIVE PERIOD; PREOPERATIVE PERIOD; PRIORITY JOURNAL; REPRODUCIBILITY; RETROSPECTIVE STUDY; SURGICAL INSTRUMENT; THREE DIMENSIONAL IMAGING; TISSUE FLAP; TOPOGRAPHY; VACUUM; ZERO COMPRESSION HANSATOME MICROKERATOME;

EID: 79960167573     PISSN: 1081597X     EISSN: 19382391     Source Type: Journal    
DOI: 10.3928/1081597X-20101110-01     Document Type: Article
Times cited : (20)

References (41)
  • 1
    • 33751118002 scopus 로고    scopus 로고
    • Probability model of the inaccuracy of residual stromal thickness prediction to reduce the risk of ectasia after LASIK part I: Quantifying individual risk
    • Reinstein DZ, Srivannaboon S, Archer TJ, Silverman RH, Sutton H, Coleman DJ. Probability model of the inaccuracy of residual stromal thickness prediction to reduce the risk of ectasia after LASIK part I: quantifying individual risk. J Refract Surg. 2006;22(9):851-860. (Pubitemid 44764567)
    • (2006) Journal of Refractive Surgery , vol.22 , Issue.9 , pp. 851-860
    • Reinstein, D.Z.1    Srivannaboon, S.2    Archer, T.J.3    Silverman, R.H.4    Sutton, H.5    Coleman, D.J.6
  • 2
    • 33751082708 scopus 로고    scopus 로고
    • Probability model of the inaccuracy of residual stromal thickness prediction to reduce the risk of ectasia after LASIK part II: Quantifying population risk
    • Reinstein DZ, Srivannaboon S, Archer TJ, Silverman RH, Sutton H, Coleman DJ. Probability model of the inaccuracy of residual stromal thickness prediction to reduce the risk of ectasia after LASIK part II: quantifying population risk. J Refract Surg. 2006;22(9):861-870. (Pubitemid 44767500)
    • (2006) Journal of Refractive Surgery , vol.22 , Issue.9 , pp. 861-870
    • Reinstein, D.Z.1    Srivannaboon, S.2    Archer, T.J.3    Silverman, R.H.4    Sutton, H.5    Coleman, D.J.6
  • 4
    • 0033818828 scopus 로고    scopus 로고
    • Etiology of buttonhole flaps
    • Pulaski JP. Etiology of buttonhole flaps. J Cataract Refract Surg. 2000;26(9):1270-1271.
    • (2000) J Cataract Refract Surg , vol.26 , Issue.9 , pp. 1270-1271
    • Pulaski, J.P.1
  • 6
    • 0034821180 scopus 로고    scopus 로고
    • Refractive surgical problem
    • Reinstein DZ. Refractive surgical problem. J Cataract Refract Surg. 2001;27(9):1350-1352.
    • (2001) J Cataract Refract Surg , vol.27 , Issue.9 , pp. 1350-1352
    • Reinstein, D.Z.1
  • 8
    • 77957669157 scopus 로고    scopus 로고
    • Repeatability of layered corneal pachymetry with the Artemis very high-frequency digital ultrasound arc-scanner
    • Reinstein DZ, Archer TJ, Gobbe M, Silverman RH, Coleman DJ. Repeatability of layered corneal pachymetry with the Artemis very high-frequency digital ultrasound arc-scanner. J Refract Surg. 2010;26(9):646-659.
