메뉴 건너뛰기




Volumn 38, Issue 8, 2011, Pages 601-607

Five-year clinical evaluation of In-Ceram crowns fabricated using GN-I (CAD/CAM) system

Author keywords

Computer assisted design and computer assisted manufacturing; GN I system; In Ceram crown; Survival rate

Indexed keywords

ALUMINUM OXIDE; IN CERAM; IN-CERAM;

EID: 79960117511     PISSN: 0305182X     EISSN: 13652842     Source Type: Journal    
DOI: 10.1111/j.1365-2842.2010.02188.x     Document Type: Article
Times cited : (19)

References (32)
  • 1
    • 0024986205 scopus 로고
    • Vita In-Ceram, a new procedure for preparation of oxide-ceramic crown and bridge framework
    • Claus H. Vita In-Ceram, a new procedure for preparation of oxide-ceramic crown and bridge framework. Quintessenz Zhantech. 1990;16:35-46.
    • (1990) Quintessenz Zhantech , vol.16 , pp. 35-46
    • Claus, H.1
  • 2
    • 0027604308 scopus 로고
    • Survival rate of In-Ceram restorations
    • Pröbster L. Survival rate of In-Ceram restorations. Int J Prosthodont. 1993;6:259-263.
    • (1993) Int J Prosthodont , vol.6 , pp. 259-263
    • Pröbster, L.1
  • 3
    • 0029201763 scopus 로고
    • A report of anterior In-Ceram restorations
    • Pang SE. A report of anterior In-Ceram restorations. Ann Acad Med Singapore. 1995;24:33-37.
    • (1995) Ann Acad Med Singapore , vol.24 , pp. 33-37
    • Pang, S.E.1
  • 5
    • 0030095844 scopus 로고    scopus 로고
    • Four year clinical study of glass-infiltrated, sintered alumina crowns
    • Pröbster L. Four year clinical study of glass-infiltrated, sintered alumina crowns. J Oral Rehabil. 1996;23:147-151.
    • (1996) J Oral Rehabil , vol.23 , pp. 147-151
    • Pröbster, L.1
  • 6
    • 0034132550 scopus 로고    scopus 로고
    • Survival of In-Ceram crowns in a private practice: a prospective clinical trial
    • McLaren EA, White SN. Survival of In-Ceram crowns in a private practice: a prospective clinical trial. J Prosthet Dent. 2000;83:216-222.
    • (2000) J Prosthet Dent , vol.83 , pp. 216-222
    • McLaren, E.A.1    White, S.N.2
  • 8
    • 0035320246 scopus 로고    scopus 로고
    • Incidence of fractures and lifetime predictions of all-ceramic crown systems using censored data
    • Scherrer SS, De Rijk WG, Wiskott HW, Belser UC. Incidence of fractures and lifetime predictions of all-ceramic crown systems using censored data. Am J Dent. 2001;14:72-80.
    • (2001) Am J Dent , vol.14 , pp. 72-80
    • Scherrer, S.S.1    De Rijk, W.G.2    Wiskott, H.W.3    Belser, U.C.4
  • 9
    • 0035375073 scopus 로고    scopus 로고
    • Retrospective assessment of 546 all-ceramic anterior and posterior crowns in a general practice
    • Segal BS. Retrospective assessment of 546 all-ceramic anterior and posterior crowns in a general practice. J Prosthet Dent. 2001;85:544-550.
    • (2001) J Prosthet Dent , vol.85 , pp. 544-550
    • Segal, B.S.1
  • 10
    • 0036720154 scopus 로고    scopus 로고
    • An up to 5-year clinical evaluation of posterior In-Ceram CAD/CAM core crowns
    • Bindl A, Mörmann WH. An up to 5-year clinical evaluation of posterior In-Ceram CAD/CAM core crowns. Int J Prosthodont. 2002;15:451-456.
    • (2002) Int J Prosthodont , vol.15 , pp. 451-456
    • Bindl, A.1    Mörmann, W.H.2
  • 12
    • 79960150347 scopus 로고    scopus 로고
    • Das Kopierschleifen keramischer Formkorper (Med Diss thesis). Zürich 32-49, 1992. Bindl A, Mörmann WH. Klinische und technische Aspekte der CEREC In-Ceram Krone. Die Quintessenz.
    • Eidenbenz S. Das Kopierschleifen keramischer Formkorper (Med Diss thesis). Zürich 32-49, 1992. Bindl A, Mörmann WH. Klinische und technische Aspekte der CEREC In-Ceram Krone. Die Quintessenz. 1996;47:775-972.
    • (1996) , vol.47 , pp. 775-972
    • Eidenbenz, S.1
  • 13
    • 0347296462 scopus 로고    scopus 로고
    • Chairside-Computer-Kronen Verfahrenzeit und klinische Qualität
    • Bindl A, Mörmann WH. Chairside-Computer-Kronen Verfahrenzeit und klinische Qualität. Acta Med Dent Helv. 1997;2:293-300.
    • (1997) Acta Med Dent Helv , vol.2 , pp. 293-300
    • Bindl, A.1    Mörmann, W.H.2
  • 14
    • 0029339631 scopus 로고
    • Marginal accuracy and fracture strength of conventional and copy-milled all-ceramic crowns
    • Rinke S, Hüls A, Jahn L. Marginal accuracy and fracture strength of conventional and copy-milled all-ceramic crowns. Int J Prosthodont. 1995;8:303-310.
    • (1995) Int J Prosthodont , vol.8 , pp. 303-310
    • Rinke, S.1    Hüls, A.2    Jahn, L.3
  • 15
    • 2342652157 scopus 로고    scopus 로고
    • Survival rate of mono-ceramic and ceramic-core CAD/CAM-generated anterior crowns over 2-5years
