-
1
-
-
0035679781
-
Congenital coronary artery anomalies: The pediatric perspective
-
DOI 10.1097/00019501-200112000-00003
-
GH Burch DJ Sahn 2001 Congenital coronary artery anomalies: the pediatric perspective Coron Artery Dis 12 605 616 11811325 10.1097/00019501-200112000- 00003 1:STN:280:DC%2BD38%2FosVSmsQ%3D%3D (Pubitemid 34033052)
-
(2001)
Coronary Artery Disease
, vol.12
, Issue.8
, pp. 605-616
-
-
Burch, G.H.1
Sahn, D.J.2
-
2
-
-
0036448964
-
Congenital heart defects and coronary anatomy
-
JB Mawson 2002 Congenital heart defects and coronary anatomy Tex Heart Inst J 29 279 289 12484612 (Pubitemid 35435211)
-
(2002)
Texas Heart Institute Journal
, vol.29
, Issue.4
, pp. 279-289
-
-
Mawson, J.B.1
-
3
-
-
59449107983
-
Coronary artery anomalies and clinically important anatomy in patients with congenital heart disease: Multislice CT findings
-
19159923 10.1007/s00247-008-1111-7
-
HW Goo DM Seo TJ Yun, et al. 2009 Coronary artery anomalies and clinically important anatomy in patients with congenital heart disease: multislice CT findings Pediatr Radiol 39 265 273 19159923 10.1007/s00247-008- 1111-7
-
(2009)
Pediatr Radiol
, vol.39
, pp. 265-273
-
-
Goo, H.W.1
Seo, D.M.2
Yun, T.J.3
-
4
-
-
21244498960
-
Computed tomography for the diagnosis of congenital heart disease in pediatric and adult patients
-
DOI 10.1007/s10554-004-4015-0
-
HW Goo IS Park JK Ko, et al. 2005 Computed tomography for the diagnosis of congenital heart disease in pediatric and adult patients Int J Cardiovasc Imaging 21 347 365 16015453 10.1007/s10554-004-4015-0 discussion 367 (Pubitemid 40895346)
-
(2005)
International Journal of Cardiovascular Imaging
, vol.21
, Issue.2-3
, pp. 347-365
-
-
Goo, H.W.1
Park, I.-S.2
Ko, J.K.3
Kim, Y.H.4
Seo, D.-M.5
Park, J.-J.6
-
5
-
-
33947259581
-
Demonstration of coronary arteries and major cardiac vascular structures in congenital heart disease by cardiac multidetector computed tomography angiography
-
17311774 10.1532/HSF98.20061013
-
OF Dogan M Karcaaltincaba C Yorgancioglu, et al. 2007 Demonstration of coronary arteries and major cardiac vascular structures in congenital heart disease by cardiac multidetector computed tomography angiography Heart Surg Forum 10 E90 E94 17311774 10.1532/HSF98.20061013
-
(2007)
Heart Surg Forum
, vol.10
-
-
Dogan, O.F.1
Karcaaltincaba, M.2
Yorgancioglu, C.3
-
6
-
-
34247855917
-
MDCT evaluation after closure of atrial septal defect with an Amplatzer septal occluder
-
17449739 10.2214/AJR.06.0709
-
T Lee IC Tsai YC Fu, et al. 2007 MDCT evaluation after closure of atrial septal defect with an Amplatzer septal occluder AJR Am J Roentgenol 188 W431 W439 17449739 10.2214/AJR.06.0709
-
(2007)
AJR Am J Roentgenol
, vol.188
-
-
Lee, T.1
Tsai, I.C.2
Fu, Y.C.3
-
7
-
-
34547202649
-
Three-dimensional CT scanning: A new diagnostic modality in congenital heart disease
-
DOI 10.1136/hrt.2006.101352
-
P Ou DS Celermajer G Calcagni, et al. 2007 Three-dimensional CT scanning: a new diagnostic modality in congenital heart disease Heart 93 908 913 16952967 10.1136/hrt.2006.101352 (Pubitemid 47122036)
-
(2007)
Heart
, vol.93
, Issue.8
, pp. 908-913
-
-
Ou, P.1
Celermajer, D.S.2
Calcagni, G.3
Brunelle, F.4
Bonnet, D.5
Sidi, D.6
-
8
-
-
34249875981
-
Gradual pulmonary artery enhancement: New sign of septal defects on CT
-
DOI 10.2214/AJR.06.0572
