메뉴 건너뛰기




Volumn 31, Issue 5, 2011, Pages 360-364

Lower extremity free flap reconstruction outcomes using venous coupler

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTERY ANASTOMOSIS; ARTICLE; FEMALE; FLAP SURVIVAL; FREE TISSUE GRAFT; GRAFT FAILURE; HEMATOMA; HUMAN; LIMB SALVAGE; LOWER EXTREMITY FREE FLAP RECONSTRUCTION; MAJOR CLINICAL STUDY; MALE; MICROVASCULAR SURGERY; POSTOPERATIVE COMPLICATION; POSTOPERATIVE INFECTION; PRIORITY JOURNAL; RETROSPECTIVE STUDY; SKIN GRAFT LOSS; SURGICAL EQUIPMENT; SURVIVAL; SURVIVAL RATE; TREATMENT OUTCOME; VEIN ANASTOMOSIS; VENOUS COUPLER;

EID: 79960155546     PISSN: 07381085     EISSN: 10982752     Source Type: Journal    
DOI: 10.1002/micr.20888     Document Type: Article
Times cited : (44)

References (37)
  • 1
    • 0000069449 scopus 로고
    • New method of surgical treatment of blood vessel lesions
    • Androsov PI,. New method of surgical treatment of blood vessel lesions. AMA Arch Surg 1956; 73: 902-910.
    • (1956) AMA Arch Surg , vol.73 , pp. 902-910
    • Androsov, P.I.1
  • 2
    • 0000399368 scopus 로고
    • A simple new apparatus for small vessel anastomosisi (free autograft of the sigmoid included)
    • Nakayama K, Tamiya T, Yamamoto K, Akimoto S,. A simple new apparatus for small vessel anastomosisi (free autograft of the sigmoid included). Surgery 1962; 52: 918-931.
    • (1962) Surgery , vol.52 , pp. 918-931
    • Nakayama, K.1    Tamiya, T.2    Yamamoto, K.3    Akimoto, S.4
  • 3
    • 0022830388 scopus 로고
    • The UNILINK instrument system for fast and safe microvascular anastomosis
    • Ostrup LT, Berggren A,. The UNILINK instrument system for fast and safe microvascular anastomosis. Ann Plast Surg 1986; 17: 521-525. (Pubitemid 17222229)
    • (1986) Annals of Plastic Surgery , vol.17 , Issue.6 , pp. 521-525
    • Ostrup, L.T.1    Berggren, A.2
  • 4
    • 77953794747 scopus 로고    scopus 로고
    • Venous coupler for free-flap anastomosis: Outcomes of 1,000 cases
    • Rozen WM, Whitaker IS, Acosta R,. Venous coupler for free-flap anastomosis: Outcomes of 1,000 cases. Anticancer Res 2010; 30: 1293-1294.
    • (2010) Anticancer Res , vol.30 , pp. 1293-1294
    • Rozen, W.M.1    Whitaker, I.S.2    Acosta, R.3
  • 5
    • 77749328262 scopus 로고    scopus 로고
    • 1000 consecutive venous anastomoses using the microvascular anastomotic coupler in breast reconstruction
    • Jandali S, Wu LC, Vega SJ, Kovach SJ, Serletti JM,. 1000 consecutive venous anastomoses using the microvascular anastomotic coupler in breast reconstruction. Plast Reconstr Surg 2010; 125: 792-798.