    • Bindl A, Mörmann WH. Survival rate of mono-ceramic and ceramic-core CAD/CAM-generated anterior crowns over 2-5years. Eur J Oral Sci. 2004;112:197-204.
    • (2004) Eur J Oral Sci , vol.112 , pp. 197-204
    • Bindl, A.1    Mörmann, W.H.2
  • 16
    • 77950494521 scopus 로고    scopus 로고
    • Survival rates of porcelain molar crowns - An update
    • Kassem AS, Atta O, El-Mouafy O. Survival rates of porcelain molar crowns - An update. Int J Prosthodont. 2010;23:60-62.
    • (2010) Int J Prosthodont , vol.23 , pp. 60-62
    • Kassem, A.S.1    Atta, O.2    El-Mouafy, O.3
  • 19
    • 75949163484 scopus 로고
    • Periodontal disease in pregnancy. II. Correlation between oral hygiene and periodontal condition
    • Silness J, Löe H. Periodontal disease in pregnancy. II. Correlation between oral hygiene and periodontal condition. Acta Odontol Scand. 1964;22:121-135.
    • (1964) Acta Odontol Scand , vol.22 , pp. 121-135
    • Silness, J.1    Löe, H.2
  • 21
    • 33845382806 scopus 로고
    • Nonparametric estimation from incomplete observations
    • Kaplan EL, Meier P. Nonparametric estimation from incomplete observations. J Am Stat Assoc. 1958;53:457-465.
    • (1958) J Am Stat Assoc , vol.53 , pp. 457-465
    • Kaplan, E.L.1    Meier, P.2
  • 22
    • 0035502392 scopus 로고    scopus 로고
    • Procera AllCeram crowns followed for 5 to 10.5years: a prospective clinical study
    • Ödman P, Andersson B. Procera AllCeram crowns followed for 5 to 10.5years: a prospective clinical study. Int J Prosthodont. 2001;14:504-509.
    • (2001) Int J Prosthodont , vol.14 , pp. 504-509
    • Ödman, P.1    Andersson, B.2
  • 24
    • 70350157101 scopus 로고    scopus 로고
    • Clinical evaluation of Procera AllCeram crowns in Japanese patients: results after 5years
    • Kokubo Y, Sakurai S, Tsumita M, Ogawa T, Fukushima S. Clinical evaluation of Procera AllCeram crowns in Japanese patients: results after 5years. J Oral Rehabil. 2009;36:786-791.
    • (2009) J Oral Rehabil , vol.36 , pp. 786-791
    • Kokubo, Y.1    Sakurai, S.2    Tsumita, M.3    Ogawa, T.4    Fukushima, S.5
  • 26
    • 0020183392 scopus 로고
    • A comparative study of the strength of aluminous porcelain jacket crowns constructed with the conventional and twin foil technique
    • Munoz CA, Goodacre CJ, Moore BK, Dykema RW. A comparative study of the strength of aluminous porcelain jacket crowns constructed with the conventional and twin foil technique. J Prosthet Dent. 1982;48:271-281.
    • (1982) J Prosthet Dent , vol.48 , pp. 271-281
    • Munoz, C.A.1    Goodacre, C.J.2    Moore, B.K.3    Dykema, R.W.4
  • 27
    • 0035403111 scopus 로고    scopus 로고
    • Fracture strength of copy-milled and conventional In-Ceram crowns
    • Hwang JW, Yang JH. Fracture strength of copy-milled and conventional In-Ceram crowns. J Oral Rehabil. 2001;28:678-683.
    • (2001) J Oral Rehabil , vol.28 , pp. 678-683
    • Hwang, J.W.1    Yang, J.H.2
  • 28
    • 33746917163 scopus 로고    scopus 로고
    • Clinical long-term results of VITA In-Ceram classic crowns and fixed partial dentures: a systematic literature review
    • Wassermann A, Kaiser M, Atrub JR. Clinical long-term results of VITA In-Ceram classic crowns and fixed partial dentures: a systematic literature review. Int J Prosthodont. 2006;19:355-363.
    • (2006) Int J Prosthodont , vol.19 , pp. 355-363
    • Wassermann, A.1    Kaiser, M.2    Atrub, J.R.3
  • 29
    • 0034264517 scopus 로고    scopus 로고
    • Structural reliability of alumina-, feldspar-, leucite-, mica-, and zirconia-based ceramics
    • Tinschert J, Zwez D, Marx R, Anusavice KJ. Structural reliability of alumina-, feldspar-, leucite-, mica-, and zirconia-based ceramics. J Dent. 2000;28:529-535.
    • (2000) J Dent , vol.28 , pp. 529-535
    • Tinschert, J.1    Zwez, D.2    Marx, R.3    Anusavice, K.J.4
  • 31
    • 77649205143 scopus 로고    scopus 로고
    • A systematic review of the clinical performance of CAD/CAM single-tooth restorations
    • Wittneben J-G, Wright RF, Weber H-P, Gallucci GO. A systematic review of the clinical performance of CAD/CAM single-tooth restorations. Int J Prosthodont. 2009;22:466-471.
    • (2009) Int J Prosthodont , vol.22 , pp. 466-471
    • Wittneben, J.-G.1    Wright, R.F.2    Weber, H.-P.3    Gallucci, G.O.4
  • 32
    • 0022868060 scopus 로고    scopus 로고
    • Plaque retention on teeth restored with full-ceramic crowns: a comparative study
    • Chan C, Weber H. Plaque retention on teeth restored with full-ceramic crowns: a comparative study. J Prosthet Dent. 1996;56:666-671.
    • (1996) J Prosthet Dent , vol.56 , pp. 666-671
    • Chan, C.1    Weber, H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.