-
IC Tsai T Lee MC Chen, et al. 2007 Gradual pulmonary artery enhancement: new sign of septal defects on CT AJR Am J Roentgenol 188 1660 1664 17515391 10.2214/AJR.06.0572 (Pubitemid 46866873)
-
(2007)
American Journal of Roentgenology
, vol.188
, Issue.6
, pp. 1660-1664
-
-
Tsai, I.-C.1
Lee, T.2
Chen, M.-C.3
Fu, Y.-C.4
Jan, S.-L.5
Tsai, W.-L.6
Wang, C.-C.7
-
9
-
-
51349120249
-
Surgically corrected congenital heart disease: Utility of 64-MDCT
-
18716119 10.2214/AJR.07.2889
-
PJ Spevak PT Johnson EK Fishman 2008 Surgically corrected congenital heart disease: utility of 64-MDCT AJR Am J Roentgenol 191 854 861 18716119 10.2214/AJR.07.2889
-
(2008)
AJR Am J Roentgenol
, vol.191
, pp. 854-861
-
-
Spevak, P.J.1
Johnson, P.T.2
Fishman, E.K.3
-
10
-
-
40849133825
-
Neonatal cardiac multidetector row CT: Why and how we do it
-
18259739 10.1007/s00247-008-0761-9
-
IC Tsai MC Chen SL Jan, et al. 2008 Neonatal cardiac multidetector row CT: why and how we do it Pediatr Radiol 38 438 451 18259739 10.1007/s00247-008- 0761-9
-
(2008)
Pediatr Radiol
, vol.38
, pp. 438-451
-
-
Tsai, I.C.1
Chen, M.C.2
Jan, S.L.3
-
11
-
-
68449092006
-
Low-dose coronary artery computed tomography angiogram of an infant with tetralogy of fallot using a 256-slice multidetector computed tomography scanner
-
19214622 10.1007/s00246-009-9389-2
-
DM Bardo J Asamato CS Mackay, et al. 2009 Low-dose coronary artery computed tomography angiogram of an infant with tetralogy of fallot using a 256-slice multidetector computed tomography scanner Pediatr Cardiol 30 824 826 19214622 10.1007/s00246-009-9389-2
-
(2009)
Pediatr Cardiol
, vol.30
, pp. 824-826
-
-
Bardo, D.M.1
Asamato, J.2
MacKay, C.S.3
-
12
-
-
39349101981
-
Cardiac computed tomography: Indications, applications, limitations, and training requirements - Report of a Writing Group deployed by the Working Group Nuclear Cardiology and Cardiac CT of the European Society of Cardiology and the European Council of Nuclear Cardiology
-
DOI 10.1093/eurheartj/ehm544
-
S Schroeder S Achenbach F Bengel, et al. 2008 Cardiac computed tomography: indications, applications, limitations, and training requirements: report of a Writing Group deployed by the Working Group Nuclear Cardiology and Cardiac CT of the European Society of Cardiology and the European Council of Nuclear Cardiology Eur Heart J 29 531 556 18084017 10.1093/eurheartj/ehm544 (Pubitemid 351264173)
-
(2008)
European Heart Journal
, vol.29
, Issue.4
, pp. 531-556
-
-
Schroeder, S.1
Achenbach, S.2
Bengel, F.3
Burgstahler, C.4
Cademartiri, F.5
De Feyter, P.6
George, R.7
Kaufmann, P.8
Kopp, A.F.9
Knuuti, J.10
Ropers, D.11
Schuijf, J.12
Tops, L.F.13
Bax, J.J.14
-
13
-
-
33645750684
-
Tube current reduction in pediatric non-ECG-gated heart CT by combined tube current modulation
-
16501970 10.1007/s00247-005-0105-y
-
HW Goo DS Suh 2006 Tube current reduction in pediatric non-ECG-gated heart CT by combined tube current modulation Pediatr Radiol 36 344 351 16501970 10.1007/s00247-005-0105-y
-
(2006)
Pediatr Radiol
, vol.36
, pp. 344-351
-
-
Goo, H.W.1
Suh, D.S.2
-
14
-
-
34250806587
-
Pediatric cardiac-gated CT angiography: Assessment of radiation dose
-
DOI 10.2214/AJR.06.1507
-
CL Hollingsworth TT Yoshizumi DP Frush, et al. 2007 Pediatric cardiac-gated CT angiography: assessment of radiation dose AJR Am J Roentgenol 189 12 18 17579144 10.2214/AJR.06.1507 (Pubitemid 46983178)