    • (2010) Plast Reconstr Surg , vol.125 , pp. 792-798
    • Jandali, S.1    Wu, L.C.2    Vega, S.J.3    Kovach, S.J.4    Serletti, J.M.5
  • 6
    • 0024546631 scopus 로고
    • The UNILINK system for mechanical microvascular anastomosis in hand surgery
    • Nylander G, Ragnarsson R, Berggren A, Ostrup LT,. The UNILINK system for mechanical microvascular anastomosis in hand surgery. J Hand Surg Am 1989; 14: 44-48. (Pubitemid 19043345)
    • (1989) Journal of Hand Surgery , vol.14 , Issue.1 , pp. 44-48
    • Nylander, G.1    Ragnarsson, R.2    Berggren, A.3    Ostrup, L.T.4
  • 8
    • 0028303128 scopus 로고
    • Clinical experience with the 3M microvascular coupling anastomotic device in 100 free-tissue transfers
    • DOI 10.1097/00006534-199406000-00022
    • Ahn CY, Shaw WW, Berns S, Markowitz BL,. Clinical experience with the 3M microvascular coupling anastomotic device in 100 free-tissue transfers. Plast Reconstr Surg 1994; 93: 1481-1484. (Pubitemid 24200750)
    • (1994) Plastic and Reconstructive Surgery , vol.93 , Issue.7 , pp. 1481-1484
    • Ahn, C.Y.1    Shaw, W.W.2    Berns, S.3    Markowitz, B.L.4
  • 9
    • 0028142199 scopus 로고
    • Clinical use of the 3M 2.5 mm mechanical microcoupling device in free tissue transfer
    • DOI 10.1002/micr.1920150610
    • Sasson HN, Stofman GM, Berman P,. Clinical use of the 3M 2.5 mm mechanical microcoupling device in free tissue transfer. Microsurgery 1994; 15: 421-423. (Pubitemid 24252222)
    • (1994) Microsurgery , vol.15 , Issue.6 , pp. 421-423
    • Sasson, H.N.1    Stofman, G.M.2    Berman, P.3
  • 10
    • 0028847103 scopus 로고
    • Microsurgical reconstruction of the lower extremity using the 3M microvascular coupling device in venous anastomoses
    • Denk MJ, Longaker MT, Basner AL, Glat PM, Karp NS, Kasabian AK,. Microsurgical reconstruction of the lower extremity using the 3M microvascular coupling device in venous anastomoses. Ann Plast Surg 1995; 35: 601-606.
    • (1995) Ann Plast Surg , vol.35 , pp. 601-606
    • Denk, M.J.1    Longaker, M.T.2    Basner, A.L.3    Glat, P.M.4    Karp, N.S.5    Kasabian, A.K.6
  • 11
    • 0031452234 scopus 로고    scopus 로고
    • Coupling the venous anastomosis: Safe and simple
    • de Bruijn HP, Marck KW,. Coupling the venous anastomosis: Safe and simple. Microsurgery 1996; 17: 414-416.
    • (1996) Microsurgery , vol.17 , pp. 414-416
    • De Bruijn, H.P.1    Marck, K.W.2
  • 12
    • 0032801538 scopus 로고    scopus 로고
    • Clinical experience in end-to-side venous anastomoses with a microvascular anastomotic coupling device in head and neck reconstruction
    • DeLacure MD, Kuriakose MA, Spies AL,. Clinical experience in end-to-side venous anastomoses with a microvascular anastomotic coupling device in head and neck reconstruction. Arch Otolaryngol Head Neck Surg 1999; 125: 869-872. (Pubitemid 29372806)
    • (1999) Archives of Otolaryngology - Head and Neck Surgery , vol.125 , Issue.8 , pp. 869-872
    • DeLacure, M.D.1    Kuriakose, M.A.2    Spies, A.L.3
  • 13
    • 0033759453 scopus 로고    scopus 로고
    • Venous anastomoses with a microvascular anastomotic device in head and neck reconstruction
    • Nishimoto S, Hikasa H, Ichino N, Kurita T, Yoshino K,. Venous anastomoses with a microvascular anastomotic device in head and neck reconstruction. J Reconstr Microsurg 2000; 16: 553-556.
