메뉴 건너뛰기




Volumn 37, Issue 4, 2011, Pages 332-340

Moulds in floor dust - a particular problem in mechanically ventilated rooms? A study of adolescent schoolboys under the Danish moulds in buildings program

Author keywords

Building related symptom; Combined effect; DAMIB; Dust; Fungi; Mechanical ventilation; Mold; Pupil; School

Indexed keywords

ADOLESCENCE; AIRFLOW; BUILDING; CHILD HEALTH; DISEASE PREVALENCE; DUST; FLOOR; HYPOTHESIS TESTING; LOGISTICS; QUESTIONNAIRE SURVEY; REGRESSION ANALYSIS; RESEARCH WORK; RISK FACTOR; VENTILATION;

EID: 79960067137     PISSN: 03553140     EISSN: 1795990X     Source Type: Journal    
DOI: 10.5271/sjweh.3135     Document Type: Article
Times cited : (9)

References (23)
  • 1
    • 20444507262 scopus 로고    scopus 로고
    • Molds in floor dust and building-related symptoms among adolescent school children: A problem for boys only?
    • Meyer HW, Würtz H, Suadicani P, Valbjrn O, Sigsgaard T, Gyntelberg F. Molds in floor dust and building-related symptoms among adolescent school children: a problem for boys only? Indoor Air. 2005;15 Suppl 10:17-24.
    • (2005) Indoor Air , vol.15 , Issue.10 , pp. 17-24
    • Meyer, H.W.1    Würtz, H.2    Suadicani, P.3    Valbjrn, O.4    Sigsgaard, T.5    Gyntelberg, F.6
  • 2
    • 0028923326 scopus 로고
    • Adverse effects of the indoor environment on respiratory health in primary school children
    • Cuijpers CE, Swaen GM, Wesseling G, Sturmans F, Wouters EF. Adverse effects of the indoor environment on respiratory health in primary school children. Environ. Res. 1995;68:11-23.
    • (1995) Environ. Res , vol.68 , pp. 11-23
    • Cuijpers, C.E.1    Swaen, G.M.2    Wesseling, G.3    Sturmans, F.4    Wouters, E.F.5
  • 5
    • 0031924888 scopus 로고    scopus 로고
    • Indoor airborne fungal spores, house dampness and associations with environmental factors and respiratory health in children
    • Garrett MH, Rayment PR, Hooper MA, Abramson MJ, Hooper BM. Indoor airborne fungal spores, house dampness and associations with environmental factors and respiratory health in children. Clin. Exp. Allergy. 1998;28:459-467.
    • (1998) Clin. Exp. Allergy , vol.28 , pp. 459-467
    • Garrett, M.H.1    Rayment, P.R.2    Hooper, M.A.3    Abramson, M.J.4    Hooper, B.M.5
  • 6
    • 0024374674 scopus 로고
    • Damp housing, mould growth, and symptomatic health state
    • Platt SD, Martin CJ, Hunt SM, Lewis CW. Damp housing, mould growth, and symptomatic health state. BMJ. 1989;298: 1673-1678.
    • (1989) BMJ , vol.298 , pp. 1673-1678
    • Platt, S.D.1    Martin, C.J.2    Hunt, S.M.3    Lewis, C.W.4
  • 7
    • 0035380085 scopus 로고    scopus 로고
    • Nordic Interdisciplinary Review of the Scientific Evidence on Associations between Exposure to "Dampness" in Buildings and Health Effects (NORDAMP)
    • Dampness in Buildings and Health
    • Bornehag CG, Blomquist G, Gyntelberg F, Järvholm B, Malmberg P, Nordvall L, Nielsen A, Pershagen G, and Sundell J. Dampness in Buildings and Health. Nordic Interdisciplinary Review of the Scientific Evidence on Associations between Exposure to "Dampness" in Buildings and Health Effects (NORDAMP). Indoor Air. 2001;11:72-86.
    • (2001) Indoor Air , vol.11 , pp. 72-86
    • Bornehag, C.G.1    Blomquist, G.2    Gyntelberg, F.3    Järvholm, B.4    Malmberg, P.5    Nordvall, L.6    Nielsen, A.7    Pershagen, G.8    Sundell, J.9
  • 8
    • 0038064215 scopus 로고    scopus 로고
    • Do indoor molds in nonindustrial environments threaten workers' Health? A Review of the Epidemiologic Evidence
    • Kolstad HA, Brauer C, Iversen M, Sigsgaard T, Mikkelsen S. Do Indoor Molds in Nonindustrial Environments Threaten Workers' Health? A Review of the Epidemiologic Evidence. Epidemiol Rev. 2002;24:203-217.
    • (2002) Epidemiol Rev , vol.24 , pp. 203-217
    • Kolstad, H.A.1    Brauer, C.2    Iversen, M.3    Sigsgaard, T.4    Mikkelsen, S.5
  • 9
    • 3242774472 scopus 로고    scopus 로고
    • EUROEXPO Dampness in building as a risk factor for health effects, EUROEXPO: A multidisciplinary review of the literature (1998-2000) on dampness ant mite exposure in buildings and health effects