-
(2007)
American Journal of Roentgenology
, vol.189
, Issue.1
, pp. 12-18
-
-
Hollingsworth, C.L.1
Yoshizumi, T.T.2
Frush, D.P.3
Chan, F.P.4
Toncheva, G.5
Nguyen, G.6
Lowry, C.R.7
Hurwitz, L.M.8
-
15
-
-
43649107007
-
Pediatric cardiovascular CT angiography: Radiation dose reduction using automatic anatomic tube current modulation
-
DOI 10.2214/AJR.07.3124
-
C Herzog DM Mulvihill SA Nguyen, et al. 2008 Pediatric cardiovascular CT angiography: radiation dose reduction using automatic anatomic tube current modulation AJR Am J Roentgenol 190 1232 1240 18430837 10.2214/AJR.07.3124 (Pubitemid 351684935)
-
(2008)
American Journal of Roentgenology
, vol.190
, Issue.5
, pp. 1232-1240
-
-
Herzog, C.1
Mulvihill, D.M.2
Nguyen, S.A.3
Savino, G.4
Schmidt, B.5
Costello, P.6
Vogl, T.J.7
Schoepf, U.J.8
-
16
-
-
68449090034
-
Adequate image quality with reduced radiation dose in prospectively triggered coronary CTA compared with retrospective techniques
-
19415293 10.1007/s00330-009-1411-9
-
E Arnoldi TR Johnson C Rist, et al. 2009 Adequate image quality with reduced radiation dose in prospectively triggered coronary CTA compared with retrospective techniques Eur Radiol 19 2147 2155 19415293 10.1007/s00330-009- 1411-9
-
(2009)
Eur Radiol
, vol.19
, pp. 2147-2155
-
-
Arnoldi, E.1
Johnson, T.R.2
Rist, C.3
-
17
-
-
69149083246
-
Evaluation of image quality and radiation dose of thoracic and coronary dual-source CT in 110 infants with congenital heart disease
-
19319514 10.1007/s00247-009-1209-6
-
M Ben Saad A Rohnean A Sigal-Cinqualbre, et al. 2009 Evaluation of image quality and radiation dose of thoracic and coronary dual-source CT in 110 infants with congenital heart disease Pediatr Radiol 39 668 676 19319514 10.1007/s00247-009-1209-6
-
(2009)
Pediatr Radiol
, vol.39
, pp. 668-676
-
-
Ben Saad, M.1
Rohnean, A.2
Sigal-Cinqualbre, A.3
-
18
-
-
64149120137
-
Radiation dose and image quality of prospective triggering with dual-source cardiac computed tomography
-
19361609 10.1016/j.amjcard.2008.12.045
-
R Blankstein A Shah R Pale, et al. 2009 Radiation dose and image quality of prospective triggering with dual-source cardiac computed tomography Am J Cardiol 103 1168 1173 19361609 10.1016/j.amjcard.2008.12.045
-
(2009)
Am J Cardiol
, vol.103
, pp. 1168-1173
-
-
Blankstein, R.1
Shah, A.2
Pale, R.3
-
19
-
-
63649084581
-
Strategies for dose-optimized imaging in pediatric cardiac dual source CT
-
19291603 1:STN:280:DC%2BD1M3htlegsA%3D%3D
-
A Kuettner B Gehann J Spolnik, et al. 2009 Strategies for dose-optimized imaging in pediatric cardiac dual source CT Rofo 181 339 348 19291603 1:STN:280:DC%2BD1M3htlegsA%3D%3D
-
(2009)
Rofo
, vol.181
, pp. 339-348
-
-
Kuettner, A.1
Gehann, B.2
Spolnik, J.3
-
20
-
-
63849123042
-
Image quality in a low radiation exposure protocol for retrospectively ECG-gated coronary CT angiography
-
19304712 10.2214/AJR.08.1025
-
T Pflederer L Rudofsky D Ropers, et al. 2009 Image quality in a low radiation exposure protocol for retrospectively ECG-gated coronary CT angiography AJR Am J Roentgenol 192 1045 1050 19304712 10.2214/AJR.08.1025
-
(2009)
AJR Am J Roentgenol
, vol.192
, pp. 1045-1050
-
-
Pflederer, T.1
Rudofsky, L.2
Ropers, D.3
-
21
-
-
70350210490
-