    • (2000) J Reconstr Microsurg , vol.16 , pp. 553-556
    • Nishimoto, S.1    Hikasa, H.2    Ichino, N.3    Kurita, T.4    Yoshino, K.5
  • 14
    • 33751314744 scopus 로고    scopus 로고
    • Venous thrombosis in coupled versus sutured microvascular anastomoses
    • DOI 10.1097/01.sap.0000229958.57126.21, PII 0000063720061200000016
    • Yap LH, Constantinides J, Butler CE,. Venous thrombosis in coupled versus sutured microvascular anastomoses. Ann Plast Surg 2006; 57: 666-669. (Pubitemid 44808819)
    • (2006) Annals of Plastic Surgery , vol.57 , Issue.6 , pp. 666-669
    • Yap, L.H.1    Constantinides, J.2    Butler, C.E.3
  • 17
    • 0024414879 scopus 로고
    • Reconstruction of the lower extremity with microvascular free flaps: A 10-year experience with 304 consecutive cases
    • Khouri RK, Shaw WW,. Reconstruction of the lower extremity with microvascular free flaps: A 10-year experience with 304 consecutive cases. J Trauma 1989; 29: 1086-1094. (Pubitemid 19217450)
    • (1989) Journal of Trauma , vol.29 , Issue.8 , pp. 1086-1094
    • Khouri, R.1    Shaw, W.W.2
  • 18
    • 34548380405 scopus 로고    scopus 로고
    • Free tissue transfer to the lower extremity distal to the zone of injury: Indications and outcomes over a 25-year experience
    • DOI 10.1097/01.prs.0000255175.92201.c7, PII 0000653420070915000019
    • Spector JA, Levine S, Levine JP,. Free tissue transfer to the lower extremity distal to the zone of injury: Indications and outcomes over a 25-year experience. Plast Reconstr Surg 2007; 120: 952-959. (Pubitemid 47367893)
    • (2007) Plastic and Reconstructive Surgery , vol.120 , Issue.4 , pp. 952-959
    • Spector, J.A.1    Levine, S.2    Levine, J.P.3
  • 20
    • 0022468561 scopus 로고
    • Early microsurgical reconstruction of complex trauma of the extremities
    • Godina M,. Early microsurgical reconstruction of complex trauma of the extremities. Plast Reconstr Surg 1986; 78: 285-292. (Pubitemid 16049555)
    • (1986) Plastic and Reconstructive Surgery , vol.78 , Issue.3 , pp. 285-292
    • Godina, M.1
  • 21
    • 0025025084 scopus 로고
    • Flap failure after microvascular free-tissue transfer: The fate of a second attempt
    • Fearon JA, Cuadros CL, May JW Jr,. Flap failure after microvascular free-tissue transfer: The fate of a second attempt. Plast Reconstr Surg 1990; 86: 746-751. (Pubitemid 20319780)
    • (1990) Plastic and Reconstructive Surgery , vol.86 , Issue.4 , pp. 746-751
    • Fearon, J.A.1    Cuadros, C.L.2    May Jr., J.W.3
  • 22
    • 0026562737 scopus 로고
    • Microvascular soft-tissue transplantation for reconstruction of acute open tibial fractures: Timing of coverage and long-term functional results
    • Francel TJ, Vander Kolk CA, Hoopes JE, Manson PN, Yaremchuk MJ,. Microvascular soft-tissue transplantation for reconstruction of acute open tibial fractures: Timing of coverage and long-term functional results. Plast Reconstr Surg 1992; 89: 478-487.
    • (1992) Plast Reconstr Surg , vol.89 , pp. 478-487
    • Francel, T.J.1    Vander Kolk, C.A.2    Hoopes, J.E.3    Manson, P.N.4    Yaremchuk, M.J.5
  • 23
    • 0026730033 scopus 로고
    • Avoiding free flap failure
    • Khouri RK,. Avoiding free flap failure. Clin Plast Surg 1992; 19: 773-781.
    • (1992) Clin Plast Surg , vol.19 , pp. 773-781
    • Khouri, R.K.1
  • 25
    • 0025268005 scopus 로고
    • Microvascular anastomoses in irradiated vessels: A comparison between the Unilink system and sutures
    • Ragnarsson R, Berggren A, Klintenberg C, Ostrup L,. Microvascular anastomoses in irradiated vessels: A comparison between the Unilink system and sutures. Plast Reconstr Surg 1990; 85: 412-418. (Pubitemid 20099573)
    • (1990) Plastic and Reconstructive Surgery , vol.85 , Issue.3 , pp. 412-418
    • Ragnarsson, R.1    Berggren, A.2    Klintenberg, C.3    Ostrup, L.4
  • 26
    • 0041971040 scopus 로고    scopus 로고
    • Management of significant venous discrepancy with microvascular venous coupler
    • DOI 10.1055/s-2003-42632
    • Sullivan SK, Dellacroce F, Allen R,. Management of significant venous discrepancy with microvascular venous coupler. J Reconstr Microsurg 2003; 19: 377-380. (Pubitemid 37013031)
    • (2003) Journal of Reconstructive Microsurgery , vol.19 , Issue.6 , pp. 377-380
    • Sullivan, S.K.1    Dellacroce, F.2    Allen, R.3
  • 29
    • 33645381055 scopus 로고    scopus 로고
    • Routine use of microvascular coupling device for arterial anastomosis in breast reconstruction
    • Spector JA, Draper LB, Levine JP, Ahn CY,. Routine use of microvascular coupling device for arterial anastomosis in breast reconstruction. Ann Plast Surg 2006; 56: 365-368.