    • (2010) J Refract Surg , vol.26 , Issue.9 , pp. 646-659
    • Reinstein, D.Z.1    Archer, T.J.2    Gobbe, M.3    Silverman, R.H.4    Coleman, D.J.5
  • 9
    • 33646709673 scopus 로고    scopus 로고
    • Evaluating microkeratome efficacy by 3D corneal lamellar flap thickness accuracy and reproducibility using Artemis VHF digital ultrasound arc-scanning
    • Reinstein DZ, Sutton HF, Srivannaboon S, Silverman RH, Archer TJ, Coleman DJ. Evaluating microkeratome efficacy by 3D corneal lamellar flap thickness accuracy and reproducibility using Artemis VHF digital ultrasound arc-scanning. J Refract Surg. 2006;22(5):431-440. (Pubitemid 43736469)
    • (2006) Journal of Refractive Surgery , vol.22 , Issue.5 , pp. 431-440
    • Reinstein, D.Z.1    Sutton, H.F.S.2    Srivannaboon, S.3    Silverman, R.H.4    Archer, T.J.5    Coleman, D.J.6
  • 10
    • 13844305846 scopus 로고    scopus 로고
    • Randomized prospective clinical study comparing induced aberrations with IntraLase and Hansatome flap creation in fellow eyes: Potential impact on wavefront-guided laser in situ keratomileusis
    • DOI 10.1016/j.jcrs.2004.10.037
    • Tran DB, Sarayba MA, Bor Z, Garufis C, Duh YJ, Soltes CR, Juhasz T, Kurtz RM. Randomized prospective clinical study comparing induced aberrations with IntraLase and Hansatome flap creation in fellow eyes: potential impact on wavefront-guided laser in situ keratomileusis. J Cataract Refract Surg. 2005;31(1):97-105. (Pubitemid 40260696)
    • (2005) Journal of Cataract and Refractive Surgery , vol.31 , Issue.1 , pp. 97-105
    • Tran, D.B.1    Sarayba, M.A.2    Bor, Z.3    Garufis, C.4    Duh, Y.-J.5    Soltes, C.R.6    Juhasz, T.7    Kurtz, R.M.8
  • 11
    • 13844317415 scopus 로고    scopus 로고
    • Femtosecond laser versus mechanical keratome flaps in wavefront-guided laser in situ keratomileusis: Prospective contralateral eye study
    • DOI 10.1016/j.jcrs.2004.09.046
    • Durrie DS, Kezirian GM. Femtosecond laser versus mechanical keratome flaps in wavefront-guided laser in situ keratomileusis: prospective contralateral eye study. J Cataract Refract Surg. 2005;31(1):120-126. (Pubitemid 40260699)
    • (2005) Journal of Cataract and Refractive Surgery , vol.31 , Issue.1 , pp. 120-126
    • Durrie, D.S.1    Kezirian, G.M.2
  • 13
    • 13544271252 scopus 로고    scopus 로고
    • Comparison of the IntraLase femtosecond laser and mechanical keratomes for laser in situ keratomileusis
    • DOI 10.1016/j.jcrs.2003.10.026, PII S0886335003010496
    • Kezirian GM, Stonecipher KG. Comparison of the IntraLase femtosecond laser and mechanical keratomes for laser in situ keratomileusis. J Cataract Refract Surg. 2004;30(4):804-811. (Pubitemid 38501473)
    • (2004) Journal of Cataract and Refractive Surgery , vol.30 , Issue.4 , pp. 804-811
    • Kezirian, G.M.1    Stonecipher, K.G.2
  • 14
    • 37349017980 scopus 로고    scopus 로고
    • Flap thickness reproducibility in laser in situ keratomileusis with a femtosecond laser: Optical coherence tomography measurement
    • DOI 10.1016/j.jcrs.2007.08.036, PII S0886335007017762
    • Kim JH, Lee D, Rhee KI. Flap thickness reproducibility in laser in situ keratomileusis with a femtosecond laser: optical coherence tomography measurement. J Cataract Refract Surg. 2008;34(1):132-136. (Pubitemid 350299780)
    • (2008) Journal of Cataract and Refractive Surgery , vol.34 , Issue.1 , pp. 132-136
    • Kim, J.-H.1    Lee, D.2    Rhee, K.-I.3
  • 15
    • 33747037219 scopus 로고    scopus 로고
    • Advances in refractive surgery: Microkeratome and femtosecond laser flap creation in relation to safety, efficacy, predictability, and biomechanical stability
    • DOI 10.1097/01.icu.0000233957.88509.2d, PII 0005573520060800000010
    • Stonecipher K, Ignacio TS, Stonecipher M. Advances in refractive surgery: microkeratome and femtosecond laser flap creation in relation to safety, efficacy, predictability, and biomechanical stability. Curr Opin Ophthalmol. 2006;17(4):368-372. (Pubitemid 44215047)
    • (2006) Current Opinion in Ophthalmology , vol.17 , Issue.4 , pp. 368-372
    • Stonecipher, K.1    Ignacio, T.S.2    Stonecipher, M.3
  • 17
    • 34249710403 scopus 로고    scopus 로고
    • A longitudinal study of LASIK flap and stromal thickness with high-speed optical coherence tomography
    • Li Y, Netto MV, Shekhar R, Krueger RR, Huang D. A longitudinal study of LASIK flap and stromal thickness with high-speed optical coherence tomography. Ophthalmology. 2007;114(6):1124-1132.
