메뉴 건너뛰기




Volumn 94, Issue 7, 2011, Pages 794-800

Posterior C1-C2 fusion using C1 lateral mass and C2 pars screw with rod fixation: Techniques and outcomes

Author keywords

Atlanto axial fixation; C1 lateral mass screw; C2 pars screw; Craniocervical junction; Polyaxial screws and rods; Posterior fixation

Indexed keywords

ADOLESCENT; ADULT; ARTICLE; ATLANTOAXIAL SUBLUXATION; CERVICAL SPINE; CLINICAL ARTICLE; CLINICAL FEATURE; DISEASE DURATION; FEMALE; FIXATION DEVICE; HUMAN; INTRAMEDULLARY NAILING; MALE; OUTCOME ASSESSMENT; PARS SCREW; SPINE FUSION; SPINE STABILIZATION; SURGICAL TECHNIQUE; TRAFFIC ACCIDENT;

EID: 79960061470     PISSN: 01252208     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (11)

References (13)
  • 1
    • 0033945854 scopus 로고    scopus 로고
    • Anatomical evaluation of the groove for the vertebral artery in the axis vertebrae for atlantoaxial transarticular screw fixation technique
    • Kazan S, Yildirim F, Sindel M, Tuncer R. Anatomical evaluation of the groove for the vertebral artery in the axis vertebrae for atlantoaxial transarticular screw fixation technique. Clin Anat 2000; 13: 237-243.
    • (2000) Clin Anat , vol.13 , pp. 237-243
    • Kazan, S.1    Yildirim, F.2    Sindel, M.3    Tuncer, R.4
  • 2
    • 0030973318 scopus 로고    scopus 로고
    • Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique
    • Madawi AA, Casey AT, Solanki GA, Tuite G, Veres R, Crockard HA. Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique. J Neurosurg 1997; 86: 961-968.
    • (1997) J Neurosurg , vol.86 , pp. 961-968
    • Madawi, A.A.1    Casey, A.T.2    Solanki, G.A.3    Tuite, G.4    Veres, R.5    Crockard, H.A.6
  • 3
    • 0029773340 scopus 로고    scopus 로고
    • The anatomical suitability of the C1-2 complex for transarticular screw fixation
    • Paramore CG, Dickman CA, Sonntag VK. The anatomical suitability of the C1-2 complex for transarticular screw fixation. J Neurosurg 1996; 85: 221-224.
    • (1996) J Neurosurg , vol.85 , pp. 221-224
    • Paramore, C.G.1    Dickman, C.A.2    Sonntag, V.K.3
  • 4
    • 0035890208 scopus 로고    scopus 로고
    • Posterior C1-C2 fusion with polyaxial screw and rod fixation
    • Harms J, Melcher RP. Posterior C1-C2 fusion with polyaxial screw and rod fixation. Spine (Phila Pa 1976) 2001; 26: 2467-2471.
    • (2001) Spine (Phila Pa 1976) , vol.26 , pp. 2467-2471
    • Harms, J.1    Melcher, R.P.2
  • 6
    • 13444291294 scopus 로고    scopus 로고
    • Biomechanical comparison of two stabilization techniques of the atlantoaxial joints: Transarticular screw fixation versus screw and rod fixation
    • Kuroki H, Rengachary SS, Goel VK, Holekamp SA, Pitkanen V, Ebraheim NA. Biomechanical comparison of two stabilization techniques of the atlantoaxial joints: transarticular screw fixation versus screw and rod fixation. Neurosurgery 2005; 56: 151-159.
    • (2005) Neurosurgery , vol.56 , pp. 151-159
    • Kuroki, H.1    Rengachary, S.S.2    Goel, V.K.3    Holekamp, S.A.4    Pitkanen, V.5    Ebraheim, N.A.6
  • 7
    • 0026499484 scopus 로고
    • Craniocervical junction malformation treated by transoral approach. A survey of 25 cases with emphasis on postoperative instability and outcome
    • di Lorenzo N. Craniocervical junction malformation treated by transoral approach. A survey of 25 cases with emphasis on postoperative instability and outcome. Acta Neurochir (Wien) 1992; 118: 112-116.
    • (1992) Acta Neurochir (Wien) , vol.118 , pp. 112-116
    • di Lorenzo, N.1
  • 9
    • 29444456659 scopus 로고    scopus 로고
    • The clinical risk of vertebral artery injury from cervical pedicle screws inserted in degenerative vertebrae
    • Neo M, Sakamoto T, Fujibayashi S, Nakamura T. The clinical risk of vertebral artery injury from cervical pedicle screws inserted in degenerative vertebrae. Spine (Phila Pa 1976) 2005; 30: 2800-5.
    • (2005) Spine (Phila Pa 1976) , Issue.30 , pp. 2800-2805
    • Neo, M.1    Sakamoto, T.2    Fujibayashi, S.3    Nakamura, T.4
  • 11
    • 0036954405 scopus 로고    scopus 로고
    • Atlantoaxial fixation using plate and screw method: A report of 160 treated patients
    • Goel A, Desai KI, Muzumdar DP. Atlantoaxial fixation using plate and screw method: a report of 160 treated patients. Neurosurgery 2002; 51: 1351-1356.
    • (2002) Neurosurgery , vol.51 , pp. 1351-1356
    • Goel, A.1    Desai, K.I.2    Muzumdar, D.P.3
  • 12
    • 0034128001 scopus 로고    scopus 로고
    • The optimal transarticular c1-2 screw length and the location of the hypoglossal nerve
    • Ebraheim NA, Misson JR, Xu R, Yeasting RA. The optimal transarticular c1-2 screw length and the location of the hypoglossal nerve. Surg Neurol 2000; 53: 208-210.
    • (2000) Surg Neurol , vol.53 , pp. 208-210
    • Ebraheim, N.A.1    Misson, J.R.2    Xu, R.3    Yeasting, R.A.4
  • 13
    • 2442579305 scopus 로고    scopus 로고
    • Anatomic relationship of the internal carotid artery to the C1 vertebra: A case report of cervical reconstruction for chordoma and pilot study to assess the risk of screw fixation of the atlas
    • Currier BL, Todd LT, Maus TP, Fisher DR, Yaszemski MJ. Anatomic relationship of the internal carotid artery to the C1 vertebra: A case report of cervical reconstruction for chordoma and pilot study to assess the risk of screw fixation of the atlas. Spine (Phila Pa 1976) 2003; 28: E461-E467.
    • (2003) Spine (Phila Pa 1976) , vol.28
    • Currier, B.L.1    Todd, L.T.2    Maus, T.P.3    Fisher, D.R.4    Yaszemski, M.J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.