    • Bornehag CG, Sundell J, Bonini S, Custovic A, Malmberg P, Skerfving S., Sigsgaard T., Verhoeff A.; EUROEXPO Dampness in building as a risk factor for health effects, EUROEXPO: a multidisciplinary review of the literature (1998-2000) on dampness ant mite exposure in buildings and health effects. Indoor Air. 2004;14(4): 243-57.
    • (2004) Indoor Air , vol.14 , Issue.4 , pp. 243-257
    • Bornehag, C.G.1    Sundell, J.2    Bonini, S.3    Custovic, A.4    Malmberg, P.5    Skerfving, S.6    Sigsgaard, T.7    Verhoeff, A.8
  • 10
    • 73449098860 scopus 로고    scopus 로고
    • WHO guidelines for indoor air quality: Dampness and mould
    • WHO Europe, Copenhagen: WHO, [Cited 23 November 2010, available from
    • WHO Europe. WHO guidelines for indoor air quality: dampness and mould. Copenhagen: WHO; 2009. [Cited 23 November 2010, available from: http://www.euro.who.int/__data/assets/pdf_file/0017/43325/E92645.pdf.]
    • (2009)
  • 13
    • 0006905554 scopus 로고    scopus 로고
    • Respiratory health effects of indoor microbial exposure. A contribution to the development of exposure assessment methods
    • Thesis, Wageningen
    • Douwes J. Respiratory health effects of indoor microbial exposure. A contribution to the development of exposure assessment methods. Thesis 1998; Wageningen: 1-171.
    • (1998) , pp. 1-171
    • Douwes, J.1
  • 14
    • 20844434666 scopus 로고    scopus 로고
    • Summary of human responses to ventilation
    • Seppänen OA, Fisk WJ. Summary of human responses to ventilation. Indoor Air 2004; 14 Suppl 7:102-118.
    • (2004) Indoor Air , vol.14 , Issue.7 , pp. 102-118
    • Seppänen, O.A.1    Fisk, W.J.2
  • 15
    • 84888451850 scopus 로고    scopus 로고
    • Are high levels of moulds in dust a greater problem in mechanically ventilated rooms
    • the Danish Moulds in Buildings-group, Copenhagen: paper-ID
    • Meyer HW, Würtz H, Suadicani P, Sigsgaard T, Nielsen PA, Gyntelberg F, the Danish Moulds in Buildings-group. Are high levels of moulds in dust a greater problem in mechanically ventilated rooms? In: Proceedings of Indoor Air 2008; Copenhagen: paper-ID 921.
    • (2008) Proceedings of Indoor Air , pp. 921
    • Meyer, H.W.1    Würtz, H.2    Suadicani, P.3    Sigsgaard, T.4    Nielsen, P.A.5    Gyntelberg, F.6
  • 17
    • 20444430882 scopus 로고    scopus 로고
    • The dustfall collector - a simple tool for long-term collection of airborne dust: A project under the Danish Mould in Buildings program
    • Würtz H, Sigsgaard T, Valbjørn O, Doekes G, Meyer HW. The dustfall collector - a simple tool for long-term collection of airborne dust: a project under the Danish Mould in Buildings program. Indoor Air. 2005;15 Suppl 9:33-40.
    • (2005) Indoor Air , vol.15 , Issue.SUPPL. 9 , pp. 33-40
    • Würtz, H.1    Sigsgaard, T.2    Valbjørn, O.3    Doekes, G.4    Meyer, H.W.5
  • 19
    • 0003560587 scopus 로고    scopus 로고
    • Multilevel analysis: An introduction to basic and advanced multilevel modeling
    • Thousand Oaks: SAGE Publications Ltd
    • Snijders TAB, Bosker RO. Multilevel analysis: an introduction to basic and advanced multilevel modeling. Thousand Oaks: SAGE Publications Ltd; 1999.
    • (1999)
    • Snijders, T.A.B.1    Bosker, R.O.2
  • 20
    • 31844443695 scopus 로고
    • The environment and disease: Association or causation
    • Hill AB. The environment and disease: association or causation? Proc. R. Soc. Med. 1965; 58:295-300.
    • (1965) Proc. R. Soc. Med , vol.58 , pp. 295-300
    • Hill, A.B.1
  • 22
    • 1542741005 scopus 로고    scopus 로고
    • Microbial contamination of indoor air due to leakages from crawl space: A field study
    • Airaksinen M, Pasanen P, Kurnitski J, Seppänen O. Microbial contamination of indoor air due to leakages from crawl space: a field study. Indoor Air 2004b. 14:55-64.
    • (2004) Indoor Air , vol.14 , pp. 55-64
    • Airaksinen, M.1    Pasanen, P.2    Kurnitski, J.3    Seppänen, O.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.