Prospectively ECG-triggered high-pitch spiral acquisition for coronary CT angiography using dual source CT: Technique and initial experience
-
19760421 10.1007/s00330-009-1558-4
-
M Lell M Marwan T Schepis, et al. 2009 Prospectively ECG-triggered high-pitch spiral acquisition for coronary CT angiography using dual source CT: technique and initial experience Eur Radiol 19 2576 2583 19760421 10.1007/s00330-009-1558-4
-
(2009)
Eur Radiol
, vol.19
, pp. 2576-2583
-
-
Lell, M.1
Marwan, M.2
Schepis, T.3
-
22
-
-
34547108344
-
Visualization of neonatal coronary arteries on multidetector row CT: ECG-gated versus non-ECG-gated technique
-
DOI 10.1007/s00247-007-0512-3
-
IC Tsai T Lee MC Chen, et al. 2007 Visualization of neonatal coronary arteries on multidetector row CT: ECG-gated versus non-ECG-gated technique Pediatr Radiol 37 818 825 17562037 10.1007/s00247-007-0512-3 (Pubitemid 47097427)
-
(2007)
Pediatric Radiology
, vol.37
, Issue.8
, pp. 818-825
-
-
Tsai, I.-C.1
Lee, T.2
Chen, M.-C.3
Fu, Y.-C.4
Jan, S.-L.5
Wang, C.-C.6
Chang, Y.7
-
23
-
-
23644435282
-
Visibility of the origin and proximal course of coronary arteries on non-ECG-gated heart CT in patients with congenital heart disease
-
DOI 10.1007/s00247-005-1482-y
-
HW Goo IS Park JK Ko, et al. 2005 Visibility of the origin and proximal course of coronary arteries on non-ECG-gated heart CT in patients with congenital heart disease Pediatr Radiol 35 792 798 15886981 10.1007/s00247-005- 1482-y (Pubitemid 41131180)
-
(2005)
Pediatric Radiology
, vol.35
, Issue.8
, pp. 792-798
-
-
Goo, H.W.1
Park, I.-S.2
Ko, J.K.3
Kim, Y.H.4
Seo, D.-M.5
Yun, T.-J.6
Park, J.-J.7
-
24
-
-
62649158904
-
Prospectively gated axial CT coronary angiography: Preliminary experiences with a novel low-dose technique
-
19011864 10.1007/s00330-008-1222-4
-
O Klass M Jeltsch S Feuerlein, et al. 2009 Prospectively gated axial CT coronary angiography: preliminary experiences with a novel low-dose technique Eur Radiol 19 829 836 19011864 10.1007/s00330-008-1222-4
-
(2009)
Eur Radiol
, vol.19
, pp. 829-836
-
-
Klass, O.1
Jeltsch, M.2
Feuerlein, S.3
-
25
-
-
77951104451
-
Retrospective versus prospective ECG-gated dual-source CT in pediatric patients with congenital heart diseases: Comparison of image quality and radiation dose
-
20044793 10.1007/s10554-009-9579-2
-
KN Jin EA Park CI Shin, et al. 2010 Retrospective versus prospective ECG-gated dual-source CT in pediatric patients with congenital heart diseases: comparison of image quality and radiation dose Int J Cardiovasc Imaging 26 Suppl 1 63 73 20044793 10.1007/s10554-009-9579-2
-
(2010)
Int J Cardiovasc Imaging
, vol.26
, Issue.SUPPL. 1
, pp. 63-73
-
-
Jin, K.N.1
Park, E.A.2
Shin, C.I.3
-
26
-
-
77957867019
-
Low-dose prospective ECG-triggering dual-source CT angiography in infants and children with complex congenital heart disease: First experience
-
20532783 10.1007/s00330-010-1822-7
-
Z Cheng X Wang Y Duan, et al. 2010 Low-dose prospective ECG-triggering dual-source CT angiography in infants and children with complex congenital heart disease: first experience Eur Radiol 20 2503 2511 20532783 10.1007/s00330-010- 1822-7
-
(2010)
Eur Radiol
, vol.20
, pp. 2503-2511
-
-
Cheng, Z.1
Wang, X.2
Duan, Y.3
-
27
-
-
79953812989
-
Radiation dose for thoracic and coronary step-and-shoot CT using a 128-slice dual-source machine in infants and small children with congenital heart disease