    • (2006) Ann Plast Surg , vol.56 , pp. 365-368
    • Spector, J.A.1    Draper, L.B.2    Levine, J.P.3    Ahn, C.Y.4
  • 30
    • 53049109559 scopus 로고    scopus 로고
    • Free DIEP and SIEA breast reconstruction to internal mammary intercostal perforating vessels with arterial microanastomosis using a mechanical coupling device
    • Rad AN, Flores JI, Rosson GD,. Free DIEP and SIEA breast reconstruction to internal mammary intercostal perforating vessels with arterial microanastomosis using a mechanical coupling device. Microsurgery 2008; 28: 407-411.
    • (2008) Microsurgery , vol.28 , pp. 407-411
    • Rad, A.N.1    Flores, J.I.2    Rosson, G.D.3
  • 31
    • 0024520579 scopus 로고
    • A microvascular anastomotic device: Part II. A histologic study in arteries and veins
    • DOI 10.1002/micr.1920100107
    • Blair WF, Morecraft RJ, Steyers CM, Maynard JA,. A microvascular anastomotic device: Part II. A histologic study in arteries and veins. Microsurgery 1989; 10: 29-39. (Pubitemid 19104633)
    • (1989) Microsurgery , vol.10 , Issue.1 , pp. 29-39
    • Blair, W.F.1    Morecraft, R.J.2    Steyers, C.M.3    Maynard, J.A.4
  • 32
    • 0024520578 scopus 로고
    • A microvascular anastomotic device: Part I. A hemodynamic evaluation in rabbit femoral arteries and veins
    • DOI 10.1002/micr.1920100106
    • Blair WF, Steyers CM, Brown TD, Gable RH,. A microvascular anastomotic device: Part I. A hemodynamic evaluation in rabbit femoral arteries and veins. Microsurgery 1989; 10: 21-28. (Pubitemid 19104632)
    • (1989) Microsurgery , vol.10 , Issue.1 , pp. 21-28
    • Blair, W.F.1    Steyers, C.M.2    Brown, T.D.3    Gable, R.H.4
  • 33
    • 0024561653 scopus 로고
    • Strength of microvascular anastomoses: Comparison between the Unilink anastomotic system and sutures
    • DOI 10.1002/micr.1920100108
    • Gilbert RW, Ragnarsson R, Berggren A, Ostrup L,. Strength of microvascular anastomoses: Comparison between the unilink anastomotic system and sutures. Microsurgery 1989; 10: 40-46. (Pubitemid 19104634)
    • (1989) Microsurgery , vol.10 , Issue.1 , pp. 40-46
    • Gilbert, R.W.1    Ragnarsson, R.2    Berggren, A.3    Ostrup, L.4
  • 35
    • 70449399244 scopus 로고    scopus 로고
    • Outcomes of microvascular reconstruction of single-vessel lower extremities: Limb salvage versus amputation
    • Ducic I, Rao SS, Attinger CE,. Outcomes of microvascular reconstruction of single-vessel lower extremities: Limb salvage versus amputation. J Reconstr Microsurg 2009; 25: 475-478.
    • (2009) J Reconstr Microsurg , vol.25 , pp. 475-478
    • Ducic, I.1    Rao, S.S.2    Attinger, C.E.3
  • 36
    • 0033869085 scopus 로고    scopus 로고
    • Trends in lower limb amputation in the Veterans Health Administration
    • Mayfield JA, Reiber GE, Maynard C,. Trends in lower limb amputation in the Veterans Health Administration. J Rehab Res Dev 2000; 37: 1989-1998.
    • (2000) J Rehab Res Dev , vol.37 , pp. 1989-1998
    • Mayfield, J.A.1    Reiber, G.E.2    Maynard, C.3
  • 37
    • 11144356746 scopus 로고    scopus 로고
    • Major lower leg amputation outcome of a modern series
    • Aulivola B,. Major lower leg amputation outcome of a modern series. Arch Surg 2004; 139: 395-401.
    • (2004) Arch Surg , vol.139 , pp. 395-401
    • Aulivola, B.1