    • (2007) Ophthalmology , vol.114 , Issue.6 , pp. 1124-1132
    • Li, Y.1    Netto, M.V.2    Shekhar, R.3    Krueger, R.R.4    Huang, D.5
  • 18
    • 0035989292 scopus 로고    scopus 로고
    • Factors that affect corneal flap thickness with the Hansatome microkeratome
    • Gailitis RP, Lagzdins M. Factors that affect corneal flap thickness with the Hansatome microkeratome. J Refract Surg. 2002;18(4):439-443. (Pubitemid 34815477)
    • (2002) Journal of Refractive Surgery , vol.18 , Issue.4 , pp. 439-443
    • Gailitis, R.P.1    Lagzdins, M.2
  • 19
    • 0036579844 scopus 로고    scopus 로고
    • Predictability of corneal flap thickness in laser in situ keratomileusis using three different microkeratomes
    • Shemesh G, Dotan G, Lipshitz I. Predictability of corneal flap thickness in laser in situ keratomileusis using three different microkeratomes. J Refract Surg. 2002;18(3 Suppl):S347-S351.
    • (2002) J Refract Surg , vol.18 , Issue.3 SUPPL.
    • Shemesh, G.1    Dotan, G.2    Lipshitz, I.3
  • 20
    • 4644311394 scopus 로고    scopus 로고
    • Comparison of corneal flap thickness between primary and fellow eyes using three microkeratomes
    • Shemesh G, Leibovitch I, Lipshitz I. Comparison of corneal flap thickness between primary and fellow eyes using three microkeratomes. J Refract Surg. 2004;20(5):417-421. (Pubitemid 39299534)
    • (2004) Journal of Refractive Surgery , vol.20 , Issue.5 , pp. 417-421
    • Shemesh, G.1    Leibovitch, I.2    Lipshitz, I.3
  • 22
    • 77949398250 scopus 로고    scopus 로고
    • Accuracy and reproducibility of Artemis central flap thickness and visual outcomes of LASIK with the Carl Zeiss Meditec VisuMax femtosecond laser and MEL 80 excimer laser platforms
    • Reinstein DZ, Archer TJ, Gobbe M, Johnson N. Accuracy and reproducibility of Artemis central flap thickness and visual outcomes of LASIK with the Carl Zeiss Meditec VisuMax femtosecond laser and MEL 80 excimer laser platforms. J Refract Surg. 2010;26(2):107-119.
    • (2010) J Refract Surg , vol.26 , Issue.2 , pp. 107-119
    • Reinstein, D.Z.1    Archer, T.J.2    Gobbe, M.3    Johnson, N.4
  • 26
    • 33751032366 scopus 로고    scopus 로고
    • Artemis very high-frequency digital ultrasound-guided repositioning of a free cap after laser in situ keratomileusis
    • Reinstein DZ, Rothman RC, Couch DG, Archer TJ. Artemis very high-frequency digital ultrasound-guided repositioning of a free cap after laser in situ keratomileusis. J Cataract Refract Surg. 2006;32(11):1877-1882.