-
Paul JF, Rohnean A, Elfassy E et al (2010) Radiation dose for thoracic and coronary step-and-shoot CT using a 128-slice dual-source machine in infants and small children with congenital heart disease. Pediatr Radiol 41:244-249
-
(2010)
Pediatr Radiol
, vol.41
, pp. 244-249
-
-
Paul, J.F.1
Rohnean, A.2
Elfassy, E.3
-
28
-
-
77957580169
-
Coronary artery visibility in free-breathing young children with congenital heart disease on cardiac 64-slice CT: Dual-source ECG-triggered sequential scan vs. single-source non-ECG-synchronized spiral scan
-
20464385 10.1007/s00247-010-1693-8
-
HW Goo DH Yang 2010 Coronary artery visibility in free-breathing young children with congenital heart disease on cardiac 64-slice CT: dual-source ECG-triggered sequential scan vs. single-source non-ECG-synchronized spiral scan Pediatr Radiol 40 1670 1680 20464385 10.1007/s00247-010-1693-8
-
(2010)
Pediatr Radiol
, vol.40
, pp. 1670-1680
-
-
Goo, H.W.1
Yang, D.H.2
-
29
-
-
67949094410
-
New radiation dose saving technologies for 256-slice cardiac computed tomography angiography
-
10.1007/s10554-009-9444-3
-
MJ Walker ME Olzsewki MY Desai 2009 New radiation dose saving technologies for 256-slice cardiac computed tomography angiography Int J Cardiovasc Imaging 25 Suppl 2 189 199 10.1007/s10554-009-9444-3
-
(2009)
Int J Cardiovasc Imaging
, vol.25
, Issue.SUPPL. 2
, pp. 189-199
-
-
Walker, M.J.1
Olzsewki, M.E.2
Desai, M.Y.3
-
30
-
-
33947614137
-
Homogeneous enhancement in pediatric thoracic CT aortography using a novel and reproducible method: Contrast-covering time
-
DOI 10.2214/AJR.06.0902
-
IC Tsai T Lee MC Chen, et al. 2007 Homogeneous enhancement in pediatric thoracic CT aortography using a novel and reproducible method: contrast-covering time AJR Am J Roentgenol 188 1131 1137 17377058 10.2214/AJR.06.0902 (Pubitemid 46496954)
-
(2007)
American Journal of Roentgenology
, vol.188
, Issue.4
, pp. 1131-1137
-
-
Tsai, I.-C.1
Lee, T.2
Chen, M.-C.3
Tsai, W.-L.4
Lin, P.-C.5
Liao, W.-C.6
-
31
-
-
43149119002
-
Age-specific effective doses for pediatric MSCT examinations at a large children's hospital using DLP conversion coefficients: A simple estimation method
-
18392817 10.1007/s00247-008-0794-0
-
KE Thomas B Wang 2008 Age-specific effective doses for pediatric MSCT examinations at a large children's hospital using DLP conversion coefficients: a simple estimation method Pediatr Radiol 38 645 656 18392817 10.1007/s00247-008-0794-0
-
(2008)
Pediatr Radiol
, vol.38
, pp. 645-656
-
-
Thomas, K.E.1
Wang, B.2
-
32
-
-
76049129406
-
State-of-the-art CT imaging techniques for congenital heart disease
-
20046490 10.3348/kjr.2010.11.1.4
-
HW Goo 2010 State-of-the-art CT imaging techniques for congenital heart disease Korean J Radiol 11 4 18 20046490 10.3348/kjr.2010.11.1.4
-
(2010)
Korean J Radiol
, vol.11
, pp. 4-18
-
-
Goo, H.W.1
-
34
-
-
33750106461
-
Higher intracoronary attenuation improves diagnostic accuracy in MDCT coronary angiography
-
16985117 10.2214/AJR.05.1406
-
F Cademartiri NR Mollet PA Lemos, et al. 2006 Higher intracoronary attenuation improves diagnostic accuracy in MDCT coronary angiography AJR Am J Roentgenol 187 W430 W433 16985117 10.2214/AJR.05.1406
-
(2006)
AJR Am J Roentgenol
, vol.187
-
-
Cademartiri, F.1
Mollet, N.R.2
Lemos, P.A.3
|