    • (2006) J Cataract Refract Surg , vol.32 , Issue.11 , pp. 1877-1882
    • Reinstein, D.Z.1    Rothman, R.C.2    Couch, D.G.3    Archer, T.J.4
  • 27
    • 33751033654 scopus 로고    scopus 로고
    • Combined Artemis very high-frequency digital ultrasound-assisted transepithelial phototherapeutic keratectomy and wavefront-guided treatment following multiple corneal refractive procedures
    • DOI 10.1016/j.jcrs.2006.07.016, PII S0886335006010467
    • Reinstein DZ, Archer T. Combined Artemis very high-frequency digital ultrasound-assisted transepithelial phototherapeutic keratectomy and wavefront-guided treatment following multiple corneal refractive procedures. J Cataract Refract Surg. 2006;32(11):1870-1876. (Pubitemid 44754918)
    • (2006) Journal of Cataract and Refractive Surgery , vol.32 , Issue.11 , pp. 1870-1876
    • Reinstein, D.Z.1    Archer, T.2
  • 28
    • 33751039313 scopus 로고    scopus 로고
    • Direct residual stromal thickness measurement for assessing suitability for LASIK enhancement by Artemis 3D very high-frequency digital ultrasound arc scanning
    • DOI 10.1016/j.jcrs.2006.08.020, PII S0886335006010509
    • Reinstein DZ, Couch DG, Archer T. Direct residual stromal thickness measurement for assessing suitability for LASIK enhancement by Artemis 3D very high-frequency digital ultrasound arc scanning. J Cataract Refract Surg. 2006;32(11):1884-1888. (Pubitemid 44754921)
    • (2006) Journal of Cataract and Refractive Surgery , vol.32 , Issue.11 , pp. 1884-1888
    • Reinstein, D.Z.1    Couch, D.G.2    Archer, T.3
  • 29
    • 0028084929 scopus 로고
    • Epithelial and corneal thickness measurements by high-frequency ultrasound digital signal processing
    • Reinstein DZ, Silverman RH, Rondeau MJ, Coleman DJ. Epithelial and corneal thickness measurements by high-frequency ultrasound digital signal processing. Ophthalmology. 1994;101(1):140-146. (Pubitemid 24044155)
    • (1994) Ophthalmology , vol.101 , Issue.1 , pp. 140-146
    • Reinstein, D.Z.1    Silverman, R.H.2    Rondeau, M.J.3    Coleman, D.J.4
  • 31
    • 0027427552 scopus 로고
    • High-frequency ultrasound measurement of the thickness of the corneal epithelium
    • Reinstein DZ, Silverman RH, Coleman DJ. High-frequency ultrasound measurement of the thickness of the corneal epithelium. Refract Corneal Surg. 1993;9(5):385-387. (Pubitemid 23300161)
    • (1993) Refractive and Corneal Surgery , vol.9 , Issue.5 , pp. 385-387
    • Reinstein, D.Z.1    Silverman, R.H.2    Coleman, D.J.3
  • 32
    • 0034537228 scopus 로고    scopus 로고
    • Reproducibility of corneal flap thickness in laser in situ keratomileusis using the Hansatome microkeratome
    • Yildirim R, Aras C, Ozdamar A, Bahcecioglu H, Ozkan S. Reproducibility of corneal flap thickness in laser in situ keratomileusis using the Hansatome microkeratome. J Cataract Refract Surg. 2000;26(12):1729-1732.
    • (2000) J Cataract Refract Surg , vol.26 , Issue.12 , pp. 1729-1732
    • Yildirim, R.1    Aras, C.2    Ozdamar, A.3    Bahcecioglu, H.4    Ozkan, S.5
  • 33
  • 35
    • 18844387066 scopus 로고    scopus 로고
    • Factors predictive of LASIK flap thickness with the hansatome zero compression microkeratome
    • Choudhri SA, Feigenbaum SK, Pepose JS. Factors predictive of LASIK flap thickness with the Hansatome zero compression microkeratome. J Refract Surg. 2005;21(3):253-259. (Pubitemid 40696244)
    • (2005) Journal of Refractive Surgery , vol.21 , Issue.3 , pp. 253-259
    • Choudhri, S.A.1    Feigenbaum, S.K.2    Pepose, J.S.3
  • 36
    • 33644688010 scopus 로고    scopus 로고
    • Laser in situ keratomileusis flap thickness using the Hansatome microkeratome with zero compression heads
    • DOI 10.1016/j.jcrs.2005.07.042, PII S088633500500893X
    • Taneri S. Laser in situ keratomileusis flap thickness using the Hansatome microkeratome with zero compression heads. J Cataract Refract Surg. 2006;32(1):72-77. (Pubitemid 43330052)
    • (2006) Journal of Cataract and Refractive Surgery , vol.32 , Issue.1 , pp. 72-77
    • Taneri, S.1
  • 37
    • 34547118597 scopus 로고    scopus 로고
    • Comparative performance of the Zyoptix XP and Hansatome zero-compression microkeratomes
    • DOI 10.1016/j.jcrs.2007.04.014, PII S0886335007007316
    • Pepose JS, Feigenbaum SK, Qazi MA, Merchea M. Comparative performance of the Zyoptix XP and Hansatome zero-compression microkeratomes. J Cataract Refract Surg. 2007;33(8):1386-1391. (Pubitemid 47096682)
    • (2007) Journal of Cataract and Refractive Surgery , vol.33 , Issue.8 , pp. 1386-1391
    • Pepose, J.S.1    Feigenbaum, S.K.2    Qazi, M.A.3    Merchea, M.4
  • 38
    • 64849091229 scopus 로고    scopus 로고
    • Femtosecond laser versus mechanical microkeratomes for flap creation in laser in situ keratomileusis and effect of postoperative measurement interval on estimated femtosecond flap thickness
    • Rosa AM, Neto Murta J, Quadrado MJ, Tavares C, Lobo C, Van Velze R, Castanheira-Dinis A. Femtosecond laser versus mechanical microkeratomes for flap creation in laser in situ keratomileusis and effect of postoperative measurement interval on estimated femtosecond flap thickness. J Cataract Refract Surg. 2009;35(5):833-838.
    • (2009) J Cataract Refract Surg , vol.35 , Issue.5 , pp. 833-838
    • Rosa, A.M.1    Neto Murta, J.2    Quadrado, M.J.3    Tavares, C.4    Lobo, C.5    Van Velze, R.6    Castanheira-Dinis, A.7
  • 40
    • 64849099776 scopus 로고    scopus 로고
    • Incidence, management, and visual outcomes of buttonholed laser in situ keratomileusis flaps
    • Al-Mezaine HS, Al-Amro SA, Al-Obeidan S. Incidence, management, and visual outcomes of buttonholed laser in situ keratomileusis flaps. J Cataract Refract Surg. 2009;35(5):839-845.
    • (2009) J Cataract Refract Surg , vol.35 , Issue.5 , pp. 839-845
    • Al-Mezaine, H.S.1    Al-Amro, S.A.2    Al-Obeidan, S.3
  • 41
    • 77952950937 scopus 로고    scopus 로고
    • Flap buttonhole in thin-flap laser in situ keratomileusis: Case series and review
    • Jain V, Mhatre K, Shome D. Flap buttonhole in thin-flap laser in situ keratomileusis: case series and review. Cornea. 2010;29(6):655-658.
    • (2010) Cornea , vol.29 , Issue.6 , pp. 655-658
    • Jain, V.1    Mhatre, K.2    Shome, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.